• Title/Summary/Keyword: Array electrode

Search Result 223, Processing Time 0.026 seconds

Recording and Analysis of Peripheral Nerve Activity Using Multi-Electrode Array (다채널 신경전극 어레이를 이용한 말초 신경신호의 측정 및 분석)

  • Chu, Jun-Uk
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.279-285
    • /
    • 2016
  • Reliable recording and analysis of peripheral nerve activity is important to recognize the user's intention for controlling a neuro-prosthetic hand. In this paper, we present a peripheral nerve recording system that consisted of an intrafascicular multi-electrode array, an electrode insertion device, and a multi-channel neural amplifier. The 16 channel multi-electrode array was stably implanted into the sciatic nerve of the rat under anesthesia using the electrode insertion device. During passive movements and mechanical stimuli, muscle and cutaneous afferent signals were recorded with the multi-channel neural amplifier. Furthermore, we propose a spike sorting method to isolate individual neuronal unit. The muscle proprioceptive units were classified as muscle spindle afferents or Golgi tendon organ afferents, and the skin exteroceptive units were categorized as slow adapting afferents or fast adapting afferents. Experimental results showed that the proposed method could be applicable to record and analyze peripheral nerve activity in neuro-prosthetic systems.

Electrical characteristics and pulse memory operation of 3-electrode DC-PDP (3전극 직류형 PDP의 전기적 특성과 펄스 메모리 구동)

  • 명대진;손일헌
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.7
    • /
    • pp.32-39
    • /
    • 1998
  • This paper presents the experimental results on the 3-electrode DC-PDP which has a common electrode to improve the PDP life cycle. The measured DC characteristic proves the effectiveness of common electrode absorbing about half of discharge currents. The waveforms for pulse memory operation of3-electrode PDP without crosstalk could also be determined from the I-V characteristics. The pulse memory drives of 8*8 cell array show the frequency response fo memory margin and the luminance efficiency of 3-electrode PDP are quite different from genrally known characteristics of 2-electrode DC-PDP.

  • PDF

Enhanced Sensitivity of PEDOT Microtubule Electrode to Hydrogen Peroxide by Treatment with Gold (금 처리를 통한 PEDOT 마이크로튜브 전극의 과산화수소 검출 특성 향상)

  • Park, Jongseo;Son, Yongkeun
    • Polymer(Korea)
    • /
    • v.38 no.6
    • /
    • pp.809-814
    • /
    • 2014
  • An array structure of conducting polymer microtubule was fabricated for an amperometric biosensor. 3,4-Ethylenedioxythiophene (EDOT) was electropolymerized in the microporous template membrane with poly(3,4-ethylenedioxythiophene)/poly(4-styrenesulfonic acid) (PEDOT/PSS) composite as a binder. The array structure can provide enhanced current collecting capability due to large active surface area compared to the macroscopic area of the electrode itself. For a biosensor application, the array electrode was tested for $H_2O_2$ detection and showed very sluggish electrochemical response to $H_2O_2$. To enhance the detection efficiency to the oxidation of $H_2O_2$, gold was treated on the electrode by two different approaches: sputtering and electrochemical deposition. Gold treatment with either method greatly enhanced the sensitivity of the electrode to $H_2O_2$. So, conducting polymer microtubule array with gold treatment was expected to be a sensitive amperometric biosensor system based on the detection of $H_2O_2$.

Simulations of Effects of Common Electrode Voltage Distributions on Pixel Characteristics in TFT -LCD (TFT-LCD 공통 전극 전압 분포에 따른 화소 특성 시뮬레이션)

  • Kim, Tae-Hyung;Park, Jae-Woo;Kim, Jin-Hong;Choi, Jong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.165-168
    • /
    • 2000
  • An active-matrix LCD using thin film transistors (TFT) has been widely recognized as having potential for high-quality color fiat-panel displays. Pixel-Design Array Simulation Tool (PDAST) was used to profoundly understand the gate signal distortion and pixel charging capability, which are the most critical limiting factors for high-quality TFT-LCDs. In addition, PDAST can estimate voltage distributions in common electrode which can affect pixel voltage and feed-through voltage. Since PDAST can simulate the gate, data and the pixel voltages of a certain pixel on TFT array at any time and at any location on an array, the effect of common electrode voltage can be effectively analyzed. The information obtained from this study could be utilized to design the larger area and finer image quality panel.

  • PDF

Surface Treatment of Multi Electrode Array for Enhancement of Neuronal Signal (신경 신호 증대를 위한 Multi Electrode Array 전극의 표면 처리)

  • Lee, Byoung-Kab;Hwang, Young-Ha;Pak, Jung-Ho;Lee, Kyung-Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.481-484
    • /
    • 2004
  • 다중 채널 전극 위에 세포를 성장시켜 전극면을 통해 검출되는 신경 신호의 손실을 줄이고 주파수의 변형을 줄이기 위해서 전극과 전해질의 사이의 impedance를 줄이는 것이 바람직하다. 전하 이동을 증대시키기 위해서는 낮은 impedance가 요구되며 이를 위한 전극의 개선 방안으로 전극면이 증착될 기판의 표면을 거칠게 하여 결과적으로 전극면의 표면적을 넓히는 방법을 모색하였다. 기판으로 사용되는 glass(Pyrex#7740)의 구성 물질 중에서 4%를 차지하는 $N^+$ 이온을 황산 용액으로 표면 처리하여 제거함으로써 매끈한 표면을 거칠게 하여 표면적을 넓힐 수 있다. 기판으로 사용되는 glass (pyrex#7740) $1cm{\times}1cm{\times}0.05cm$를 50%, 95% 농도의 황산 용액 내에서 각각 30분, 60분 동안 상온에서 표면처리를 진행하였다. AFM을 이용하여 표면을 관찰한 결과 황산 용액 95%에서 30분간 표면 처리를 진행한 시편에서 최대 $4000{\AA}$정도의 조도를 얻었다. 이후 동일 시편에 대해 전극으로 사용될 Ti/Au를 각각 $500{\AA}/2500{\AA}$ 증착 후 사진식각 공정으로 MEA(Multi-channel electrode array)를 제작하여 impedance를 측정한 결과, 표면 처리 후 impedance가 70% 개선되었음을 측정하였다.

