• 제목/요약/키워드: Artificial lighting

검색결과 210건 처리시간 0.025초

인간공학 기준에 의한 차세대형 주제어실 조명설계 및 조도 휘도 분석- 중국 광동 Ling Ao Phase II NPP MCR 환경디자인을 중심으로- (A Study on Lighting Design and Illumination and Luminance of in Advanced type Control Room by the Standard of Ergonomics - Focused on Ling Ao Phase II NPP MCR Environmental Design in Guangdong, China-)

  • 백승경;이승훈
    • 대한인간공학회지
    • /
    • 제27권2호
    • /
    • pp.73-82
    • /
    • 2008
  • Currently an office in information society is advanced to a digitalized VDT office. The VDT office has a natural luminous system prioritizing visual perception and so importance of lighting design by artificial lighting is emphasized in the VDT office. The purpose of the study is to analyze Illumination and Luminance for lighting design by the standard of ergonomics in the VDT office. The study analyzed Illumination and Luminance in the main control room of an nuclear power plant needing a design of ergonomics ACR(Advanced Control Room) type Ling Ao phase II NPP MCR in Guangdong, China. The study examined the relativity of ACR characteristics to its operator's duties and set up an outline of lighting design, the standard of ergonomics and input data for the analysis. Thus, the study examined appropriateness with the standard of ergonomics setting up the analyzed Illumination and Luminance and drew a conclusion.

수직형 LED 조명의 색상 및 점멸에 따른 눈부심 주관평가 (Subjective Evaluation of Glare for Blinking and Colors of Vertical LED Lighting)

  • 정현지;김인태;최안섭
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.22-30
    • /
    • 2015
  • Currently, in South Korea, 'Light Pollution Prevention Act by Artificial Lighting' has been enforced. For advertising lighting, it is limited based on only the light-emitting luminance. Luminance is a concept related to the glare. Not only the luminance of the light source, but also glare is affected depending on some situations like blinking, luminance contrast, background illuminance. This study conducted glare subjective evaluation with brightness, color, and blinking by looking at the LED lighting box. The results showed that the glare indexes were higher about 2 times in a decrease of background illuminance from 100lx to 0lx. The glare index of R, G, B light was higher than that of white light. The average glare index of the blue light was higher about 8 times compared to 2,700K. And the blink rate had little effect on the glare, but it affected the irritation. Therefore, the glare effect of light color and blinking needs to be considered for the standard of luminous environment.

회귀분석을 통한 창원시 중학교 전력소비량 예측에 관한 연구 (A Study on Prediction of Power Consumption Rate of Middle School Building in Changwon City by Regression Analysis)

  • 조형규;박효석;최정민;조성우
    • 교육녹색환경연구
    • /
    • 제12권2호
    • /
    • pp.61-70
    • /
    • 2013
  • As the existing school building power consumption is expressed by total power consumption, in the view of energy saving is disadvantage. The the power consumption of school building is divided as cooling, heating, lighting and others. The cooling power consumption, heating power consumption, lighting power consumption can be calculated using real total power consumption that gained from Korea Electric Power Corporation(KEPCO). The power consumption for cooling and heating can be calculated using heat transmittance, wall area and floor area, and for lighting is calculated by artificial lighting calculation. but this calculation methods is difficult for laymen. This study was carried out in order to establish the regression equation for cooling power consumption, heating power consumption, lighting power consumption and other power consumption in school building. In order to verify the validity of the regression equation, it is compared regression equation results and calculation results based on real power consumption. As the results, difference between regression result and calculation results for cooling and heating power consumption showed 0.6% and 3.6%.

주광량의 변화에 따른 LED조명 제어를 통한 에너지 절감량 분석에 관한 연구 (A Study on Energy Savings Analysis by Controling LED Lighting according to the Change of the Amount of Daylight)

  • 함원태;채수용;한수빈;김흥근;정학근
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.522-528
    • /
    • 2012
  • Currently, the energy consumption of electric lighting in an office building is accounted for more than 30% of the total energy consumption. In order to reduce the energy consumed by the indoor lighting, the daylight as a natural energy resource can play an important role in energy savings. The daylight can have positive impacts on improvement of work efficiency and productivity, and also make people feel more psychologically stable. Moreover, by using the daylight, we can definitely reduce the energy consumption in office buildings. Thus, the purpose of this study is to determine the LED dimming ratio depending on the ratio by calculating the amount of artificial illumination required according to the change of daylight by using the light simulation software that can quantify and visualize the performance of daylight. As a result, the energy savings could be obtained up to 30%.

