• 제목/요약/키워드: Artificial Muscle

검색결과 209건 처리시간 0.028초

A Study on Energy Efficiency in Walking and Stair Climbing for Elderly Wearing Complex Muscle Support System

  • Jang-hoon Shin;Hye-Kang Park;Joonyoung Jung;Dong-Woo Lee;Hyung Cheol Shin;Hwang-Jae Lee;Wan-Hee Lee
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권4호
    • /
    • pp.478-487
    • /
    • 2022
  • Objective: This study was conducted to analyze the effect of wearable complex muscle support system on energy efficiency during walking in elderly. Design: Cross sectional study Methods: Twenty healthy elderly participated in this study. All subjects performed a 6 minuteswalk test(6MWT) and stair climbing test in dual, slack and no suit conditions. In each condition, oxygen consumption(VO2), metabolic equivalents(METs), energy expenditure measures(EEm), physiological cost index(PCI), walking velocity and heartrate were measured. Through repeated measured ANOVA, it was investigated whether there was a statistically significant difference in the measurement results between the three conditions. Results: In over-ground walking, VO2, METs and EEm showed significant differences between no suit and slack conditions(p<0.05). In stair climbing, VO2 showed significant difference between slack and dual conditions(p<0.05). Also, METs and EEm showed significant differences between no suit and slack, and between slack and dual conditions(p<0.05). Conclusions: Wearing the wearable complex muscle support system for elderly does not have much benefit in energy metabolism efficiency in over-ground, but there is a benefit in stair walking.

총의치 안정에 대한 연구 (A Study of Complete Denture Stability)

  • 이재열
    • 대한치과기공학회지
    • /
    • 제6권1호
    • /
    • pp.15-18
    • /
    • 1984
  • A denture that shifts easily in response to latterally applied forces can cause a disruption in the border seal or prevent the denture base from Correctly relating to the supporting tissue. The factors that Contribute to stability include ridge height and conformation, base adaptation, residual ridge relationships, occlusion harmony, and Muscle control. These factors can be condensed into the following categories; 1. The relationship of the denture base to the underlying tissue. 2. The relationship of occlusal harmony. 3. The relationship of the denture surface and border to the surrounding muscle. 4. The location of artificial tooth.

  • PDF

인공 고무 근육을 이용한 로보트 메니퓨레이터의 선형 궤도 추적 제어 (Trajectory tracking controls for a robot manipulator with artificial muscles)

  • 진상호;;;이석규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1992년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 19-21 Oct. 1992
    • /
    • pp.642-646
    • /
    • 1992
  • Trajectory tracking control problems are described for a two-link robot manipulator with artificial rubber muscle actuators. Under the assumption that the so-called independent joint control is applied to the control system, the dynamic model for each link is identified as a linear second-order system with time-lag by the step response. Two control laws such as the feedforward and the computed torque control methods, are experimentally applied for controlling the circular trajectory of an actual robot manipulator.

  • PDF

공압형 인공근육으로 구동되는 상극구동의 다중 동시 사양 제어 (Multiple Simultaneous Specification Control of Antagonistic Actuation by Pneumatic Artificial Muscles)

  • 강봉수
    • 로봇학회논문지
    • /
    • 제6권1호
    • /
    • pp.34-41
    • /
    • 2011
  • This paper presents a frequency-response test performed on an antagonistic actuation system consisting of two Mckibben pneumatic artificial muscles and a pneumatic circuit. A linear model, capable of estimating the dynamic characteristics of the antagonistic system in the operating range of pneumatic artificial muscles, was optimally calculated based on frequency-response results and applied to a multiple simultaneous specification control scheme. Trajectory tracking results showed that the presented multiple simultaneous specification controller, built experimentally by three PD typed sample controllers, satisfied successfully all required control specifications; rising time, maximum overshoot, steady-state error.

공압인공근육을 가진 내부형 연속체로봇의 기구식 (Kinematics of an Intrinsic Continuum Robot with Pneumatic Artificial Muscles)

  • 강봉수
    • 대한기계학회논문집A
    • /
    • 제40권3호
    • /
    • pp.289-296
    • /
    • 2016
  • 본 연구에서는 공압인공근육을 구동부로 가지는 내부형 연속체로봇의 기구학을 제시한다. 연속체로봇 단일마디는 세 개 인공근육의 병렬구조로 구성되며, 각 인공근육은 가해지는 공기압력에 의해서 독립적으로 수축하여 근육의 한쪽이 부착된 기준 마디절에 대해서 근육의 다른쪽이 연결된 원격의 마디절의 공간상 운동이 발생한다. 인공근육의 굽힘형상을 고려하여 원격 마디절 중심에서의 방위와 위치를 예측하는 기구식을 유도하였으며, 단일 마디를 여러 층으로 적층하였을 때 로봇 말단장치에서의 방위와 위치도 변환행렬의 곱으로 제시한다. 그리고 인공근육의 길이/압력 변화에 따른 말단장치에서의 속도를 계산하는 자코비안 행렬을 구동부의 위치배열을 고려하여 유도하였고 실제 실험을 통해서 제시한 기구식의 유효성을 검증하였다.

In vitro and in vivo Application of PLGA Nanofiber for Artificial Blood Vessel

  • Kim, Mi-Jin;Kim, Ji-Heung;Yi, Gi-Jong;Lim, Sang-Hyun;Hong, You-Sun;Chung, Dong-June
    • Macromolecular Research
    • /
    • 제16권4호
    • /
    • pp.345-352
    • /
    • 2008
  • Poly(lactic-co-glycolic acid) (PLGA) tubes (5 mm in diameter) were fabricated using an electro spinning method and used as a scaffold for artificial blood vessels through the hybridization of smooth muscle cells (SMCs) and endothelial cells (ECs) differentiated from canine bone marrow under previously reported conditions. The potential clinical applications of these artificial blood vessels were investigated using a canine model. From the results, the tubular-type PLGA scaffolds for artificial blood vessels showed good mechanical strength, and the dual-layered blood vessels showed acceptable hybridization behavior with ECs and SMCs. The artificial blood vessels were implanted and substituted for an artery in an adult dog over a 3-week period. The hybridized blood vessels showed neointimal formation with good patency. However, the control vessel (unhybridized vessel) was occluded during the early stages of implantation. These results suggest a shortcut for the development of small diameter, tubular-type, nanofiber blood vessels using a biodegradable material (PLGA).

링키지와 결합된 공압 인공근육을 이용한 손 외골격 제작 (Development of Hand Exoskeleton using Pneumatic Artificial Muscle Combined with Linkage)

  • 구인욱;강병현;조규진
    • 한국정밀공학회지
    • /
    • 제30권11호
    • /
    • pp.1217-1224
    • /
    • 2013
  • In this paper, a hand exoskeleton actuated by air muscles(soft hand exoskeleton) is introduced. Some soft hand exoskeletons have already been developed to overcome the defects of hand exoskeletons based on linkage and pneumatic piston system-they are usually bulky and do not have enough degree of freedom(DOF). However, soft hand exoskeletons still have defects. Their motions are not precise as linkage based hand exoskeletons, because their actuator, such as air muscle is made of soft materials. So we developed a new linkage which is not bulky and has redundant DOF. It is combined with air muscle in a specific way so that it acts as a guide when air muscle is actuated. Some experiments were conducted to evaluate the validity and usability of our hand exoskeleton.