• Title/Summary/Keyword: Artificial heart

Search Result 332, Processing Time 0.032 seconds

Application of a Single-pulsatile Extracorporeal Life Support System for Extracorporeal Membrane Oxygenation -An experimental study - (단일 박동형 생명구조장치의 인공폐 적용 -실험연구-)

  • Kim, Tae-Sik;Sun, Kyung;Lee, Kyu-Baek;Park, Sung-Young;Hwang, Jae-Joon;Son, Ho-Sung;Kim, Kwang-Taik;Kim. Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.37 no.3
    • /
    • pp.201-209
    • /
    • 2004
  • Extracorporeal life support (ECLS) system is a device for respiratory and/or heart failure treatment, and there have been many trials for development and clinical application in the world. Currently, a non-pulsatile blood pump is a standard for ECLS system. Although a pulsatile blood pump is advantageous in physiologic aspects, high pressure generated in the circuits and resultant blood cell trauma remain major concerns which make one reluctant to use a pulsatile blood pump in artificial lung circuits containing a membrane oxygenator. The study was designed to evaluate the hypothesis that placement of a pressure-relieving compliance chamber between a pulsatile pump and a membrane oxygenator might reduce the above mentioned side effects while providing physiologic pulsatile blood flow. The study was performed in a canine model of oleic acid induced acute lung injury (N=16). The animals were divided into three groups according to the type of pump used and the presence of the compliance chamber, In group 1, a non-pulsatile centrifugal pump was used as a control (n=6). In group 2 (n=4), a single-pulsatile pump was used. In group 3 (n=6), a single-pulsatile pump equipped with a compliance chamber was used. The experimental model was a partial bypass between the right atrium and the aorta at a pump flow of 1.8∼2 L/min for 2 hours. The observed parameters were focused on hemodynamic changes, intra-circuit pressure, laboratory studies for blood profile, and the effect on blood cell trauma. In hemodynamics, the pulsatile group II & III generated higher arterial pulse pressure (47$\pm$ 10 and 41 $\pm$ 9 mmHg) than the nonpulsatile group 1 (17 $\pm$ 7 mmHg, p<0.001). The intra-circuit pressure at membrane oxygenator were 222 $\pm$ 8 mmHg in group 1, 739 $\pm$ 35 mmHg in group 2, and 470 $\pm$ 17 mmHg in group 3 (p<0.001). At 2 hour bypass, arterial oxygen partial pressures were significantly higher in the pulsatile group 2 & 3 than in the non-pulsatile group 1 (77 $\pm$ 41 mmHg in group 1, 96 $\pm$ 48 mmHg in group 2, and 97 $\pm$ 25 mmHg in group 3: p<0.05). The levels of plasma free hemoglobin which was an indicator of blood cell trauma were lowest in group 1, highest in group 2, and significantly decreased in group 3 (55.7 $\pm$ 43.3, 162.8 $\pm$ 113.6, 82.5 $\pm$ 25.1 mg%, respectively; p<0.05). Other laboratory findings for blood profile were not different. The above results imply that the pulsatile blood pump is beneficial in oxygenation while deleterious in the aspects to high pressure generation in the circuits and blood cell trauma. However, when a pressure-relieving compliance chamber is applied between the pulsatile pump and a membrane oxygenator, it can significantly reduce the high circuit pressure and result in low blood cell trauma.

Transformation of Adult Mesenchymal Stem Cells into Cardiomyocytes with 5-azacytidine: Isolated from the Adipose Tissues of Rat (성체 백서의 지방조직에서 추출한 중간엽 줄기세포의 5-azacytidine을 이용한 심근세포 분화 유도)