  • PDF

Design and Implementation of Green Coastal Lighting System for Entrance to Coastal Pier

  • Jae-Kyung Lee;Jae-Hong Yim
    • 한국항해항만학회지
    • /
    • 제47권2호
    • /
    • pp.85-92
    • /
    • 2023
  • The hardware of an LED lighting control system for coastal lighting at coastal pier entrance consists of a power supply unit, an AVR control unit, a CLCD output unit, an LED control unit, a scenario selection switch unit, and an operation speed display unit. It is made of an 8-channel. The CPU used ATmega128 and the FET was used to control the current signal. To operate the CPU, DC 12V was converted to DC 5V using a regulator 7805. A heat sink was used to remove heat generated in the FET. By connecting the load LED module to the manufactured 8-channel LED lighting control system, the operation was confirmed through various production scenarios. In addition, a control system was designed to show the most suitable color for the atmosphere of the coastal pier according to the input value of temperature and illumination using a fuzzy control system. Computer simulation was then conducted. Results confirmed that fuzzy control did not need to store many data inputs due to characteristics of artificial intelligence and that it could efficiently represent many output values with simple fuzzy rules.

Measurement System of Photosynthetic Photon Flux Distribution and Illumination Efficiency of LED Lamps for Plant Growth

  • Lee, Jae Su;Kim, Yong Hyeon
    • Journal of Biosystems Engineering
    • /
    • 제37권5호
    • /
    • pp.314-318
    • /
    • 2012
  • Purpose: This study was conducted to develop a measurement system for determining photosynthetic photon flux (PPF) distribution and illumination efficiency of LED lamps. Methods: The system was composed of a linear moving sensor part (LMSP), a rotating part to turn the LMSP, a body assembly to support the rotating part, and a motor controller. The average PPF of the LED lamp with natural cooling and water cooling was evaluated using the measurement system. Results: The PPF of LED lamp with water cooling was 3.1-31.7% greater than that with natural cooling. Based on the measured value, PPF on the horizontal surface was predicted. Illumination efficiency of the LED lamp was slightly increased with water cooling by 3.4%, compared with natural cooling. A simulation program using MATLAB was developed to analyze the effects of the vertical distance from lighting sources to growing bed, lamp spacing, and number of LED lamps, on the PPF distribution on the horizontal surface. The uniformity of the PPF distribution of the LED lamps was fairly improved with 15 cm spacing, as compared to the 5 cm spacing. By simulation, PPF of $217.0{\pm}27.9{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ was obtained at the vertical distance of 40 cm from six LED lamps with 12 cm spacing. This simulated PPF was compared to the measured one of $225.9{\pm}25.6{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. After continuous lighting of 346 days, the relative PPF of LED lamps with water cooling and natural cooling was decreased by 6.6% and 22.8%, respectively. Conclusions: From these results, it was concluded that the measurement system developed in this study was useful for determining PPF and illumination efficiency of artificial lighting sources including LED lamp.

인공지능 디바이스의 조명효과에 대한 사용자의 감정 평가 분석 (Analysis of Users' Emotions on Lighting Effect of Artificial Intelligence Devices)

  • 현윤아;반영환;유훈식
    • 감성과학
    • /
    • 제22권3호
    • /
    • pp.35-46
    • /
    • 2019
  • 인공지능기술은 사용자의 언어, 목소리 톤, 표정을 인지하고 학습하여 다양한 맥락에서 사용자의 감정에 대응할 수 있도록 발전하고 있다. 여러 인공지능 기반 서비스 중에서 특히 사용자와의 커뮤니케이션이 중요한 서비스 다수는 감정을 표현하는 인터랙션을 제공한다. 그러나 인공지능 시스템의 감정을 표현하는 수단으로서의 비언어적 인터랙션에 관한 연구는 아직 미비하다. 이에 조명효과 중 특히 색상과 깜빡임 운동을 중심으로 인공지능 디바이스의 감성 인터랙션을 연구하였다. 본 연구에서 구현한 인공지능 디바이스 프로토타입은 red, yellow, green, blue, purple, white 6가지의 조명 색상과 느림, 중간, 빠른 세 단계 속도의 깜빡임 효과로 감정을 표현한다. 프로토타입을 활용하여 20대부터 30대 남녀 50명을 대상으로 인공지능 디바이스의 색상별, 속도별 조명 효과가 표현하고 있는 감정에 응답하는 실험을 진행하였다. 실험 결과 각 조명 색상은 기존 색채감성연구에서 드러난 감성적 이미지와 대체로 유사한 감정을 나타내는 것으로 평가되었다. 조명의 깜빡임 속도는 감정의 각성과 밸런스의 변화에 영향을 주었으며, 이때 각성의 변화 양상은 모든 색상에서 유사한 기조를 보였다. 밸런스 변화 양상은 기존 색채감성연구의 감성적 이미지와 어느 정도 관련이 있지만 색상 별 차이가 있는 것으로 관찰되었다. 인공지능 시스템을 탑재한 사물의 종류와 인공지능 디바이스가 점점 다양해지는 현 시점에서, 본 연구결과는 조명을 통한 인공지능의 감성 인터랙션을 설계할 때 기여할 수 있을 것으로 기대된다.

