• Title/Summary/Keyword: Architectural Fabric

Search Result 46, Processing Time 0.02 seconds

A Fire Resistance Property Study of Architectural Fabric using Cone Calorimeter (콘칼로리미터를 이용한 건축용 막재의 내화 특성 연구)

  • Kim, Ji-Hyeon;Shin, Hyeon-Uk;Song, Hun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.158-159
    • /
    • 2015
  • Architectural fabrics are now used in membrane structure with the merits of free shape, lightness and opened up new possibility for the design of new building structures. Recently PVC, PVF, PVDF, PTFE coated fabric for using the membrane structures. However, clear standards for the design and construction is not exist because of the lack of Architectural fabric research. In this paper, Flammable properties of PVDF, PTFE coated fabrics are obtained through the Flammability test using the Cone Calorimeter. Based on these results, identify the fire resistance property of the Architectural fabric.

  • PDF

A Study on Fabric Effects on Contemporary Architectural Surfaces, Based on the Material Characteristics

  • Kim, Sung-Wook;Lee, So-Jung;Jeon, You-Chang
    • Architectural research
    • /
    • v.18 no.1
    • /
    • pp.31-38
    • /
    • 2016
  • The surface design in architecture plays a role as an indicator that symbolizes cultures and styles, in accordance with the course of history and the standards of the time. The surface design that determines the facade of an architectural structure allows us to have a more clear understanding about the functions, programs and structures, as well as the periodical concept of the architects than any other components of the architecture. The purpose of this paper was to examine how architectural surface designs were realized, using commonly-used materials. This study provides meaningful implications, in that it suggests common features in terms of design methodologies (between architecture and non-architecture fields), and presented new possibilities for contemporary architectural surface designs through the classification of building system methods depending on fabric properties, and through the case study analysis of architectural surface designs; in addition, the results of this study could be utilized as basic data for future studies on the possibility of the expression of surface designs across a broader domain.

Review of Test Methods for Fabric Skin Properties of Fabric-Covered Wind Turbine Blade (풍력블레이드의 패브릭 스킨재료 물성 시험방법에 대한 고찰)

  • Cho, Hyeongsun;Bae, Jae-Sung;Lee, Sooyong
    • Journal of Aerospace System Engineering
    • /
    • v.9 no.3
    • /
    • pp.31-38
    • /
    • 2015
  • Wind Turbines are becoming larger in size in order to improve economic efficiency through cost reduction, such as the construction of growth and power infrastructure of energy efficiency. It have requested the large-scale blade design and production. In the present study the new manufacture technique called a fabric-blade structure using spar, rib, and fabric membrane skin is introduced. The architectural membrane test method has been studied to be applied to the skin of the blade. The density and one-axis tensile tests of the architectural membrane materials are conducted to confirm the physical properties which are necessary to the structural designs and analyses of the wind turbine blade.

Flame Resistance Performance of Architectural Membranes Using Basalt Woven Fabric (Basalt Woven Fabric을 적용한 건축용 막재의 난연특성)

  • Kim, JiHyeon;Song, Hun;Shin, HyeonUk
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.35-42
    • /
    • 2016
  • The membrane structure provides high satisfaction with lightweight, improved workability, reduced cost, and a free shape. Thus, its applications expanding. On the other hand, in an architectural membrane that is vulnerable to fire, the development of various architectural membranes with flame resistance is in demand. Therefore, this study applied basalt woven fabric safety for flame resistance, excellent heat insulation and thermal properties on an architectural membrane. The PTFE- coated basalt woven fabric membrane was compared with a PTFE coated glass fiber membrane by DSC/TGA, strength properties, flammability, and incombustibility properties. In addition, this study confirmed the membrane applicability of basalt woven fabric and basalt-glass hybrid woven fabric through a comparison with existing architectural membranes.