  • PDF

Development of High-Quality Poly(3,4-ethylenedioxythiophene) Electrode Pattern Array Using SC1 Cleaning Process (SC1 세척공정을 이용한 고품질 Poly(3,4-ethylenedioxythiophene) 전극 패턴 어레이의 개발)

  • Choi, Sangil;Kim, Wondae;Kim, Sungsoo
    • Journal of Integrative Natural Science
    • /
    • v.4 no.4
    • /
    • pp.311-314
    • /
    • 2011
  • Application of self-assembled monolayers (SAMs) to the fabrication of organic thin film transistor has been recently reported very often since it can help to provide ohmic contact between films as well as to form simple and effective electrode pattern. Accordingly, quality of these ultra-thin films is becoming more imperative. In this study, in order to manufacture a high quality SAM pattern, a hydrophobic alkylsilane monolayer and a hydrophilic aminosilane monolayer were selectively coated on $SiO_2$ surface through the consecutive procedures of a micro-contact printing (${\mu}CP$) and dip-coating methods under extremely dry condition. On a SAM pattern cleaned with SC1 solution immediately after ${\mu}CP$, poly(3,4-ethylenedioxythiophene) (PEDOT) source and drain electrode array were very selectively and nicely vapour phase polymerized. On the other side, on a SC1-untreated SAM pattern, PEDOT array was very poorly polymerized. It strongly suggests that the SC1 cleaning process effectively removes unwanted contaminants on SAM pattern, thereby resulting in very selective growth of PEDOT electrode pattern.

Array Sensing Using Electromagnetic Method for Detection of Smelting in Submerged Arc Furnaces

  • Liu, WeiLing;Han, XiaoHong;Yang, LingZhen;Chang, XiaoMing
    • Journal of Magnetics
    • /
    • v.21 no.3
    • /
    • pp.322-329
    • /
    • 2016
  • In this paper, we propose an array sensing detection method for smelting of submerged arc furnaces (SAF) based on electromagnetic radiation. AC magnetic field generated by electrode currents and molten currents in the furnace is reflected outside of the furnace. According to the spatial distribution of electromagnetic field a radiation model of SAF is built. We design a 3D magnetic field sensing array system in order to collect the magnetic field information. Through the collected information, the current distribution characteristics of SAF are described and the key parameters of smelting are obtained. Theoretical simulation and field test show that the curves acquired by the sensing array can accurately reflect the information of the relative displacement when the relative displacement between the array and electrode is 10 cm. Compared with the detection method of 3D single point, the proposed array sensing method of magnetic field obtains better results in terms of real-time and accuracy, and has good practical value for industrial measurement.

Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

  • Lee, Ji Young;Hong, Sung Hwa;Moon, Il Joon;Kim, Eun Yeon;Baek, Eunjoo;Seol, Hye Yoon;Kang, Sihyung
    • Journal of Audiology & Otology
    • /
    • v.23 no.3
    • /
    • pp.145-152
    • /
    • 2019
  • Background and Objectives: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Subjects and Methods: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. Results: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. Conclusions: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.

Effect of Cochlear Implant Electrode Array Design on Electrophysiological and Psychophysical Measures: Lateral Wall versus Perimodiolar Types

  • Lee, Ji Young;Hong, Sung Hwa;Moon, Il Joon;Kim, Eun Yeon;Baek, Eunjoo;Seol, Hye Yoon;Kang, Sihyung
    • Korean Journal of Audiology
    • /
    • v.23 no.3
    • /
    • pp.145-152
    • /
    • 2019
  • Background and Objectives: The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Subjects and Methods: Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. Results: The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. Conclusions: The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.

Single Grained PZT Array Fabricated by Physical Etching of Pt Bottom Electrode

  • Park, Eung-Chul;Lee, Jang-Sik;Kim, Kwang-Ho;Park, Jung-Ho;Lee, Byung-Il
    • The Korean Journal of Ceramics
    • /
    • v.6 no.1
    • /
    • pp.74-77
    • /
    • 2000
  • Ta-doped PZT thin films prepared by reactive co-sputtering method could be transformed into single grained perovskite structure utilizing physical etching of Pt bottom electrode. It is found that PZT perovskite phase on damaged (111) Pt electrode by IMD was more easily crystallized than random oriented Pt electrode and less crystallized than (111) Pt electrode. This shows that amorphized Pt electrode surface by IMD process has an effect on crystallization of PZT perovskite phase. 40$\mu\textrm{m}\times40\mu\textrm{m}$ square shape single grain PZT array could be obtained utilizing the difference of incubation time for nucleation of rosettes between ion damaged Pt and (111) oriented Pt electrode. Single grained PZT thin films show low leakage current density of $1\times10^{-7}$ A/$\textrm{cm}^2$ and high break down field of 440kV/cm. The loss of remanent polarization after $10^{11}$ cycles was less than 15% of initial value.

  • PDF