• 제목/요약/키워드: Architectural code

검색결과 340건 처리시간 0.028초

Analysis of extended end plate connection equipped with SMA bolts using component method

  • Toghroli, Ali;Nasirianfar, Mohammad Sadegh;Shariati, Ali;Khorami, Majid;Paknahad, Masoud;Ahmadi, Masoud;Gharehaghaj, Behnam;Zandi, Yousef
    • Steel and Composite Structures
    • /
    • 제36권2호
    • /
    • pp.213-228
    • /
    • 2020
  • Shape Memory Alloys (SMAs) are new materials used in various fields of science and engineering, one of which is civil engineering. Owing to their distinguished capabilities such as super elasticity, energy dissipation, and tolerating cyclic deformations, these materials have been of interest to engineers. On the other hand, the connections of a steel structure are of paramount importance because of their vulnerabilities during an earthquake. Therefore, it is indispensable to find approaches to augment the efficiency and safety of the connection. This research investigates the behavior of steel connections with extended end plates equipped hybridly with 8 rows of high strength bolts as well as Nitinol superelastic SMA bolts. The connections are studied using component method in dual form. In this method, the components affecting the connections behavior, such as beam flange, beam web, column web, extended end plate, and bolts are considered as parallel and series springs according to the Euro-Code3. Then, the nonlinear force- displacement response of the connection is presented in the form of moment-rotation curve. The results obtained from this survey demonstrate that the connection has ductility, in addition to its high strength, due to high ductility of SMA bolts.

Evaluation of slip coefficient of slip critical joints with high strength bolts

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Kim, Kang-Seok;Kim, Woo-Bum
    • Structural Engineering and Mechanics
    • /
    • 제32권4호
    • /
    • pp.477-488
    • /
    • 2009
  • A slip critical joint has various values to adopt the proper slip coefficient in various conditions of faying surfaces in the following codes: AISC, AIJ and Eurocode 3. However, the Korean Building Code still regulates the unique slip coefficient, 0.45, regardless of the diverse faying conditions. In this study, the slip resistance test, including five kinds of surface treatments were conducted to obtain the proper slip coefficients available to steel plate KS SM490A. The faying surfaces were comprised of a clean mill, rust, red lead paint, zinc primer, and shot blast treatment. The candidates for high strength bolts were torque-shear bolts, torque-shear bolts with zinc coating, and ASTM A490 bolts. Based on the test results, the specimens with a shot blasted surface and rusted surface exhibited $k_s$, 0.61, and 0.5, respectively. It is recommended that the specimens with zinc primer exhibit $k_s{\geq}0.40$. The clean mill treated surface had prominently lower values, 0.27. For red lead painted treatment, the thickness of the coating affects the determinant of slip coefficient, so it is necessary to establish a minimum $k_s$ of 0.2, with a coating thickness of 65 ${\mu}m$. During 1,000 hours of relaxation, the uncoated surfaces exhibited the loss of clamping force behind 3%, while the coated surfaces within a certain limited thickness exhibited the loss of clamping within a range of 4.71% and 8.37%.

정량화 시뮬레이션 모델을 활용한 단계적인 건축물에너지효율등급 향상 방안 (Stepwise Technique for Improving Building Energy Efficiency Rating Utilizing Quantified Simulation Model)

  • 김기석;김유민;김종성;오세규
    • KIEAE Journal
    • /
    • 제14권6호
    • /
    • pp.65-73
    • /
    • 2014
  • Due to the Climate change and resource shortage by global warming, various problems are rising and getting worse around the world. Many countries are doing the considerable efforts to reduce greenhouse gas emissions. The government of South Korea also plans to decrease greenhouse gas emission, the various pilot projects are underway, which includes obligation of energy efficiency 1st rating and greenhouse gas target management system of public buildings. In particular, luxurious government office buildings and energy-wasting public building have issued and emerged as a social problem. Energy efficiency improvement of the existing public office buildings are becoming an important issue recently. This study is proposed the step-by-step energy improvement model according to the building energy efficiency rate in order to reduce the energy consumption. To attain this end, I set up a base model by analyzing the current architectural conditions of the existing public office buildings and grasped the specific properties of building energy consumption through energy simulations. Furthermore, I suggested phased reduction prototypes for the reduction target of energy consumption by applying the methods of the zero energy building plan. This study is expecting that prototypes would give directions when it comes to planning the implementation policy of phased building plan factors, according the building energy consumption reduction goal in the existing public office buildings which are the subject of building energy target management system.