A study on the change of the Building appearances according to the change of conservation policies and urban fabric in Bukchon of Seoul, since 1980's (서울 북촌(北村)의 역사경관보전정책 변천에 따른 건축물 변화)

  • Song, In-Ho;Kim, Young-Soo
    • Journal of architectural history
    • /
    • v.15 no.3
    • /
    • pp.99-118
    • /
    • 2006
  • We have focused on the building appearance according to the change of conservation policy and urban fabric in Bukchon, Seoul. The Urban Hanok, urban traditional housing type, had been evolved in modern contort from 1920's to 1960's, that is to say, many buildings(Urban Hanok) in Bukchon area has built up with a lot and road at the same time. But the change of conservation policy has an effect on the urban fabric and building(wooden structure, RC and brick building). Thus many types of building in Bukchon has undergone a various change. The purpose of this paper is to define a change factor of Bukchon buildings. Thus we need to pay attention to policy and urban fabric. We reached the result as follows. First, the change of architecture regulations according to the several policies(an aesthetic area, an altitude area for sky line restriction and so on) brought into building deformation and eventually the historic scenery of Bukchon has been spoiled. Second, the change of policy had an effect on the change of roads and lots. Buildings on a widen road and a united lot was built newly. But new buildings built up with a concrete or brick structure was not in harmony with the historic scenery of Bukchon area. Third, a development method of a large lot with lack prudence(disregarded a scale and size of lot) did damage to Urban hanok and urban fabric. With the understanding on the relationship of buildings, a urban fabric and a policy in Bukchon, we can define the identity and correspond with the urgent request for a the conservation of historic urban scenery In addition we can suggest the policy and the design guidelines for the reservation and rehabilitation for Bukchon, Seoul.

  • PDF

Experimental Study of Moisture-Wicking Fabric as Cooling Pad for Novel Rotary Direct Evaporative Cooler

  • Sang-Hwan Park;Jae-Weon Jeong
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.4
    • /
    • pp.335-341
    • /
    • 2023
  • This study proposes a novel rotary direct evaporative cooler and investigates the potential of a moisture-wicking fabric as a cooling pad for the proposed evaporative cooler. The rotary direct evaporative cooler rotates the cooling pad to reduce the water and energy consumption of the pump compared to those of existing direct evaporative coolers. A moisture-wicking fabric is considered as the material of the cooling pad, because of its high moisture-wicking property, enhancing water evaporation. Experiments are performed under various inlet air conditions while measuring the air temperature, relative humidity, air velocity, and differential pressure. The evaporative cooling efficiency and impacts of the inlet air temperature and air velocity on the cooling performance are also evaluated. The results demonstrate the potential of the moisture-wicking fabric as cooling pad of direct evaporative cooler.

Structural Behaviors for Pressurized Fabric Leaning Arches

  • Kim, Jae Yeol
    • Architectural research
    • /
    • v.3 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • In this paper, a pressurized single vertical arch and a pressurized leaning arch composed of flexible fabric material are considered. These arches have also been considered as a possible support structure for the tent-like structures. Two different boundary conditions are considered in leaning arches with fixed bases and pinned bases. The behaviors of the leaning arches are investigated for two tilt angles as 15, 30. For each angle, two loading conditions are considered as uniformly distributed load and wind loads. The F.E.M. is used through the all analysis procedures. For the results, load-deflection relationships, buckling modes, differences between two boundary conditions and deformed configurations are discussed.

  • PDF

Flame Resistance Performance of Architectural Membrane According to Woven Fabrics and Coating Materials (직포 및 코팅재 타입에 따른 건축용 막재의 난연성능)

  • Kim, Ji Hyeon;Song, Hun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.6
    • /
    • pp.545-551
    • /
    • 2016
  • Membrane structures which can be used large spatial structure are being expanded because of various advantages. However, despite the diverse membrane structure buildings and materials, the standard for membrane material performance that considering fire safety is still inadequate. Therefore, this study applied basalt or glass woven fabric with flame resistance on architectural membrane, and report the fire safety for architectural membrane using the strength properties, flammability and incombustibility. From the test result, the architectural membrane using basalt or glass woven fabric showed a low heat release rate and total heat release. Therefore, it was confirmed that the fire safety is relatively high.