• Title/Summary/Keyword: Arrhenius acceleration model

Search Result 20, Processing Time 0.025 seconds

Investigation of the Acceleration Coefficient in Acceleration Models (가속모델의 가속계수 조사)

  • Hyunjong Park;Sungjun Kim;Beomsik Park;Somi Park;Siil Sung
    • Journal of Korean Society for Quality Management
    • /
    • v.52 no.1
    • /
    • pp.135-148
    • /
    • 2024
  • Purpose: This study is to investigate the literature on accelerated tests based on the acceleration model and to provide a compilation of results on the parameters applied in the acceleration model and the test conditions. Methods: This research is conducts a literature review on accelerated tests using the acceleration model, with a focus on test targets, test conditions, and parameter values. The study is organizing the results of this literature review to facilitate their application in the design of reliability tests. Results: A literature review investigated a variety of test targets, test conditions, and parameter values. Conclusion: The results of the literature research conducted revealed various acceleration model parameter. Such literature research on accelerated tests can establish the foundation for reliability test design and contribute to future product development and quality improvement

An Accelerated Life Test of LED Lights for Aviation Taxiway (항공유도로등화용 LED 광원의 가속수명시험)

  • Min, Kyong-Chan;Yun, Yang-Gi;Kim, Myung-Soo
    • Journal of Applied Reliability
    • /
    • v.11 no.2
    • /
    • pp.127-140
    • /
    • 2011
  • This paper presents an accelerated life test of aviation taxiway lights installed in the airport to help safe navigation of airplanes at night or in bad weather. Recently halogen lamps of taxiway lights are replaced by LED ones and their reliability needs yet to be verified. Thus, effective test conditions are designed reflecting the failure modes and mechanisms from the previous studies on LED, which include the accelerated degradation process. The test is performed under the temperature $70^{\circ}C$ and $90^{\circ}C$ for two types of LED lights, taxiway center line lights(TCLL) and taxiway edge lights (TEDL). The failure time data were analyzed using lognormal distribution and Arrhenius model to find the life-stress relationship, acceleration factor and life characteristics under the normal condition temperature $30^{\circ}C$.

Service Life Prediction of Components or Materials Based on Accelerated Degradation Tests (가속열화시험에 의한 부품·소재 사용수명 예측에 관한 연구)

  • Kwon, Young Il
    • Journal of Applied Reliability
    • /
    • v.17 no.2
    • /
    • pp.103-111
    • /
    • 2017
  • Purpose: Accelerated degradation tests can speed time to market and reduce the test time and costs associated with long term reliability tests to verify the required service life of a product or material. This paper proposes a service life prediction method for components or materials using an accelerated degradation tests based on the relationships between temperature and the rate of failure-causing chemical reaction. Methods: The relationship between performance degradation and the rate of a failure-causing chemical reaction is assumed and least square estimation is used to estimate model parameters from the degradation model. Results: Methods of obtaining acceleration factors and predicting service life using the degradation model are presented and a numerical example is provided. Conclusion: Service life prediction of a component or material is possible at an early stage of the degradation test by using the proposed method.

The Study on the High Acceleration Life Test Method for the Automotive Electric and Electronic Parts (자동차 전장부품의 초 가속 실뇌성 수명시험 방법에 관한 연구)

  • Lee, Jong-Beom;Cho, Jai-Rip
    • Journal of Korean Society for Quality Management
    • /
    • v.28 no.4
    • /
    • pp.16-28
    • /
    • 2000
  • Recently days, High Accelerated Life Test of electrical and electronic parts is increasing its importance. This study set the hypothesis to develop the method that was analysis and application of HALT for the automotive electrical and electronic parts, it used Arrhenius's Model and Eyring's Model, and ESS theory. Validity of application is proved by other test data. Especially, this study emphasis on utility of acceleration to temperature, humidity, voltage, mechanical stress and other stress. In this study set the pattem of practical application. Therefore, this study emphasis on the application of the HALT and the use of other parameter by acceleration reliability test data. The result of this study is as follows. 1) There is relationship between molar weight and material constant. 2) Characteristic of material is operating acceleration factor as well as parts failure factors. Of course, according to the characteristic of material, activation energy is often more important than molar weight. But it will be defined by more testing and improvements in practical application.

  • PDF

A Study on OLED's lifetime at high temperature (OLED소자의 고온에서의 가속 수명에 관한 연구)

  • Choi, Young-Tae;Cho, Jai-Rip
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2008.04a
    • /
    • pp.273-282
    • /
    • 2008
  • To application Arrhenius model for OLED's lifetime, it's needed in high temperature test. Because OLED's character is changed in high temperature, it's important to find limit temperature. We found out $40^{\circ}C$ is proper temperature by result of tests. But that is not enough acceleration to apply in practical affairs. We find new stress to get a bigger accelerated constant.

  • PDF

A Study of Life about Naturally Aged Nitrocellulose by Storage (자연 노화된 니트로셀룰로오스의 수명에 관한 연구)

  • Kim, Dong-seong;Jin, Hong-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.595-601
    • /
    • 2020
  • During the safety inspection of nitrocellulose-made explosive containers stored for more than 10 years, cracks were found in the containers. Therefore, a failure cause analysis test was performed. First, the cause of failure through the failure tree analysis was conducted to select the factors that influenced failure. The changes in the properties of the container caused by the acceleration of the reaction were found to be the cause of the failure by confirming the influence on the environment and internal/external factors that may occur during storage. To confirm this, environmental tests, such as thermal shock test and vacuum thermal stability test, were performed using a naturally aged container to analyze the cause of failure, and an accelerated aging test was performed to reproduce the failure. Through this, the chemical reaction was accelerated by heat and charge, as in the result of the fault tree analysis, and it was confirmed that the physical properties of the container were changed. In addition, the service life of the container was estimated using the Arrhenius model for the storage life due to thermal aging.

An Example of Modification of Design Validation Test Specification to Reduce the Environmental Durability Test Time of Electronic Control Unit for Motor-Driven Power Steering system (전동식 조향 장치용 ECU 의 환경 내구 시험 시간 단축을 위한 설계 검증 시험 사양 변경 사례)

  • Kim, Tae-Hun;Kang, Dong-Young;Chung, In-Seung
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1309-1313
    • /
    • 2008
  • This paper suggests an example of modification of the durability test specifications of electronic control unit for an automotive system in phase of design validation. The basic concept to redefine the specifications of durability test is based on the Arrhenius relationship for accelerated temperature test and the modified Coffin-Manson model for temperature cycle test. The ambient temperature of the powered-event durability test is increased to reduce the required test time of the current specification. Furthermore, the holding time between the events to cool down the temperature of the components is shortened and the resultant temperature rise affects the durability of the components. Thus, the acceleration factor due to the increased temperature range of temperature cycle is also estimated by the modified Coffin-Manson model.

  • PDF

An Accelerated Degradation Test of Electric Double-Layer Capacitors (전기이중층커패시터의 가속열화시험)

  • Jung, Jae-Han;Kim, Myung-Soo
    • Journal of Applied Reliability
    • /
    • v.12 no.2
    • /
    • pp.67-78
    • /
    • 2012
  • An electric double-layer capacitor(EDLC) is an electrochemical capacitor with relatively high energy density, typically hundreds of times greater than conventional electrolytic capacitors. EDLCs are widely used for energy storage rather than as general-purpose circuit components. They have a variety of commercial applications, notably in energy smoothing and momentary-load devices, and energy-storage and kinetic energy recovery system devices used in vehicles, etc. This paper presents an accelerated degradation test of an EDLC with rated voltage 2.7V, capacitance 100F, and usage temperature $-40^{\circ}C{\sim}65^{\circ}C$. The EDLCs are tested at $50^{\circ}C$, $60^{\circ}C$, and $70^{\circ}C$, respectively for 1,750hours, and their capacitances are measured at predetermined times by constant current discharge method. The failure times are predicted from their capacitance deterioration patterns, where the failure is defined as 30% capacitance decrease from the initial one. It is assumed that the lifetime distribution of EDLC follows Weibull and Arrhenius life-stress relationship holds. The life-stress relationship, acceleration factor, and $B_{10}$ life at design condition are estimated by analyzing the accelerated life test data.

Aging Effect of Bio-inspired Artificial Basilar Membrane with Piezoelectric PVDF Thin Film

  • Kim, Wan Doo;Park, Su A;Kim, Sang Won;Kwak, Jun-Hyuk;Jung, Young Do;Hur, Shin
    • Elastomers and Composites
    • /
    • v.50 no.4
    • /
    • pp.292-296
    • /
    • 2015
  • Biomimetic artificial basilar membrane being a core part of artificial cochlear requires performance evaluation through aging test. To evaluate the aging properties of PVDF piezoelectric membrane used for artificial basilar membrane, its mechanical properties such as tensile strength and elastic modulus and piezoelectric property such as piezoelectric constant were measured. The aging test conditions and acceleration constants were calculated based on Arrhenius model. The changes in tensile strengths and elastic moduli measured were less than 10~20% after aging test equivalent for 10 years. The piezoelectric constants were decreased drastically to 80% of its initial value in the early stage of the aging test and expected to decrease slowly down to 65% over 10 years. The experimental results show the reliability of totally implantable novel artificial cochlear and will contribute its commercialization.

Lifetime estimation for current sensor by accelerated life test (가속수명시험을 통한 전류센서의 수명 예측)

  • Kim, Je-Min;Choi, Sung-Soon;Ma, Byung-Jin;Lee, Kwan-Hun;Song, Byeong-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.257-258
    • /
    • 2008
  • Hall-type current sensors have been widely used in many fields such as elevator and train system. To estimate lifetime of hall-type current sensors, an accelerated life test with real-time monitoring system simultaneously was designed and performed in high temperature environment with three different temperatures. From the experimental results, activation energy was about 0.9 eV, and acceleration factor was about 450 based on Arrhenius model. As a results, $B_{10}$ lifetime of hall-type current sensor is estimated to be 65,460 hours.

  • PDF