• 제목/요약/키워드: Arm Ratio

검색결과 279건 처리시간 0.031초

Digital Fluoroscopy System을 이용한 견갑면에서 일어나는 견갑상완 리듬 분석 (Analysis of Scapulohumeral Rhythm in Scapular Plane by Digital Fluoroscopy System)

  • 김재헌;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제14권3호
    • /
    • pp.92-105
    • /
    • 2002
  • This research described dynamic scapulohumeral rhythm though the measurement of inter relationship between humorous and scapular movement during elevation of the arm in the scapular plane. In the previous studies static plane film X-ray has usually been used, but the limitation of such method was that it did not show the real· movement. In this study, we investigated real movement of humorous and scapular bones by Digital fluoroscopy system. 1. In resting position, humorous was taken to lie at the average $5.97^{\circ}$ in abduction, and scapular at the average $3.66^{\circ}$ in internal rotation. 2. At the maximal abduction, humorous was abducted to the average of 181.25", and scapular was rotated externally to $51.43^{\circ}$. 3. This research has shown that there is a variety of scapulohumeral rhythm from resting position to $60^{\circ}$ abduction in elevation of humorous. This case study demonstrated that the ratio n of scapulohumeral rhythm is 3.46 to 1, but there was individual difference.

  • PDF

송전선에 의해 송전철탑에 전달되는 풍하중 저감을 위한 회전형 점탄성감쇠기 (Rotational Viscoelastic Dampers for the Mitigation of Wind Loads on Transmission Tower Transferred from Transmission Lines)

  • 문병욱;민경원
    • 한국소음진동공학회논문집
    • /
    • 제16권4호
    • /
    • pp.420-427
    • /
    • 2006
  • In this study, wind loads transmitted to a transmission tower from transmission lines are mitigated using rotational viscoelastic dampers. First, the wind load characteristics in a transmission tower is investigated considering the effect of the transmission lines through stochastic analysis. The assemblage of the transmission line and insulator are modeled as a double pendulum system connected to the SDOF model of the tower. From the result of the stochastic analysis, the background component of the overturing moment caused by the wind loads acting on the transmission lines are found to have considerable portion in the total overturning moment. Based on this observation result, a strategy Installing rotational viscoelastic damper (VED) between tower arm and transmission line is proposed for the mitigation of the transmission line reactions, which play a role as dynamic loads on a transmission tower. For the purpose of verification, time history analysis is conducted for different wind velocities and VED parameters. The analysis result shows that the rotational VED is effective for the mitigation of the background component rather than the resonance component of the transmission line reactions and achieves the reduction ratio of 50% even for higher wind speed.

냉동 후막 성형에 의한 다공성 Al2O3 필름 제조 (Fabrication of Porous Al2O3 Film by Freeze Tape Casting)

  • 신란희;구준모;김영도;한윤수
    • 한국분말재료학회지
    • /
    • 제22권6호
    • /
    • pp.438-442
    • /
    • 2015
  • Porous thick film of alumina which is fabricated by freeze tape casting using a camphene-camphor-acrylate vehicle. Alumina slurry is mixed above the melting point of the camphene-camphor solvent. Upon cooling, the camphene-camphor crystallizes from the solution as particle-free dendrites, with the $Al_2O_3$ powder and acrylate liquid in the interdendritic spaces. Subsequently, the acrylate liquid is solidified by photopolymerization to offer mechanical properties for handling. The microstructure of the porous alumina film is characterized for systems with different cooling rate around the melting temperature of camphor-camphene. The structure of the dendritic porosity is compared as a function of ratio of camphene-camphor solvent and acrylate content, and $Al_2O_3$ powder volume fraction in acrylate in terms of the dendrite arm width.