인공광하의 풍동내에서 기류속도가 가지 플러그묘의 생장에 미치는 영향 (Effects or air current speeds on the growth or eggplant plug seedlings in a wind tunnel under artificial lighting)

  • 김용현
    • 생물환경조절학회지
    • /
    • 제7권1호
    • /
    • pp.9-14
    • /
    • 1998
  • 본 연구에서는 인공광하의 풍동내에서 기류속도와 생육실내의 위치가 플러그묘 개체군의 생장에 미치는 효과를 분석하였다 기류속도가 증가하면 모개체군내에서의 상대습도는 감소하나, 포차는 증가한다. 이에 따라 증산이 활발하게 이루어져 잎에서의 수분포텐셜이 저하되며 묘개체군 위에서 공기역학적 저항이 감소함에 따라 확산계수가 높게 나타난다. 그 결과로서 0.93m.s$^{-1}$의 기류속도에서 줄기 길이, 줄기직경에 대한 줄기 길이의 비, 초장, 엽수는 유의성이 인정될 만큼 작게 나타났다. 묘개체군의 순광합성속도는 기류속도의 증가와 함께 증가되면서 0.7~0.9 m.s$^{-1}$에서 높게 나타났다. 생육실내의 위치 즉 기류의 진행방향을 따라 줄기 직경과 지하부 건물 중은 감소하였으나, 줄기 직경에 대한 줄기 길이의 비와 엽면적은 증가하는 것으로 나타났다. 이밖에 플러그묘의 생체중 또는 건물 중에 대한 T/R비는 기류속도의 변화와 무관하게 각각 2.8~3.5, 3.2~3.9로서 비슷하게 나타났으나, 건물율은 지상부에서 8.1~9.4, 지하부에서 10.1~10.9로서 지하부에서 다소 높게 나타났다. 그러므로 기류속도의 크기와 기류의 진행방향에 따라 묘개체군 위에서의 확산계수가 다르게 나타나며 이로 인하여 모개체군의 생장 차이가 나타남을 알 수 있다. 따라서 식물모공장과 같이 인공광을 이용한 반폐쇄 식물생산 시스템에서 품질이 균일한 모를 생산하려면 묘개체군의 미기상에 기초한 적정 환경조건의 확립이 요구된다.

  • PDF

컴퓨터실에 있어서 VDT작업공간의 조명환경 개선에 관한 연구 (A Study on the Lighting Environment Improvement of the VDT Workspaces in Computer Room)

  • 정진현
    • 교육시설
    • /
    • 제4권3호
    • /
    • pp.31-39
    • /
    • 1997
  • The purpose of this study was to improve the lighting environment of the VDT workspaces in computer laboratory. This study was carried out through the field measurements on the computer laboratory and a survey using the questionnaire about the VDT workspaces. The major findings of the study were as follows: (1) It was unbalanced among the illumination, luminance, and color distributions in the the VDT workspaces. (2) The difference of brightness between the CRT screen and its surroundings have presented on the whole unbalanced. (3) It was proved that the artificial light source of the ceiling lighting should use the parabolic louver luminaire limiting the radiant luminance.

  • PDF

RADIANCE 프로그램을 이용한 오피스 건축물에서의 에너지 절감율 예측을 위한 BIN Method 검토 (Assessment of BIN Method to Predict Energy Saving in Office Building Using the RADIANCE Program)

  • 홍성관;박병철;최안섭;이정호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.154-159
    • /
    • 2008
  • Daylight is an important component for human and energy saving. Also, available daylight in inside provides positive influence on psychological and physiological aspects as well as good visual environment. It is important to lighting design for office building not only designing for artificial lighting but also using daylight for energy savings. Therefore, lighting designers and architectures must consider the effects of the daylight for human environment and energy savings. The BIN Method is one of the methods to predict energy savings using computer simulation but it spends more time than expectation. So, this study performs to simulate a simple space using the RADIANCE for examination and simplification of the BIN Method.

  • PDF