• Title/Summary/Keyword: Arc pressure

Search Result 378, Processing Time 0.042 seconds

The Trial Manufacturing of Inner Bulb of 200W High Pressure Mercurry Lamps (고압수은램프발광관의 시작연구)

  • Chol Kon Chee
    • 전기의세계
    • /
    • v.19 no.2
    • /
    • pp.18-20
    • /
    • 1970
  • Research on the domestic production of arc tube of high pressure mercury lamp. This research is to solve the problem on the domestic manufacturing method for the arc tube of high pressure mercury lamp. (200W). The trial product is favorably compared with its foreign equivalents in its performances and quality. An advancement in manufacturing technology and the strict selection of raw materials will assure its domestification.

  • PDF

Analysis of Withstand Voltage between Arc Contacts of High Voltage SF6 Gas Circuit Breaker n Making Operation (초고압 SF6 가스 차단기 투입 시 아크접촉자 내전압 특성 연구)

  • Kim, In-Gil;Lee, Joo-Hyun;Jung, Hyung-Su;Park, Jae-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.4
    • /
    • pp.601-605
    • /
    • 2012
  • The non-controlled closing of High-voltage SF6 gas circuit breaker can cause transient current and overvoltage in the field. The controlled closing technology is an effective way to reduce transient current and voltage, prevent equipment failures, and improve power quality. For the development of controlled closing, it is obviously necessary to determine the withstand voltage between arc contacts of High-voltage SF6 gas circuit breaker in making operation. This paper focuses on decrease of pressure and density of SF6 gas that can affect withstand voltage between arc contacts in making operation. The dielectric strength between arc contacts could be improved by minimizing the decrement of pressure and density of SF6 gas obtained by simulation and test and moreover the rate of decrease of dielectric strength (RDDS) of arc contacts could be foreseen.

Effect of Chamber Pressure on the Microstructure of Fe Nano Powders Synthesized by Plasma Arc Discharge Process (플라즈마 아크 방전법으로 제조된 Fe 나노분말의 미세조직에 미치는 챔버압력 영향)

  • 박우영;윤철수;김성덕;유지훈;오영우;최철진
    • Journal of Powder Materials
    • /
    • v.11 no.4
    • /
    • pp.328-332
    • /
    • 2004
  • Fe nanopowders were successfully synthesized by plasma arc discharge (PAD) process using Fe rod. The influence of chamber pressure on the microstructure was investigated by means of X-ray Diffraction (XRD), Field Emission Scanning Electron Microscope (FE-SEM), Transmission Electron Microscopy (TEM) and X-ray Photoelectron Spectroscopy (XPS). The prepared particles had nearly spherical shapes and consisted of metallic cores (a-Fe) and oxide shells (Fe$_{3}$O$_{4}$), The powder size increased with increasing chamber pressure due to the higher dissolution and ejection rate of H$_2$ and gas density in the molten metal.

A Case Report of Quadriplegia Patients with Decubitus Ulcer (사지부전마비를 동반한 뇌경색 환자의 욕창 치험 1례)

  • Kim, Ki-tae;Jung, Jinhwa
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.19 no.3
    • /
    • pp.185-193
    • /
    • 2015
  • Objectives The purpose of this report is to represent decubitus ulcer(pressure sore) improved by carbon arc and oriental medicine. Methods Patients with decubitus ulcer were treated with carbon arc, acupuncture, herbal medicine and simple dressing. Laser was irradiated at ulcer site once a day for 5 hour, using cored carbon number 3000,3002. Simple dressing with wound cleansing was performed to prevent reinfection. Herbal medicine and acupuncture treatment were applied to improve patients' general condition. Ulcer sizes and aspects were carefully checked by one week. Results Sizes of the decubitus ulcer decreased. Stage of ulcer was improved from stage 3 to stage 2. These results show that carbon arc may play a role in treating the decubitus ulcer with oriental medicine.

Evaluation of the heat affection according to the gouging height for low alloy steel structures (가우징 높이에 따른 구조물의 열영향 평가)

  • Ha, Joon-Wook;Yang, Byong-Il;Park, Seong-Jin;Lee, Ki-Hak
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.477-482
    • /
    • 2001
  • A study was performed to determine the optimum height for an arc air gouging of temporary attachments, which were attached at the pressure vessel made of low alloy steel. Frequently, the crack occurred in the base metal by the excessive heat input during an arc air gouging process to remove the temporary attachments. A numerical analysis by 2-dimensional finite element method was performed to calculate the temperature distribution in the base metal during the removal of temporary attachments. And then the mock-up test was performed to verify the numerical results. Numerical values showed good agreement with the experimental results. These results indicated that the defects due to the excessive heat input during an arc air gouging were dependent on the height of temporary attachments remained above hie main products.

  • PDF

Calculation of Pressure Rise in a Thermal-expansion Type Arc Chamber (열팽창 분사식 가스차단부의 소호실내 압력상승 계산)

  • Choi, Y.K.;Oh, Y.H.;Shin, Y.J.;Park, K.Y.;Kim, H.J.;Choulkov, V.V.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.167-169
    • /
    • 1998
  • Recently $SF_6$ gas circuit breakers utilizing the thermal-expansion principle are increasingly used in distribution power system. Active researches and developments have been conducted to reduce the size and weight, and to improve the interrupting performance of the circuit breakers. It was first developed a programme which could show the hot gas flowing into the thermal-expansion arc chamber. This programme, using so-called FLIC method basically, adopted 'Simplified Enthalpy Arc Model' which was somewhat modified to estimate the arc quenching process. The computation by it was compared with the measured results of the pressure rise in the chamber, and both showed fairly good agreement.

