• Title/Summary/Keyword: Architecture structure

Search Result 4,552, Processing Time 0.036 seconds

An Efficient Instruction Prefetching Scheme Based on the Page Access Information (페이지 접근 정보에 기반한 효율적인 명령어 캐쉬 선인출 기법)

  • Shin Soong-Hyun;Kim Cheol-Hong;Jhon Chu-Shik
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.5
    • /
    • pp.306-315
    • /
    • 2006
  • In general, the hit ratio of the first level cache is one of the most important factors in determining the performance of computer systems. Prefetching from lower level memory structure is one of the most useful techniques for improving the hit ratio of the first level cache. In this paper, we propose a prefetch on continuous same page access (CSPA) scheme which improves the prefetch efficiency of the instruction cache and reduces prefetch cost at the same time. The proposed CSPA scheme traces the page addresses of executed instructions to count how many times the same memory page is accessed continuously. To increase the prefetch efficiency, the CSPA scheme initiates prefetch only if the number of accesses to the same page exceeds the threshold value. Generally, the size of a L1 cache block is smaller than that of a L2 cache block. Therefore, one L2 cache block contains a number of L1 cache blocks. To reduce the number of unnecessary accesses to the L2 cache due to prefetch, the CSPA scheme enables prefetch only when the missed L1 block and the prefetch L1 block are in the same L2 cache block, leading to reduced prefetch cost. According to our simulations, the proposed prefetching scheme improves the performance by up to 6.7%.

Load Balancing of Unidirectional Dual-link CC-NUMA System Using Dynamic Routing Method (단방향 이중연결 CC-NUMA 시스템의 동적 부하 대응 경로 설정 기법)

  • Suh Hyo-Joon
    • The KIPS Transactions:PartA
    • /
    • v.12A no.6 s.96
    • /
    • pp.557-562
    • /
    • 2005
  • Throughput and latency of interconnection network are important factors of the performance of multiprocessor systems. The dual-link CC-NUMA architecture using point-to-point unidirectional link is one of the popular structures in high-end commercial systems. In terms of optimal path between nodes, several paths exist with the optimal hop count by its native multi-path structure. Furthermore, transaction latency between nodes is affected by congestion of links on the transaction path. Hence the transaction latency may get worse if the transactions make a hot spot on some links. In this paper, I propose a dynamic transaction routing algorithm that maintains the balanced link utilization with the optimal path length, and I compare the performance with the fixed path method on the dual-link CC-NUMA systems. By the proposed method, the link competition is alleviated by the real-time path selection, and consequently, dynamic transaction algorithm shows a better performance. The program-driven simulation results show $1{\~}10\%$ improved fluctuation of link utilization, $1{\~}3\%$ enhanced acquirement of link, and $1{\~}6\%$ improved system performance.

The Property Evaluation of the Marine Concrete Structure Constructed in the Period of Japanese Occupancy (YoungDo Bridge) (일제시대 건설된 해양 콘크리트구조물의 물성 평가(영도대교))

  • Park, Dong-Cheon;Ahn, Jae-Cheol
    • Journal of Navigation and Port Research
    • /
    • v.37 no.2
    • /
    • pp.165-171
    • /
    • 2013
  • YoungDo bridge is the first suspension bridge in Busan which experienced several times repair and reinforcement after completion in 1934. The bridge is under demolition for extension and restoration work since 2011. The purpose of this research is to establish data base about modern concrete. The mix design of the concrete is like that cement : fine aggregate : coarse aggregate = 1 : 2 : 4 or 1 : 3 : 6 by the parts. The compressive strength is in the ranges from 50 to 55 MPa and the elastic modulus is in the ranges from 25 to 35 GPa. From the fact that the deviation is less than 10 %, considerably high quality control was conducted in those days. The carbonation depth is 5.92 cm at the bridge post and 14.3 cm at the machine room. That is why ocean environment keeps the high humidity. The diffusion coefficient of chloride ion through the pores in concrete is 1.052e-12 $m^2/s$ from the regression analysis using the experiment data. The water cement ration is estimated at approximately 35 % in case if the concrete using ordinary Portland cement.