철근 배근 교육을 위한 증강현실 컨텐츠 개발 (Mobile Augmented Reality for Teaching Bar Placing)

  • 박우열
    • 한국건축시공학회지
    • /
    • 제18권5호
    • /
    • pp.471-477
    • /
    • 2018
  • 본 연구는 최근 건설분야에서 활용도가 높아지고 있는 증강현실 도구를 활용하여 학생들이 철근공사 배근작업을 학습할 수 있는 교육지원 컨텐츠를 개발하고 적용효과를 분석하였다. 구조도면에 대한 이해도를 높이기 위해 구조도면을 마커 이미지로 활용하였으며, 구조도면에 따라 배근된 가상의 3D 배근 모델을 화면에 겹쳐 표현하는 방식으로 증강현실을 구현하였다. 또한 3D 배근 모델과 함께 2D도면의 독도법, 이음 정착길이 기준, 부재별 구조설계기준에 따른 배근방법, 그리고 실제 배근하는 순서 등을 학습할 수 있도록 컨텐츠를 구성하였다. 적용결과 인터페이스 스타일, 지각된 유용성, 지각된 활용의 용이성, 지각된 즐거움, 활용 태도, 활용 의도 측면에서 긍정적으로 평가되었으며, 증강현실은 교육적 측면에서 시각화와 상호작용의 장점이 있기 때문에 활용가치가 높을 것으로 판단된다.

다중이용업소 실내마감재료 사용기준에 관한 연구 (A Study on Using the Interior Finishing Material using Regulation at Multiple-using Businesses)

  • 김용성;조성오
    • 한국실내디자인학회논문집
    • /
    • 제22권5호
    • /
    • pp.216-224
    • /
    • 2013
  • There are the relevant provisions that apply to building regulations about the Building codes, Fire Protection laws, and more Multi-using interior finish materials businesses etc. The differences between these regulations are as follows: The Building codes is defined the main use of the building according to facilities to used to set the scale by the use of the floor space, On the other hand, Fire Protection laws are the basic purpose and the act of using the architectural space(or sales) by separating object by fire. And Multiple-using Businesses Facilities consist of two regulations engaged in the kind of law and the size of the floor area. One building can not be based on operating facilities and together in Multiple use businesses Law. As such, the Buildings are applied to the Building codes, Fire Protection laws, such as Multi-using Businesses Facilities interior construction industry due to the structural differences in the position of the designer feeling a lot of difficulties and confusion. The Multi-use businesses Facilities engage in the kind of law, the size of the floor area and seating capacity. These can not be based on operating facilities, and consists of two regulations together in one building. This study is purposed to help improving the finish of the interior architecture that is related to the Building code regulations, Fire Protection laws, Multi-using Facilities interior finishing material relevant with the provisions from the law through analyze the case of developed countries, and the current Multiple use Businesses Facilities research range from the law of multiple-using facilities, interior finishing, interior architecture for supervision reasonably and compensation for the interior design. So, Result is as follows: First, interior decorations can be separated the fixed material and the moveable things. second, It should be included multi-using Business though small size business space at the basement floor. third, It should be established statute law that design and construction responsibility. forth, re-testing fire resist performance after some period. and finally, it need to mitigate regulation where be installed sprinkler.

