• Title/Summary/Keyword: Artificial Sky

Search Result 47, Processing Time 0.033 seconds

Predicted Performance of the Integrated Artificial Lighting System in Relation to Daylight Levels (채광시스템과 인공조명설비의 통합기술 및 성능평가연구)

  • Kim, G.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.3
    • /
    • pp.47-56
    • /
    • 2002
  • The office is an excellent candidate for implementing daylighting techniques because of the relatively high electric lighting power densities and long daytime use pattern. The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an office interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed for both a totally open-plan office interior and a partitioned office. A lighting design and analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting fixture to meet the designed lighting level and calculates unit power density, which translates the demanded amount of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky are evaluated by a computer software, ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year. A 25 % of electric energy for cooling may be saved by dimming and turning off the luminaires in the perimeter zones.

An Analysis of Radiative Observation Environment for Korea Meteorological Administration (KMA) Solar Radiation Stations based on 3-Dimensional Camera and Digital Elevation Model (DEM) (3차원 카메라와 수치표고모델 자료에 따른 기상청 일사관측소의 복사관측환경 분석)

  • Jee, Joon-Bum;Zo, Il-Sung;Lee, Kyu-Tae;Jo, Ji-Young
    • Atmosphere
    • /
    • v.29 no.5
    • /
    • pp.537-550
    • /
    • 2019
  • To analyze the observation environment of solar radiation stations operated by the Korea Meteorological Administration (KMA), we analyzed the skyline, Sky View Factor (SVF), and solar radiation due to the surrounding topography and artificial structures using a Digital Elevation Model (DEM), 3D camera, and solar radiation model. Solar energy shielding of 25 km around the station was analyzed using 10 m resolution DEM data and the skyline elevation and SVF were analyzed by the surrounding environment using the image captured by the 3D camera. The solar radiation model was used to assess the contribution of the environment to solar radiation. Because the skyline elevation retrieved from the DEM is different from the actual environment, it is compared with the results obtained from the 3D camera. From the skyline and SVF calculations, it was observed that some stations were shielded by the surrounding environment at sunrise and sunset. The topographic effect of 3D camera is therefore more than 20 times higher than that of DEM throughout the year for monthly accumulated solar radiation. Due to relatively low solar radiation in winter, the solar radiation shielding is large in winter. Also, for the annual accumulated solar radiation, the difference of the global solar radiation calculated using the 3D camera was 176.70 MJ (solar radiation with 7 days; suppose daily accumulated solar radiation 26 MJ) on an average and a maximum of 439.90 MJ (solar radiation with 17.5 days).

A Study on the Characteristics of Daylight Distributions by Different Sky Conditions and Controlled Roller Shade Heights (천공종류 및 롤러쉐이드의 제어된 높이에 따른 주광분포 특성에 관한 연구)

  • Park, Byoung-Chul;Lim, Ji-Sun;Kim, Yu-Sin;Lee, Jeong-Ho;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.2
    • /
    • pp.18-26
    • /
    • 2009
  • Daylight responsive dimming systems are one of lighting control systems which are to control artificial lightings using available daylight for energy savings. This system is not popular because useful daylight is usually blocked by uncontrolled passive shading systems in buildings. It is necessary to integrate daylight responsive dimming systems and automata! roller shading systems. In this research, mock-up test is performed to analyze the daylight distributions in three different rooms for integrated systems. Roller shades are installed in two rooms. One is fully downed and the other is controlled by sun profile angle. The other room has no shading system as a reference room.

6G in the sky: On-demand intelligence at the edge of 3D networks (Invited paper)

  • Strinati, Emilio Calvanese;Barbarossa, Sergio;Choi, Taesang;Pietrabissa, Antonio;Giuseppi, Alessandro;De Santis, Emanuele;Vidal, Josep;Becvar, Zdenek;Haustein, Thomas;Cassiau, Nicolas;Costanzo, Francesca;Kim, Junhyeong;Kim, Ilgyu
    • ETRI Journal
    • /
    • v.42 no.5
    • /
    • pp.643-657
    • /
    • 2020
  • Sixth generation will exploit satellite, aerial, and terrestrial platforms jointly to improve radio access capability and unlock the support of on-demand edge cloud services in three-dimensional (3D) space, by incorporating mobile edge computing (MEC) functionalities on aerial platforms and low-orbit satellites. This will extend the MEC support to devices and network elements in the sky and forge a space-borne MEC, enabling intelligent, personalized, and distributed on-demand services. End users will experience the impression of being surrounded by a distributed computer, fulfilling their requests with apparently zero latency. In this paper, we consider an architecture that provides communication, computation, and caching (C3) services on demand, anytime, and everywhere in 3D space, integrating conventional ground (terrestrial) base stations and flying (non-terrestrial) nodes. Given the complexity of the overall network, the C3 resources and management of aerial devices need to be jointly orchestrated via artificial intelligence-based algorithms, exploiting virtualized network functions dynamically deployed in a distributed manner across terrestrial and non-terrestrial nodes.