Service Level Agreement Specification Model of Software and Its Mediation Mechanism for Cloud Service Broker (클라우드 서비스 브로커를 위한 소프트웨어의 서비스 수준 합의 명세 모델과 중개 방법)

  • Nam, Taewoo;Yeom, Keunhyuk
    • Journal of KIISE
    • /
    • v.42 no.5
    • /
    • pp.591-600
    • /
    • 2015
  • SLA (Service Level Agreement) is an essential factor that must be guaranteed to provide a reliable and consistent service to user in cloud computing environment. Especially, a contract between user and service provider with SLA is important in an environment using a cloud service brokerage. The cloud computing is classified into IaaS, PaaS, and SaaS according to IT resources of the various cloud service. The existing SLA is difficult to reflect the quality factors of service, because it only considers factors about the physical Network environment and have no methodological approach. In this paper, we suggested a method to specify the quality characteristics of software and proposed a mechanism and structure that can exchange SLA specification between the service provider and consumer. We defined a meta-model for the SLA specification in the SaaS level, and quality requirements of the SaaS were described by the proposed specification language. Through case studies, we verified proposed specification language that can present a variety of software quality factors. By using the UDDI-based mediation process and architecture to interchange this specification, it is stored in the repository of quality specifications and exchanged during service binding time.

Study on the Effect of Fineness and Substitution Rate of Natural Zeolites on Chemical Reaction and Physical Properties of Cement Mortar (천연 제올라이트의 분말도와 치환율이 시멘트모르타르의 화학반응 및 물리적 특성에 미치는 영향에 관한 연구)

  • Yoon, Chang-Bok;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.3
    • /
    • pp.96-103
    • /
    • 2020
  • As a basic study for the application of natural zeolite as a concrete admixture, the compressive strength, activity factor, Ca(OH)2 quantitative analysis and XRD experiments were investigated. It is thought that SiO2, which is abundant in natural zeolite, affects the strength development by reacting with the hydration product of cement in all specimens in which natural zeolite was added according to powder level and substitution rate. As the substitution rate increases, the compressive strength decreases, which is considered to be due to the decrease in the amount of C3S and C2S minerals in the clinker, which affects the strength expression compared to the cement content of the reference mortar. The XRD crystal structure did not show a significant difference from the reference mortar, and it was confirmed that the Z2-10 (Blaine: 15,600㎠ / g) specimen with 10% substitution of natural zeolite was the best among the experimental levels. Substitution amount for use as concrete admixture is 10% substitution is most ideally seen.

Design Methods for Eccentrically Loaded Bolt Groups for the Single Plate Connections Considering Sloped Edge Distance (편심전단을 받는 단일판접합부의 경사연단거리를 고려한 볼트군의 설계법)

  • Choi, Sun Kyu;Yoo, Jung Han;Park, Jai Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.43-53
    • /
    • 2014
  • A single plate connection(SPC) consists of a plate welded to the columns and bolts connected to the beam web. The SPC is widely used for a simple shear connection of steel structure because it is easy-to-fabricated, easy-to-installed and economical. The conventional SPC is used for 2 to 12 bolts in a single vertical row. It is designed to limit the plate thickness by bolt diameter to obtain flexible and ductile connections. The design strength for eccentric shear shall be the lesser of the shear strength of bolts or bearing strength of plate and when the design strength is decided by edge distance failure, the results can be very conservative. Although the research on special solution for 'weak-plate/strong-bolt' model with 2 to 4 bolts has been conducted by L. S. Muir, and W. A. Thonton, 2004, study on generalized design procedures did not conduct. This study proposed design procedure for evaluation of the design strength of eccentric shear bolt groups on a single plate connection based on the actual edge distance and the direction of bolt reaction forces by using elastic vector method(EVM) and instantaneous center of rotation method(ICM).

The Evaluation of Pollutant Removal Efficiencies by Sedimentation Basin Types constructed at the Inlets of Irrigation Reservoirs (농업용 저수지 내 침강지의 설치유형에 따른 수질정화효율 평가)