계단 설치형 카고메 감쇠시스템을 활용한 철근콘크리트 라멘조 공동주택의 지진응답 개선 (Mitigating Seismic Response of the RC Framed Apartment Building Structures Using Stair-Installation Kagome Damping System)

  • 허무원;천영수;이상현;황재승
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권5호
    • /
    • pp.23-30
    • /
    • 2018
  • 최근 들어 건물의 내진 및 내풍 성능을 향상시키기 위하여 감쇠구조에 대한 관심이 높아지고 있다. 감쇠장치 중 저렴한 비용과 높은 에너지소산능력을 발휘하며, 설치와 유지관리가 용이하다는 장점이 있어 강재이력형 감쇠장치를 이용한 수동형 감쇠구조시스템이 널리 사용되고 있다. 본 논문에서는 라멘구조 또는 무량판 구조에 적합한 계단 설치형 카고메 감쇠시스템(SKDS)을 제안하고자 하며, 제안된 감쇠시스템의 지진응답 개선효과에 대하여 해석적으로 검토하고자 한다. 비선형 동적해석결과 최대응답변위, 최대응답가속도 및 밑면전단력 감소로 살펴볼 때 내진구조와 비교하여 더 향상된 거동이 기대된다는 점에서 SKDS의 효과를 확인할 수 있었다.

고강도 대형 프리스트레스트 콘크리트 보의 전단거동과 경사진 프리스트레싱 긴장재의 영향 (Shear Behavior of Large Prestressed Concrete Beams Cast with High Strength Concrete and the Effect of Draped Tendon on their Shear Behavior)

  • 김강수
    • 콘크리트학회논문집
    • /
    • 제17권6호
    • /
    • pp.963-974
    • /
    • 2005
  • 본 논문은 고강도 콘크리트로 타설된 2개의 대형 프리스트레스트 콘크리트 보로부터 얻어진 4개의 전단실험 결과를 고찰하였다. 특히 경사진 프리스트레싱 긴장재가 부재의 전단거동에 미치는 영향을 세밀히 분석하였다. 본 실험에서 경사진 프리스트레싱 긴장재를 사용한 부재는 직선 프리스트레싱 긴장재를 사용한 부재에 비해 높은 초기전단균열강도와 전단강도를 가졌다. 또한 실험 결과는 경사진 프리스트레싱 긴장재의 사용이 부재 단부에서 긴장재의 미끄러짐을 감소시켜주는 것으로 관찰되어 부재 단부에서 크게 요구되는 단부 정착력을 분산시키는데 효과적임을 보여주었다. 실험 결과로부터 얻어진 부재의 전단강도는 ACI 318-02와 AASHTO LRFD의 전단설계기준에 의하여 계산된 값과 비교 분석되었다. 두 전단설계기준은 모든 시험체에 대해 안정적인 전단강도를 제공하였으며, 특히 경사진 프리스트레싱 긴장재를 가진 부재들에 대해서 실험결과에 비해 매우 낮은 전단강도를 제공하였다.

크기최적화 이후에 나타나는 공간구조물의 후 좌굴 거동 변화에 대한 연구 (Mechanical Characteristic Test of Architectural ETFE Film Membrane)

  • 이상진;정지명
    • 한국공간구조학회논문집
    • /
    • 제9권3호
    • /
    • pp.75-82
    • /
    • 2009
  • 본 연구에서는 선형이론을 바탕으로 한 이산계열 대공간구조물의 크기최적화에 따른 후좌굴 거동의 변화에 대하여 조사하고 그 결과를 기술하였다. 먼저 공간구조물의 최적의 부재크기 패턴을 조사하기 위하여 수학적 프로그래밍 기법을 도입하였다. 이때 최소화 해야하는 공간구조물의 전체 부재의 중량을 목적함수로 이용하고 절점에서 발생하는 변위 값과 각 부재에서 발생하는 응력 값을 허용치 이하로 제한하는 제약조건으로 사용하였다. 크기최적화를 통하여 도출된 최적 부재패턴을 가지는 공간구조물의 후좌굴 거동을 통합 비선형해석기법으로 해석하고 그 결과를 분석하였다. 수치해석을 통하여 크기최적화에 따른 공간구조물의 후좌굴 거동의 변화는 매우 큰 것으로 나타났으며 이러한 후좌굴 거동의 변화에 대한 예측과 분석결과가 공간 구조물의 설계에 고려되어야 할 것으로 판단된다. 또한 본 연구에서 제시한 수치해석 결과는 이산계열 대공간구조물의 설계에 기본 데이터로 제시하였다.

