Development of Diode Based High Energy X-ray Spatial Dose Distribution Measuring Device

  • Lee, Jeonghee;Kim, Ikhyun;Park, Jong-Won;Lim, Yong-Kon;Moon, Myungkook;Lee, Sangheon;Lim, Chang Hwy
    • Journal of Radiation Protection and Research
    • /
    • 제43권3호
    • /
    • pp.97-106
    • /
    • 2018
  • Background: A cargo container scanner using a high-energy X-ray generates a fan beam X-ray to acquire a transmitted image. Because the generated X-rays by LINAC may affect the image quality and radiation protection of the system, it is necessary to acquire accurate information about the generated X-ray beam distribution. In this paper, a diode-based multi-channel spatial dose measuring device for measuring the X-ray dose distribution developed for measuring the high energy X-ray beam distribution of the container scanner is described. Materials and Methods: The developed high-energy X-ray spatial dose distribution measuring device can measure the spatial distribution of X-rays using 128 diode-based X-ray sensors. And precise measurement of the beam distribution is possible through automatic positioning in the vertical and horizontal directions. The response characteristics of the measurement system were evaluated by comparing the signal gain difference of each pixel, response linearity according to X-ray incident dose change, evaluation of resolution, and measurement of two-dimensional spatial beam distribution. Results and Discussion: As a result, it was found that the difference between the maximum value and the minimum value of the response signal according to the incident position showed a difference of about 10%, and the response signal was linearly increased. And it has been confirmed that high-resolution and two-dimensional measurements are possible. Conclusion: The developed X-ray spatial dose measuring device was evaluated as suitable for dose measurement of high energy X-ray through confirmation of linearity of response signal, spatial uniformity, high resolution measuring ability and ability to measure spatial dose. We will perform precise measurement of the X-ray beamline in the container scanning system using the X-ray spatial dose distribution measuring device developed through this research.

스퍼터링 방법으로 성장시킨 나노구조의 Ga 농도 변화에 따른 형상 변화

  • 김영이;우창호;조형균
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2009년도 추계학술발표대회
    • /
    • pp.23.1-23.1
    • /
    • 2009
  • ZnO is of great interest for various technological applications ranging from optoelectronics to chemical sensors because of its superior emission, electronic, and chemical properties. In addition, vertically well-aligned ZnO nanorods on large areas with good optical and structural properties are of special interest for the fabrication of electronic and optical nanodevices. To date, several approaches have been proposed for the growth of one-dimensional (1D) ZnO nanostructunres. Several groups have been reported the MOCVD growth of ZnO nanorods with no metal catalysts at $400^{\circ}C$, and fabricated a well-aligned ZnO nanorod array on a PLD prepared ZnO film by using a catalyst-free method. It has been suggested that the synthesis of ZnO nanowires using a template-less/surfactant-free aqueous method. However, despite being a well-established and cost-effective method of thin film deposition, the use of magnetrons puttering to grow ZnO nanorods has not been reported yet. Additionally,magnetron sputtering has the dvantage of producing highly oriented ZnO film sat a relatively low process temperature. Currently, more effort has been concentrated on the synthesis of 1D ZnO nanostructures doped with various metal elements (Al, In, Ga, etc.) to obtain nanostructures with high quality,improved emission properties, and high conductance in functional oxide semiconductors. Among these dopants, Ga-doped ZnO has demonstrated substantial advantages over Al-doped ZnO, including greater resistant to oxidation. Since the covalent bond length of Ga-O ($1.92\;{\AA}$) is nearly equal to that of Zn-O ($1.97\;{\AA}$), high electron mobility and low electrical resistivity are also expected in the Ga-doped ZnO. In this article, we report the successful growth of Ga-doped ZnO nanorods on c-Sapphire substrate without metal catalysts by magnetrons puttering and our investigations of their structural, optical, and field emission properties.

  • PDF

고종횡비를 갖는 용액기반 원통형 마이크로렌즈 제조 (Fabrication of Solution-Based Cylindrical Microlens with High Aspect Ratio)

  • 전경준;이진영;박종운
    • 반도체디스플레이기술학회지
    • /
    • 제20권1호
    • /
    • pp.70-76
    • /
    • 2021
  • A cylindrical microlens (CML) has been widely used as an optical element for organic light-emitting diodes (OLEDs), light diffusers, image sensors, 3D imaging, etc. To fabricate high-performance optoelectronic devices, the CML with high aspect ratio is demanded. In this work, we report on facile solution-based processes (i.e., slot-die and needle coatings) to fabricate the CML using poly(methyl methacrylate) (PMMA). It is found that compared with needle coating, slot-die coating provides the CML with lower aspect ratio due to the wide spread of solution along the hydrophilic head lip. Although needle coating provides the CML with high aspect ratio, it requires a high precision needle array module. To demonstrate that the aspect ratio of CML can be enhanced using slot-die coating, we have varied the molecular weight of PMMA. We can achieve the CML with higher aspect ratio using PMMA with lower molecular weight at a fixed viscosity because of the higher concentration of PMMA solute in the solution. We have also shown that the aspect ratio of CML can be further boosted by coating it repeatedly. With this scheme, we have fabricated the CML with the width of 252 ㎛ and the thickness of 5.95 ㎛ (aspect ratio=0.024). To visualize its light diffusion property, we have irradiated a laser beam to the CML and observed that the laser beam spreads widely in the vertical direction of the CML.

