• Title/Summary/Keyword: Arm pattern

Search Result 305, Processing Time 0.027 seconds

The Effect of Foot Pressure on the Irradiation of a PNF Upper Arm Pattern on Standing Posture with an Elastic Band: A Randomized Control Trial (바로 선 자세에서 탄력밴드를 이용한 PNF 팔 패턴의 방산효과가 발 압력에 미치는 영향)

  • Yang, Jae-Man;Lee, Jung-Hoon;Kang, Seung-Won
    • PNF and Movement
    • /
    • v.16 no.3
    • /
    • pp.425-432
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the relationship between foot pressure and upper arm PNF exercise conducted with elastic bands while standing. Methods: Eighteen asymptomatic patients consented to participate in the study. Foot pressure was measured in the standing position using the Gaitview system for proprioceptive neuromuscular facilitation stretching (PNF) using a right upper arm pattern. Resistance strength was varied based on the type of elastic band used (red=medium, green=heavy, and blue=extra heavy). Statistical significance of the results was evaluated using a repeated one-way ANOVA, and the Bonferroni method was used for the ad hoc test (SPSS ver. 18. for Windows). Results: A significant difference was observed in fore-foot, rear-foot, and everage pressure after upper arm PNF exercise. However, there was no significant difference according to the type of elastic band. Conclusion: Based on the results of this study, an upper arm PNF exercise with and without resistance may affect foot pressure in the standing position.

A study on the motion decision of the arm using pattern recognition of EMG signal (EMG신호의 패턴인식을 이용한 동작판정에 관한 연구)

  • 홍석교;고영길;유근호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.694-698
    • /
    • 1987
  • In this paper, the primitive and double combined motion classification of the arm is discussed using pattern recognition of EM signal. The EM signals are detected from Ag-Ag/Cl surface electrodes, and IBM PC, calculated the Likelyhood probability and the decision function on the feature space of integral absolute value. Multiclass decision rule is introduced for higher decision rate. On our experimental results from expert simulator, the decision rate of more than 78% can be obtained.

  • PDF

Change in Gait Parameters by Arm Sling Types in Healthy Adults (팔걸이 형태에 따른 정상인의 보행변수 변화)

  • Lee, Ok-Kyoung;An, Duk-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.267-276
    • /
    • 2010
  • The purpose of this study was to investigate the variations in gait parameters according to arm slings used in healthy adults. Twenty healthy adults (9 males, 11 females) participated in this study and walked at self-selected speeds on a GAITRite-instrumented carpet. They were randomly assigned conditions: without an arm sling, a care sling, a Harris hemi arm sling, a CVA sling, and a Rolyan humeral cuff sling. The following gait parameters were analyzed: the temporo-spatial parameters of gait velocity, swing phase, single support, cadence. In the comparison of parameters in each trial, step length was statistically significantly changed(p=.002). The right step length was significantly decreased in the Harris hemi arm sling and increased in the Rolyan humeral cuff sling when compared with no sling. This study found that several different types arm slings varied gait pattern in healthy adults.

A New Arm Swing Walking Pattern-based Walking Safety System (새로운 팔 스윙 보행 패턴 기반 보행 안전 시스템)

  • Lee, Kyung-Min;Lin, Chi-Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.19 no.6
    • /
    • pp.88-95
    • /
    • 2020
  • In this paper, we propose a new arm swing walking pattern-based walking safety system for safe walking of elderly pedestrians. The proposed system is a walking safety system for elderly pedestrians using haptic-based devices such as smart bands and smart watches, and arm swing-based walking patterns to solve the problem that it is difficult to recognize the fall situation of pedestrians with the existing walking patterns of lower limb movements. Use. The arm swing-based walking pattern recognizes the number of steps and the fall situation of pedestrians through the swing of the arm using the acceleration sensor of the device, and creates a database of the location of the fall situation to warn elderly pedestrians when walking near the expected fall location. It delivers a message to provide pedestrian safety to the elderly. This system is expected to improve the safe walking rights and environment of the elderly.

Microprocessor Control of a Prosthetic Arm by EMG Pattern Recognition (EMG 패턴인식을 이용한 인공팔의 마이크로프로세서 제어)

  • Hong, Suk-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.10
    • /
    • pp.381-386
    • /
    • 1984
  • This paper deals with the microcomputer realization of EMG pattern recognition system which provides identification of motion commands from the EMG signals for the on-line control of a prosthetic arm. A probabilistic model of pattern is formulated in the feature space of integral absolute value(IAV) to describe the relation between a motion command and the location of corresponding pattern. This model enables the derivation of sample density function of a command in the feature space of IAV. Classification is caried out through the multiclass sequential decision process, where the decision rule and the stopping rule of the process are designed by using the simple mathematical formulas defined as the likelihood probability and the decision measure, respectively. Some floating point algorithms such as addition, multiplication, division, square root and exponential function are developed for calculating the probability density functions and the decision measure. Only six primitive motions and one no motion are incorporated in this paper.

  • PDF

A Clothing Ergonomics Studyon the Seelve form Variation and the Clothing Pressure Variation According to Arm Movement (동작에 따른 상지형태 변화와 의복에 대한 피복인간공학적 연구(I))

  • Kim Hae-Kyung;Kim Soon-Ja;Cho Jung Mee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.12 no.2 s.27
    • /
    • pp.237-248
    • /
    • 1988
  • To access the appropriate height of sleeve cap which is required for the basic sleeve pattern according to arm movements, plaster gypsum experiment was performed. Arm movements were 5types ($0^{\circ},\;45^{\circ},\;90^{\circ},\;135^{\circ},\;180^{\circ}$) to the vertical directions in the front. The appropriateness of the pattern was analyzed by measuring clothing pressure. The results obtained were as follows: 1. Increasing the movement angle, sleeve width increased but height of sleeve cap and armhole girth decreased. 2. Increasing the movement angle, the acromion moved to the front part of bodice. 3. On the basis of the result of the height of sleeve cap, the $\frac{AH}{4} +2.5cm$ sleeve basic 4 pattern is suitable for the direction $M_1(0^{\circ}),\;M_2(45^{\circ})$, and the $\frac{AH}{5}$sleeve basic pattern is suitable for the direction $M_3(90^{\circ}),\;M_4(135^{\circ})$, and $M_5(180^{\circ})$. 4. As the movement angle and height of sleevecap increased, the part which receive high pressure increased and the difference between the hightest and the lowest clothing pressure increased. 5. By the variation of movement angle and height of sleevecap, clothing pressure of upperarm was affected more than that of shoulder blade. 6. The clothing pressure of upperarm and shoulder blades were more affected by the height of sleeve cap than the ease of breast area. 7. Considering the clothing pressure of various arm movement, the most appropriate height of sleeve cap for $M_1(0^{\circ}),\;M_2(45^{\circ})$ positions was to use the $\frac{AH}{4}$+2.5cm, and for $M_3(90^{\circ}),\;M_4(135^{\circ})$, and $M_5(180^{\circ})$, was $\frac{AH}{5}$.

  • PDF

Side-Channel Attack of Android Pattern Screen Lock Exploiting Cache-Coherent Interface in ARM Processors (ARM 캐시 일관성 인터페이스를 이용한 안드로이드 OS의 스크린 잠금 기능 부채널 공격)

  • Kim, Youngpil;Lee, Kyungwoon;Yoo, Seehwan;Yoo, Chuck
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.32 no.2
    • /
    • pp.227-242
    • /
    • 2022
  • This paper presents a Cache-Coherency Interconnect(CCI)-based Android pattern screen lock(PSL) attack on modern ARM processors. CCI has been introduced to maintain the cache coherency between the big core cluster and the little core cluster. That is, CCI is the central interconnect inside SoC that maintains cache coherency and shares data. In this paper, we reveal that CCI can be a side channel in security, that an adversary can observe security-sensitive operations. We design and implement a technique to compromise Android PSL within only a few attempts using the information of CCI in user-level applications on Android Nougat. Further, we analyzed the relationship between the pattern complexity and security. Our evaluation results show that complex and simple patterns would have similar security strengths against the proposed technique.

Pattern Recognition of EMG signals in arm movements for Human interface (휴먼 인터페이스를 위한 팔운동 근전신호 패턴인식에 관한 연구)

  • Kim, Kyoung-Ryul;Yoon, Kwang-Ho;Kim, Lark-Kyo;Nam, Moon-Hyon
    • Proceedings of the KIEE Conference
    • /
    • 2004.07d
    • /
    • pp.2356-2358
    • /
    • 2004
  • This thesis aims to investigate new approaches to the control strategies of human arm movements and its application for the human interface. By analyzing myoelectric signal(MES) from the arm movements of the normal human subjects, neurological informations obtained patterned could be used to identify different movement patterns of the arm movement. In this paper Artificial neural network for separation of the contraction patterns of four kinds of arm movements, i.e. and flexion and extension of the elbow and adduction and abduction of the forearm were adopted through computer simulation and experiments results were compared with the experimental added-load arm movements.

  • PDF

Analysis of Upper Arm Development for Sleeve Armhole Line (소매 진동둘레선 설계를 위한 위팔 체표전개도 분석에 관한 연구)

  • 이정란
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.22 no.7
    • /
    • pp.892-900
    • /
    • 1998
  • This study was done to analyze the surface development of upper arm for planning sleeve armhole line. The major conclusions of this study are: 1. The surface development by arm movements made the expansion and contraction of upper arm surface changes easily visible. Armhole lines of 90$^{\circ}$and 135$^{\circ}$~180$^{\circ}$movements deviated from those of standard posture. 2. According to regression analysis, armhole lines on the upper arm were adapted to sleeve patten, following the axillary circumference line changed to biceps line. Sleeve cap length ranged from armhole/4+2.5cm to armhole/4$\pm$0.5cm. 3. Compared to Rim's pattern method, ascending and descending amounts of armhole lines were represented as fixed values.

  • PDF

Safe Speed Limit of Robot Arm During Teaching and Maintenance Work (로보트 교시.정비작업시의 안전속도한계)

  • 김동하;임현교
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.1
    • /
    • pp.64-70
    • /
    • 1993
  • Serious injuries and deaths due to multi-jointed robot occur when a man mispercepts. especially during robot teaching and maintenance work. Since industrial robots often operate with unpredictable motion patterns, establishment of safe speed limit of robot arm is indispensable. An experimental emergency conditions were simulated with a multi-jointed robot. and response characteristics of human operators were measured. The result showed that failure type, robot arm axis. and robot arm speed had significant effects on human reaction time. The reaction time was slightly increased with robot arm speed. though it showed somewhat different pattern owing to failure type. Furthermore the reaction time to the axis which could flex or extend. acting on a workpiece directly. was fastest and its standard deviation was small. The robot arm speed limit securing a‘possible contact zone’based on overrun distance was about 25cm/sec. and in this sense the validity of safe speed limits suggested by many precedent researchers were discussed.

  • PDF