• Title/Summary/Keyword: Artificial resin denture teeth

Search Result 35, Processing Time 0.026 seconds

Comparison Study of Wear Resistance Among Several Denture Teeth Opposing Various Restorative Materials (대합되는 재료에 따른 합성수지 인공치의 마모저항성에 관한 비교 연구)

  • Park, Young-Bae
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.63-74
    • /
    • 2009
  • Partial or complete prosthesis is needed when teeth are lost due to various kinds of reason. Artificial teeth recover occlusion instead of natural teeth. Artificial teeth are required of esthetics, fragile resistance and abrasive resistance. Artificial tooth is made of acrylic resin or porcelain. Nowadays, acrylic resin artificial teeth are mainly used. Acrylic resin teeth are occluded with natural teeth, gold alloy, Ni-Cr alloy or porcelain etc. Acrylic resin teeth have similar translucency, gloss of natural teeth. And it has good chemical bond with denture base material, but it has low wear resistance. The aim of this study is to compare wear resistance among several denture teeth(Endura, SR-orthosit-PE, Planustar) and between artificial resin denture teeth and opposing 3 restorative materials(gold, Ni-Cr alloy, porcelain). Wear tests were conducted with a rotating wear testing apparatus(pin-on-disk type wear tester) under conditions of rpm 180, 75 minutes and constant loading of 50N. The upper part was the cusp of maxillary first molar and the lower part was a disk type restorative materials. To make similar oral environment, water was supplied continually. The acrylic resin teeth wear was determined by weighing the cusp each 5 minutes during 75 minutes test. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows: 1. Wear rates of acrylic resin teeth opposing to the restorative materials were high in order of Porcelain, Gold, Ni-Cr alloy (p<.05). 2. Wear resistance rate opposing to the Porcelain disk, was shown in order of Endura, SR-orthosit-PE, Planustar. The wear rate of opposing to porcelain disk was above two times more than that of other groups (p<.05). 3. Wear resistance rates opposing to the Gold, Ni-Cr alloy disk, was shown in order of Endura, SR-orthosit-PE, Planustar (p<.05). 4. A degree of the surface hardness is directly proportional to the degree of wear resistance. There are statistically significant differences between each groups (p<.05).

  • PDF

Study on shear bond strength of various composite resins to artificial denture teeth (수복용 레진과 인공치아간의 결합강도 연구)

  • Park, Kyung-Mo
    • Journal of Technologic Dentistry
    • /
    • v.36 no.3
    • /
    • pp.171-177
    • /
    • 2014
  • Purpose: The dental medicine has been preparing the custom-made service to meet the requirements of the aged society, while the average span of human life is growing more and more, and the full denture is a representative of them. It is causing great concern in these atmosphere of society, and demands for it are expected to increase. The full denture is a uniform combination of denture base and artificial teeth using polymerization, and is most influenced by change of physical properties of denture base and bonding strength with artificial teeth. Methods: In this study, the samples were made of composite resin combined with occlusion surface of artificial teeth undergone mechanically surface treatment to evaluate the bonding strength of composite resin for repairing artificial teeth. The resin teeth used in this study are 3 types artificial teeth. And 3 types of composite resins are used that are various polymerization resin. The shear strength of composite resins made in various polymerization ways to resin teeth was measured to evaluate bonding strength of artificial teeth to each composite resins. Results: Surface hardness's results on Trubyte Biotone(74.58Hv), Biotone IPN(70.06Hv), Endura Posterio (64.48Hv). Results of bonding strength of artificial teeth to composite resins on ES samples(8.73Mpa), IF(4.37Mpa) and IZ(3.84Mpa). Conclusion: 1. The Trubyte Biotone(74.58Hv) was first, followed by Biotone IPN(70.06Hv), and Endura Posterio(64.48Hv) in surface hardness's results of worn sides using hardness test. 2. The ES samples(8.73Mpa) showed significant differences with IF(4.37Mpa) and IZ(3.84Mpa) (p<0.05), but not other samples(p>0.05) in results of bonding strength of artificial teeth to composite resins.