벡터 하이드로폰을 위한 두께 전단형 진동자의 빔 패턴 해석 (Analysis of the beam pattern of a thickness shear mode vibrator for vector hydrophones)

  • 김정석;김회용;노용래
    • 한국음향학회지
    • /
    • 제36권3호
    • /
    • pp.158-164
    • /
    • 2017
  • 수중에서 은밀하게 움직이는 표적을 조기에 탐지하기 위한 선배열센서에 적용되는 통상의 하이드로폰은 표적신호의 크기만 측정할 뿐, 외부에서 들어오는 음향신호의 방향은 파악할 수 없는 한계가 있다. 이에 본 연구에서는 표적으로부터의 음향신호의 크기와 방향을 동시에 탐지할 수 있는 관성형 벡터 하이드로폰의 기본 구성품으로 두께 전단형 진동자를 제안하였다. 외력에 대한 진동자의 출력 전압을 해석할 수 있는 수식을 유도하였으며, PMN-PT 단결정 진동자에 대한 유한요소해석을 통해 수식의 타당성을 검증하였다. 본 연구에서 얻어진 해석 결과는 향후 두께 전단형 진동자로 구성된 관성형 벡터 하이드로폰 설계에 활용될 것이다.

균일 유동장내 튜브 배열의 유동관련 진동에 관한 연구 (I) (A Study on Flow-Induces Vibration of Tube Array in Uniform Crossflow(I))

  • 이기백;김봉환;양장식;김문경;장석상
    • 대한기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.924-932
    • /
    • 1992
  • 본 연구에서는 풍동내에 놓여진 탄성지지 실린더의 와유출 특성과 진동 응답 을 동시에 측정하고 분석하여 유입속도 변화에 따른 이들의 상호관계를 확인하고 아울 러 실린더가 통과하는 풍동측정부에 있는 틈새 간격변화가 와유출과 실린더의 진동특 성에 미치는 영향에 대해 조사하였다.

Photoluminescent Graphene Oxide Microarray for Multiplex Heavy Metal Ion Analysis

  • Liu, Fei;Ha, Hyun Dong;Han, Dong Ju;Park, Min Su;Seo, Tae Seok
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제45회 하계 정기학술대회 초록집
    • /
    • pp.281.2-281.2
    • /
    • 2013
  • Since heavy metal ions included in water or food resources have critical effects on human health, highly sensitive, rapid and selective analysis for heavy metal detection has been extensively explored by means of electrochemical, optical and colorimetric methods. For example, quantum dots (QDs), such as semiconductor QDs, have received enormous attention due to extraordinary optical properties including high fluorescence intensity and its narrow emission peaks, and have been utilized for heavy metal ion detection. However, the semiconductor QDs have a drawback of serious toxicity derived from cadmium, lead and other lethal elements, thereby limiting its application in the environmental screening system. On the other hand, Graphene oxide (GO) has proven its superlative properties of biocompatibility, unique photoluminescence (PL), good quenching efficiency and facile surface modification. Recently, the size of GO was controlled to a few nanometers, enhancing its optical properties to be applied for biological or chemical sensors. Interestingly, the presence of various oxygenous functional groups of GO contributes to opening the band gap of graphene, resulting in a unique PL emission pattern, and the control of the sp2 domain in the sp3 matrix of GO can tune the PL intensity as well as the PL emission wavelength. Herein, we reported a photoluminescent GO array on which heavy metal ion-specific DNA aptamers were immobilized, and sensitive and multiplex heavy metal ion detection was performed utilizing fluorescence resonance energy transfer (FRET) between the photoluminescent monolayered GO and the captured metal ion.

