• Title/Summary/Keyword: Area of evacuation

Search Result 230, Processing Time 0.027 seconds

An Experimental Study on the Performance Characteristics of Steam Ejector (증기 이젝터의 성능특성에 관한 실험적 연구)

  • 김경식;이종수;김원영;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.15 no.5
    • /
    • pp.30-37
    • /
    • 1991
  • Steam ejector systems are widely used for the evacuation systems because of their high working confidence and simlicity. And recently these are used as the thermo-compressors in various energy saving systems. In this practical experiment, we have obtained the results as follows : (1) The velocity coefficient of the motive steam nozzle was 0.92-0.98. (2) The optimal area ratio was 0.00625 at pressure ratio 5.2 and expansion ratio 101.3. (3) The performance and efficiency of the steam ejector were mainly affected by the axial position of nozzle. (4) The good performance of the domestic manufactured steam ejector was confirmed in comparison with the foreign one. And by experimental results, we have carried out the improvement of Computer Aided Design Program of steam ejector which will be helpful for systematic research into the steam ejector.

  • PDF

A Study on the Protection of Smoke Control Performance in Building Enclosure to Prevent the Expansion of Smoke in Fire (화재시 연기확대 방지를 위한 건축물 구획공간에서의 방연성능 확보에 관한 조사 연구)

  • Jin, Seung-Hyeon;Kim, Hye-Won;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.91-92
    • /
    • 2019
  • In case of fire in a compartmentalized building area, a number of casualties are caused by smoke production. Accordingly, openings, penetrations and joints in compartmentalized spaces should be secured not only for fire resistance but also for smoke-proofing. However, domestic test regulations stipulate test methods for refractory performance of penetrations and joints, but do not specify separate deferral performance. In the case of openings, the test for the smoke performance exists at room temperature, but the smoke performance at high temperature is not secured, so countermeasures are needed.

  • PDF

Crowdsourced Design Evaluation Methodology for Architectural Education (크라우드소싱을 이용한 건축 디자인 평가 방법 연구)

  • Shin, Dongyoun
    • Journal of KIBIM
    • /
    • v.13 no.1
    • /
    • pp.33-40
    • /
    • 2023
  • In architectural design studios, students' needs are evaluated from a diverse and objective point of view. And the evaluation process and results are to use a design evaluation method that everyone can recognize. Therefore, in this study, we propose Crowdsourcing, in which a large number of participants participate in the evaluation to solve fundamental problems. However, the field of architecture is an area in which expertise such as evacuation, firefighting, rescue, and regulations is essential. Therefore, we expanded the concept by participation of a large number of architects, not the general public. And It presented a new word, Prowdsourcing. Prowdsourcing is a group of architects working on-line as an evaluator. It is a method that can have objectivity and expertise of evaluation at the same time. Therefore, prowdsourcing will provide students with a variety of objective assessments, which will be a recognized design evaluation method by everyone.

Characteristics of Outgas from Heated Barrier Rib for POP (PDP용 격벽재의 승온 탈가스 특성)

  • 김선호;주정훈;이석영;이강욱;오상진
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.3
    • /
    • pp.185-190
    • /
    • 2004
  • Plasma Display Panel is a display device emitting fluorescent light from gas discharge between a front and a rear panel sealed together. Front and rear panel have multitude of film layers and barrier ribs in the rear panel has the largest area so releasing various gases and affecting light emitting characteristics and lifetime. The remaining gases in a barrier rib were studied by thermal desorption analysis up to $400^{\circ}C$ and main gases were $H_2$ $H_2$O, CO. During sustaining at $300^{\circ}C$, the outgassing rates from other gases were decreased but$ H_2$ kept constantly increasing until 1 hour, which can be originated from the dissociation of organics remained in the inside of barrier rib material. In $H_2$O, two distinct peaks were observed: desorption from physically adsorbed one at $l00^{\circ}C$ and from chemically adsorbed one $400^{\circ}C$. The result can be utilized in interpretation of electronic and optical characteristics and evacuation process control of PDP

Analysis of Safety Consciousness 6th year in Elementary school (초등학교학생의 안전의식 실태분석 연구 - 6학년 학생들을 중심으로 -)

