• 제목/요약/키워드: Area-Ratio

검색결과 8,027건 처리시간 0.037초

3.5% NaCl 수용액 중에서의 금속과 GECM의 갈바닉 부식에 미치는 면적비의 영향 (Effect of Area Ratio on Galvanic Corrosion Between Metallic Materials and GECM in 3.5% NaCl Solution)

  • 김영식;임현권;손영일;유영란;장현영
    • Corrosion Science and Technology
    • /
    • 제9권1호
    • /
    • pp.39-47
    • /
    • 2010
  • Galvanic coupling between GECM(graphite epoxy composite material) and metallic materials can facilitate corrosion of metals and alloys because GECM is noble and electrically conductive. Galvanic corrosion is affected by many factors including metallic materials, area ratio, surface condition, and corrosivity. This work aims to evaluate the effect of area ratio on galvanic corrosion between GECM and several metals. In the case of glavanic coupling of carbon steel and Al to GECM, corrosion rate increased with increasing area ratio. Corrosion rate of sensitized STS 316S stainless steel decreased a little at an area ratio 1:1 but increased at an area ratio 30:1. It is considered to be due to that area ratio affects galvanic corrosion more in less corrosion resistant alloys. However, in case of STS 316 and Ti, galvanic coupling reduces corrosion rate by the formation of passive film.

서울시 신축한옥의 면적별 평면구성에 따른 공간적 특징에 관한 연구 (The Study on the Spatial Characteristics of the Newly-built Hanok in Seoul by Planar Configuration according to Area)

  • 정준수;양승정;김수암
    • 한국주거학회논문집
    • /
    • 제24권6호
    • /
    • pp.61-68
    • /
    • 2013
  • According to the relation of the attribution of residents, we analyzed the spatial characteristics of newly-built Hanok in Bukchon focused on a spatial area-ratio, the number of rooms, L/D/K configuration. The results are as follows: 1) Have increased the number of residents, the family members are also increased. In this study, the major formed case is 3 residents and two-generation family. 2) In the most cases, R area-ratio is the highest, next to L/D/K integrated area-ratio. While the examples that the L/D/K integrated area-ratio is lower than R area-ratio, or is also higher than R area-ratio are appeared. These examples can present that it has a tendency to secure the necessary room depending on the attribution of residents. 3) L/D/K is classified into four types of connection. And the characteristics depending on the number of rooms are as follows. L+DK is the most common type, next to LDK>LD+K>L+D+K. And L+DK is widely distributed in each sized area. And particularly, it is appeared mostly in 3R.

GIS 기반의 물순환 면적률을 활용한 창원시 도심지역의 물순환성 평가 (An Assessment of Urban Water Cycle in Changwon-si Using GIS-based Water Cycle Area Ratio)

  • 송봉근;박경훈;이택순
    • 환경영향평가
    • /
    • 제22권5호
    • /
    • pp.397-408
    • /
    • 2013
  • The purpose of this study is to analyze water cycle area ratio and spatial evaluation of water cycle in urban area of Changwon-si, Gyeongsangnam-do. Water cycle area ratio are analyzed by using spatial data of land-cover and land-use, and Hot spot analysis of GIS program was used for spatial evaluation of water cycle. The results are as below. Firstly, the high water cycle area ratio areas were forests, parks, and rivers, but urban areas covered asphalt and concrete were low under 40%. Public institutions and co-residential of urban areas were higher than others because of high area ratio of pervious land-cover. Spatial evaluation of water cycle was analyzed to vulnerable areas there are dense residential and commercial area. These areas are really occurring frequently flooding and immersion, therefore, is required water management facilities and improvement of land-cover from impervious to pervious. In the future, it will require additionally analysis of water cycle area ratio supplemented data of water management facility and ground water.

도시 토지피복별 불투수면적률과 녹지면적률에 따른 지표면 일최고온도 변화량 산정방법 (Development of calculating daily maximum ground surface temperature depending on fluctuations of impermeable and green area ratio by urban land cover types)

  • 김영란;황성환
    • 상하수도학회지
    • /
    • 제35권2호
    • /
    • pp.163-174
    • /
    • 2021
  • Heatwaves are one of the most common phenomena originating from changes in the urban thermal environment. They are caused mainly by the evapotranspiration decrease of surface impermeable areas from increases in temperature and reflected heat, leading to a dry urban environment that can deteriorate aspects of everyday life. This study aimed to calculate daily maximum ground surface temperature affecting heatwaves, to quantify the effects of urban thermal environment control through water cycle restoration while validating its feasibility. The maximum surface temperature regression equation according to the impermeable area ratios of urban land cover types was derived. The estimated values from daily maximum ground surface temperature regression equation were compared with actual measured values to validate the calculation method's feasibility. The land cover classification and derivation of specific parameters were conducted by classifying land cover into buildings, roads, rivers, and lands. Detailed parameters were classified by the river area ratio, land impermeable area ratio, and green area ratio of each land-cover type, with the exception of the rivers, to derive the maximum surface temperature regression equation of each land cover type. The regression equation feasibility assessment showed that the estimated maximum surface temperature values were within the level of significance. The maximum surface temperature decreased by 0.0450℃ when the green area ratio increased by 1% and increased by 0.0321℃ when the impermeable area ratio increased by 1%. It was determined that the surface reduction effect through increases in the green area ratio was 29% higher than the increasing effect of surface temperature due to the impermeable land ratio.