  • Choe Ju-Won;Kim Yong-In;Oh Tae-Yun;Cho Dai-Yoon;Sohn Dong-Suep;Lee Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.511-519
    • /
    • 2006
  • Background: Loss of cardiomyocytes in the myocardial infarction leads to regional contractile dysfunction, and necrotized cardiomyocytes in infracted ventricular tissues are progressively replaced by fibroblasts forming scar tissue. Although cardiomyoplasty, or implantation of ventricular assist device or artificial heart was tried in refractory heart failure, the cardiac transplantation was the only therapeutic modality because these other therapeutic strategies were not permanent. Cell transplantation is tried instead of cardiac transplantation, especially bone marrow is the most popular donated organ. But because bone marrow aspiration procedure is invasive and painful, and it had the fewer amounts of cellular population, the adipose tissue is recommended for harvesting of mesenchymal stem cells. Material and Method: After adipose tissues were extracted from abdominal subcutaneous adipose tissue and intra-abdominal adipose tissue individually, the cellular components were obtained by same method. These cellular components were tried to transformation with the various titers of 5-azacytidine to descript the appropriate concentration of 5-azacytidine and possibility of transformation ability of adipose tissue. Group 1 is abdominal subcutaneous adipose tissue and Group 2 is intra-abdominal adipose tissue-retroperitoneal adipose tissue and omentum. Cellular components were extracted by collagenase and $NH_4Cl$ et al, and these components were cultured by non-induction media - DMEM media containing 10% FBS and inducted by none, $3{\mu}mol/L,\;6{\mu}mol/L,\;and\;9{\mu}mol/L$ 5-azacytidine after the 1st and 2nd subculture. After 4 weeks incubation, tile cell blocks were made, immunostaining was done with the antibodies of CD34, heavy myosin chain, troponin T, and SMA. Result: Immunostaining of the transformed cells for troponin T was positive in the $6{\mu}mol/L\;&\;9{\mu}mol/L$ 5-azacytidine of Group 1 & 2, but CD34 and heavy myosin chain antibodies were negative and SMA antibody was positive in the $3{\mu}mol/L\;&\;6{\mu}mol/L$ 5-azacytidne of Group 2. Conclusion: These observations confirm that adult mesenchymal stem cells isolated from the abdominal subcutaneous adipose tissues and intra-abdominal adipose tissues can be chemically transformed into cardiomyocytes. This can potentially be a source of autologous cells for myocardial repair.

Physiologic Changes During Bronchoscopy in Mechanically Ventilated Patients (기계환기중인 환자에서 기관지내시경 검사에 따른 생리적 변화)

  • Pyun, Yu Jang;Suh, Gee Young;Koh, Won-Jung;Yu, Chang-Min;Jeon, Kyeongman;Jeon, Ik Soo;Ham, Hyoung Suk;Kang, Eun Hae;Chung, Man Pyo;Kim, Hojoong;Kown, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.5
    • /
    • pp.523-531
    • /
    • 2004
  • Background : Bronchoscopy in patients on mechanical ventilation is being performed much more frequently. However, there is little data on the changes in physiologic parameters and no established mechanical ventilation protocol during bronchoscopy. A decreasing or the removal of positive end-expiratory pressure (PEEP) during bronchoscopy may precipitate severe hypoxemia and/or derecruitment. Methods : Our standardized mechanical ventilation protocol, without changing the PEEP level, was used during bronchoscopy. The physiological parameters were measured during the bronchoscopic procedure. Results : During bronchoscopy, respiratory acidosis, elevation of peak pressure, elevation of heart rate and auto-PEEP were developed, but were reversible changes. Procedure-related gross barotraumas or other severe complications did not developed. Conclusion : No serious complications developed during bronchoscopy under our standardized mechanical ventilation protocol when the PEEP level remained unchanged. The procedure time should be kept to a minimum to decrease the exposure time to undesirable physiological changes.

Egg Development and Morphology of Larva and Juvenile of the Konoshiro Gizzard Shad, Konosirus punctatus (전어(Konosirus punctatus)의 난발생 및 자치어 형태 발달)

  • Kim, Kwan-Seok;Han, Kyeong-Ho;Lee, Jung-Hyun;Lee, Sung-Hun;Kim, Chun-Chel;Ko, Hyun-Jung;Jeong, Kwan-Sik
    • Development and Reproduction
    • /
    • v.11 no.2
    • /
    • pp.127-135
    • /
    • 2007
  • In order to monitor the developmental features of embryos, larvae, and juveniles of Konoshiro Gizzard Shad Konosirus punctatus, the fertilized eggs were gotton using artificial insemination. Konosirus punctatus were caught in Mankyung-myeon, Kimjae, Jeollabuk-do at June of 2004, and experiments were carried out in Ichthyology laboratory in Chonnam National University. Konosirus punctatus spawned draft egg from March to June. The fertilized eggs were cultured in $19.0{\sim}23.0^{\circ}C$(mean, $21.2^{\circ}C)$. The eggs had spherical shape and the diameter is $1.14{\sim}1.34\;mm$(mean, 1.21 mm). The lens began to appear from 35 hr 53 min after fertilization. At the moment, the movement of larvae was more active, and the tail was separated completely from yolk, the heart had forms, and melanophore appeared. Hatching was observed from 37 hr 10 min after fertilization. The total length of the hatched larvae was $4.26{\sim}5.30\;mm$(mean, 4.96 mm), but the mouth and anus were not opened at the time when the larva had yolk sack, and had $22{\sim}27$ myometium, and the anus located just abdominal front of the tail fin, and melanophore accumulated in the eye. Post-larvae used yolk completely after 2 day of hatching, and the total length was $4.96{\sim}5.74\;mm$(mean, 5.24 mm). From 16 days after hatching, the tail had curved tail end, and appeared the stems for pectoral, dorsal, and caudal fins. At 53 days after hatching, the total length of post-larvae was $27.11{\sim}34.09\;mm$(mean, 30.11 mm), and the frontal part of head developed like an adult one. At this time, fins and body are transferred to those of adult Konosirus punctatus. Fishes have a different shape and location of melanophore even in the same family. This research was tried to elucidate the early developmental features of Konosirus punctatus, together with species-specific pattern of melanophore.

  • PDF

Development of Biocompatible Vascular Graft -Endothelialization of Small Vascular Graft- (생체적합성 인조혈관의 개발 -혈관내피화 인조혈관-)

  • 김형묵;이윤신
    • Journal of Chest Surgery
    • /
    • v.29 no.4
    • /
    • pp.373-380
    • /
    • 1996
  • Prevention of thromboembolism is the most important task in the development of bioconpatible small caliber artificial vascular graft. In normal vessels, vascular endothelial cells maintain homeosatsis by secreting numerous factors. The aim of this study is to develope a method which Improves biocompatibility of small caliver polyurethane graft using endothelial cell culture technique, and ev luate the efTectiveness of extracelluar matrix for endothelization which was produced by cultured fibroblast. Methods ; Multiporous polyurethane tube of 3 mm diameter, 0.3 mm thickness was manufactured for vascular graft. Three mongrel dogs were intubated and internal jugular veins removed. Extracelluar matrix produced by cultured flbrobast which was obtained from dog's internal jugular vein were coated to the polyurethane graft. Then, endothelial cells extracted from Jugular vein were cultured and fixed on the extracelluar matrix layer of vascular graft. Endothelial cell coated vascular grafts were implanted to the carotid arteries of experimental dogs as interposed autograft. Implanted grafts were removed after 3 and 6 weeks. As a control, PTFE graft was interposed on carotid artery. These experiments demonstrated that extracelluar matrix produced by fibroblast can afford a base for endothelial cell linings of polyurethane graft. Although thrombosis were developed on autografted en othelial cell coated graft, 33% opening was noticed, and showed less adhesion to adjacent tissue layer. These findings suggest that fiboblast produced extracelluar matrix which can be used for edothelial cell lining vascular graft, and by improving the cultured endothelial cell function, there will be a new modality for reducing thrombosis on small vascular graft.

  • PDF

Comparison of Two Methods of Recruiting the Acutely Injured Lung (급성 폐손상에서 폐를 Recruit시키는 방법간의 비교 연구)

  • Suh, Gee-Young;Kang, Kyeong-Woo;Park, Sang-Joon;Kim, Ho-Choel;Young, Lim-Si;Chung, Man-Pyo;Han, Jeong-Ho;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.500-512
    • /
    • 2000
  • Background : To evaluate the efficacy of two methods of obtaining lung recruitment to reduce ventilator-induced lung injury(VILI). Methods : Fifteen New-Zealand white rabbits were ventilated in the pressure-controlled mode while maintaining constant tidal volume(10 ml/kg) and fixed respiration rate. Lung injury was induced by repeated saline lavage (PaO2<100 mmHg), and the pressure-volume curve was drawn to obtain Pflex. The animals were then randomly assigned to three groups and ventilated for 4 hours. In the control group(n=5), positive end-expiratory pressure(PEEP) less than that of Pflex by 3 mmHg was applied throughout the study. In the recruitment maneuver(RM) group(n=5), RM(CPAP of 22.5 mmHg, for 45 seconds) was performed every 15 minutes in addition to PEEP level less than Pflex by 3 mmHg This phrase is unclear. In the Pflex group, PEEP of Pflex was given without RM. Gas exchange, lung mechanics, and hemodynamics parameters as well as pathology were examined. Results : 1) Both the control and RM groups showed decreasing tendency in PaO2 with time. There was significantly decreased PaO2 at 4 hr compared to Ihr(p<0.05). But in the Pflex group, PaO2 did not decrease with time(p<0.05 vs other groups at 3, 4 hr). PaCO2 did not show significant difference among the three groups. 2) There was no significant difference in static compliance and plateau pressure. Mean blood pressure and heart rate also did not show any significant difference among the three groups. 3) The pathologic exam showed significantly less neutrophil infiltration in the Pflex group than in the control group(p<0.05). There was borderline significant difference in hyaline membrane score among the groups (p= 0.0532). Conclusion : Although recruitment maneuver of the injured lung may be important in decreasing VILI, it alone may not be sufficient to minimize VILI.

  • PDF

Studies on Artificial Polyploid Forest Trees XIII -Some Morphological and Physiological Characteristics of Colchitetraploid Hibiscus syriacus L.- (인위배수성(人爲倍數性) 임목(林木)에 관(關)한 연구(硏究) XIII -Colchitetraploid인 자주무궁화와 단심무궁화의 몇 형태학적(形態學的) 및 생리학적(生理學的) 특성(特性)-)

  • Lee, Suk Koo;Kim, Chung Suk
    • Journal of Korean Society of Forest Science
    • /
    • v.32 no.1
    • /
    • pp.73-86
    • /
    • 1976
  • Two individuals ($sp_1$, $sp_2$) of purple and one individual ($sd_1$) of red hearted flower were selected from 18 years old Hibiscus syriacus trees obtained from the seeds treated with colchicine, and their morphological and physiological characteristics were investigated and following results were obtained. 1. The somatic chromosome number of the selected individuals, $sp_1$, $sp_2$, and $sd_1$ were 2n=160, while that of the check tree was 2n=80, indicating that the selected individuals, $sp_1$, $sp_2$ and $sd_1$ were tetraploid. 2. Peroxidase isoenzyme bands of high activity in selected individuals, $sp_1$, $sd_1$ and check tree were mostly in cathode, fixed band was f and v bands, and frequency of each band and their activity were not different between selected individuals, $sp_1$ and $sd_1$ and check tree. 3. The flowers of $sp_1$ individual were large in size and more dark purple than check tree's. The flowers of $sp_2$ individual were not increased in size, but they were dark purple and red heart at the base of the petal was expanded to 2/3 of the petal length. The flower of $sd_1$ individual was also large and some of the red lines from the petal base were extended to 2/3 of the petal length, which was much longer than those of the check tree. 4. Thickess of leaves, length of guard cells, diameter of pollens, wood fiber lengths and woody fiber widths were all increased in $sp_1$, $sp_2$ and $sd_1$ as compared to those of the check tree. 5. Survival percentage of cuttings was 80% with $sp_1$ and 36% with $sd_1$, and their growth performance were inferior to control in their second growing season.