경피기주요법과 전기지방분해침이 복부지방에 미치는 임상적 관찰 (The Clinical Observation on Abdominal Fat when Carboxytherapy and Electroacupuncture were Practiced)

  • 안순선;허동석
    • 한방재활의학과학회지
    • /
    • 제19권2호
    • /
    • pp.275-287
    • /
    • 2009
  • Objectives : In order to observe clinical effects, carboxytherapy and electroacupuncture, we analyzed relation effect and patients' character, and researched correlation among reduction of BFM(Body Fat Mass), WHR(Waist-Hip Ratio) and AC(Arm Circumference). Methods : Among outpatients who had admitted to department of oriental rehabilitation medicine, Dae-Jeon oriental medicine hospital, Dae-Jeon university from January to September, 2008 for obesity treatment and abdominal fat, 44 subjects were chosen and carboxytherapy and electroacupuncture were practiced concurrently. Results : 1. The group under the concurrent practice of carboxytherapy and electroacupuncture showed significant decrease in BFM, BFR(Body Fat Rate), WHR and AC. 2. The group under the concurrent practice of carboxytherapy and electroacupuncture did not show statistical significance but showed decrease in BFM, WHR. The degree of decrease was proportional to that of obesity. 3. As AC decreased, BFM, WHR reduction tended to increase as well in the group under the concurrent practice of carboxytherapy and electroacupuncture. 4. Compared to the group under the sole practice of electroacupuncture, the group under the concurrent practice of carboxytherapy and electroacupuncture showed less change in BFM reduction and greater change in WHR reduction. Conclusions : From the above results, the concurrent practice of carboxytherapy and electroacupuncture had an effect on obesity and reducing abdominal fat, but did not show statistically significant decrease compare to the sole practice of electroacupuncture.

캠-밸브 기구에서 접촉력 최소화를 위한 캠과 종동자 형상 최적 합성 (Optimum Shape Synthesis of Cam And Follower in Cam-Valve System to Minimize Contact Force)

  • 김성훈;전혁수;박윤식
    • 대한기계학회논문집
    • /
    • 제14권3호
    • /
    • pp.534-546
    • /
    • 1990
  • 본 연구에서는 선회 종동자(oscillating follower)를 사용하는 캠 기구(대표 적인 기구중 하나인 자동차용 OHC 형 캠-밸브 기구)에 대해서 동역학적 특성을 고려하 여 종동자 형상과 캠 형상을 동시에 합성하고자 한다.

A New Method to Find Bars

  • Lee, Yun Hee;Ann, Hong Bae;Park, Myeong-Gu
    • 천문학회보
    • /
    • 제39권1호
    • /
    • pp.40.1-40.1
    • /
    • 2014
  • We have classified barred galaxies for 418 RC3 sample galaxies within z < 0.01 from SDSS DR7 using the visual inspection, ellipse fitting method and Fourier analysis. We found the bar fraction to be ~60%, 43% and 70% for each method and that the ellipse fitting method tends to miss the bar when a large bulge hides the transition from bar to disk in early spirals. We also confirmed that the Fourier analysis cannot distinguish between a bar and spiral arm structure. These systematic difficulties may have produced the long-time controversy about bar fraction dependence on Hubble sequence, mass and color. We designed a new method to fine bars by analyzing the ratio map of bar strength in polar coordinates, which yields the bar fraction of ~27% and ~32% for SAB and SB, respectively. The consistency with visual inspection reaches around 70%, and roughly 90% of visual strong bar are classified as SAB and SB in our classification. Although our method also has a weakness that a large bulge lowers the value of bar strength, the missing bar fraction in early spirals is reduced to the level of ~1/4 compared to the ellipse fitting method. Our method can make up for the demerits of the previous automatic classifications and provide a quantitative bar classification that agrees with visual classification.

  • PDF

10 mH, 100 mH 인덕턴스 표준기 정밀측정용 Modified Maxwell Bridge 개발 (Development of a Modified Maxwell Bridge for Precise Measurement of a 10 mH, 100 mH Inductance Standards)

  • 김한준;이래덕;강전홍;;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.840-842
    • /
    • 2003
  • 저 주파수에서 인덕턴스 단위(H, Henry)는 전기용량의 단위(F, Farad)로부터 Maxwell bridge 또는 LC를 이용한 resonance 방법으로써 유도가 된다. 이중 Maxwell bridge 방법은 국가의 단위표준을 유지하는 연구소 또는 기관에서 가장 많이 사용되는 "product arm" 형의 bridge로 잘 알려져 있다. 개발된 bridge는 ratio-transformer를 전압공급 쪽(source)과 신호검출 쪽(detector)에 사용하여 종래의 Maxwell bridge 평형조절 시 main balance와 Wagner balance의 2개 과정을 진행하던 것과는 달리 main balance, source balance, detector balance의 과정을 진행함으로서 기존 bridge의 불안정한 ground admittance들의 영향에 의해 나타나는 불확도를 완전히 제거하였다. 한편 개발된 bridge는 10 mH, 100 mH를 10 nF의 전기용량표준기와 $1\;k{\Omega}$, $10\;k{\Omega}$의 저항표준기로부터 유도 되도록 제작되었으며. 10 mH의 경우 $400\;Hz{\sim}5\;kHz$의 주파수 영역에서 약 $2.2{\times}10^{-6}$(k=1)의 불확도로 인덕턴스 단위를 유도할 수가 있게 되었다.