  • PDF

A Study on IISS Software Architecture of Combat Management System for improving modifiability

  • Park, Ji-Yoon;Yang, Moon-Seok;Lee, Dong-Hyeong
    • 한국컴퓨터정보학회논문지
    • /
    • 제25권2호
    • /
    • pp.133-140
    • /
    • 2020
  • 정보저장 소프트웨어는 DSS(Data Sharing Service), UDP와 같은 통신 방식을 사용하여 전투관리체계에서 송/수신되는 모든 메시지를 분석컴퓨터로 전송하는 기능을 수행한다. 정보저장 소프트웨어는 전투 관리체계에서 사용되는 모든 메시지를 처리하기 때문에 소스코드의 규모가 크며 메시지 변화에 의존성이 강한 특성을 가진다. 소프트웨어의 수정은 연쇄적으로 소프트웨어 신뢰성 시험과 같은 많은 노동력을 요구하는 작업이 발생하기 때문에, 소프트웨어 수정 최소화를 비롯한 소프트웨어 개발 비용 절감을 위한 연구가 지속적으로 이루어지고 있다. 본 논문에서는 전투관리체계 정보저장 소프트웨어의 메시지 변화에 대한 의존성을 최소화하고 수정 용이성의 향상을 위한 메시지 수신 방식 및 아키텍처 구조 개선 방안을 연구하였다. DSS와 UDP 프로토콜을 통하여 메시지를 송/수신하던 기존의 방식을 Packet Sniffing으로 변경함으로써 메시지에 대한 의존성을 줄였으며 팩토리 메소드 패턴(Factory Method Pattern)을 적용하여 소프트웨어 설계를 개선하였다. 기존 소프트웨어와 개발 요소를 비교하는 시험을 통해 소프트웨어의 수정 용이성과 재사용성이 향상 된 것을 확인하였다.

선설치앵커의 동적 전단하중에 대한 저항강도: 비보강 앵커 (Shear Resistance of CIP Anchors under Dynamic Loading: Unreinforced Anchor)

  • 박용명;강문기;김동현;이종한;강충현
    • 한국강구조학회 논문집
    • /
    • 제26권1호
    • /
    • pp.11-20
    • /
    • 2014
  • 2001년 이후 앵커의 설계는 Concrete Capacity Design(CCD) 방법이 적용되고 있는데, 국내 기준에서는 지진하중에 대한 콘크리트의 파열파괴강도를 정적 파괴강도의 75%로 제한하고 있다. 본 연구에서는 무근콘크리트에 매입된 선설치앵커의 동적 전단하중에 대한 콘크리트 파열파괴강도 평가하기 위한 실험을 수행하였다. 이를 위해 직경 20 mm의 앵커에 대해 정적 하중과 동적 편진하중에 대한 실험을 각각 3개의 시험체에 대해 수행하였으며, 앵커의 연단거리는 120 mm를 적용하였다. 동적 실험은 15 cycle의 편진하중을 1 Hz의 속도로 재하하였으며 반복하중단계의 크기를 키워가면서 최종 파괴 시까지 가력하였다. 실험으로부터 동적 전단하중에 의한 콘크리트 파열파괴강도는 정적하중에 의한 것과 거의 같은 파괴강도를 보였다.