THE SHEAR BOND STRENGTH OF RESIN TEETH TO THE DENTURE BASE RESIN (레진치와 의치상 레진간의 전단 결합강도에 관한 연구)

  • Song, Young-Kuk;Jung, Young-Wan;Jin, Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.235-241
    • /
    • 1999
  • The bond failure of resin teeth In denture base resin is one of the failure in prosthodontic treatment. The purpose of this study was to evaluate the bond strength of artificial resin teeth to the denture base resins. Specimens were made with heat curing acrylic resins (Vertex Rs, Lucitone 199) and artificial resin teeth (Tiger, Trubyte biotone, Endura, Orthosit, Tubyte bioform IPN) and the bond strength were measured with testing machine(Zwick. Germany) and the mode of bond failure were observed. The results were as follows; 1. The bond strength of Vertex Rs to artificial resin teeth was the highest in Tubyte biotone, and It was the lowest in Tiger and Trubyte bioform IPN. 2. The bond strength of Lucitone 199 to artificial resin teeth were higher in Orthosit and Trubyte bioform IPN than in Tiger and Trubyte biotone. 3. The bond strength of Trubyte biotone to Vertex Rs was higher than to Lucitone 199 and that of the Trubyte bioform IPN to Lucitone 199 was higher than to Vertex Rs. 4. Nearly all bond failures of specimens occured cohesively within the resin teeth.

  • PDF

An Experimental Study on the Abrasion Tests as a Result of using Materials of Full Denture Occlusal Surface (총의치교합면의 사용재료에 따른 마모도 측정에 관한 실험적 연구)

  • Cha, Sung-Soo
    • Journal of Technologic Dentistry
    • /
    • v.5 no.1
    • /
    • pp.19-26
    • /
    • 1983
  • I got a conclusion as a result of that in case of constructing a full denture using acrylic resin teeth, porcelain teeth, and forming posterior occlusal surface of the artificial teeth by Type III Gold and Nickel crome alloy thus construdting a full denture and therefore comparing the above case with abrasion of Natural teeth. The result were as follows : 1. The abrasion of Natural teeth and the abrasion of full denture constructed by Type III gold has a close resemblance. 2. The one that has the hightest degree of abrasion is full denture that's using, with acrylic resin teeth, maxillary and mandibular And the lowest abrasion is natural teeth-natural teeth. 3. In case of single denture, that's opposing to natural teeth, the one that has the hightest degree of abrasion is a full denture that's using Acrylic resin teeth and the lowest abrasion is a full denture that's forming occlusal surface by Type III gold. 4. The single denture, which is opposing to type III gold teeth, was abraded above everything by full denture which is constructed by porcelain teeth. 5. In the same teeth, the abrasion of mandibular teeth was greater than that of mandibular teeth was greater than that of maxillary teeth. 6. The abrasion degree of Acrylic resin teeth has no direct mutual connection with material hardness which is opposing to.

  • PDF

Linear measurement evaluation according to UV-type ultrasonic cleaning of artificial teeth for temporary dentures manufactured using a light-curing type printer produced by a DLP printer (광중합형 프린터로 제작한 임시 의치용 인공치아의 UV형 초음파 세척에 따른 선형측정 평가)

  • Dong-Yeon Kim;Gwang-Young Lee
    • Journal of Technologic Dentistry
    • /
    • v.46 no.1
    • /
    • pp.8-14
    • /
    • 2024
  • Purpose: This study compares the deformation of traditional resin dentures to resin dentures printed with digital light processing (DLP). Methods: Eleven edentulous research models were developed. Ten of them were made with traditional resin dentures. The remaining one was prepared for scanning and 3D (three-dimensional) printing. Ten traditional resin dentures were made, with the remaining artificial teeth created using 3D software and a DLP printer. Traditional resin dentures, 3D printed resin denture artificial teeth, and a denture base with artificial teeth were all cleaned simultaneously in an ultrasonic cleaner for 3 minutes. Three groups were assigned four artificial tooth measurement points, which were then measured with digital calipers. The measured data was analyzed using descriptive statistics. The significance test was conducted using a nonparametric test Kruskal-Wallis test due to the small number of specimens (α=0.05). Results: The traditional resin dentures had the lowest strain rate at -0.04%, while the group that manufactured only artificial teeth had the highest strain rate at -0.09%. However, no statistically significant difference was observed between the 3 groups (p>0.05). Conclusion: During ultraviolet-type ultrasonic cleaning, traditional resin dentures (TD group) and denture base with artificial teeth made of DLP (DD group) demonstrated stable durability, whereas the artificial teeth made of DLP (AD group) with only artificial teeth did not show a good deformation rate.

