• Title/Summary/Keyword: Arc voltage signal

Search Result 44, Processing Time 0.025 seconds

The Analysis of Characteristics of GMAW using Sound Signal (음향 신호 분석에 의한 GMAW의 특성분석)

  • 조택동;양상민;양성빈
    • Proceedings of the KWS Conference
    • /
    • 2002.05a
    • /
    • pp.65-67
    • /
    • 2002
  • The gas metal arc welding(GMAW) is regarded as one of the best candidate for welding automation in industrial joining application. It is important to monitor the weld quality for the high performance of weld automation. The measured analog signal is frequency analyzed by digital signal process method. In order to observe the welding phenomena and control welding condition, arc light, voltage, and current are measured at the same time. They are analyzed and compared with arc sound. for these experiments, a power source of constant voltage characteristics was used in the pure metal transfer mode.

  • PDF

A Study on Weld Pool Oscillation for Pool Geometry Measurement (완전용입 풀의 진동을 이용한 형상측정에 관한 연구)

  • 유중돈
    • Journal of Welding and Joining
    • /
    • v.11 no.2
    • /
    • pp.62-73
    • /
    • 1993
  • Weld pool oscillation for the full-penetration GTA welding process was investigated for its possible application to weld penetration control through theoretical modeling and experiment. Energy method was used to estimate the natural frequency of the molten pool having the physically-acceptable weld geometry and oscillation modes. An unique experimental system was built which had the data acquisiton and video capabilities so that the pool oscillation signals and molten pool surfaces could be monitored continuously. Pool oscillation was detected through arc voltage and arc light emission simultaneously. The signal from arc light emission showed good coherence with that from arc voltage, and arc light generated the higher quality signal. The molten pool was found to oscillate in different oscillation modes based on the travel speed and weld geometry. The natural frequency estimated from the theoretical model agreed reasonably well with the experimental results.

  • PDF

A Study on the Series Arc Detection in Low-voltage Wiring Systems (저압배선계통에서 직렬아크의 검출에 관한 연구)

  • Kim, Il-Kwon;Park, Dae-Won;Choi, Su-Yeon;Park, Chan-Yong;Kim, Hwang-Kuk;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.2
    • /
    • pp.182-187
    • /
    • 2008
  • This paper dealt with the detection algorithm of series arcing, which is a cause of electric fires in low-voltage wiring systems. To find the distinguished electrical features of series arc, we simulated series arcing by the arc generator specified in UL1699. An electric heater, an inverter-controlled vacuum cleaner, and a phase-controlled incandescent lamp were used as loads to generate series arcing. A high-pass filter (HPF) with the low cut-off frequency of 3 kHz at -3 dB was fabricated and applied to separate the series arc signal from the AC voltage source. The experiment showed that the high frequency signal generates randomly during series arcing, and the phase-controlled incandescent lamp produces high frequency pulses even in normal state. In this case, the magnitude, the width, and the randomness of high frequency signal should be analyzed to estimate series arcing precisely.

A Study on On-Line Quality Monitoring Using Arc Light in Gas Metal Arc Welding (GMAW에서 아크 빛을 이용한 실시간 용접품질 모니터링에 관한 연구)

  • 조택동;양상민
    • Journal of Welding and Joining
    • /
    • v.18 no.4
    • /
    • pp.82-86
    • /
    • 2000
  • Gas metal arc welding(GMAW) is regarded as one of the best candidate for welding automation in industrial joining application. It is important to monitor the weld quality for the high performance weld automation. In GMAW, weld quality is closely related to arc stability especially. In this paper, arc light signal is measured and spectrum analyzed to the detect the variation of the weld quality. The FFT of the signal showed that the amplitude variance of FFT power spectrum was very large in poor weld process such as the decrease of weld bead width and height. The results show that it is possible to detect the weld defect position in weld process.

  • PDF

Microprocessor based welding power meter (마이크로 프로세서를 이용한 용접전력 측정에 관한 연구)

  • 노창주;박상길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.33-40
    • /
    • 1987
  • Arc power is consumed energy per unit time between welding electrodes. The relations between consumed energy and electrode distance, current, voltage are nonlinear characteristics. Therefore commercial A.C. wattmeter cannot be used for measurement of the arc power. Most of arc energy measuring systems are developed for relay contact arc measurement. Relaly arc requires integrated instantaneous power because relay arc finishes in a short instant. But most of welding powers are continually consumed powers, therefore instantaneous power must be continually indicated in the form of averagy value. The author propose a new measurement method of power in which the current and voltage of welding electrode is multiplied and the resultant signal is passed to low pass filter in order to remove higher order frequency components. After integrating, the signal is devided by the integral interval and the results are stored in a computer memory.