  • Han, Hyun-Sang;Son, Ki-Sang
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.1
    • /
    • pp.59-68
    • /
    • 2011
  • This study is to find out how much elementary school members have their consciousness against safety in their school. Simple questionnaire 1206 sheets have been distributed to the members and additional interview with teachers to take care of them. Statistically, frequency, and correlation analysis have been made and chi-test has also been made for data reliability. The results of these have been summarized as running on corridor with 53.4% in school safety, warming up exercise 45.2% in leisure safety, evacuation form classroom with 2.4% in fire safety, crossing around just in fromt or rear of vehicle with 61.2% in transportation safety. It is thought that safety training should be provided to more for man than for girl pupils and also, safety consciousness should be improved than all the other area.

Damages, Human Behaviour and Recovery of Urban Residents in the 2005 West off Fukuoka Earthquake

  • Murakami, H.
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.13-18
    • /
    • 2008
  • The 2005 west off Fukuoka earthquake with Mjma 7.0 occurred in the vicinity of Fukuoka city with 1.4 million populations, which had been regarded as rather seismically inactive in Japan. The strong motion records by K-net indicated PGV of 64 cm/s in Fukuoka city and some condominium buildings sustained extensive non-structural damages. In this study, we conducted a questionnaire survey for residents of 8 condominium buildings located in the downtown area of Fukuoka city after the earthquake. The results indicate that damaged nonstructural walls and distorted doors disrupted evacuation route for many occupants, and furniture and content damage on upper floors became severer resulting in higher rates of human casualty. Earthquake preparedness for indoor safety was raised after the earthquake, though further safety measures can be advised. In the phase of post-earthquake emergency and restoration period, residents' management organizations play important roles, so that neighborhood activities to promote communication networks are important in urban environment with aging population.

  • PDF

Study on the Application Possibility of Heating-cooling system with Smoke ventilation duct to Standard Apartment (공동주택의 제연겸용 덕트형 냉난방 공급시스템의 적용가능성에 관한 연구)

  • Chun, Jung-Gil;Park, Jung-Han;Son, Won-Tug
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.468-473
    • /
    • 2008
  • Currently, most of the buildings have been the high-rise buildings and not only the damage for people but also loose of property have been increased significantly. Furthermore, the damage for residents in indoor is increased significantly, the law related to fire protection is not established yet. We discussed safety of evacuation according to unitary system in standard apartment. At a result, when installing the smoke ventilation system, the RSET has been achieved and delay effect for reaching time of CO and smoke area has been obtained.

  • PDF

The Psychological Impacts of Chemical, Biological and Radiological Disasters (화학, 생물, 방사능 사고의 정신적 영향)

  • Lee, Da Young;Sim, Minyoung
    • Anxiety and mood
    • /
    • v.13 no.1
    • /
    • pp.1-9
    • /
    • 2017
  • We reviewed the scientific literature on psychological effects of Chemical, Biological, Radiological, Nuclear, Explosive (CBRNE) disaster, which is one of the biggest threat to modern society. CBRNE disaster has the potential to cause specific physical symptoms and psychological distress in victims ; moreover, various toxic symptoms and carcinogenesis/mutation would be an important issue. Bioterrorism can cause localized outbreaks of infectious disease or pandemic disaster. Somatization as well as posttraumatic stress symptoms and depression are the characteristic psychological symptoms in CBRNE disaster's victims. CBRNE disasters could lead to large-scale public fear and social chaos due to the difficulties involved in verifying the extent of exposure and unfamiliar area to the common people. In the evacuation process, problems associated with adjustment and conflict between victims and residents should be considered.

Case Study Of Reducing Specimen Disturbance Using Vertical Fixing Sample Frame (VFSF) (연직고정장치(VFSF)를 활용한 불교란시료의 교란효과 저감사례)

  • Lim, Beyong-Seok;Seo, Deok-Dong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.2
    • /
    • pp.55-66
    • /
    • 2006
  • The existing Highway LA-1 of US is required to be replaced for covering increasing regional demands of transportation such as Hurricane evacuation and oil industry. This 28 km crosses wetlands and is a sensitive environmental area. Huge amount of soil investigation and laboratory tests were performed with best efforts to overcome inherit errors of sampling, disturbance, and testing procedures for this project. The data scattering was corrected through using central tendency theory.

  • PDF