• Title/Summary/Keyword: Argon plasma

Search Result 322, Processing Time 0.031 seconds

A Study on the Characteristics of the Inductively Coupled thermal Plasma (유도 결합형 열 플라즈마의 특성 연구)

  • Sin, H.M.;Choi, K.C.;Kim, W.K.;Whang, K.W.
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.419-422
    • /
    • 1991
  • A mathematical model was developed to predict the temperature, the density, and the velocity distribution of an inductively coupled thermal plasma. It was for an atmospheric pressure argon thermal plasma generated by a 4 MHz radio frequency power. It has been shown that the hottest region can be moved toward centrial region by applying an external magnetic field. Based on the results of the simulation. an ICP(Inductively Coupled thermal Plasma) system was constructed and thermal plasma was generated.

  • PDF

Characterization of Boron Nanoparticles Synthesized with a Thermal Plasma System

  • Shin, Weon-Gyu;Girshick, Steven L.;Oh, Dong-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.369-369
    • /
    • 2011
  • In the current work, we demonstrate the gas phase plasma synthesis of ultrafine boron nanoparticles by decomposing boron trichloride (BCl3) gas in an argon-hydrogen thermal plasma and quenching the hot plasma by expansion through a ceramic nozzle, driving the homogeneous nucleation of nanoparticles. It is shown that ultrafine nanoparticles can be produced from the experiments. We also show the characterization results regarding the oxidation of boron nanoparticles at room temperature using X-ray Photoelectron Spectroscopy (XPS) and the combined Scanning Transmission Electron Microscope (STEM) and Electron Energy Loss Spectroscopy (EELS).

  • PDF

The Experimental Research On The Electrical Characteristics For The Ignition Of Plasma Jet Using The Advance Discharge Of High Frequency Voltage With Attenuation (감쇠파 고주파전압의 선행방전을 이용한 Plasma jet의 전기적 기동특성에 대한 실험적 연구)

  • Choon Saing Jhoun
    • 전기의세계
    • /
    • v.21 no.4
    • /
    • pp.27-38
    • /
    • 1972
  • This paper discusses the characteristics about the ignition of D.C. main discharge is a plasma jet generator, manufactured for trial as non-transferred type, when the electrical energy appropriate to the ignition is supplied to the gap between the electrodes by using advance discharge of attenuating high frequency voltage generated by a high frequency oscillator with mercury spark gap. These characteristics are under the influences of (a) the length of mercury gap in high frequency oscillator and the quantity of hydrogen flow supplied to it, (b) the condenser capacity of the high frequency oscillator circuit, (c) the length of plasma jet torch in D.C. main discharge circuit and the quantity of argon flow supplied to it, (d) the circuit constants of D.C. main discharge circuit. The results for these characteristics, obtained by this research, are considered to be helpful to the designs for the ignition of a plasma jet as well as the welding arc stabilizer by high frequency discharge and the high frequency arc welder.

  • PDF

Comparative Studies on Morphology of Low Temperature Ar-Plasma-treated Polymer Surfaces (알곤저온플라즈마처리된 고분자표면의 모폴로지에 대한 비교연구)

  • Seo Eun-Deock
    • Textile Coloration and Finishing
    • /
    • v.16 no.5
    • /
    • pp.35-41
    • /
    • 2004
  • Poly(ethylene terephthalate), polyimide(Kapton), and polypropylene surfaces were modified with argon low temperature plasma by RF glow discharge at 240m Torr, 40W to investigate the surface morphological changes due to the plasma treatment using atomic force microscopy(AFM). Analysis of the AFM images and Ra(average roughness) revealed that the plasma treatment resulted in significant ablation on the surfaces. The morphological changes and surface roughness, however, were different depending on material characteristics such as heat stability, presence of amorphous region, swelling phenomenon, and molecular structure of repeating unit. It was assumed that polypropylene due to its tertiary hydrogen was ablated easily compared to poly(ethylene terephthalate), and that polyimide was more resistant to the ablation than PET due to rigid skeleton of imide and stable phenyl ring structure.

EFFECT OF ARGON AND OXYGEN PLASMAS ON VARIOUS POLYETHYLENE SHEETS

  • Chen, Yashao;Hirayama, Naoki;Gomi, Masaki;Kiuchi, Kenji;Momose, Yoshihiro
    • Journal of the Korean institute of surface engineering
    • /
    • v.32 no.3
    • /
    • pp.344-350
    • /
    • 1999
  • The surface chemical structure of three kinds of polyethylene (PE): high density (HD) PE, low density (LD) PE and linear (L)-LDPE exposed to Ar and $O_2$ plasmas has been investigated using XPS. Oxygen was incorporated in a more increased amount for HDPE than for L-LDPE and LDPE. Ar plasma tended to incorporate more oxygen than $O_2$ plasma. The XPS valence band spectra for Ar plasma exhibited a clear peak assigned to $O_2$s character. By chemical derivatization method it was found that the amount of -COOH group at the surface was much greater than that of -OH group. The hydrophilic nature of plasma-treated PE increased in the order: LDPE

