• Title/Summary/Keyword: Area standards

Search Result 1,556, Processing Time 0.028 seconds

Eight-axis-polishing Machine for Large Off-axis Aspheric Optics

  • Rhee, Hyug-Gyo;Yang, Ho-Soon;Moon, Il-Kweon;Kihm, Hag-Yong;Lee, Jae-Hyub;Lee, Yun-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.394-397
    • /
    • 2011
  • For the purpose of fabricating off-axis aspheric optics, we propose an 8-axis-polishing machine combined with a testing tower whose height is up to 9 m. The proposed polishing machine was designed and analyzed by using a well-known finite element method. The eight axes of the machine have a synchronized motion generated by a computer, and each axis was calibrated by a heterodyne laser interferometer or an optical encoder. After calibration, the maximum positioning error of the machine was less than 2 ${\mu}m$ within a whole 2 m ${\times}$ 2 m area. A typical fabrication result of a ${\phi}1.5$ m concave mirror was also described in this manuscript.

A Calibration Study of Therapeutic Ultrasound Equipment Output Intensity Accuracy

  • Yuk, Goon-Chang;Ahn, Sang-Ho;Park, So-Hyun
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.3
    • /
    • pp.37-42
    • /
    • 2011
  • Purpose: The principal objective of this study was to evaluate the power output of ultrasound in Korean clinics and compare the value with Korean and global standards. Methods: A total of 69 units were measured for ultrasound power output. The normal range of power output level was ${\pm}30%$ of the output set according to KFDA standards. Device model, manufacturer, ERA, and BNR were obtained via simple questionnaires. A portable ultrasound power meter was used for output measurement. Results: 37 machines, with reported ERA values, were assessed for power output per unit area. Of these machines, 13 (37.14%) were considered to be compliant with US FDA standards at 0.5, 1.0, 1.5, $20W/cm^2$ and 18 (51.43%) were considered within KFDA standards. The remainder of the machines were outside the standard error and evidenced irregular output levels, even though most of them were the same model. Conclusion: Appropriate ultrasound intensity is incredibly important for safety and effective use. Therefore, the KFDA standards regarding ultrasound may require revision in light of global standards, including BNR and ERA additionally, attention should be paid to regular calibration for safe use in clinical practice.

Improvement of Standards for School Libraries Instructional Media and Equipments (학교도서관 교구·설비기준 개선 방안)

  • Song Gi-Ho
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.39 no.2
    • /
    • pp.57-84
    • /
    • 2005
  • The standards for instructional media and equipments imply an essential element for curriculum. In knowledge-based society, school libraries are an educational environment to assist curriculum, offer information literacy and reading services. Therefore the standards for school libraries instructional media and equipments are able to suggest the mission of school library media center, and it should contain suitable elements for educational roles. But the current standards are insufficient from quantitatively as well as qualitatively. So the standards, if standards for instructional media and equipments are revised, should be contain following contents. 1. facilities guidelines: 2. basic equipment plan; 3. instructional media for educational roles; 4. equipments for each essential. area space: 5. more detailed information appliances; 6. improvement of standard for special school library

A Study of Necessity to Improve Flood Control and Prevention of Creek (소하천 시설물의 치수안정성 및 방재성 강화 필요성 연구)

  • Song, Ju-Il;Kim, Jung-Soo;Yoon, Sei-Eui
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.735-738
    • /
    • 2008
  • Various characteristics of creek were not considered in designing creek for a long time. As result of that, a lot of reverse functions have been present in creek. In this study, a presentation of creek damage was investigated and differences river form creek design standards were analyzed. The damage of creeks accounts for 37.3 percent of total damage of rivers over the last 6 years. Besides, government should spend more money in restoring creeks. Considering that maintenance rate of domestic creeks is 37 %, counterplan should be prepared to prevent the damage of creeks. There are many kinds of causes in destroyed creek round. Specially, most damage was secondary that was caused by increase of flood elevation according to decrease in conveyance, local scour around structures, and failures because of inappropriate structures such as bridge, culvert, crossbeam, and drop in creek. These destroy types are in bend area. However, current creek design standards do not suggest solutions to prevent damages. Currently, there are no standards for bridge, and appropriate hight and width of culvert. Standards for crossbeam and drop could not reflect characteristics of creek. Therefore, it is need to improve the creek design standards for appropriate design and construction. That could improve flood control and prevention of creeks.

  • PDF

A New Approach to CAD/CAM Systems Data Exchange Using Plug-in Technology

  • Chernopyatov Y.A.;Chung W.j.;Lee C.M.
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.4
    • /
    • pp.8-13
    • /
    • 2005
  • Interoperability has been the problem of CAD/CAM systems. Starting from 1980's, national and international organizations have addressed the issue through development and release of standards for the exchange of geometric and nongeometric design data. To CAD/CAM vendors, the task of interpreting and implementing these standards falls into their products. This task is a balancing action between users' needs, available development resources, and the technical specifications of standards. This paper explores an area of CAD/CAM systems development, particularly the implementation of the effective exchange files translators'. A new approach is introduced, which proposes to enclose all the translation operations concerning each exchange format to a separate DLL, thus making a 'plug-in.' Then, this plug-in could be used together with the CAD/CAM system or with specialized translation software. This approach allows to create new translators rapidly and to gain the reliable, high-efficiency, and reusable program code. The second part of the paper concerns the possible problems of translators' development. These difficulties often come from the exchange standards' misunderstanding or ambiguity in standards. All examples come from the authors' practice experiences of dealing with CAD/CAM systems.