Characterizing light pollution in national parks during peak and off-peak tourist seasons using nighttime satellite images (야간위성영상을이용한국립공원탐방성수기와비수기의빛공해특성분석)

  • Cho, Woo;Sung, Chan-Yong;Ki, Kyong-Seok
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.4
    • /
    • pp.484-489
    • /
    • 2014
  • In this paper, we examined factors that influenced light pollution in Korean national parks during peak and off-peak tourist seasons. Cloud-and moonlight-free nighttime satellite images that were collected during October 2012(for peak season) and January 2013(for off-peak season) by the Day and Night Band (DNB) of the Visible Infrared Imaging Radiometer Suite (VIIRS) sensor were used to estimate the levels of light pollution in 19 national parks (excluding the Bukhansan and Mudeungsan National Parks). Bootstrapping regression analyses were conducted to examine the effects of socioeconomic and policy factors on light pollution in the study national parks for peak and off-peak tourist seasons, separately. The characteristics of light pollution in the national parks varied by season. During the peak tourist season, light pollution in the national parks were affected more by night lights nearby the parks than those within in the parks, while in the off-peak season, light sources in the parks were more important. Scattering of light emitted from hotels and other recreational facilities outside the parks that led to the sky glow effect can be attributed to the greater impact of night lights nearby the parks during the peak season. This result suggests that regulating light pollution nearby the park areas is needed to mitigate light pollution in the national parks, especially in a peak tourist season.

Weather Recognition Based on 3C-CNN

  • Tan, Ling;Xuan, Dawei;Xia, Jingming;Wang, Chao
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.8
    • /
    • pp.3567-3582
    • /
    • 2020
  • Human activities are often affected by weather conditions. Automatic weather recognition is meaningful to traffic alerting, driving assistance, and intelligent traffic. With the boost of deep learning and AI, deep convolutional neural networks (CNN) are utilized to identify weather situations. In this paper, a three-channel convolutional neural network (3C-CNN) model is proposed on the basis of ResNet50.The model extracts global weather features from the whole image through the ResNet50 branch, and extracts the sky and ground features from the top and bottom regions by two CNN5 branches. Then the global features and the local features are merged by the Concat function. Finally, the weather image is classified by Softmax classifier and the identification result is output. In addition, a medium-scale dataset containing 6,185 outdoor weather images named WeatherDataset-6 is established. 3C-CNN is used to train and test both on the Two-class Weather Images and WeatherDataset-6. The experimental results show that 3C-CNN achieves best on both datasets, with the average recognition accuracy up to 94.35% and 95.81% respectively, which is superior to other classic convolutional neural networks such as AlexNet, VGG16, and ResNet50. It is prospected that our method can also work well for images taken at night with further improvement.

A Study on Minimum Detection Limit of Environmental Radioactivity in HPGe Detector (HPGe 검출기에서 환경방사능측정의 검출하한치에 관한 연구)

  • Jang, Eun-Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.1
    • /
    • pp.5-10
    • /
    • 2011
  • Based on basic concept of detection limit, sample measurement time & background measurement time was considered, and MDA values according to background measurement time and sample measurement time in land samples(river soil, surface soil, drinking water, underground water, surface water, pine leaf, mugwort) analysis among environmental samples were compared. Seeing the water sample analysis result, it was shown that most of the samples were not detected, and most of the samples in land specimen analysis showed to be below the detection limit of "Ministry of Education, Science and Technology Announcement Je-2008-28-ho", but $^{137}Cs$ which is one of artificial radioactive nuclide was detected in some samples. It can be traced back to 1950s and 1960s when nuclear tests were carried out in atmosphere and catastrophic Chernobyl atomic power station accident that caused fallouts in the sky, and this is common level of detection that can be observed worldwide. Seeing the result that the $^{134}Cs$(which is a isotope of $^{137}Cs$, and it has relatively short half life) was not detected in all samples, it can be considered it doesn't affect to the operation of atomic power station.

A Study on the Typological Alteration of the Courtyard in Modern Architecture (현대건축에서 나타나는 중정의 유형 변화에 관한 연구)

  • Lee, Jung-Min;Kim, Kook-Sun;Woo, HyunYong
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.4
    • /
    • pp.40-47
    • /
    • 2012
  • Courtyard is evolving from the conventional one element of a building far beyond into independent peremeter of urban architecture, of which function has been darmatically upgraded from embedded traditional air fluiding, nutural lighting system into where full fledged function can be experienced so much as your imagimation reaches taking major social responsibility such as intact offline social networking which links people from neighbors, inter / extra buiding openness which allow people can communicate among othewise between themselves and artificial natural environmental emelents supplier where people resort to relaxation and natural healing. Roles of courtyard has been by far streatched out into nearby natural healing space where people can shake off their unavoidable stresses from the modern life relaxing themselves looking at the sky otherwise observe natural surroundigns such as plants, flowers and waters. Thanks to hereonto mentioned its merits, Courtyard building is widely used and seen as a center of modern urban design in residence, public bilding and urban planned buildings. Courtyard biulding is nowadays boasting their morphological diversity brought out from lots of topological variation, type variants, cross section and inter relationship with the other neighboring spaces. Hence, hereby I have been studied how above mentioned three major peremeters of courtyard has been upgraded in modern architecture comparing the period from 1960 to 1990 and the period starting from 1991.

  • PDF

The Relation between AGN and Star Formation

  • Matsuoka, Kenta;Woo, Jong-Hak;Bae, Hyun-Jin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.48.2-48.2
    • /
    • 2013
  • To understand the connection between active galactic nuclei (AGNs) and star formation, we investigated the relation between AGN bolometric and far-infrared (FIR) luminosities, using type-2 AGNs. By matching type-2 AGNs at z < 0.3 selected from the SDSS based on the emission-line diagnostics, against the AKARI/FIS All-Sky Survey Catalogue and the COSMOS PEP (PACS Evolutionary Probe) Survey Catalogue, we obtained a sample of 729 type-2 AGNs detected in the AKARI survey ($90{\mu}m$) and 17 ones detected in the PEP survey ($100{\mu}m$). For AGN bolometric luminosities, we adopted an estimate based on the [OIII] and [OI] line luminosities. We confirmed that there is a correlation between the AGN bolometric and FIR luminosities with a large scatter, which is consistent with previous studies. However, we claim that this correlation suffers from various artificial effects, e.g., FIR detection limits, survey volumes, and so on. We will discuss the limitations of studying the connection between AGN and star formation using currently available facilities.

  • PDF

Influence of Load Limitation on the Roofspace Planning of Existing Buildings (하중제한이 기존건물의 옥상조경계획에 미치는 영향)

    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.2
    • /
    • pp.166-180
    • /
    • 1998
  • In a city where the greenery always lacks landscaping roofs of existing buildings offers a way to solve the problem. But the most serious problem that poses is the matter of load limit. At present most existing buildings have the loading capacity of 200 kg/$m^2$ or less on their roofs. If the natural soil is used the loading capacity is easily surpassed because it simply is too heavy. To alleviate this problem it is realized to introduce the light weight artificial soil. The specific gravity of light soil is 0.65 whereas the natural soil is 1.8 when wet. It is three times lighter than the natural soil, thus eases the burden to the roof. The next problem to be confronted is the plant species to plant. It is possible to plant trees but they soon outgrow the loading capacity by weighing 8 times heavier in 10 years. Therefore shrubs and perennials are suggested to be planted because they don't weigh much even when they reach the mature height. The last problem is the stress put on roofs by the weight of the users. By some unexpected event the crowd gathered on a weak roof can cause the structural damage or even the collapse of the roof. The avoid the possibility of collapse a plaza or big pocket should not be designed in a roof garden because they hold crowd. By following the suggested means the old roofs of existing buildings can turn into the urban oases in the sky.

  • PDF