• 제목/요약/키워드: Arrangement Type

검색결과 930건 처리시간 0.026초

A Study on the Electrical Load Matching Analisys for the optimal utilization of grid-conntected PV system in Apartment Complex (공동주택의 태양광시스템 적용성 평가를 위한 전기부하 매칭 해석연구)

  • Yoon, Jong-Ho;Park, Jae-Sung;Shin, U-Cheul;Park, Jae-Wan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.49-54
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex enough the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performing with the hourly simulations of total received insolation on each surface considering the hading effect of buildings. Electrical load profile of typical Korean apartments was investigated for the lad matching analysis. To calculate an annual total PV output, we used MERIT program which is a sourly based load matching tool developed by ESRU. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending of a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡ type revealed the best option for the maximum output of PV system.

  • PDF

Analysis of Technical Problem for Soil Compaction by Gyratory Compactor (선회다짐기를 이용한 흙의 다짐시 기술적 문제 분석)

  • Lee, Kwan-Ho;Jang, Tae-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • 제10권1호
    • /
    • pp.43-48
    • /
    • 2010
  • Proctor test A or D method of compaction is the most common laboratory test for investigation of subgrade soil characteristics, however, compression type using roller is used in the field. The differences between laboratory and field compaction have considerable error as application to subgrade soil properties of laboratory test. The investigation of compacted soil is carried into effect to solve the problem. The gyratory compactor which is made to reproduce the field density of asphalt mixture, coming from traffic loads, has an advance to compact it similar to arrangement of field aggregate particles. This gyratory compactor has several problems of investigation of compacted soil, because it has designed to make initial asphalt specimens. The main objectives of this research are grasping problems when compacted soil test using the gyratory compactor and showing solutions. It has made a comparative study of difference of the percentage of water content and weight, which are before and after compaction, about the pressure of compaction, frequency of compaction and speed of compaction. And it also has investigated finding maximum percentage of water content which not occur change of percentage of water content after compaction and searching how has an effect on drawing compaction curve.

The Crystal and Molecular Structure of Z-3-P-Tolylthio-4-Nitro-3-Hexene (Z-3-파라-톨릴치오-4-니트로-3-헥센의 결정 및 분자구조)

  • An, Jung Tae;Gene B. Carpenter
    • Journal of the Korean Chemical Society
    • /
    • 제34권2호
    • /
    • pp.130-135
    • /
    • 1990
  • The title compound (C13H17NO2S) is monoclinic, space group P21/a, with a = 13.756 (3), b = 9.310(4), c = 21.305(3) $\AA$, $\beta$ = 95.0。, Z = 8, V = 2718.11 $\AA$3, Dc = 1.23$g·{\cdot}cm-3$, (Mo k$\alpha$) = 0.71069$\AA$,$\mu$ = 2.18 cm-1, F(000) = 1071.86, T = 298, R = 0.085 for 2935 unique observed reflections with I >2.0$\sigma$(I). The structure was solved by direct methods. The C-H bond lengths and the methyl groups are fixed and refined as their ideal geometry by allowing to ride on the parent atoms. Both molecules A and B have almost same structures except for two terminal ethyl groups. The ethylene-like skeleton including the nitro group in one molecule is nearly perpendicular to the plane of the methylbenzene group and two ethyl groups form a cis-type structure which has the dfferent orientations between two molecules; in the molecule A, two terminal methyl groups being the opposite directional arrangement against the plane of its skeleton, while in the B, with the same directional structure from its plane. The molecules in the crystal are packed together by non-bonded van der Waals forces.

  • PDF

Development of the Scutes in Eightspine Stickleback, Pungitius sinensis Kaibarae (Gasterosteidae, Pisces) from Korea (한국산 잔가시고기 Pungitius sinensis Kaibarae(Gasterosteidae, Pisces)의 인판의 발달)

  • Chae, Byung-Soo;Yang, Hong-Jun
    • Korean Journal of Ichthyology
    • /
    • 제8권1호
    • /
    • pp.74-82
    • /
    • 1996
  • The developmental process of scutes in the eightspine stickleback, Pungitius sinensis kaibarae (Tanaka), was investigated. The scutes appeared first on the caudal peduncle at 13mm and then on the thoracoabdominal part at 16mm. The scutes continued to develop and then the trachurus type of scute arrangement was completed at about 20mm. Finally the number of scutes was stabilized as 32 - 33 in the fish over 22mm. The developmental state of scutes was different according to part of body but most scutes except those of anteriormost part entered into late stage at about 25mm. The scutes of anteriormost part remained as scute of middle stage even though the fish became adults. All scutes were formed around neuromasts of lateral line. Few anterior plates(up to five plates) had additional neuromasts above the plates. But scale material was not accumulated around the additional neuromasts. Relationship between Korean and Japanese eightspine stickleback and the taxonomic meaning of the additional neuromasts were discussed.