  • PDF

Influence of processing parameters for adhesion strength of TiAlN films prepared by Arc Ion Plating

  • Ju, Yun-Gon;Fang, W.;Jo, Dong-Yul;Yun, Jae-Hong;Zhang, S.H.
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.136-137
    • /
    • 2007
  • Wear resistant TiAlN thin film has been widely deposited on the surface of cutting and forming tools by using Arc Ion Plating. TiAlN films are deposited by the processes designed by the Taguchi L18 experimental design. The L18 experimental design is applied to achieve surface properties and adhesion. The deposition parameters are working pressure, substrate temperature, bias voltage, arc power and pre-sputtering bias voltage and time. The most influential parameters on surface properties and adhesion are substrate bias voltage, working nitrogen pressure and arc power. The optimal coating processes are obtained for surface properties and adhesion.

  • PDF

The effect of reactive gases on the propertise of TiCN layer synthesized by Arc Ion plating process (Arc Ion Plating 방식에 의한 TiCN 증착시 반응가스가 코팅층에 미치는 영향)

  • Seo, Chang-Min;Kim, Chang-Geun;;Yu, Im-Jun
    • Journal of Ocean Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.56-68
    • /
    • 1997
  • This work was intended to study the effect of a partial pressure ratio and a total pressure of reactive gases on the properties of TiC$_{x}$N$_{1-x}$ . coated layer. In this regard, various TiC$_{x}$N$_{1-x}$ coatings were synthesized with C2112 and N2 Mixture gas of different compositions by Arc Ion Plating process which has been highlighted for an industrial purpose. It was revealed from colors and X-ray diffraction patterns that the concentration of carbon of a TiC$_{x}$N$_{1-x}$ coating increases with a partial pressure ratio (PC$_{2}$H$_{2}$/PN$_{2}$) as well as a total pressure Of $C_{2}$H$_{2}$ and N$_{2}$ mixture gas. Accordingly, the hardness of TiC$_{x}$N$_{1-x}$ coated layer increased but the adhesion to the substrate of SKH 51 was degraded. On the other hand, the deposition rate was independent of a partial pressure ratio and a total pressure of mixture gas. It was found that a uniform gas distribution is critical for an industrial application since the composition of a coating depends strongly on the location of a substrate inside of the furnace. As a result of milling tests with different TiC$_{x}$N$_{1-x}$ coated end mills, the one which has a low carbon concentration was better than others studied in this work.d in this work.

  • PDF

TRANSFORMER EXPLOSION AND FIRE PREVENTION (변압기 폭발/화재 방지 기술)

  • Kim, Hyung-Seung;Magnier, Philippe
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.93-94
    • /
    • 2007
  • An essential step for SERGI is to show the TRANSFORMER PROTECTOR (TP) efficacy for all transformers and all types of rupture of insulation. Its research program philosophy is thus to maintain a strong connection between experiments and the theoretical developments. Up to now, two TP test campaigns have been performed, both under the worst conditions by creating low impedance faults leading to electrical arcs inside the transformer tank dielectric oil. In 2002, Electricite de France performed 28 TP tests. Then, in 2004, a second campaign of 34 TP tests was carried out by CEPEL, the Brazilian independent High Voltage Laboratory. For the 62 tests, each transformer was equipped with the TP, which reacts directly to the moving dynamic pressure peak, shock wave, caused by the low impedance fault. When an electrical arc occurs, only one pressure peak is generated. The initial energy transfer is almost instantaneous, and so is the phase change. Because of the oil inertia, the gas is very quickly pressurised. As it is more difficult to vaporise a liquid than to crack oil-vapour into smaller molecules, the arc location would mainly remain in the gaseous phase after and less gas will be produced. As a result, when comparing tests for which pressure peaks are respectively equal to 8 bar (116 psi) and 8.8 bar (127 psi), the corresponding arc energies vary by an order 10 of magnitude (0.1 MJ and 1 MJ respectively). The correlation of the results obtained between arc energy and dynamic pressure demonstrates that the arc energy is not the key parameter during transformer tank explosion, which is in opposition with the common electrical engineers belief.

  • PDF

Study on the Measurement of Radiation Energy of the Arc in GCBs (가스차단기내 아크의 복사에너지 측정에 관한 연구)

  • Song, Ki-Dong;Oh, Yeon-Ho;Chong, Jin-Kyo;Cho, Young-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2122-2126
    • /
    • 2007
  • A special PM-Tube(Photo Multiplier Tube) that is using the photoelectric effect has been designed and manufactured to measure the radiation energy of arc in a gas circuit breaker(GCB). The PM-Tube, LLG(liquid light guides), ND(neutral density) filter, and a model gas circuit breaker have been combined for the reception and the transmission of the light and a simplified synthetic test facility with the arc energy measuring system has been established. In the case of $SF_6$ gas pressure $5kg.f/cm^2$ and arc length 20mm, the radiation energy increases with the arc current but it tend to be saturated in the above 20kA. Under the arc current 20kA, the total radiation energy has the biggest value around 8kA and was not exceeded 40% of the total arc energy.