  • PDF

Non-linear analysis of dealamination fracture in functionally graded beams

  • Rizov, Victor I.
    • Coupled systems mechanics
    • /
    • 제6권1호
    • /
    • pp.97-111
    • /
    • 2017
  • The present paper reports an analytical study of delamination fracture in the Mixed Mode Flexure (MMF) functionally graded beam with considering the material non-linearity. The mechanical behavior of MMF beam is modeled by using a non-linear stress-strain relation. It is assumed that the material is functionally graded along the beam height. Fracture behavior is analyzed by the J-integral approach. Non-linear analytical solution is derived of the J-integral for a delamination located arbitrary along the beam height. The J-integral solution derived is verified by analyzing the strain energy release rate with considering the non-linear material behavior. The effects of material gradient, crack location along the beam height and material non-linearity on the fracture are evaluated. It is found that the J-integral value decreases with increasing the upper crack arm thickness. Concerning the influence of material gradient on the non-linear fracture, the analysis reveals that the J-integral value decreases with increasing the ratio of modulus of elasticity in the lower and upper edge of the beam. It is found also that non-linear material behavior leads to increase of the J-integral value. The present study contributes for the understanding of fracture in functionally graded beams that exhibit material non-linearity.

소방공무원의 장갑제작을 위한 손 치수 연구 (Hand Sizing Study for Development of Firefighting Gloves)

  • 권채령;장미나;정다운;김동은
    • 한국의류학회지
    • /
    • 제43권3호
    • /
    • pp.416-426
    • /
    • 2019
  • This study measured and analyzed male firefighters hand sizes as well as suggested data for developing firefighting gloves with a good fit. Accordingly, body dimensions related to the hand were measured for 100 male firefighters. Twenty-three measuring items related to the hand and lower arm were selected. The firefighters' measurement data were compared to general adult male measurements from the 6th Korean Anthropometric data to analyze the hand sizes characteristics of firefighters. As a result, height, hand circumference, hand breadth, wrist circumference, elbow-wrist length, forearm-fingertip length and firefighter weight were significantly larger than adult males. A correlation analysis for 23 items was conducted to select items used as standards for setting a size when manufacturing firefighting gloves. Hand length and circumference were selected as representative hand parts for making firefighting gloves. Cross analysis between hand length and circumference were conducted to find the section showing the highest distribution ratio. As a result, the highest sections were between 19cm and 21cm for hand circumference and between 18.5cm and 19.5cm for hand length, which may be suggested as the most important ranges.

Comparative evaluation of efficacy of Physics Forceps versus conventional forceps in pediatric dental extractions: a prospective randomized study

  • Elicherla, Sainath Reddy;Bandi, Sujatha;Nunna, Mahesh;Saikiran, Kanamarlapudi Venkata;Sahithi, Varada;Nuvvula, Sivakumar
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제21권6호
    • /
    • pp.547-556
    • /
    • 2021
  • Background: This study aimed to determine the efficacy of Physics Forceps in pediatric dental extractions. Methods: This was a double-blind, randomized controlled trial with a parallel-arm design and identical allocation ratio (1:1). Children (n=104) were randomly divided into two groups for extraction of mandibular primary teeth (group I: Physics Forceps; group II: conventional forceps). The outcome variables assessed in the study were the time taken for extraction, pre- and postoperative anxiety (using RMS pictorial scale), incidence of fractured teeth, and postoperative pain on the first and third days (using the Wong-Baker faces pain scale). Results: A significant reduction (P < 0.001) in intraoperative time, anxiety, and incidence of tooth fracture was confined to group I. The pain significantly reduced from the first to the third postoperative day in both groups, but the mean reduction in RMS scores in the physics forceps group was far better than that in the conventional forceps group. Conclusion: Physics Forceps aid in extraction of primary teeth with minimal trauma to supporting structures, as well as reducing anxiety in the pediatric population.