• 제목/요약/키워드: Artificial Teeth

검색결과 235건 처리시간 0.027초

ShadeScan$^{TM}$ System을 이용한 인공치의 색조분석 (SHADE ANALYSIS OF ARTIFICIAL TEETH USING SHADE $SCAN^{TM}$ SYSTEM)

  • 성채련;조인호;이종혁
    • 대한치과보철학회지
    • /
    • 제42권4호
    • /
    • pp.443-457
    • /
    • 2004
  • Purpose: The purpose of this study was to analyze and estimate whether each company may produce the color of artificial teeth as it stands, in the standard of vita classical shade guide using ShadeScan$^{TM}$ System. Material and methods: we chose the products of 6 companies -EFUCERA, IVOCLAR, ENDURA, TRUBYTE, DURADENT, and DURACROSS- estimated the shade value of each fixed point(cervical, body, and incisal area) of artificial tooth, and verified the equality among the samples from the same company. Results: First, the variation appeared significant at cervical and incisal area. It means that there were significant differences between cervical and incisal area although the most similar artificial teeth to the patients’natural teeth were provided. Second, the results in the body area showed that the variation between artificial and natural teeth was finite(p<0.05) in that area. Conclusion: it shows that the reproduction of colors of artificial teeth might be successful regarding the body is the most important part for a determination of the color of artificial teeth. However, more complements are necessary for the better reproduction of the color of artificial teeth between cervical and incisal area.

수복용 레진과 인공치아간의 결합강도 연구 (Study on shear bond strength of various composite resins to artificial denture teeth)

  • 박경모
    • 대한치과기공학회지
    • /
    • 제36권3호
    • /
    • pp.171-177
    • /
    • 2014
  • Purpose: The dental medicine has been preparing the custom-made service to meet the requirements of the aged society, while the average span of human life is growing more and more, and the full denture is a representative of them. It is causing great concern in these atmosphere of society, and demands for it are expected to increase. The full denture is a uniform combination of denture base and artificial teeth using polymerization, and is most influenced by change of physical properties of denture base and bonding strength with artificial teeth. Methods: In this study, the samples were made of composite resin combined with occlusion surface of artificial teeth undergone mechanically surface treatment to evaluate the bonding strength of composite resin for repairing artificial teeth. The resin teeth used in this study are 3 types artificial teeth. And 3 types of composite resins are used that are various polymerization resin. The shear strength of composite resins made in various polymerization ways to resin teeth was measured to evaluate bonding strength of artificial teeth to each composite resins. Results: Surface hardness's results on Trubyte Biotone(74.58Hv), Biotone IPN(70.06Hv), Endura Posterio (64.48Hv). Results of bonding strength of artificial teeth to composite resins on ES samples(8.73Mpa), IF(4.37Mpa) and IZ(3.84Mpa). Conclusion: 1. The Trubyte Biotone(74.58Hv) was first, followed by Biotone IPN(70.06Hv), and Endura Posterio(64.48Hv) in surface hardness's results of worn sides using hardness test. 2. The ES samples(8.73Mpa) showed significant differences with IF(4.37Mpa) and IZ(3.84Mpa) (p<0.05), but not other samples(p>0.05) in results of bonding strength of artificial teeth to composite resins.

대합되는 재료에 따른 합성수지 인공치의 마모저항성에 관한 비교 연구 (Comparison Study of Wear Resistance Among Several Denture Teeth Opposing Various Restorative Materials)

  • 박영배
    • 대한치과기공학회지
    • /
    • 제31권1호
    • /
    • pp.63-74
    • /
    • 2009
  • Partial or complete prosthesis is needed when teeth are lost due to various kinds of reason. Artificial teeth recover occlusion instead of natural teeth. Artificial teeth are required of esthetics, fragile resistance and abrasive resistance. Artificial tooth is made of acrylic resin or porcelain. Nowadays, acrylic resin artificial teeth are mainly used. Acrylic resin teeth are occluded with natural teeth, gold alloy, Ni-Cr alloy or porcelain etc. Acrylic resin teeth have similar translucency, gloss of natural teeth. And it has good chemical bond with denture base material, but it has low wear resistance. The aim of this study is to compare wear resistance among several denture teeth(Endura, SR-orthosit-PE, Planustar) and between artificial resin denture teeth and opposing 3 restorative materials(gold, Ni-Cr alloy, porcelain). Wear tests were conducted with a rotating wear testing apparatus(pin-on-disk type wear tester) under conditions of rpm 180, 75 minutes and constant loading of 50N. The upper part was the cusp of maxillary first molar and the lower part was a disk type restorative materials. To make similar oral environment, water was supplied continually. The acrylic resin teeth wear was determined by weighing the cusp each 5 minutes during 75 minutes test. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows: 1. Wear rates of acrylic resin teeth opposing to the restorative materials were high in order of Porcelain, Gold, Ni-Cr alloy (p<.05). 2. Wear resistance rate opposing to the Porcelain disk, was shown in order of Endura, SR-orthosit-PE, Planustar. The wear rate of opposing to porcelain disk was above two times more than that of other groups (p<.05). 3. Wear resistance rates opposing to the Gold, Ni-Cr alloy disk, was shown in order of Endura, SR-orthosit-PE, Planustar (p<.05). 4. A degree of the surface hardness is directly proportional to the degree of wear resistance. There are statistically significant differences between each groups (p<.05).