Considerations on Standardization in Smart Hospitals

  • Sun-Ju Ahn;Sungin Lee;Chi Hye Park;Da Yeon Kwon;Sooyeon Jeon;Han Byeol Lee;Sang Rok Oh
    • Health Policy and Management
    • /
    • v.34 no.1
    • /
    • pp.4-16
    • /
    • 2024
  • Smart hospitals involve the use of recent ICT (information and communications technology) technologies to improve healthcare access, efficiency, and effectiveness. Standardization in smart hospital technologies is crucial for interoperability, scalability, policy formulation, quality control, and maintenance. This study reviewed relevant international standards for smart hospitals and the organizations that develop them. Specific attention was paid to robotics in smart hospitals and the potential for standardization in this area. The study used online resources and existing standards to analyze technologies, standards, and practices in smart hospitals. Key technologies of smart hospitals were identified. Relevant standards from ISO (International Organization for Standardization) and IEC (International Electrotechnical Commission) were mapped to each core technology. Korea's leadership in smart hospital technology were highlighted. Approaches for standardizing smart hospitals were proposed. Finally, potential new international standard items for robotics in smart hospitals were identified and categorized by function: sampling, remote operation, delivery, disinfection, and movement tracking/contact tracing. Standardization in smart hospital technologies is crucial for ensuring interoperability, scalability, ethical use of artificial intelligence, and quality control. Implementing international standards in smart hospitals is expected to benefit individuals, healthcare institutions, nations, and industry by improving healthcare access, quality, and competitiveness.

The Changes of Standardization Administrative Organization and Improvement Plan (표준화행정기구의 변천과정 및 개선방안)

  • 조남호;이내형;한우철
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.24 no.66
    • /
    • pp.47-57
    • /
    • 2001
  • This thesis introduce the organization system and office regulation of standardization administrative organization for the change of times, also suggest improvement plan for its effective management. The main improvement plan refer to the standardization administrative organization\`s work, this thesis suggest, 1. Readjustment of national standardization system and effective reorganization for standards information organization. 2. For industrial standards system, the korea industrial standards should be maintained uniform system, So decentralized korea industrial standard at government ,must be unified and maintained to unique policy for its effective improvement. 3. To strengthen with international standards organization, a institutional device, budget funds, and expert should be backed up. 4. For training and education of expert, Refer to the performance of one\`s duty, the proper expert should be chosen and posted. Also, systematic training and education system for expert must be developed, So they can be on duty continuously, Finally, this thesis suggest that the necessity of systematic and unique policy must be established for high position at international area. Since the limitation of data, the future research will be performed for budget funds and personnel setup.

  • PDF

A An Experimental Study for Load Capacity and Dip Characteristic in Overhead Transmission Lines (가공송전선의 부하용량과 이도 특성에 관한 실험적 연구)

  • Kim, Sung-Duck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.177-183
    • /
    • 2010
  • Overhead transmission lines in domestic area have been built by several different design standards of dip and ground clearance. This paper describes an experimental study for evaluating load capacity and dip margin in overhead transmission lines. Such design standards for selection of overhead transmission conductors, dip and ground clearance, as well as electrical equipment technical standard are discussed. Based on daily load and weather data, several characteristics such as line utilization factor, load factor, conductor temperature and dip, etc. are analyzed, and compared with the specified levels of design standards. As a result, it is verified that DLR method can be a clue of the solving of the problem, for occurring in old transmission conductors which may be rarely operating below standards.

Noise Isolation Method at Construction Site (건설공사장 소음방지 대책)

  • Jung, Gab-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.940-948
    • /
    • 2000
  • Noise and vibration generated at construction sites become serious issues because of bigger construction projects and growing use of heavy equipment. Especially in downtown construction, noise and vibration easily exceed the legal standards that can suffer the most of surrounding residents. The number of complaints by the residents who are exposed to the noise increases as their consciousness grows. However, the Korean regulations for the construction noise and vibration only present the overall limits for target areas and times zones, and this make it difficult to take effective measures. Also in rural area, disputes between construction sites and residents arise, but the dispute resolution or taking measures are difficult because clear standards concerning cause-and-effect, estimation of effective levels, calculation of damages, and future precautions and examples lack. This paper describes legal standards regarding the noise and vibration and presents judging standards for the physical damages. This paper also introduces example public complaints that happened at Daewoo construction sites to describe the problems in the existing law and further to enable smooth construction progresses by emphasizing the seriousness of public complaints.

  • PDF

Analysis of Facility Standard for Elderly Welfare Facility by Universal Design Principle and Guideline: Focusing on Legal Regulations (유니버설 디자인의 원리와 지침에 의한 노인복지시설 기준 분석: 법률 규정을 중심으로)

  • Kim, Soo-Jung
    • Journal of Industrial Convergence
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • The purpose of this study is to analyze the facility standards of the elderly welfare facilities applying the seven principles of the universal design. The facility standards of the elderly welfare facilities were limited to the provisions of the "Enforcement Regulation of the Elderly Welfare Act". There are few legal regulations applying the universal design in the construction of the elderly welfare facilities. The facility standards are set only with the minimum requirements such as securing the safety of the user, securing the space area, functional convenience, and risk prevention. However, the contents of the regulations are limited to the minimum standards for functional convenience and safety required for living. In conclusion, in the elderly welfare facilities, the notion of universal design, which considers not only the elderly, but also service providers, employees, and general visitors, should be considered.

  • PDF