A Study on the Shear Bond Strength between Various Denture Bases Resin and Artificial Resin Teeth (수종의 의치상 레진과 레진치아의 전단결합강도에 관한 연구)

  • Lee, Sang-Wook;Cho, In-Ho;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.59-67
    • /
    • 2005
  • The bond strength of denture base resin and resin teeth, is an important factor in the long term prognosis of dentures. The purpose of this study is to find an appropriate combination of commercial denture base resin and artificial resin teeth according to shear bond strength. In this study, the shear bond strength of various denture base resins (Vertex $RS^{(R)}$(Dentimax Ziest, Holland), $PERform^{(R)}$(Hedent GmbH., Germany), SR $IVOCAP^{(R)}$(Ivoclar AG, Schaan, Liechtenstein)) and resin teeth (SR Orthosit PE(Ivoclar AG, Schaan, Liechtenstein), $Trubyte^{(R)}$ $Biotone^{(R)}$(Dentsply, U.S.A.)) was evaluated. 1. In comparison of denture resin, the shear bond strength increased in the order of $IVOCAP^{(R)}$, $PERform^{(R)}$, Vertex $RS^{(R)}$. 2. In resin teeth, $Trubyte^{(R)}$ $Biotone^{(R)}$ showed higher strength, but there was no statistical difference between the groups. 3. According to loading direction, the lingual showed higher strength, but there was no statistical difference. 4. When using SR Orthosit PE, SR $IVOCAP^{(R)}$ showed significantly higher shear bond strength(p<0.05). 5. Fracture tendancy showed more cohesive fractures(59) than adhesive failures(13). $IVOCAP^{(R)}$ showed the most superior results statistically. $Trubyte^{(R)}Biotone^{(R)}$ showed the highest shear bond strength. When using the SR Orthosit PE, it is thought that $IVOCAP^{(R)}$ would present the most superior results.

Shear bond strength between CAD/CAM denture base resin and denture artificial teeth when bonded with resin cement

  • Han, Sang Yeon;Moon, Yun-Hee;Lee, Jonghyuk
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.5
    • /
    • pp.251-258
    • /
    • 2020
  • PURPOSE. The bond strengths between resin denture teeth with various compositions and denture base resins including conventional and CAD/CAM purposed materials were evaluated to find influence of each material. MATERIALS AND METHODS. Cylindrical rods (6.0 mm diameter × 8.0 mm length) prepared from pre-polymerized CAD/CAM denture base resin blocks (PMMA Block-pink; Huge Dental Material, Vipi Block-Pink; Vipi Industria) were bonded to the basal surface of resin teeth from three different companies (VITA MFT®; VITA Zahnfabrik, Endura Posterio®; SHOFU Dental, Duracross Physio®; Nissin Dental Products Inc.) using resin cement (Super-Bond C&B; SUN MEDICAL). As a control group, rods from a conventional heat-polymerizing denture base resin (Vertex™ Rapid Simplified; Vertex-Dental B.V. Co.) were attached to the resin teeth using the conventional flasking and curing method. Furthermore, the effect of air abrasion was studied with the highly cross-linked resin teeth (VITA MFT®) groups. The shear bond strengths were measured, and then the fractured surfaces were examined to analyze the mode of failure. RESULTS. The shear bond strengths of the conventional heat-polymerizing PMMA denture resin group and the CAD/CAM denture base resin groups were similar. Air abrasion to VITA MFT® did not improve shear bond strengths. Interfacial failure was the dominant cause of failure for all specimens. CONCLUSION. Shear bond strengths of CAD/CAM denture base materials and resin denture teeth using resin cement are comparable to those of conventional methods.

COMPARISON OF THE PHYSICAL PROPERTIES OF FOUR KINDS OF ACRYLIC RESIN DENTURE TEETH (4종 아크릴릭 레진 인공치의 물리적 성질에 관한 비교)