  • PDF

A Study on the PEM Electrolysis Characteristics Using Ti Mesh Coated with Electrocatalysts (Ti Mesh 처리 촉매전극을 이용한 고체고분자 전해질 전기분해 특성연구)

  • Sim, Kyu-Sung;Kim, Youn-Soon;Kim, Jong-Won;Han, Sang-Do
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제7권1호
    • /
    • pp.29-37
    • /
    • 1996
  • Alkaline water electrolysis has been commercialized as the only large-scale method for a long time to produce hydrogen and the technology is superior to other methods such as photochemical, thermochemical water splitting, and thermal decomposition method in view of efficiency and related technical problem. However, such conventional electrolyzer do not have high electric efficiency and productivity to apply to large scale hydrogen production for energy or chemical feedstocks. Solid polymer electrolyte water electrolysis using a perfluorocation exchange membrane as an $H^+$ ion conductor is considered to be a promising method, because of capability for operating at high current densities and low cell voltages. So, this is a good technology for the storage of electricity generated by photovoltaic power plants, wind generators and other energy conversion systems. One of the most important R&D topics in electrolyser is how to minimize cell voltage and maximize current density in order to increase the productivity of the electrolyzer. A commercialized technology is the hot press method which the film type electrocatalyst is hot-pressed to soild polymer membrane in order to eliminate the contact resistance. Various technologies, electrocatalyst formed over Nafion membrane surface by means of nonelectrolytic plating process, porous sintered metal(titanium powder) or titanium mesh coated with electrocatalyst, have been studied for preparation of membrane-electrocatalyst composites. In this study some experiments have been conducted at a solid polymer electrolyte water electrolyzer, which consisted of single cell stack with an electrode area of $25cm^2$ in a unipolar arrangement using titanium mesh coated with electrocatalyst.

  • PDF

Heat Transfer in Rotating Duct with $70^{\circ}$ Angled Ribs (회전하는 덕트내 설치된 $70^{\circ}$ 경사요철의 열전달 특성)

  • Choi, Chung;Lee, Sei Young;Won, Jung Ho;Cho, Hyung Hee;Park, Byung kyu
    • The KSFM Journal of Fluid Machinery
    • /
    • 제4권3호
    • /
    • pp.7-13
    • /
    • 2001
  • The present study investigates convective heat/mass transfer and flow characteristics inside a cooling passage of rotating gas-turbine blades. The rotating duct has staggered ribs with $70^{\circ}$ attack angle, which are attached on leading and trailing surfaces. Naphthalene sublimation technique is employed to determine detailed local heat transfer coefficients using the heat and mass transfer analogy. Additional numerical calculations are conducted to analyze the flow patterns in the cooling passage. The present experiments employ two-surface heating conditions in the rotating duct because the exposed surfaces to hot gas stream are pressure and suction side surfaces in the middle passages of an actual gas-turbine blade. Secondary flows are generated by Coriolis and centrifugal forces in the spanwise and streamwise directions. The ribs attached on the walls disturb the mainflow resulting in recirculation and secondary flows near the ribbed wall. The local heat transfer and flow patterns in the passage are changed significantly according to rib configurations and duct rotation speeds. Therefore, the geometry and arrangement of the ribs are important for the advantageous cooling performance. The experimental results show that the ribs enhance the heat transfer more than $70\%$ from that of the smooth duct. The duct rotation generates the heat transfer discrepancy between the leading and trailing walls due to the secondary flows induced by the Coriolis force. The overal heat transfer pattern on the leading and trailing walls for the first and second passes are depended on the rotating speed, but the local heat transfer trend is affected mainly by the rib arrangements.

  • PDF

A Study on the Architectural Characteristics Revived from the Roman Architecture - Focused on the early Renaissance Architecture Building - (로마시대 건축으로부터 재생된 건축적 특성에 관한 연구 - 초기 르네상스시대 건축물을 중심으로 -)

  • Kim, Seok-Man
    • Journal of architectural history
    • /
    • 제18권2호
    • /
    • pp.7-26
    • /
    • 2009
  • The purpose of this paper is the study on the architectural characteristics revived from the roman architecture, focused on the early renaissance architecture building. The results of study are as follow: 1. The composition system of Domus which is formed of urban house in the Roman period is presented by spatial arrangement of palace architecture centering around atrium in the Renaissance period. Thus plan type of Domus is used by atrium from which is composed of peristyle from the palace and villa in the Renaissance period. 2. The circular temple in the Roman period is composed of element such as podium, stair, peristyle centering around the basic circular plan. Bramante planed to revive above elements for the Tempietto to concept from the circular temple in the Roman period. 3. The triumphal arch in the Roman period is strong monument to the independent building in the city, but thus arch is used of church facade as the important example which is composed with building elevation in the Renaissance period. 4. The composition system and element of Roman temple which is planned to rectangular plan is composed of high podium, stair, portico, prostyle and pediment. The facade plan of church is used by the partial elements and total elements perfectly from the temple in the Roman period. 5. The linearly successive and repetitive composition which is composition system and element of aqueduct arches of same dimension shows to the palace facade, arcade for gallery space and side elevation plan of S.Fracesco church. 6. Such as background of Colloseum, Rucellai palace can be called good example which is created by the new architectural form to the creative starting point from the classical architecture from.