  • PDF

광중합형 프린터로 제작한 임시 의치용 인공치아의 UV형 초음파 세척에 따른 선형측정 평가 (Linear measurement evaluation according to UV-type ultrasonic cleaning of artificial teeth for temporary dentures manufactured using a light-curing type printer produced by a DLP printer)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제46권1호
    • /
    • pp.8-14
    • /
    • 2024
  • Purpose: This study compares the deformation of traditional resin dentures to resin dentures printed with digital light processing (DLP). Methods: Eleven edentulous research models were developed. Ten of them were made with traditional resin dentures. The remaining one was prepared for scanning and 3D (three-dimensional) printing. Ten traditional resin dentures were made, with the remaining artificial teeth created using 3D software and a DLP printer. Traditional resin dentures, 3D printed resin denture artificial teeth, and a denture base with artificial teeth were all cleaned simultaneously in an ultrasonic cleaner for 3 minutes. Three groups were assigned four artificial tooth measurement points, which were then measured with digital calipers. The measured data was analyzed using descriptive statistics. The significance test was conducted using a nonparametric test Kruskal-Wallis test due to the small number of specimens (α=0.05). Results: The traditional resin dentures had the lowest strain rate at -0.04%, while the group that manufactured only artificial teeth had the highest strain rate at -0.09%. However, no statistically significant difference was observed between the 3 groups (p>0.05). Conclusion: During ultraviolet-type ultrasonic cleaning, traditional resin dentures (TD group) and denture base with artificial teeth made of DLP (DD group) demonstrated stable durability, whereas the artificial teeth made of DLP (AD group) with only artificial teeth did not show a good deformation rate.

총의치를 위한 인공치배열과 교합 (The artificial teeth arrangement and occlusion for Complete denture)

  • 송영균
    • 대한치과의사협회지
    • /
    • 제53권6호
    • /
    • pp.411-417
    • /
    • 2015
  • In an edentulous situation, the oral rehabilitation with complete denture is substantially different from treatment of natural teeth. The artificial teeth arrangement and occlusion are important factor for the stability of the denture. Bilateral balanced occlusion is that stability of the denture is attained when bilateral contacts exist throughout all excursion and static states of the denture during function and, artificial teeth are arrangement in neutral zone where the forces between the tongue and cheeks or lips are equal. This is how dentist make a favorable prognosis. Therefore, dentists are have to be a little more involved in the selection and arrangement of artificial teeth.

수종 레진 인공치의 마모도에 관한 연구 (A Study on the Wear of Artificial Resin Teeth)

  • 이정오
    • 대한치과기공학회지
    • /
    • 제20권1호
    • /
    • pp.51-60
    • /
    • 1998
  • The artificial resin teeth used for removable prosthesis have good physical properties, but they have great wear rate. The purpose of this study is to compare the wear characteristics of several artificial resin teeth, such as Myerson teeth(Myerson Crop), Trubite IPN(Dentsply), Endura Posterio(Shofu), SROrthosit(Ivoclar), Trubite Biotone(Dentsply), Five samples of each resin tooth were abraded against natural teeth, type III gold for 150,000 cycles on the wear machine. The results obtained were as follow 1. The wear rate of artificial resin teeth when opposing enamel was the lowest in Myerson teeth($8.60{\mu}m$), followed by Trubite IPN($41.30{\mu}m$), Endure poster($63.00{\mu}m$), SR-Orthosit($68.40{\mu}m$), Trubite Biotone($209.90{\mu}m$) 2. The wear rate of artificial teeth when opposting type III gold specimens was the lowest in Myerson teeth($13.50{\mu}m$) followed by Endura Posterio($14.75{\mu}m$), Trubite IPN($53.40{\mu}m$), SROrthosit($54.20{\mu}m$), Trubite Boitone($341.50{\mu}m$)

  • PDF

4종 아크릴릭 레진 인공치의 물리적 성질에 관한 비교 (COMPARISON OF THE PHYSICAL PROPERTIES OF FOUR KINDS OF ACRYLIC RESIN DENTURE TEETH)