  • Hwang, Jong-Woo;Chung, Chae-Heon;Ko, Yeong-Mu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.2
    • /
    • pp.210-230
    • /
    • 1995
  • To compare the wear resistance of four kinds of commercial acrylic resin teeth [SR-Orthosit PosterioresR(Ivoclar Co., Liechtenstein), Endura PosteriorR(Shofu Inc. Japan), trubyte IPN teethR(Dentsply International Inc., York,), Trubyte BiotoneR(dentsply Inermational Inc. Brazil) by means of the toothbrush abrasion method, the artificial resin teeth were embedded in epoxy resin with the occlusal surfaces aligned in one plane for a total of 40 blocks. There after, each lock was mounted in the arm of the toothbrush abrasion machine(K 236, Japan). Wear measurements were made on the three preconditioned states. Those were as follows : no treatment specimens, thermocycled specimens, and thermocycled specimens which were immeresed applied load of 400g during the buring the brushing cycle. At the end of the 30,000-stroke cycle, each specimen was removed, and weighed. The microhardness of four kinds of commercial resin teeth were determined by means of microhardness tester. Microhardness tests were performed on te no treatment specimens, thermocycled specimens, and thermocycled specimens with immersion in the denture cleansing solution. Finally, the comparison of thermal properties were perfomed using differential scanning calorimeter(DSC-1500). The following results were obtained : 1. In the case of no treatment teeth, the wear amount of endura Posterior(EN) was the greatest among the others(p<0.01), and the wear amount of three kinds of artificial resin teeth was increased in the order of Trubyte IPN teeth(IN), Trubyte Biotone(BN), SR-Orthosit Posteriores(SN) but there was no statistic significance(p>0.01). 2. The wear amount of Trubyte IPN teeth(IT) and Trubyte Biotone(BT), was increased due to thermocycling effect, but that of Endura Posteriores(ET) was decreased conversely(p<0.01). 3. Except for the SR-Orthosit Posteriores(STC), the wear amount of three kinds of artificial resing teeth(that is, ETC, ITC, BTC) was increased due to denture cleansing solution$(Cledent^R)$, but there was no statistic significance(p>0.01). But the wear amount of the SR-Orthosit Posteriores(STC) was the greatest among the others(p<0.01). 4. The wear amount of toothbrush was the greatest in case of contact with occlusal surface of SROrthosit Posteriores resin teeth(p<0.01). 5. the microhardness values(KHN) of the SR-Orthosit Posteriores was the highest among the experimental artificial resin teeth(p<0.01). 6. There was no relationship between microhardness valuse(KHN) and wear amount of four kinds of experimental artificial resin teeth(p<0.01). 7. The differential canning calorimetric property of four kinds of artificial resin teeth did not show endothermal or exothermal peak in the range of $100^{\circ}C$

  • PDF

Effect of surface treatment on shear bond strength between artificial resin teeth and 3D printing denture base resin (인공치의 표면처리가 3D 프린팅 의치상레진과의 전단결합강도에 미치는 영향)

  • Choi, Jeehye;Lee, Younghoo;Hong, Seoung-jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kwon, Kung-Rock;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.300-305
    • /
    • 2020
  • Purpose: The purpose of this study is to compare the shear bond strength of 3D printing denture base resin according to surface treatment of artificial teeth. Materials and methods: 3D printing denture base resin was fabricated as specimens using 3D printer. The experimental group divided the surface treatment of artificial teeth into five groups according to the application of sandblasting and primer (n=10). Shear bond strengths between denture base and artificial teeth were measured by universal testing machine. All measurements were analyzed by one-way ANOVA and Turkey test (α=.05). Fracture mode of each specimen was analyzed. Microscopic evaluation was conducted by using a scanning electron microscope. Results: Unsurfaced treated group represented the lowest value. The primer groups had significantly higher result values (P<.05). Most specimens of the primer groups had cohesive failure. Conclusion: In 3D printing denture base resin group, mechanical and chemical surface treatment of artificial teeth has increased the shear bond strength. Therefore, if dentures are produced using 3D printing, proper mechanical and chemical treatment of artificial teeth is necessary for adhesion of dentures and artificial teeth.

Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization (광중합용 DLP 프린터로 제작한 전악 인공치아의 UV-C 초음파 세척에 따른 체적 안정성 평가)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.84-92
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the dimension safety evaluation between a general ultrasonic cleaner and an ultrasonic cleaner equipped with UV-C (ultraviolet-C). Methods: An edentulous model was prepared. A denture base and an occlusal rim were fabricated, and scanning was performed. After scanning, a denture base and full arch artificial teeth were designed. The full arch artificial teeth were printed using a three-dimensional printer (n=10). The residual resin was washed with alcohol and then scanned (reference data). The printed specimens were classified and cleaned using a general ultrasonic cleaner (GU group) and an ultrasonic cleaner equipped with UV-C (UC group). After each washing, a rescan was performed (scan data). Reference data and scan data were superimposed using overlapping software. Data were statistically analyzed using the Mann-Whitney test (α=0.05). Results: In the deviation values of full arch artificial teeth, the GU group showed a high deviation of 18.02 ㎛ and the UC group showed a low deviation of 15.02 ㎛. The two groups demonstrated a statistically significant difference (p<0.05). Conclusion: Full arch artificial teeth prepared using photopolymerized resin were deformed according to the temperature of water generated in the ultrasonic cleaner. It is judged that there is no deformation according to the UV-C ultrasonic cleaner.