체성분 분석을 통한 사상체질의 신체 둘레 비율에 대한 연구 (Study on Body Circumference Ratio according to Sasang Constitution Using Body Composition)

  • 강준호;차윤엽
    • 동의생리병리학회지
    • /
    • 제24권2호
    • /
    • pp.338-344
    • /
    • 2010
  • The purpose of this study was to find the charateristics of Sasang Constitution, Soeumin, Soyangin and Taeumin from the result of body Circumference ratio. In this study, 324 data of body circumference were measured by body composition analysis. We analyzed the body circumference ratio by Sasang Constitution, Soeumin, Soyangin and Taeumin. Taeumin's body circumference were significantly higher than those of Soeumin and Soyangin. Soyangin's body circumference was significantly higher than that of Soeumin. Male Taeumin's muscle circumference were significantly higher than those of male Soyangin and male Soeumin. Female Taeumin's fat thickness were significantly higher than those of female Soyangin and female Soeumin. Male Soeumin's ratio of hip circumference and neck circumference to abdomen circumference were significantly higher than those of male Taeumin and male Soyangin. Male Taeumin's ratio of hip circumference to abdomen circumference were significantly lower than those of male Soeumin and male Soyangin. Female Taeumin's ratio of hip circumference and chest circumference to abdomen circumference were significantly lower than those of female Taeumin and female Soyangin. In body circumference ratio, Soyangin had no difference among Sasang Constitution. In body circumference ratio, male Soeumin had big lower area ratio and big upper area ratio to lower-middle area. Male Taeumin had big lower-middle area ratio to lower area. Female Taeumin had big lower-middle area ratio to lower area and upper-middle area.

농업용 저수지의 소수력 개발을 위한 경제성 분석 (Economic Feasibility Analysis for Development of Small Hydropower Using Agricultural Reservoirs)

  • 우재열;김진수;장훈;김영현
    • 한국농공학회논문집
    • /
    • 제53권2호
    • /
    • pp.53-60
    • /
    • 2011
  • This study was conducted to investigate the effect of hydropower factors (watershed, gross head), operation ratio and unit electricity cost on the benefit-cost ratio (B/C ratio) of small hydropower using agricultural reservoirs. The equation of B/C ratio was expressed as a function of watershed area, gross head, operation ratio and unit electricity cost. The benefit increased with watershed area, gross head and unit electricity cost, while the cost increased with watershed area and gross head but decreased with operation ratio. The B/C ratio increased with watershed area, gross head, operation ratio and unit electricity cost. While the effect of gross head on the B/C ratio decreased with watershed area, the effect of operation ratio and unit electricity cost on the B/C ratio increased with watershed area. The operation ratio is an important factor to affect the B/C ratio and therefore we need to develop hydropower for the heightened dams to expect high operation ratio due to continuous water release. The unit electricity cost is also an important factor to affect the B/C ratio and the B/C ratio was always below 1 unless unit electricity cost is over 60 Won/kWh under given conditions. The reservoirs with economic feasibility for small hydropower development were three in 21 when the equation of B/C ratio was appled to the study reservoirs. The results can be used to choose the appropriate reservoir with economic feasibility for development of small hydropower.

전산유체역학(CFD)를 활용한 정수공정에서 길이가 긴 유공관 설계 (Design of the long perforated pipe in water treatment process using CFD)

  • 조영만;유수전;노재순;빈재훈
    • 상하수도학회지
    • /
    • 제24권3호
    • /
    • pp.295-305
    • /
    • 2010
  • Role of the perforated pipe is to drain the water with equal pressure and velocity through the holes of perforated pipe. The perforated pipe is being used in many processes of water treatment system, however, the design parameter of perforated pipe is not standardized in korea. In this study, we have found the design parameter of perforated pipe in the water treatment system using the Computational Fluid Dynamics (CFD). The uniformity of outflow from the perforated pipe is directly affected according to area ratio(gross area of holes/surface area of the perforated pipe). In other words, the uniformity of outflow is improved as area ratio is smaller. Also, at the same area ratio, the uniformity of outflow is improved as number of holes is increase. Specially, in case of the two holes per length of pipe diameter(2/D) shows the most uniformity of outflow and the best hydraulic with the smaller pressure drop. The uniformity of outflow is aggravated and the pressure drop of pipe is decrease as length of pipe is longer. In case of that pipe length is 10m and above, the pressure drop decreased about 30% when diameter ratio is 40% with 0.2% of area ratio by comparison with 0.1% of area ratio.