  • 황종우;정재헌;고영무
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.210-230
    • /
    • 1995
  • To compare the wear resistance of four kinds of commercial acrylic resin teeth [SR-Orthosit PosterioresR(Ivoclar Co., Liechtenstein), Endura PosteriorR(Shofu Inc. Japan), trubyte IPN teethR(Dentsply International Inc., York,), Trubyte BiotoneR(dentsply Inermational Inc. Brazil) by means of the toothbrush abrasion method, the artificial resin teeth were embedded in epoxy resin with the occlusal surfaces aligned in one plane for a total of 40 blocks. There after, each lock was mounted in the arm of the toothbrush abrasion machine(K 236, Japan). Wear measurements were made on the three preconditioned states. Those were as follows : no treatment specimens, thermocycled specimens, and thermocycled specimens which were immeresed applied load of 400g during the buring the brushing cycle. At the end of the 30,000-stroke cycle, each specimen was removed, and weighed. The microhardness of four kinds of commercial resin teeth were determined by means of microhardness tester. Microhardness tests were performed on te no treatment specimens, thermocycled specimens, and thermocycled specimens with immersion in the denture cleansing solution. Finally, the comparison of thermal properties were perfomed using differential scanning calorimeter(DSC-1500). The following results were obtained : 1. In the case of no treatment teeth, the wear amount of endura Posterior(EN) was the greatest among the others(p<0.01), and the wear amount of three kinds of artificial resin teeth was increased in the order of Trubyte IPN teeth(IN), Trubyte Biotone(BN), SR-Orthosit Posteriores(SN) but there was no statistic significance(p>0.01). 2. The wear amount of Trubyte IPN teeth(IT) and Trubyte Biotone(BT), was increased due to thermocycling effect, but that of Endura Posteriores(ET) was decreased conversely(p<0.01). 3. Except for the SR-Orthosit Posteriores(STC), the wear amount of three kinds of artificial resing teeth(that is, ETC, ITC, BTC) was increased due to denture cleansing solution$(Cledent^R)$, but there was no statistic significance(p>0.01). But the wear amount of the SR-Orthosit Posteriores(STC) was the greatest among the others(p<0.01). 4. The wear amount of toothbrush was the greatest in case of contact with occlusal surface of SROrthosit Posteriores resin teeth(p<0.01). 5. the microhardness values(KHN) of the SR-Orthosit Posteriores was the highest among the experimental artificial resin teeth(p<0.01). 6. There was no relationship between microhardness valuse(KHN) and wear amount of four kinds of experimental artificial resin teeth(p<0.01). 7. The differential canning calorimetric property of four kinds of artificial resin teeth did not show endothermal or exothermal peak in the range of $100^{\circ}C$

  • PDF

광중합용 DLP 프린터로 제작한 전악 인공치아의 UV-C 초음파 세척에 따른 체적 안정성 평가 (Evaluation of dimension stability according to UV-C ultrasonic cleaning of full arch artificial teeth made with DLP printer for photopolymerization)

  • 김동연;이광영
    • 대한치과기공학회지
    • /
    • 제43권3호
    • /
    • pp.84-92
    • /
    • 2021
  • Purpose: The purpose of this study was to compare the dimension safety evaluation between a general ultrasonic cleaner and an ultrasonic cleaner equipped with UV-C (ultraviolet-C). Methods: An edentulous model was prepared. A denture base and an occlusal rim were fabricated, and scanning was performed. After scanning, a denture base and full arch artificial teeth were designed. The full arch artificial teeth were printed using a three-dimensional printer (n=10). The residual resin was washed with alcohol and then scanned (reference data). The printed specimens were classified and cleaned using a general ultrasonic cleaner (GU group) and an ultrasonic cleaner equipped with UV-C (UC group). After each washing, a rescan was performed (scan data). Reference data and scan data were superimposed using overlapping software. Data were statistically analyzed using the Mann-Whitney test (α=0.05). Results: In the deviation values of full arch artificial teeth, the GU group showed a high deviation of 18.02 ㎛ and the UC group showed a low deviation of 15.02 ㎛. The two groups demonstrated a statistically significant difference (p<0.05). Conclusion: Full arch artificial teeth prepared using photopolymerized resin were deformed according to the temperature of water generated in the ultrasonic cleaner. It is judged that there is no deformation according to the UV-C ultrasonic cleaner.

총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구 (A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE)

  • 권긍록;최대균
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.389-423
    • /
    • 1998
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography (Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as fellows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely(p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge. the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구 (A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE)

  • 권긍록;박남수;최대균
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.539-573
    • /
    • 1996
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography(Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as follows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely (p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge, the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF