• 제목/요약/키워드: Architectural Surface

검색결과 648건 처리시간 0.027초

현대 건축의 메타모포시스적 해석과 표현에 관한 연구 (A Study on Metamorphic analysis and the expressive system in Contempory Architecture)

  • 변대중
    • 한국실내디자인학회논문집
    • /
    • 제20권1호
    • /
    • pp.14-23
    • /
    • 2011
  • The purpose of this study is to analyse the inclinations and expressions in contemporary architecture. Specially, we call this tendency and architectural movements as architectural metamorphosis. Metamorphosis in architecture present the core of the change of Forms and spirits in a change of outward shape and terrestrial identity. As in Ovid's extended dramatic poem of change and transformation, Metamorphoses, all Souls are deathless, and migrates from one form to another. Like these stories in Metamorphoses, Ovid tells the soul never dies, but leaps one form to anther, and can take any shape. So the architectural form, transformation and deformation in contemporary architecture means architectural sensations and cognitions can even approach the soul of form and shape under the transformation. The expressions and design strategies of metamorphosis in comtemporary architecture reveal continuous and sequential formations of space, linear structure with force and vector, rhythmical wavement and folding surface, lively wiggly flows of volumns and objects, and so on. Such qualities came from the periodical needs; separation of structure and surface, poly-surfacial movement, poly-sensual expression and experience, dematerialization and the dematerialized space, formless of non-formal architecture, digital architecture. Architecture of Metamorphosis is the ways and the needs of our period to overcome the static limits prohibits the liberal thoughts, to find the ways toward the opportunities and diversities and to unlock the imaginaire of the contemporary architecture.

창덕궁 낙선재 외피 열류량 실측을 통한 열관류율 산정 및 열 성능 해석 (Overall Heat Transfer Coefficients and Thermal Performance Evaluation through Heat Flux Measurement at Nakseonjae in Changdeokgung)

  • 김민휘;김진효;권오현;한욱;정재원
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.190-195
    • /
    • 2008
  • The objective of this research is to determine overall heat transfer coefficients (K-value) of exterior wall, floor, and roof of Nakseonjae, a Korean traditional residence via field measurement of transient heat flow and temperature difference across each envelope component. Heat flow sensors and T-type thermocouple were attached on the internal and the external surface of each building component, and real-time measurement data were collected for the three consecutive summer days. The K-values determined in this research showed good agreement with other results from open literature. Peak and annual thermal loads of the traditional residence estimated by a commercial energy simulation program were compared with those for a current apartment house. The traditional house showed lower annual cooling load than that of the current building. It may caused by the fact that the traditional building has less air-tight envelopes and no fenestration passing direct solar radiation into the space.

  • PDF

FDM 해석에 의한 구체축열시스템(TABS)의 난방운전시 방열 특성 분석 (Characteristic of Thermal Output of Thermally Activated Building System During the Heating Operation According to FDM Analysis)

  • 임재한;송진희;구보경;송승영;성윤복
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.218-223
    • /
    • 2012
  • This study is focused on the evaluation of thermal output of TABS (Thermally Activated Building System). The aim of this study is to evaluate TABS in terms of the temperature difference between heating medium supply temperature ($T_s$) and return temperature ($T_r$), thermal output and the surface temperature distribution according to the design flow rate and the design flow temperature. Through the transient heat transfer simulation using temperature calculation using Crank-Nicolson FDM using Physibel Voltra 6.0 W, the temperature difference between $T_s$ and ��$T_r$, thermal output and the surface temperature distribution of specific TABS was calculated and evaluated. The results show that specific thermal output and temperature difference at $60^{\circ}C$ of supply water temperature were about 162 $W/m^2$, $13.6^{\circ}C$ respectively.

Evaluation of Hydraulic Conductivity of Bentonite Filter Cake Using Modified Fluid Loss Test

  • Nguyen, The Bao;Lee, Chul-Ho;Yang, Jung-Hun;Choi, Hang-Seok
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.498-507
    • /
    • 2008
  • The mixture of bentonite powder and water is generally used to maintain the stability of excavation surface during the construction of vertical cutoff walls. The filter cake on the sidewall surface is the result of filtration of slurry into the adjacent soil formation. The filter cake is believed to have a very low hydraulic conductivity compared to that of the cutoff wall. This paper evaluates hydraulic conductivities of bentonite filter cakes set up with three types of bentonites under various pressure levels. A modified fluid loss test was employed in this experiment. Theory of filtration process was reviewed to explain the procedure in the present experiment. Hydraulic conductivity of the filter cakes with consideration of the filter medium resistance was evaluated. The results of the experiment with two calculation methods and discussion are presented to show the efficiency of the modified fluid loss test.

  • PDF

Evaluation of Hydraulic Conductivity of Bentonite Filter Cake Using Modified Fluid Loss Test

  • Nguyen, The Bao;Lee, Chul-Ho;Yang, Jung-Hun;Choi, Hang-Seok
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1502-1511
    • /
    • 2008
  • The mixture of bentonite powder and water is generally used to maintain the stability of excavation surface during the construction of vertical cutoff walls. The filter cake on the sidewall surface is the result of filtration of slurry into the adjacent soil formation. The filter cake is believed to have a very low hydraulic conductivity compared to that of the cutoff wall. This paper evaluates hydraulic conductivities of bentonite filter cakes set up with three types of bentonites under various pressure levels. A modified fluid loss test was employed in this experiment. Theory of filtration process was reviewed to explain the procedure in the present experiment. Hydraulic conductivity of the filter cakes with consideration of the filter medium resistance was evaluated. The results of the experiment with two calculation methods and discussion are presented to show the efficiency of the modified fluid loss test.

  • PDF

Flexural Strength of RC Beam Strengthened by Partially De-bonded Near Surface-Mounted FRP Strip

  • Seo, Soo-yeon;Choi, Ki-bong;Kwon, Young-sun;Lee, Kang-seok
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권2호
    • /
    • pp.149-161
    • /
    • 2016
  • This paper presents an experimental work to study the flexural strength of reinforced concrete (RC) beams strengthened by partially de-bonded near surface-mounted (NSM) fiber reinforced polymer (FRP) strip with various de-bonded length. Especially, considering high anchorage capacity at end of a FRP strip, the effect of de-bonded region at a central part was investigated. In order to check the improvement of strength or deformation capacity when the bonded surface area only increased without changing the FRP area, single and triple lines of FRP were planned. In addition, the flexural strength of the RC member strengthened by a partially de-bonded NSM FRP strip was evaluated by using the existing researchers' strength equation to predict the flexural strength after retrofit. From the study, it was found that where de-bonded region exists in the central part of a flexural member, the deformation capacity of the member is expected to be improved, because FRP strain is not to be concentrated on the center but to be extended uniformly in the de-bonded region. Where NSM FRP strips are distributed in triple lines, a relatively high strength can be exerted due to the increase of bond strength in the anchorage.

드레스룸 표면 결로 발생 예측 모델 개발 - 노달 모델과 데이터 기반 모델 - (Development of Prediction Models of Dressroom Surface Condensation - A nodal network model and a data-driven model -)

  • 주은지;이준혜;박철수;여명석
    • 대한건축학회논문집:구조계
    • /
    • 제36권3호
    • /
    • pp.169-176
    • /
    • 2020
  • The authors developed a nodal network model that simulates the flow of moist air and the thermal behavior of a target area. The nodal network model was enhanced using a parameter estimation technique based on the measured temperature, humidity, and schedule data. However, the nodal model is not good enough for predicting humidity of the target space, having 55.6% of CVRMSE. It is because re-evaporation effect could not be modeled due to uncertain factors in the field measurement. Hence, a data-driven model was introduced using an artificial neural network (ANN). It was found that the data-driven model is suitable for predicting the condensation compared to the nodal model satisfying ASHRAE Guideline with 3.36% of CVRMSE for temprature, relative humidity, and surface temperature on average. The model will be embedded in automated devices for real-time predictive control, to minimize the risk of surface condensation at dressroom in an apartment housing.

서중환경에서 표면피복 양생재 종류변화가 콘크리트의 초기 온도이력 및 균열발생에 미치는 영향에 관한 현장적용성 평가 (Field Application to Evaluate the Effect of Various Surface Covered Curing Blankets on Temperature Profile and Crack Occurrence of the Concrete under Hot Weather Condition)

  • 한민철;이상운
    • 대한건축학회논문집:구조계
    • /
    • 제34권5호
    • /
    • pp.27-34
    • /
    • 2018
  • Concrete placed under hot weather condition suffers from larger slump loss, rapid moisture evaporation due to high air temperature. Proper measures for material, transportation and curing should be taken to prevent the quality deterioration of the concrete under hot weather condition. In Korea, Although the period of hot weather concrete in Korea occupies only 2 months, there are a lot of quality problems including plastic, drying shrinkage and cold joint. Therefore, the objective of this paper is to investigate and compare the temperature history and crack occurrence of the concrete, which was placed in the actual apartment house construction field under hot weather condition, in response to the application of surface covered curing blankets including PE film, single layer clear bubble sheet, white colored bubble sheet and aluminum metalized bubble sheet. Test results indicated that the application of white colored bubble sheet and aluminum metalized bubble sheet showed most favorable results in terms of reduction in temperature rise and crack occurrence as well as easiness in handling. But, due to light reflection by aluminum metalized bubble sheet, it is believed that white colored bubble sheet is preferable.

철근부식 표면측정법 모델링을 통한 콘크리트 내 철근 탐사 (Steel Probing in Concrete Using Steel Corrosion Surface Measurement Method Modeling)

  • 임홍철;마향화;이석용;이근우;오진원
    • 콘크리트학회논문집
    • /
    • 제21권2호
    • /
    • pp.153-158
    • /
    • 2009
  • 콘크리트 표면에 4개의 전극배열을 이용한 비파괴 표면측정법을 통하여 철근의 피복을 벗겨내지 않고도 콘크리트 내 철근의 부식상태 및 철근의 배치상태를 추정할 수 있다. 표면측정법 모델링은 부식된 철근과 주위 콘크리트사이의 계면 임피던스가 콘크리트 표면에서 측정된 임피던스와 어떤 관련이 있는지를 보여준다. 본 연구에서는 콘크리트에 매립된 철근 크기와 콘크리트 피복두께 등의 탐지를 위하여 철근부식 표면측정 모델링을 이용하였다. 모델링 결과 철근 크기가 D10에서 D35로 커짐에 따라 표면임피던스 변화가 나타났으며, 또한 콘크리트 피복두께가 0.02 m에서 0.1 m로 커짐에 따라 그 변화에 대한 영향이 표면측정 임피던스를 통해 나타났다. 그러므로 표면측정법 모델링을 통하여 콘크리트 내 철근부식반응을 시뮬레이션 할 수 있으며, 동시에 철근직경과 매입 깊이 등에 대한 정보도 얻을 수 있음 알 수 있다.

버블시트 피복양생법에 의한 소성 및 건조수축 균열저감 (Plastic and Drying Shrinkage Cracking Reduction by the Bubble Sheet Curing)

  • 이정교;한천구
    • 한국건축시공학회지
    • /
    • 제16권3호
    • /
    • pp.211-217
    • /
    • 2016
  • 본 연구에서는 2015년 가을철 실제 시공중인 고층 아파트를 대상으로 1중 백색 버블시트로 타설된 콘크리트의 표면을 덮어주는 버블시트 피복양생 공법과 표면을 노출한 채로 양생없이 유지하는 표면노출 방법간을 비교하여 소성 및 건조수축균열의 저감정도를 분석하였다. 실험 결과, 버블시트를 시공하였을 경우, 수화열 및 적산온도는 표면노출보다 약간 높았고, 바닥 균열의 갯수, 길이, 최대 균열폭, 균열 면적 모두 현저하게 적은 값이 측정되었다. 따라서 가을철 버블시트를 타설된 콘크리트 표면에 적용 할 경우에는 소성 및 건조수축균열을 획기적으로 방지할 수 있는 효과적인 표면피복 양생공법인 것으로 판단되었다.