  • PDF

A phase synthesis time reversal impact imaging method for on-line composite structure monitoring

  • Qiu, Lei;Yuan, Shenfang
    • Smart Structures and Systems
    • /
    • 제8권3호
    • /
    • pp.303-320
    • /
    • 2011
  • Comparing to active damage monitoring, impact localization on composite by using time reversal focusing method has several difficulties. First, the transfer function of the actuator-sensor path is difficult to be obtained because of the limitation that no impact experiment is permitted to perform on the real structure and the difficulty to model it because the performance of real aircraft composite is much more complicated comparing to metal structure. Second, the position of impact is unknown and can not be controlled as the excitation signal used in the active monitoring. This makes it not applicable to compare the difference between the excitation and the focused signal. Another difficulty is that impact signal is frequency broadband, giving rise to the difficulty to process virtual synthesis because of the highly dispersion nature of frequency broadband Lamb wave in plate-like structure. Aiming at developing a practical method for on-line localization of impact on aircraft composite structure which can take advantage of time reversal focusing and does not rely on the transfer function, a PZT sensor array based phase synthesis time reversal impact imaging method is proposed. The complex Shannon wavelet transform is presented to extract the frequency narrow-band signals from the impact responded signals of PZT sensors. A phase synthesis process of the frequency narrow-band signals is implemented to search the time reversal focusing position on the structure which represents the impact position. Evaluation experiments on a carbon fiber composite structure show that the proposed method realizes the impact imaging and localization with an error less than 1.5 cm. Discussion of the influence of velocity errors and measurement noise is also given in detail.

임베디드 시스템 기반 오버헤드 빈 내부 상황 실시간 식별 시스템 개발 (Development of the Embedded System-based Real-time Internal Status Identification System for Overhead Bin)

  • 김재은;임혜정;조성욱
    • 항공우주시스템공학회지
    • /
    • 제17권2호
    • /
    • pp.111-119
    • /
    • 2023
  • 본 논문에서 제안하는 스토리지 박스의 내부 상황에 대한 실시간 식별 시스템은 오버헤드 빈의 내부 보관 상태, 무게 정보 및 무게 중심 계산 값을 시각화하는 시스템이다. 제안된 시스템은 로드 셀과 스위치 어레이를 사용하여 각 측정값을 동기화하고 시각적 센서를 통해 의미 있고 필요한 정보를 제공한다. 이 시스템은 C 언어 기반 임베디드 시스템으로 구축되며 1) 내부 가용공간 파악, 2) 무게중심 계산, 3) 실시간 시각 정보 제공이 주요 기능이다. 이러한 기능을 통해 스마트 오버헤드 빈을 개발하고, 향후 화물 적재 자동화 시스템 개발에 기여할 수 있는 실시간 화물 적재 모니터링 기술을 개발하였다.

Wireless operational modal analysis of a multi-span prestressed concrete bridge for structural identification

  • Whelan, Matthew J.;Gangone, Michael V.;Janoyan, Kerop D.;Hoult, Neil A.;Middleton, Campbell R.;Soga, Kenichi
    • Smart Structures and Systems
    • /
    • 제6권5_6호
    • /
    • pp.579-593
    • /
    • 2010
  • Low-power radio frequency (RF) chip transceiver technology and the associated structural health monitoring platforms have matured recently to enable high-rate, lossless transmission of measurement data across large-scale sensor networks. The intrinsic value of these advanced capabilities is the allowance for high-quality, rapid operational modal analysis of in-service structures using distributed accelerometers to experimentally characterize the dynamic response. From the analysis afforded through these dynamic data sets, structural identification techniques can then be utilized to develop a well calibrated finite element (FE) model of the structure for baseline development, extended analytical structural evaluation, and load response assessment. This paper presents a case study in which operational modal analysis is performed on a three-span prestressed reinforced concrete bridge using a wireless sensor network. The low-power wireless platform deployed supported a high-rate, lossless transmission protocol enabling real-time remote acquisition of the vibration response as recorded by twenty-nine accelerometers at a 256 Sps sampling rate. Several instrumentation layouts were utilized to assess the global multi-span response using a stationary sensor array as well as the spatially refined response of a single span using roving sensors and reference-based techniques. Subsequent structural identification using FE modeling and iterative updating through comparison with the experimental analysis is then documented to demonstrate the inherent value in dynamic response measurement across structural systems using high-rate wireless sensor networks.

전력계통 구조물의 상태진단용 자가발전 무선 센서 노드 개발 및 평가 (Development and Evaluation of Self-powered Energy Harvester in Wireless Sensor Node for Diagnosis of Electric Power System)

  • 김창일;정영훈;윤지선;홍연우;장용호;최범진;박신서;손천명;서덕기;백종후
    • 센서학회지
    • /
    • 제25권5호
    • /
    • pp.371-376
    • /
    • 2016
  • A self-powered piezoelectric energy harvester was developed for the application in wireless sensor node. The energy harvester was evaluated with power generation characteristics for the wireless sensor node for structural diagnosis of the electric power system. The self-powered wireless sensor node was set to measure temperature, vibration frequency of the electric power system. A piezoelectric harvester composed of 7 uni-morph cantilevers (functionalized as 6 generators and 1 vibration sensor) was connected to be an array and revealed to produce significantly high output power of approximately 10 mW at 120 Hz under 3.4 g((1 g = $9.8m/sec^2$). The wireless sensor node could work as the electric power generated by the developed piezoelectric harvester.