  • PDF

Plant Regeneration of Bupleurum spp. through Somatic Tissue Culture (자호(紫胡)의 체세포조직배양(體細胞組織培養)에 의한 식물체재분화(植物體再分化))

  • Park, Cheol-Ho;Yu, Chang-Yeon;Kim, Dong-Wook;Cho, Hye-Kyeong;Park, Kyeong-Suk;Seo, Jeong-Sik;Ahn, Sang-Deuk;Jang, Byeong-Ho
    • Korean Journal of Medicinal Crop Science
    • /
    • v.2 no.1
    • /
    • pp.60-66
    • /
    • 1994
  • This study was conducted to determine the optimum conditions of inducing callus, proliferating callus, forming somatic embryos, and regenerating plantlets via somatic embryogenesis, for the purpose of producing artificial seeds and substantially developing plant factory technologies that can be employed to all seasons production of Bupleurum plants. Callus was efficiently induced from leaf tissues at three leaf stage in the MS medium supplemented with 2, 4-D 2mg /1 and thidiazuron(TDZ) 0.lmg /1. Callus induction from leaf tissues at maturity was mostly effective in the mixture of 2,4- D 2mg /1 and TDZ 1.0mg /1 while that from flower bud tissues was fairly good in the MS medium containing 2,4-D 1 or 2mg /1.Callus was formed in 15 to 20 days after culture initiation in the MS media supplemented with 2, 4- D 1-2mg /1 and TDZ 0.l-1.0mg /1. Such hormones as kinetin 3mg /1, GA 1mg /1, and the mixture of GA 1mg /1 and TDZ 1mg /1 effected markedly to proliferate the callus cells.The optimum temperature and light intensity for callus culture were found to be $25^{\circ}C$ and 3000 Lux, respectively. Direct plant regeneration from cultured callus was fairly made on hormone-free MS or half-strength MS medium. Somatic embryogenesis was most frequently observed in hormone-free media:60 somatic embryos per 20ml in MS medium and 28 somatic embryos per 20ml in half -strength MS medium. There were three stages-globular, heart, and torpedo-in development of somatic embryos, among which globular stage was more frequently observed in MS medium rather than in half-strength MS medium. Somatic embryos induced from suspension culture fairly differentiated a number of shoots and roots on hormone-free and half-strength MS solid medium.

  • PDF

A Study on the aesthetic of Calligraphy by Seok Jeon Hwang Wook (석전(石田) 황욱(黃旭)의 서예미학(書藝美學) 고찰)

  • Kim, Doyoung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.227-234
    • /
    • 2022
  • Seok Jeon Hwang Wook (18913~1999), a descendant of a traditional literary writer in the western part of Honam, did not join the flow of modern and contemporary calligraphy and painting. And throughout his life, he enjoyed himself without losing the appearance of a scholar, immersed himself in traditional calligraphy, and gained spotlight at his late age for his original hand grabbing calligraphy. Immediately after the Korean War, all of his property was lost due to his two sons' left-wing activities, causing great pain at home. Even in the most painful and difficult time in human history, he relied on brushes, poetry, and gayageum to keep his upright scholarly spirit and national love. And beyond the pleasures of the worldly senses, he played with self-satisfaction in the 'true pleasure(大樂)' without greed. In the course of his studies, he focused on honing the fonts of Wang Hui-ji, Gu Yang-sun, An Jin-gyeong, Jo Maeng-bu, and Xin-wi and Lee Sam-man without a special teacher. In particular, he faced a crisis of having to give up his brush due to tremor that came after his 60th birthday, but he showed a strong will. He transformed it into a new style of art, such as developing hand grabbing calligraphy(握筆法) with a strong and strong energy that no one could match. From 1965 to 1983, 'right hand grabbing calligraphy' was used, and from 1984 to 1993, 'left hand grabbing calligraphy' was used. She made her name as a calligrapher widely known in 1973 (age 76) with her first solo exhibition, The Calligraphy Exhibition commemorating her 60th wedding anniversary. His writing method is naturally rough and sloppy by breaking away from the previous calligraphy methods and artificial technique, and is unfamiliar yet full of muscle. And the calm, strong and rough chuhoegsa(錐劃沙) and the heavy yet majestic ininni(印印泥) individual handwriting expressed a strange feeling and achieved original Seokjeon calligraphy that went beyond the existing calligraphy writing methods, and his indomitable calligraphy spirit was As a unique existence in the history of calligraphy, he still remains as a model.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF