• Title/Summary/Keyword: Artifacts

Search Result 1,654, Processing Time 0.031 seconds

A Quest of Design Principles of Cognitive Artifacts through Case Analysis in e-Learning: A Learner-Centered Perspective

  • PARK, Seong Ik;LIM, Wan Chul
    • Educational Technology International
    • /
    • v.10 no.1
    • /
    • pp.1-23
    • /
    • 2009
  • Learners are often posited in a paradoxical situation where they are not fully involved in decision making processes on how to learn, in designing their tools. Cognitive artifacts in e-learning are supposed to effectively support learner-centered e-learning. The purpose of the study is to analyze cases of cognitive artifacts and to inquire those design principles for facilitating the learner-centered e-learning. Four research questions are suggested: First, it will be analyzed the characteristics of learners with respect to design of cognitive artifacts for supporting the learner-centered e-learning. Second, characteristics of four cases to design cognitive artifacts in learner-centered e-learning environment are analyzed. Third, it will be suggested the appropriate design principles of cognitive artifacts to facilitating learner-centered learning in e-learning environment. Four cases of cognitive artifacts design in learner-centered e-learning was identified as follows: Wiki software as cognitive artifacts in computer-supported collaborative learning; 'Play Around Network (PAN)' as cognitive artifact to monitor learning activities in knowledge community; Knowledge Forum System (KFS) as a cognitive artifact in knowledge building; cognitive artifacts in Courses-as-seeds applied meta-design. Five design principles are concluded as follows: Promoting externalization of cognitive artifacts to private media; Helping learners to initiate their learning processes; Encouraging learners to make connections with other learners' knowledge building and their cognitive artifacts; Promoting monitoring of participants' contributions in collaborative knowledge building; Supporting learners to design their cognitive artifacts.

Quantitative Analysis of Factors Affecting Cobalt Alloy Clip Artifacts in Computed Tomography

  • Sim, Sook Young;Choi, Chi Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.5
    • /
    • pp.400-404
    • /
    • 2014
  • Objective : Clip artifacts limit the visualization of intracranial structures in CT scans from patients after aneurysmal clipping with cobalt alloy clips. This study is to analyze the parameters influencing the degree of clip artifacts. Methods : Postoperative CT scans of 60 patients with straight cobalt alloy-clipped aneurysms were analyzed for the maximal diameter of white artifacts and the angle and number of streak artifacts in axial images, and the maximal diameter of artifacts in three-dimensional (3-D) volume-rendered images. The correlation coefficient (CC) was determined between each clip artifact type and the clip blade length and clip orientation to the CT scan (angle a, lateral clip inclination in axial images; angle b, clip gradient to scan plane in lateral scout images). Results : Angle b correlated negatively with white artifacts (r=-0.589, p<0.001) and positively with the angle (r=0.636, p<0.001) and number (r=0.505, p<0.001) of streak artifacts. Artifacts in 3-D images correlated with clip blade length (r=0.454, p=0.004). Multiple linear regression analysis revealed that angle b was the major parameter influencing white artifacts and the angle and number of streak artifacts in axial images (p<0.001), whereas clip blade length was a major factor in 3-D images (p=0.034). Conclusion : Use of a clip orientation perpendicular to the scan gantry angle decreased the amount of white artifacts and allowed better visualization of the clip site.

Determination and classification of intraoral phosphor storage plate artifacts and errors

  • Deniz, Yesim;Kaya, Seher
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.219-228
    • /
    • 2019
  • Purpose: The aim of this study was to determine the reasons and solutions for intraoral phosphor storage plate (PSP) image artifacts and errors, and to develop an appropriate classification of the artifacts. Materials and Methods: This study involved the retrospective examination of 5,000 intraoral images that had been obtained using a phosphor plate system. Image artifacts were examined on the radiographs and classified according to possible causative factors. Results: Artifacts were observed in 1,822 of the 5,000 images. After examination of the images, the errors were divided into 6 groups based on their causes, as follows: images with operator errors, superposition of undesirable structures, ambient light errors, plate artifacts (physical deformations and contamination), scanner artifacts, and software artifacts. The groups were then re-examined and divided into 45 subheadings. Conclusion: Identification of image artifacts can help to improve the quality of the radiographic image and control the radiation dose. Knowledge of the basic physics and technology of PSP systems could aid to reduce the need for repeated radiography.

Conservation of artifacts excavated from Imdang, Kyǒngsan Province-Metals and Lacquerware (경산시 임당유적 출토 유물 보존처리-금속 및 칠기유물을 중심으로)

  • Yu, Jae-Eun;Shin, Ui-Kyoung;Hwang, Jin-Ju;Goh, Dong-Ha
    • 보존과학연구
    • /
    • s.19
    • /
    • pp.109-132
    • /
    • 1998
  • According to excavation of Imdang site, these sites were excavated place to a various of sites from Early lron period to the Koryo Kingdom. Artifacts to be conserved were excavated from A, D and E district. Metal artifacts were excavated from D and E district and lacquer ware artifacts were excavated from Adistrict. Metal artifacts including lacquer ware iron sword, imitative bronze mirror, Osujen and bronze artifact with letter and so on. Bronze artifacts were covered with soil and rust and performed consolidation after passivation treatment with Benzotriazole solution. Also, iron artifacts performed desalting treatment with 0.1M sesquicarbonate solution. After desalinization, adhesive of these artifacts were processed with Araldite(rapid type) after consolidation with20%∼30% NAD-10 solution. Lacquer ware artifacts remained fragments of lacquer to be all corroded and soiled. Therefore these artifacts retained its original form. Fragments of lacquer joined with Caparol 1%∼3% solution and the soil of relics coated with PSNY 3%∼6% solution. There were many kinds of lacquer were. Lacquer ware artifacts presumed to a string instrument that provide important clues for lacquer ware research. As for lacquer fragments inquire, paints grain size were $2∼5\mum$ and conformed to vanished three times.

  • PDF

Artifacts in Digital Radiography (디지털 방사선 시스템에서 발생하는 Artifact)

  • Min, Jung-Whan;Kim, Jung-Min;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.375-381
    • /
    • 2015
  • Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient's health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user didn't have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments.

Content-based Configuration Management System for Software Research and Development Document Artifacts

  • Baek, Dusan;Lee, Byungjeong;Lee, Jung-Won
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.3
    • /
    • pp.1404-1415
    • /
    • 2016
  • Because of the properties of software such as invisibility, complexity, and changeability, software configuration management (SCM) for software artifacts generated during software life-cycle has been used for guarantee of the quality of the software. However, the existing SCM system has only focused on code artifacts and software development document artifacts such as Software Requirements Specification (SRS), Software Design Description (SDD), and Software Test Description (STD). Moreover, software research-oriented project comes out late the code artifacts and the software development document artifacts. Therefore, there is a need for trace and management of software research document artifacts composed of highly abstracted non-functional requirements like 'the purpose of the project', 'the objectives', and 'the progress' before generation of the code artifacts and the software development document artifacts for a long time. Nevertheless, the existing SCM system cannot trace and manage them. In this paper, we propose content-based configuration management system comprised of the relevance link generation phase and content-based testing phase to trace and manage them. The preliminary application results show applicability and feasibility of the proposed system.

A Ring Artifact Correction Method for a Flat-panel Detector Based Micro-CT System (평판 디텍터 기반 마이크로 CT시스템을 위한 Ring Artifact 보정 방법)

  • Kim, Gyu-Won;Lee, Soo-Yeol;Cho, Min-Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.476-481
    • /
    • 2009
  • The most troublesome artifacts in micro computed tomography (micro-CT) are ring artifacts. The ring artifacts are caused by non-uniform sensitivity and defective pixels of the x-ray detector. These ring artifacts seriously degrade the quality of CT images. In flat-panel detector based micro-CT systems, the ring artifacts are hardly removed by conventional correction methods of digital radiography, because very small difference of detector pixel signals may make severe ring artifacts. This paper presents a novel method to remove ring artifacts in flat-panel detector based micro-CT systems. First, the bad lines of a sinogram which are caused by defective pixels of the detector are identified, and then, they are corrected using a cubic spline interpolation technique. Finally, a ring artifacts free image is reconstructed from the corrected projections. We applied the method to various kinds of objects and found that the image qualities were much improved.

Study on Manufacturing Technique by Analysis of Compositions and Microtexture for Korean Bronze Weapons (청동 무기류의 성분조성 및 미세조직을 통한 제작기법 연구)

  • Hwang, Jin-Ju
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.141-154
    • /
    • 2010
  • Many bronze artifacts have been excavated and preserved through conservation treatments in Korea but the analysis on artifacts was regarded as destruction of artifacts from the academic world of archaeology, Therefore, it is not so available to perform research on production techniques and provenances by with qualified analysis. Accordingly, there were only a few study cases about quality properties and production techniques But recently gradual change started to appear from the awareness of the need for the scientific approach to excavated artifacts. While Korean ancestors already had applied the different alloying ratios according to the use and shape of bronze artifacts, the analysis and study have been restrictedly performed. As a result, there was only a few analysis cases on a small minority of artifacts because they are the ancient relics, which made it hard to understand the bronze artifacts more deeply. This study researched into components rate, production techniques and hardness of bronze weapons such as a bronze sword and compared their alloying ratios with those of Chinese old records (周禮考工記, 金之六齊).

  • PDF

A Content Analysis of Traditional Wedding Artifacts (혼례유물에 대한 내용분석)

  • 최배영
    • Journal of Families and Better Life
    • /
    • v.21 no.5
    • /
    • pp.155-170
    • /
    • 2003
  • This paper will provide a basic analysis of traditional wedding artifacts as they appear on museum websites and their value for scientific research. The results of this study are as follows: 1. There were a total of 115 wedding artifacts(72 written documents related to weddings, 43 marital items) on the website of a museum. Most of them were related to the latter half of Cho-sun Dynasty. From these artifacts, we may understand the culture surrounding wedding during the transitional period from the Cho-sun Dynasty to modem time. 2. By analyzing such wedding artifacts, we can supplement existing methods of study such as literature research and case histories. In this way, we may better understand the history and culture of weddings. 3. In order to gain a deeper understanding of the culture of weddings we need to adopt a more interdisciplinary approach of wedding artifacts.

Study on the Detection the Section with the Motion Artifacts of the PPG Signal (PPG 신호의 동잡음 구간 검출에 관한 연구)

  • Lee, Hanwook;Lee, Gunki
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • The biomedical information (heart rate, HRV, $SpO_2$ etc) from the Photoplethysmography (PPG) signal section can be estimated without the motion artifacts if the PPG signal section in the motion artifacts is detected accurately. But the PPG signal is easily exposed to the motion artifacts by the decrease of the medical instrument size and applying as portable or wearable. Besides, it is difficult to completely eliminate the motion artifacts from the PPG signal without distortion and ensure reliability as well. In this paper, the method was suggested to determine the motion artifacts or not on the PPG signal of the section divided into intervals of constant length. By comparing the spectrum of each section, it can be determined whether the motion artifacts are or not after obtaining the spectrum of each section by the Goertzel algorithm. Moreover, an amount of computation while maintaining a high detection rate can be reduced by using the Goertzel algorithm.