  • PDF

A Proposal to improve environment for multi-family housing residence in amelioration area (주거환경개선지구 다가구주택 환경 개선 방안에 관한 임차인 요구 조사연구)

  • Hwang, Sun-Hae;Kim, Da-Hae;Ahn, Chang-Hun;Lee, Yeun-Sook
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 한국주거학회 2008년 추계학술발표대회 논문집
    • /
    • pp.140-143
    • /
    • 2008
  • As the number of family living alone is expected to soar due to a change in socio-demographics like divorce, more middle-aged women returning to work, homes become smaller and so on. In addition to in 2020 these people will be increase so that 85 percent of the Koreans compose elderly living alone who is over 65. This study aims at developing a sharing-typed elderly people-centered rental model which is accessible in the community integration dimension as an alternative and finding out theirconscious, their need about residence. and we need to check about their major requirements on improvement step by step. so that we suggest the desirable way on the existing multi house. The model provides benefits in the social, economical and pragmatic dimensions as the families living alone get together and living with others, Particularly, as a residence model which reduces a psychological loneliness and at the same time enables the elderly to continue to live a life in the community while they live together with other people, this model could be a strategy which supports the "Aging in Place." This study is in progress via small group workshop which debate gradually about special subject with similar group member. So we can find the residence's preference on living environment in various condition and the member can imagine freely on their future living arrangement by giving the various informations which can be proceed in future. The workshop proceed three times. at the first workshop, we're check their living environment and satisfaction level. and second time we give the knowledge about shared-type rental house then discuss about the model. and last time we're listen to the residence's opinion.

  • PDF

A Study on the Simple Piped Water Supply System in a Rural Area (일부 농촌지역의 간이 상수도 운영실태와 개선 방안에 관한 조사연구)

  • 정문호
    • Journal of Environmental Health Sciences
    • /
    • 제17권1호
    • /
    • pp.57-66
    • /
    • 1991
  • This study was carried out for 5 years between 1984 and 1986 and 1989 and 1990. This interviewers visited 292 households to evaluate the perception of the residents using .the. Simple Piped Water Supply (SPWS), and examined the pollution source surrounding 42 SPWS facilities and water quality by the chemical and microbiological method. The purpose of this study was to find out problems linked with SPWS and to investigate more efficient way of improvement in rural water supply. The results of the study are surmnarized as follows: 1) Approximately 55% of the sampled population have been served by simple piped water supply. 2) The drinking water was mostly taken from the springs in 16 sites and valley water in 26 sites. 3) Considering the type of distribution of the SPWS, there are 28 natural gravity systems and 14 pumping systems. 4) Out of the 180 SPWS in Chun Sung Area, 74% of the SPWS facilities were used more than ten years. In addition, 40% of residents expressed the need for repairs of old facilities. 5) 48% of the SPWS facilities are neighbored with pollution source. 6) 50% of the maintenance crews were not committed totheir job but instead, the facilities were operated by some residents or community leaders who were personally concerned about quality of the facilities. 7) About 85% of the residents answered that SPWS was convenient and helpful. 8) About 57% of the residents complaind that the amount of daily water supply is not adequate. 9) About 74% of the residents felt that the water quality is high for dringking water and therefore, 52% of the facilities were not properly chlorinated. But in contrast, the biochemical tests indicated that only 28% of the SPWS met the dringking water quality standards. 10) Maintenance cost per a household ranges form 500 to 2, 000Won (1 $ = 700 Won) a month. Most of the cost was to cover the power electric charge. For the effective maintenance and arrangement of the facilities, gorvermental financial support for the maintenance is strongly recommended.

  • PDF

A Study on the Convective Heat Transfer in a Regenerative Ice Energy System by a Bundle of the Heat-pipes. (히이트파이프 다발을 이용한 냉축열시스템에서의 대류열전달에 관한 연구)

  • 권형정;김경석;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제14권4호
    • /
    • pp.57-66
    • /
    • 1990
  • In the design of an electric power plant, the capacity to meet the peak load demand is one of the important factors to be considered. This peak load usually occurs when the most of the cooling air conditioning systems are being operated during daytime in summer season, which inevitably entails the construction of an additional electric power plant. This study is aimed to carry out a basic experiment for the development of a cooling air conditioning system using the ice energy by the surplus electric power during the night-time. The experimental apparatus consists of four major parts; (1) the heating section consisting of the air duct and I.D. fan, (2) the cold section with the ice chamber, (3) the bundle of heat pipes made in a form of the staggered arrangement with ${C_y}/{d_o}$=2.0 and ${C_x}/{d_o}$=1.73, (4) the refrigerator system to cool down the ice chamber. This study involves an intensive experiment concerning the convective heat transfer of the air flow surrounding the bundle of heat pipes. This major experimental parameters are the amount of working fluid, the velocity of air and the working temperature. The major findings of the present study are as follows; (1) The optimum amount of the working fluid necessary for the horizontal heat pipes is much more than that for the vertical type. (2) The convective heat transfer coefficients of the air are coincided with the empirical equations of Grimson and ${\breve{Z}ukauskas}$. (3) The equation of the mean heat transfer coefficient obtained in the present study is ${N_um}=0.32 {Re_max^{0.63}}$.

  • PDF