A Study on Systemization of Spatial Organization with Information Theory in Architecture (정보이론을 적용한 건축공간구성의 체계화에 관한 기초연구)

  • 이기승
    • Korean Institute of Interior Design Journal
    • /
    • no.12
    • /
    • pp.109-117
    • /
    • 1997
  • The purpose of this study is about theoretical approach to scrutinize contents of spatial information and its communi-cating mechanism for revealing the interrelationship of architectural spaces and design factors in design process. It can be resulted that in architectural problem solving for adequate systemization of architectural spaces in specific conditions, intercommunication between social, psychologi-cal, perceptional aspects is important not so much as creati-ve design.

  • PDF

Control Efficiency of a Daylight Dimming System for Indirect Lighting in a Small Office (소규모 사무실 공간에서 간접조명에 대한 조광제어 시스템효율)

  • Kim, Soo-Young;Jung, Yong-Ho;Sohn, Jang-Yeul
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.33-43
    • /
    • 2006
  • Daylight dimming control system was analyzed for an indirect lighting system in a small office space with a double skin envelope system. Computer simulations were performed for photosensors with three shielding conditions. The photosensors were placed on the center of ceiling, and backwall. Three sky conditions defined by CIE were considered. Overall, control performance was not very excellent for all conditions. Fully-shielded photosensor achieved good control performance for some cases, but partially-shielded and unshielded photosensors failed to achieve target illuminance. The variation in desktop illuminance due to daylight was examined for a variety of daylight conditions. Linear correlation between desktop illuminance and photosensor illuminance was analyzed using ANOVA.

Examining Understanding and Knowledge of Time Management Perception for the Architectural Education in the United States

  • Soh, In Chul
    • Architectural research
    • /
    • v.8 no.2
    • /
    • pp.1-10
    • /
    • 2006
  • This research has acquired preliminary information about the existing conditions and understanding of members regarding time management for members in the architectural field. The goal of this research is to construct a basis for the time management education framework in architectural field in the future. This research mainly focuses on following questions based on limited objectives: Do groups of academics and professionals have understanding and knowledge of time management? Can the level of an individual's scheduling techniques be correlated to the patterns of knowledge and understanding of time management principles and practices? Can the time management practice status in individual's working environment be correlated to the patterns of knowledge and understanding of time management principles and practices? Can an individual's self-confidence level be correlated to the patterns of knowledge and understanding of time management principles and practices? Data have been collected through comprehensive questionnaires given to academics and professionals in United States. By means of statistical analysis, the hidden patterns, deficiencies and relationships in attitudes about time management have been revealed. The statistical analysis has produced conclusions that, among several subdivisions, self-discipline and planning have strong relationships and confidence, personal organization, control, and information gathering subdivisions have certain relationships with objectives of time management education in this research.

A Study on the Evaluation Method for the Degree of Integration towards Office Towers in Different Climate Zones

  • Han, Seung-Hoon;Moon, Jin Woo;Kim, Kyoung-Hee
    • Architectural research
    • /
    • v.14 no.4
    • /
    • pp.117-124
    • /
    • 2012
  • High rise office buildings represent one of the most energy-intensive architectural typologies. The growth of urban population necessitates sustainable high rise towers that lessen environmental impacts and energy consumption. Among various sustainable strategies, the integrated design is long known to be an important process that has great impact on building's sustainability. The framework for this paper is based on the case study of integrated towers that are located in different climate zones. The paper specifically addresses to what extent climate conditions influence the design of a high rise building and what kinds of the climate integrated design has been implemented. Qualitative case studies were carried out using published data and architectural drawing set. The technical work presented in the paper is based on computer simulation that examines the insolation analysis using hourly recorded weather data. The analysis results revealed that the site and building envelope integration and the site and building service systems have shown the most frequently employed in the integrated towers through the implementation of renewable resource integration, high performance envelopes and sustainable building service systems. Internal comfort and further energy saving in the integrated towers are offered through an automatic building management system. Due to the dynamic climate conditions, integration of building systems requires a sophisticated approach to building sustainability.

Determination of effective parameters on surface settlement during shield TBM

  • Kim, Dongku;Pham, Khanh;Park, Sangyeong;Oh, Ju-Young;Choi, Hangseok
    • Geomechanics and Engineering
    • /
    • v.21 no.2
    • /
    • pp.153-164
    • /
    • 2020
  • Tunnel excavation in shallow soft ground conditions of urban areas experiences inevitable surface settlements that threaten the stability of nearby infrastructures. Surface settlements during shield TBM tunneling are related to a number of factors including geotechnical conditions, tunnel geometry and excavation methods. In this paper, a database collected from a construction section of Hong Kong subway was used to analyze the correlation of settlement-inducing factors and surface settlements monitored at different locations of a transverse trough. The Pearson correlation analysis result revealed a correlation between the factors in consideration. Factors such as the face pressure, advance speed, thrust force, cutter torque, twin tunnel distance and ground water level presented a modest correlation with the surface settlement, while no significant trends between the other factors and the surface settlements were observed. It can be concluded that an integrated effect of the settlement-inducing factors should be related to the magnitude of surface settlements.