비만 청소년에서 복부 내장지방량을 반영하는 비만지표에 대한 연구 (The Evaluation of Simple Indices of Abdominal Visceral Fat Area Among Korean Obese Adolescents)

  • 최영민;이형철;심우진;김길수;신승우
    • 한방비만학회지
    • /
    • 제6권1호
    • /
    • pp.61-67
    • /
    • 2006
  • Objectives : The purpose of this study was to determine what is useful index of abdominal visceral fat area among Korean obese adolescents. Methods : 35 obese adolescents who had visited Kirin Oriental Hospital from August 2004 to May 2006 were included in the study. Weight, height, waist and hip circumferences were measured. Abdominal visceral fat areas at L4-5 level were measured by computed tomography. The subjects were divided into two groups, according to sex. In each group, we investigated the correlation among waist circumference, waist/hip ratio, waist/height ratio, obesity degree and abdominal visceral fat area and evaluated that which one of these kinds of indices is the most useful predictor for visceral fat area in Korean obese adolescents. Results : There were significant correlation between waist circumference, waist/hip ratio, waist/height ratio and obesity index in both group. In boys waist/hip ratio had correlation with abdominal visceral fat area and in girls obesity index had significant correlation with abdominal visceral fat area. Conclusions : Our study suggests that waist/hip ratio in boys, obesity degree in girls can be a relatively good parameter for predicting abdominal visceral fat area.

  • PDF

용적실현비(A-FAR)에 영향을 미치는 용도지역별 대지특성에 대한 분석 - 서울시 주거지역 및 상업지역에서 법정용적률(L-FAR) 대비 실현된 용적률(D-FAR)을 중심으로 - (Urban Tissue, Zoning and Achieved Floor Area Ratio (A-FAR) - Focused on Developed Floor Area Ratio (D-FAR) Compared to the Legal Floor Area Ratio (L-FAR) in Residential Area and Commercial Area in Seoul -)

  • 김수현;최창규
    • 국토계획
    • /
    • 제54권2호
    • /
    • pp.33-45
    • /
    • 2019
  • The Legal Floor Area Ratio (L-FAR) has been used as a major urban planning tool for efficient management of land use, landscape, and density. The Developed Floor Area Ratio (D-FAR) in each parcel is realized by such physical and institutional factors as urban tissue, local characteristics, and zoning with the L-FAR. The Achieved Floor Area Ratio (A-FAR), the ratio of the D-FAR to the L-FAR, is the relationship between realized density and the intended/desired outcomes of the regulations. The A-FAR informs the efficiency of L-FAR and its effect on parcels, and is an indicator of the demands of real estate developments under the zoning regulation. This study used detailed data of each parcel's characteristics, including parcel size, road width, and the number of roads bordered by a parcel, to identify the influencing factors on A-FAR. This analysis confirmed that the parcel size has a non-linear negative effect in the residential zone but a linear positive effect on A-FAR in the commercial zone. The width of the parcel's frontage in the commercial zone has a positive effect on the value, while in the residential zone the narrower width has higher A-FAR. In Seoul, the residential zone has higher A-FAR than the commercial zone, which means that the former has a relatively higher development pressure but a lower designated L-FAR. This result reflects that Seoul's residential zone absorbs the demand of commercial uses because of the significant permitting of mixed land use and has high-density residential buildings.

서울 강남지역 아파트단지의 녹지면적에 따른 온도변화 모형 (Variation Profiles of Temperature by Green Area of Apartments in Gangnam, Seoul)

  • 홍석환;이경재
    • 한국환경생태학회지
    • /
    • 제18권1호
    • /
    • pp.53-60
    • /
    • 2004
  • 아파트단지 내부녹지가 온도변화에 미치는 영향을 파악하고자 서울시 서초구, 강남구, 송파구 등 한강 이남지역에 위치한 아파트단지중 36개 지역을 대상으로 연구를 수행하였다. 아파트단지 내부온도는 Landsat ETM+영상 2scene을 분석하여 추정하였으며 온도변화 영 향요인으로는 토양피복유형과 건물밀도, 식생활력도로 구분하였다. 토양피복유형과 아파트단지내 온도와의 상관관계 분석결과 녹지율은 음(-)의 상관관계를, 불투수포장율은 양(+)의 상관관계를 보였으며 건폐율은 유의성이 인정되지 않았다. 투수포장지를 녹지면적과 불투수포장면적에 각각 합산한 값과 온도값의 상관관계 분석결과 투수포장면적을 불투수포장면적에 합산하여 산출한 상관계수보다 녹지면적에 합산하는 것이 상관계수가 보다 높게 나타나 투수포장지역도 녹지지역과 함께 도시온도를 낮추는 요소로 작용하는 것으로 판단되었다. 건물밀도의 요소로 선정한 용적율은 온도값과 유의성이 없었으며 NDVl는 값이 높을수록 온도가 낮았다. 아파트단지내 온도분포모형 구축을 위해 투수+녹지율, 녹지율, 건폐율, NDVI값을 독립변수로, 대상지온도를 종속변수로 한 회귀분석 결과 두 시기 영상 모두 독립변수 중 투수+녹지율만이 회귀식에 채택되었으며 회귀식의 수정 결정 계수($R^2$)는 각각 41.4(2000년 9월)와 40.4(2001년 6월)이었다.