Design of the long perforated pipe in water treatment process using CFD

전산유체역학(CFD)를 활용한 정수공정에서 길이가 긴 유공관 설계

  • 조영만 (부산광역시 상수도사업본부 수질연구소) ;
  • 유수전 (부산광역시 상수도사업본부 수질연구소) ;
  • 노재순 (부산광역시 상수도사업본부 수질연구소) ;
  • 빈재훈 (부산광역시 상수도사업본부 수질연구소)
  • Received : 2010.04.08
  • Accepted : 2010.06.10
  • Published : 2010.06.15

Abstract

Role of the perforated pipe is to drain the water with equal pressure and velocity through the holes of perforated pipe. The perforated pipe is being used in many processes of water treatment system, however, the design parameter of perforated pipe is not standardized in korea. In this study, we have found the design parameter of perforated pipe in the water treatment system using the Computational Fluid Dynamics (CFD). The uniformity of outflow from the perforated pipe is directly affected according to area ratio(gross area of holes/surface area of the perforated pipe). In other words, the uniformity of outflow is improved as area ratio is smaller. Also, at the same area ratio, the uniformity of outflow is improved as number of holes is increase. Specially, in case of the two holes per length of pipe diameter(2/D) shows the most uniformity of outflow and the best hydraulic with the smaller pressure drop. The uniformity of outflow is aggravated and the pressure drop of pipe is decrease as length of pipe is longer. In case of that pipe length is 10m and above, the pressure drop decreased about 30% when diameter ratio is 40% with 0.2% of area ratio by comparison with 0.1% of area ratio.

Keywords

References

  1. 류성호, 권봉기, 이동우, 김광연, 정동규, 박종훈, "전산유체역학을 이용한 유공블럭형 하부집수장치의 유동해석" 대한상하수도학회.한국물환경학회 공동추계학술발표회논문집, c67-c73(2003)
  2. 박희경, 김성훈 윤재홍, 김충환, 김학철, "유공블럭형 하부집수장치의 설계 개선 방안 연구", 한국물환경학회.대한상하수도학회, 공동춘계학술발표회논문집, 301-304(2003)
  3. Susumu Kawamura, "Integrated design and operation of water treatment facilities", second editon, John wiley & sons, Inc., New York, 160-175(2000)
  4. Cao, Z., Wiley, D. E., Fane, A. G., "CFD simulations of net-type turbulence promoters in a narrow channel," J. Membr. Sci. 185, 157-176(2001) https://doi.org/10.1016/S0376-7388(00)00643-8
  5. Cockx, A., Do-quang, Z., Line, A. & Roustan, M., "Use of computational fluid dynamics for simulating hydrodynamics and mass transfer in industrial ozonation towers," Chem. Eng. Sci., 54(21), 5085-5090(1999) https://doi.org/10.1016/S0009-2509(99)00239-0
  6. Panneerselvam, R., Savithri, S., Surender, G. D., "CFD simulation of hydrodynamics of as-liquid-solid fluidised bed reactor," Chem. Eng. Sci., 64(6), 1119-1135(2009) https://doi.org/10.1016/j.ces.2008.10.052
  7. H. Wang, R. A. Falconer, Wat. Res. 32, 1529(1998) https://doi.org/10.1016/S0043-1354(98)80014-6
  8. N. S. Park, H. K. Park, H. W. Ahn, J. of Korean society of Water and Wastewater, 18(3),291(2004)
  9. A. I. Stamou, Applied Mathematical Modelling, 15(7), 351(1991) https://doi.org/10.1016/0307-904X(91)90060-3