  • PDF

Emission spectroscopic diagnostics of argon arc Plasma in Plasma focus device for advanced lithography light source (차세대 리소그래피 빛샘 발생을 위한 플라스마 집속장치의 아르곤 아크 플라스마의 방출 스펙트럼 진단)

  • Hong, Y.J.;Moon, M.W.;Lee, S.B.;Oh, P.Y.;Song, K.B.;Hong, B.H.;Seo, Y.H.;Yi, W.J.;Shin, H.M.;Choi, E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.6
    • /
    • pp.581-586
    • /
    • 2006
  • We have generated the argon plasma in the diode chamber based on the established coaxial electrode type and investigated the emitted visible light for emission spectroscopy. We applied various voltages $2\sim3.5kV$ to the device by 0.5kV, and obtained the emission spectrum data for the focused plasma in the diode chamber on the argon pressure of 330 mTorr. The Ar I and Ar II emission line are observed. The electron temperature and ion density have been measured by the Boltzmann plot and Saha equation from assumption of local thermodynamic equilibrium (LTE) The Ar I and Ar II ion densities have been calculated to be $\sim10^{15}/cc\;and\;~10^{13}/cc$, respectively, from Saha equation.

Shape Characteristics of Exhaust Plume of Dual-Stage Plasma Thruster using Direct-Current Micro-Hollow Cathode Discharge (직류 마이크로 할로우 음극 방전을 이용한 이단 마이크로 플라즈마 추력기의 배기 플룸의 형상 특성)

  • Ho, Thi Thanh Trang;Shin, Jichul
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.3
    • /
    • pp.54-62
    • /
    • 2016
  • Micro plasma thruster (${\mu}PT$) was studied experimentally with a dual-stage micro-hollow cathode discharge (MHCD) plasma. Electrostatic-like acceleration exhibiting more directional and elongated exhaust plume was achieved by a dual layer MHCD at the total input power less than 10 W with argon flow rate of 40 sccm. V-I characteristic indicated that there was an optimal regime for dual-stage operation where the acceleration voltage across the second stage remained constant. Estimated exhaust plume length showed a similar trend to the analytic estimate of exhaust velocity which scales with an acceleration voltage. ${\mu}PT$ with multiple holes exhibited similar performance with single-hole thruster indicating that higher power loading is possible owing to decreased power through each hole. Boltzmann plot of atomic argon spectral lines showed average electron excitation temperature of about 2.6 eV (~30,170 K) in the exhaust plume.

Polymer (Polydimethylsiloxane (pdms)) Microchip Plasma with Electrothermal Vaporization for the Determination of Metal Ions in Aqueous Solution

  • Ryu, Won-Kyung;Kim, Dong-Hoon;Lim, H.B.;Houk, R.S.
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.4
    • /
    • pp.553-556
    • /
    • 2007
  • We previously reported a 27.12 MHz inductively coupled plasma source at atmospheric pressure for atomic emission spectrometry based on polymer microchip plasma technology. For the PDMS polymer microchip plasma, molecular emission was observed, but no metallic detection was done. In this experiment, a lab-made electrothermal vaporizer (ETV) with tantalum coil was connected to the microchip plasma for aqueous sample introduction to detect metal ions. The electrode geometry of this microchip plasma was redesigned for better stability and easy monitoring of emission. The plasma was operated at an rf power of 30-70 W using argon gas at 300 mL/min. Gas kinetic temperatures between 800-3200 K were obtained by measuring OH emission band. Limits of detection of about 20 ng/mL, 96.1 ng/mL, and 1.01 μ g/mL were obtained for alkali metals, Zn, and Pb, respectively, when 10 μ L samples in 0.1% nitric acid were injected into the ETV.

Human Fibroblast-derived Multi-peptide Factors and the Use of Energy-delivering Devices in Asian Patients

  • Suh, Sang Bum;Ahn, Keun Jae;Chung, Hye Jin;Suh, Ji Youn;Cho, Sung Bin
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.12-24
    • /
    • 2020
  • Human fibroblast-derived multi-peptide factors (MPFs) have been used during treatments with energy-delivering modalities to enhance energy-induced tissue reactions. Human fibroblast-derived MPFs, which include a range of growth factors and chemoattractive factors, activate and recruit fibroblasts and endothelial cells, as well as promote extracellular matrix deposition, all of which are crucial to wound repair. Interestingly, fibroblasts from different species or anatomical sites exhibit distinct transcriptional properties with high heterogeneity. In addition, the patterns of MPF secretion can differ under a range of experimental conditions. Therefore, the use of allogeneic fibroblasts and proper cultivation thereof are necessary to obtain MPFs that can enhance the epithelial-mesenchymal interactions during wound repair. Moreover, energy-delivering devices should be selected according to evidence demonstrating their therapeutic efficacy and safety on a pathological skin condition and the major target skin layers. This paper reviewed the histologic patterns of post-treatment tissue reactions elicited by several energy sources, including non-ablative and ablative fractional lasers, intense focused ultrasound, non-invasive and invasive radiofrequency, picosecond-domain lasers, and argon and nitrogen plasma. The possible role of the immediate application of human fibroblast-derived MPFs during wound repair was proposed.