  • PDF

Analysis of Voltage, Current and Temperature Signals for Poor Connections at Electrical Connector (커넥터에서 접촉불량 발생시의 전압, 전류 및 온도 신호 특성 분석)

  • Kim, Sang-Chul;Kim, Doo Hyun;Kang, Shin Uk
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.12-17
    • /
    • 2014
  • This paper is aimed to analyze the characteristics of simultaneous voltage, current and temperature signals for poor connection on electrical connector. In order to attain this purpose, detected were the current and voltage signals on electric wire with series arc, named arc signals, and also monitored were the changes of RMS, instantaneous value of waveform in time domain and temperature value with video. Two states are made normal state over $5kgf{\cdot}cm$ and poor connections state below $0.5kgf{\cdot}cm$ by screw gage. In the voltage signal case, the voltage drop was increased with which the current was increased. In the current signal case, poor connections at the time interval 1~4A all showed "shoulder", as distinct difference from the normal state shown waveform pattern. In the temperature signal case, poor connections are twice at 1A and five times at 4A in the normal state. The temperature continues insulation of electrical wiring and connector can be carbonized. The results of this study will be effectively used in developing the preventive devices and system for electric fire by poor connections.

The Arc Fault Determination Method for the Electric Fire Prevention (전기화재 방지를 위한 아크고장 판단기법에 대한 연구)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.4
    • /
    • pp.260-265
    • /
    • 2008
  • The arc-fault occurring in the customer system becomes the direct cause of electric fire. However, it is very difficult to identify the arc-fault using the existing fault detection mechanism because the magnitude of the fault current is very small. Accordingly, this paper analyzes the causes of arc fault and designs the basic detection mechanism of arc fault. And then, it proposes an signal processing-based arc-fault determination methodology which can enhance the of accuracy of the arc-fault determination by applying DFT/DWT to the voltage and current waveform. Finally, this paper showed the application methodology of the proposed signal processing based fault determination method by applying and analyzing DFT/DWT to an high voltage in-rush current waveform.

  • PDF

AC Arc Detection Method using Mixed Filter and Frequency Analysis (혼합필터와 주파수분석기법을 이용한 교류 아크 검출 기법)

  • Jang, Dong-Uk;Park, Seong-Hee;Lee, Kang-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.200-205
    • /
    • 2017
  • In this paper, we propose a technique to determine the normal and arc of an alternating current using a mixed filter composed of an average filter and a band-pass filter and a frequency analysis. The proposed method uses the moving average filter of the FIR filter structure for noise removal and the band-pass filter of the IIR filter structure for detecting only specific frequency components after normalizing the measured current signal based on the maximum value. After performing Fast Fourier Transform (FFT) using the band-pass filtered signal, the total energy is calculated using the magnitude component of the frequency, and the arc is detected using the magnitude of the calculated energy. In order to show the validity of the proposed method, we experimented with various data and found that arc and steady state can be easily discriminated by calculating spectral energy. Therefore, it is considered that the proposed method can be applied to arc diagnosis of low voltage electric wire.

Detection of Series Arc Signal in Low-voltage Systems (저압계통에서 직렬아크신호의 검출)

  • Ji, Hong-Keun;Park, Chan-Yong;Kil, Gyung-Suk;Kim, Il-Kwon;Cho, Young-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.316-320
    • /
    • 2008
  • This paper described the design and fabrication of a series arc detection module to monitor electrical insulation in low-voltage system. The module consists of a passive high-pass filter with a low cut-off frequency of 3 kHz to attenuate power frequency voltage by 80 dB and an active band-pass filter with a frequency of 4 kHz to detect series arc signals only. For the application experiment, we simulated series arcing phenomena on various loads such as incandescent lamp controlled by dimmer and inverter fed induction motors by an arc generator specified in UL1699. From the experimental results, we could detect series arc signals without an influence of noises.

  • PDF

Detection of Series Arc Signal (직렬아크신호의 검출)

  • Ji, Hong-Keun;Park, Dae-Won;Kim, Il-Kwon;Kil, Gyung-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.225-229
    • /
    • 2008
  • This paper describes a series arc detection algorithm in a low-voltage wiring system. We designed and fabricated an arc detection circuit which consists of a high-pass filter with the low cut-off frequency of 3 kHz to attenuate power frequency. The series arcing phenomena was simulated by an arc generator specified in UL1699. In the experiment, various loads such as resistive loads, resistive loads controlled by a dimmer, and vacuum cleaners were used. Whether the signal is arc or noise is discriminated by pulse counts and periodicity of the detected signal.

  • PDF