  • Jang, Jeong-Ryeol;Choi, Sun-Hwa;Nam, Gui-Sook;Kwun, Soon-Kuk
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.8 s.157
    • /
    • pp.665-674
    • /
    • 2005
  • The aim of this study is to evaluate 3 types of sedimentation basins: dredging, shield skirt and auxiliary dam, constructed at inlets of two irrigation reservoir and to estimate the most beneficial type and fitted size, SAR(surface to area ratio), for pollutant removal efficiency(RE). For this, RE of major water quality items and change of physicochemical properties in sediments before and post construction of sedimentation basin(SB) were investigated. RE depended on SB types, water quality items and survey times with wide range from $-87\%$ to $92\%$. Long term overall removal efficiency by ROC(regression of concentration) method were $18\%$ in dredging, $29\%$ in shield skirt and $42\%$ in auxiliary dam type. There was a change of physicochemical properties in sediments at auxiliary dam type, while a slight change at dredging and shield skirt type. In comparison to RE, SAR and hydraulic retention time at 3 types of SB, auxiliary dam type was the most beneficial one. Thus, it is recommended that SB would be constructed in completely separated structure from water body of a reservoir with SAR ranged from 0.7 to $1.0\%.$

Analysis of the Spatial Structure of Kazuyo Sejima & Ryue Nishizawa's House Designs (세지마 카즈요 및 니시자와 류에 주택의 공간구조분석 연구)

  • Lee, Ki-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3220-3230
    • /
    • 2014
  • This paper analyzes the house designs of Kazuyo Sejima and Ryue Nishizawa from the 1900s to the early 2000s' works. By analyzing the degree of space integration of each house using the Convex Map of the Space Syntax Theory, this study arrived at the following conclusions in the respects of private space and public space. First, from period 1 (the 1990s) to period 2 (the first half of the 2000s), the differences between average integration values of private space and public space in their works have decreased. Over time, in general, average integration values of private space have increased, and, on the other hand, those of public space have decreased, leading to smaller differences between two sets of values, which means that, as the integration degrees of private and public spaces have become similar, the boundary which divides spaces becomes blurry. Second, in terms of private space, average integration values of private space in S-3 (House in a Plum Grove) and S-4 (House in China), works of period 2, are the highest among those values of their all 10 works. We can identify that, closure degrees of private space in their works have fallen over time. Third, in terms of public space, average integration values of I-2 (Villa in the Forest), I-5 (S-House), and I-6 (Weekend House), works of period 1, are the highest among those values of their all 10 works. Public space has become more central and open from period 1 to period 2.

The Effect of the Urban and Architectural Form Factors on Pedestrian Volume (미시공간에서 도시·건축형태요소가 보행량에 미치는 영향)

  • Lee, Gunwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.310-318
    • /
    • 2016
  • This study examined the correlation between microscopic factors and pedestrian volume in an urban environment, focusing on the microscopic factors that stimulate the pedestrian volume, such as density, diversity, network structure, accessibility, and the form of lots and buildings. In particular, factors already known to boost the pedestrian volume include density, diversity and accessibility, which are three variables strongly related to the concept of the 3Ds (Density, Diversity, Design) proposed by Cervero and Kockelman (1997) and the additional 2Ds (Distance to Transit, Destination Accessibility) suggested by Ewing et al. (2008). The analysis in this study was based on the 2010 survey of the floating population in Seoul, particularly on the data from Jongro-gu and Jung-gu in Gangbuk area. Data were established by analyzing the microscopic factors within a 500m radius around each of the 1,028 spots from which the pedestrian volume in Jongro-gu and Jung-gu was measured. The analysis showed that density, diversity and accessibility, three factors that were already known to be effective in increasing pedestrian volume, also have the same effect in Jongro-gu and Jung-gu.

A Study on security characteristics and vulnerabilities of BAS(Building Automation System) (BAS의 보안 특성 및 취약점에 관한 연구)

  • Choi, Yeon-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.669-676
    • /
    • 2017
  • Recently, due to the importance of information security, security vulnerability analysis and various information protection technologies and security systems are being introduced as a countermeasure against cyber-attacks in new as well as existing buildings, and information security studies on high-rise buildings are also being conducted. However, security system introduction and research are generally performed from the viewpoint of general IT systems and security policies, so there is little consideration of the infrastructure of the building. In particular, the BAS or building infrastructure, is a closed system, unlike typical IT systems, but has unique structural features that accommodate open functions. Insufficient understanding of these system structures and functions when establishing a building security policy makes the information security policies for the BAS vulnerable and increases the likelihood that all of the components of the building will be exposed to malicious cyber-attacks via the BAS. In this paper, we propose an architecture reference model that integrates three different levels of BAS structure (from?) different vendors. The architectures derived from this study and the security characteristics and vulnerabilities at each level will contribute to the establishment of security policies that reflect the characteristics of the BAS and the improvement of the safety management of buildings.