Acceptable Supply Air Conditions of Dedicated Outdoor Air System for a High-rise Apartment Building (초고층 공동주택 외기전담 시스템 기반 중앙 공급식 환기시스템의 적정 급기조건 설정)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.285-290
    • /
    • 2009
  • The main thrust of this paper is to investigate acceptable supply air conditions of a dedicated outdoor air system (DOAS) for highrise apartment buildings. As for a typical $132-m^2$ apartment unit, it was assumed that centralized DOAS-Ceiling Radiant Cooling Panel was installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program. The optimized dew point temperature of the DOAS was discussed on the basis of the ASHRAE standard 62.1-2007 and the current Korean ventilation standard for apartments. It was found that the optimized dew point temperature of the DOAS supply air accommodating total latent load of a space is $11-12^{\circ}C$ and the appropriate supply air temperature of the DOAS is $11-12^{\circ}C$ in cooling period and neutral temperature of $18-20^{\circ}C$ in intermediate period.

  • PDF

A Study on the Connection between Contemporary Ecological-Architecture and Nature (현대건축에서의 생태적 건축공간과 자연과의 관계 양상에 관한 고찰)

  • 이윤희;이영수
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.4
    • /
    • pp.56-65
    • /
    • 2004
  • Contemporary Architecture is showing many aspects on the ground of ecological paradigm, while, searching for a new architectural direction to make importance of environment that has been still little accounted of a subject of discussion. And 'sustainability'will become a central concept of a Contemporary architectural topic, continuously. With a demand of the time, ecological inclinations have been started to develop a collective low-rise housing project. It is going to expands several fields, but for reasons of social economic activity for human fundamental being, potentialities of basic problem solution are enough for ecologyㆍenvironment, but distinct direction and measures are still not obvious conditions. This study is for healing restoration in global environment, with architectural approach, through analyzing relation between ecological architectural space and nature, and abstracts various inter-relational aspect's specific character. the purpose of this study is another approach of intimate relation of ecological architecture and nature. Therefore, this study is significant to be on the search for a start to suggest a new point of view to ecological architectural space.

Tribological Performace of Architectural Fabrics (건축용 막 재료의 트라이볼로지적 고찰)

  • Choi, Won-Sik;Lee, Ihn;Park, Kang-Geun
    • Tribology and Lubricants
    • /
    • v.24 no.2
    • /
    • pp.72-76
    • /
    • 2008
  • There are 5 kinds of architectural fabrics in our country recently. The test piece were made by attaching on the steel disk which has been tested of various range of the test conditions in pin-on-disk wear testing machine. The results show that the friction coefficient and wear rate of the architectural fabrics are heavily dependent on the load and materials. PVDF type was better than others in wear rate and friction coefficient.

Comparison of Measured and Predicted Daylight Illuminances in Two Underground Spaces

  • Kim, Kang Soo;Paek, Seung Yeob;Kim, Han Seong
    • Architectural research
    • /
    • v.4 no.1
    • /
    • pp.17-23
    • /
    • 2002
  • Daylight simulation methods play an important role for the prediction of daylight illuminances in underground spaces. This daylighting project is designed to compare daylight prediction methods for the application of large underground spaces. In this study, actual measurements were conducted under overcast and clear sky conditions. Also, computer simulations by Radiance, Superlite IEA 2.0 program and scale model testings were conducted to be compared with measured data. Simulation results show the data by Radiance, Superlite IEA 2.0 and the scale model are similar to the measured data in two underground spaces in Seoul. Overall results show that Radiance and superlite IEA 2.0 proved to be useful to predict daylight illuminances even in big underground spaces.

A Study on the Operating System of the Architectural Standard Scale of Length(尺度, Korean foot) used in the Hwasong City Wall in the 18th Century (척도운용체계를 통해 본 18세기 화성건축의 건축구성에 관한 연구)

  • Lee, Ho-Rak;Lee, Sang-Hae
    • Journal of architectural history
    • /
    • v.6 no.2 s.12
    • /
    • pp.65-77
    • /
    • 1997
  • The Hwasong City Wall was built for three years(1794-1796), but the real construction term was taken only 28 months. The wall and the buildings on the wall were built simultaneously, and the esttimated construction cost was highly restricted. These conditions were main factors for considering the high efficiency of construction productivity. This study examines these factors that are reflected in the operating system of the architectural standard scale of length, the architectural composition system in the Hwasong City Wall to reduce the construction cost. Through the study, following factors are found. 1.The rule of multiple proportion is found in the relationship between the partition distance, that is, span and the height of the girder which is related to the productivity of ready-made building members. 2.The ruling grade system of scale in the component members is found in the chang-bang(창방, penetration members)

  • PDF