• Title/Summary/Keyword: Arc of motion

Search Result 117, Processing Time 0.027 seconds

Sea-level Change and Coastal Erosion (해수면 변화와 해안 침식)

  • Jeon, Dong-Chull
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.4
    • /
    • pp.289-304
    • /
    • 1995
  • Time series of the relative sea levels at the selected tide-gauge stations in the North Pacific and historical aerial photographs in the Hawaiian Islands are analyzed. Long-term rising trend of sea level ranges from +1 to +5 mm/yr at most of the stations, which is primarily due to global warming and tectonic motion of the plates. The annual and interannual fluctuations of sea level result from the thermal expansion/contraction of sea-surface layer due to the annual change of the solar radiation and possibly from a coupled ocean-atmosphere phenomenon associated with an ENSO event, respectively. Sea-level changes in three different time-scales (linear trend. annual oscillation, and interannual fluctuation) and their quantitative contribution to the shoreline changes as a result of long-term cross-shore sediment transport arc hypothesized.

  • PDF

Experimental Study on Damping of Side-by-Side Moored Vessels (병렬계류된 선박의 감쇠력에 관한 실험연구)

  • KIM JIN-HA;HONG SA-YOUNG;KIM YOUNC-SIK;KIM DEOK-SU;KIM YOUNG-SU
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.160-165
    • /
    • 2004
  • Low-frequency damping characteristics of side-by-side moored LNG-FPSO and LNGC arc investigated through a series of free decay model tests in calm water and under wind load condition. It is shown that low frequency damping of LNGC changes dramatically, sway damping increases more than six times for 4m distance condition while it decreases by $30\%$ for 20m distance compared with a single LNGC case. Simulation using the experimental data enhances the results, which demonstrates the necessity of experimental low-frequency damping coefficients for simulation of side-by-side vessels motion behavior.

  • PDF

Post-buckling Behavior and Vibration Characteristics of Patched Reinforced Spherical Composite Panels (패치로 보강된 구형 복합재료 패널의 후좌굴 거동 및 진동 특성해석)

  • Lee, J.J.;Yeom, C.H.;Lee, I.
    • Composites Research
    • /
    • v.14 no.4
    • /
    • pp.27-34
    • /
    • 2001
  • The finite element method based on the total Lagrangian description of the motion and the Hellinger-Reissner principle with independent strain is applied to investigate the nonlinear behavior and vibration characteristics for patched reinforced laminated spherical panels. The patched elements are formulated using variable thickness at arbitrary point on the reference plane. The cylindrical arc-length method is adopted to obtain a nonlinear solution. The post-buckled vibration is assumed to be small amplitude. The effect of patch in the spherical shell Panel is investigated on the nonlinear response and the fundamental vibration characteristics. The present results show that the load-carrying capability can be improved by reinforcing patch. The fundamental frequency of patched panel is lower than that of equivalent shell panel. However, the fundamental frequency of patched panel does not decrease greatly due to the increase of nonlinear geometrical stiffness under loading.

  • PDF

A study on change in electric contact resistance of the tin-plated copper connector of automotive sensor due micro-vibration (차량용 주석 도금된 구리 커넥터에서 미세진동에 의한 전기접촉 저항변화에 관한 연구)

  • Yu, Hwan-Sin;Park, Hyung-Bae
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.6
    • /
    • pp.653-658
    • /
    • 2008
  • The automotive environment is particularly demanding on connector performance, and is characterized by large temperature changes, high humidity and corrosive atmospheres. Fretting is a contact damage process that occurs between two contact surfaces. Fretting corrosion refers to corrosion damage at the asperities of contact surfaces. This damage is induced under load and in the presence of repeated relative surface motion, as induced for example by vibration. This paper critically reviews the works published previously on fretting corrosion of electrical connectors. Various experimental approaches such as testing machines, material selection, testing environments, acceleration testing techniques and preventing methods are addressed. Future research prospects arc suggested.

  • PDF

An Investigation into Coordinated Control of 4-wheel Independent Brakes and Active Roll Control System for Vehicle Stability (차량 안정성 향상을 위한 ESC와 ARS의 통합 샤시 제어 알고리즘 개발)

  • Her, Hyundong;Yi, Kyongsu;Suh, Jeeyoon;Kim, Chongkap
    • Journal of Auto-vehicle Safety Association
    • /
    • v.5 no.1
    • /
    • pp.37-43
    • /
    • 2013
  • This paper describes an investigation into coordinated control of electronic stability control (ESC) and active roll control system (ARS). The coordinated control is suggested to improve the vehicle stability and agility features by yaw rate control. The proposed integrated chassis control algorithm consists of a supervisor, control algorithms, and a coordinator. The supervisor monitors the vehicle status and determines desired vehicle motions such as a desired yaw rate and desired roll motion based on control modes to improve vehicle stability. According to the corresponding the desired vehicle dynamics, the control algorithm calculated a desired yaw moment and desired roll moment, respectively. Based on the desired yaw moment and the desired roll moment, the coordinator determines the brake pressures and the ARC motor torques based on control strategies. Closed loop simulations with a driver-vehicle-controller system were conducted to investigate the performance of the proposed control strategy using CarSim vehicle dynamics software and the integrated controller coded using Matlab/Simulink.

Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon (직장풍선을 삽입한 전립선암 환자의 수술 후 방사선 치료 시 용적변조와 세기변조방사선치료계획 비교 평가)

  • Jung, hae youn;Seok, jin yong;Hong, joo wan;Chang, nam jun;Choi, byeong don;Park, jin hong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.45-52
    • /
    • 2015
  • Purpose : The dose distribution of organ at risk (OAR) and normal tissue is affected by treatment technique in postoperative radiation therapy for prostate cancer. The aim of this study was to compare dose distribution characteristic and to evaluate treatment efficiency by devising VMAT plans according to applying differed number of arc and IMRT plan for postoperative patient of prostate cancer radiation therapy using a rectal balloon. Materials and Methods : Ten patients who received postoperative prostate radiation therapy in our hospital were compared. CT images of patients who inserted rectal balloon were acquired with 3 mm thickness and 10 MV energy of HD120MLC equipped Truebeam STx (Varian, Palo Alto, USA) was applied by using Eclipse (Version 11.0, Varian, Palo Alto, USA). 1 Arc, 2 Arc VMAT plans and 7-field IMRT plan were devised for each patient and same values were applied for dose volume constraint and plan normalization. To evaluate these plans, PTV coverage, conformity index (CI) and homogeneity index (HI) were compared and $R_{50%}$ was calculated to assess low dose spillage as per treatment plan. $D_{25%}$ of rectum and bladder Dmean were compared on OAR. And to evaluate the treatment efficiency, total monitor units(MU) and delivery time were considered. Each assessed result was analyzed by average value of 10 patients. Additionally, portal dosimetry was carried out for accuracy verification of beam delivery. Results : There was no significant difference on PTV coverage and HI among 3 plans. Especially CI and $R_{50%}$ on 7F-IMRT were the highest as 1.230, 3.991 respectively(p=0.00). Rectum $D_{25%}$ was similar between 1A-VMAT and 2A-VMAT. But approximately 7% higher value was observed on 7F-IMRT compare to the others(p=0.02) and bladder Dmean were similar among the all plan(P>0.05). Total MU were 494.7, 479.7, 757.9 respectively(P=0.00) for 1A-VMAT, 2A-VMAT, 7F-IMRT and at the most on 7F-IMRT. The delivery time were 65.2sec, 133.1sec, 145.5sec respectively(p=0.00). The obvious shortest time was observed on 1A-VMAT. All plans indicated over 99.5%(p=0.00) of gamma pass rate (2 mm, 2%) in portal dosimetry quality assurance. Conclusion : As a result of study, postoperative prostate cancer radiation therapy for patient using a rectal balloon, there was no significant difference of PTV coverage but 1A-VMAT and 2A-VMAT were more efficient for dose reduction of normal tissue and OARs. Between VMAT plans. $R_{50%}$ and MU were little lower in 2A-VMAT but 1A-VMAT has the shortest delivery time. So it is regarded to be an effective plan and it can reduce intra-fractional motion of patient also.

  • PDF

The Kinematic Analysis of the Upper Extremity during Backhand Stroke in Squash (스쿼시 백핸드 드라이브 동작시 상지 분절의 운동학적 변인 분석)

  • An, Yong-Hwan;Ryu, Ji-Seon;Ryu, Ho-Young;Soo, Jae-Moo;Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.145-156
    • /
    • 2007
  • The purposes of this study were to investigate kinematic parameters of racket head and upper extremities during squash back hand stroke and to provide quantitative data to the players. Five Korean elite male players were used as subjects in this study. To find out the swing motion of the players, the land-markers were attached to the segments of upper limb and 3-D motion analysis was performed. Orientation angles were also computed for angular movement of each segment. The results were as follows. 1) the average time of the back hand swing (downswing + follow-through) was 0.39s (0.24 s + 0.15 s). 2) for each event, the average racket velocity at impact was 11.17m/s and the velocity at the end of swing was 8.03m/s, which was the fastest swing speed after impact. Also, for each phase, 5.10m/s was found in down swing but 7.68m/s was found in follow-through. Racket swing speed was fastest after the impact but the swing speed was reduced in the follow-through phase. 3) in records of average of joints angle, shoulder angle was defined as the relative angle to the body. 1.04rad was found at end of back swing, 1.75rad at impact and it changes to 2.35 rad at the end of swing. Elbow angle was defined as the relative angle of forearm to upper arm. 1.73rad was found at top of backswing, 2.79rad at impact, and the angle was changed to 2.55rad at end of swing. Wrist angle was defined as the relative angle of hand to forearm. 2.48rad was found at top of backswing, 2.86rad at impact, and the angle changes to 1.96rad at end of swing. As a result, if the ball is to fly in the fastest speed, the body has to move in the order of trunk, shoulder, elbow and wrist (from proximal segment to distal segment). Thus, the flexibility of the wrist can be very important factor to increase ball speed as the last action of strong impact. In conclusion, the movement in order of the shoulder, elbow and the wrist decided the racket head speed and the standard deviations were increased as the motion was transferred from proximal to the distal segment due to the personal difference of swing arc. In particular, the use of wrist (snap) may change the output dramatically. Therefore, it was concluded that the flexible wrist movement in squash was very important factor to determine the direction and spin of the ball.

Evaluation on Motion Features of the World's Second Archer during Back-Tension in Archery (양궁 백 텐션 국면에서 최우수 양궁선수의 동작특성 평가)

  • Yi, Jae-Hun;Hah, Chong-Ku;Ryu, Ji-Seon;Kim, Ki-Chan
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.197-207
    • /
    • 2007
  • It has been reported that Back-Tension played a significant role in archery (Lee & Bondit, 2005; Kim, 2007) but there are a few researches related Back-Tension in Korea recently. Therefore, the purpose of this study was to investigate archery back tension technique for the second ranked archer in the World and to find ways to improve performance. A subject(height: 185cm, mass: 82kg, years: 21yrs, careers: 12yrs) who is a number of national team and the second ranked archer in the World authorized by FITA (Federation Internationale de Trial Arc) was perticipated in this experiment. When shooting 60 shots($12{\times}5$), shooting motions were recorded with 7 infrared cameras and 2 ultrahigh-speed cameras. A QTM and an Auto Track were used to acquire raw data. The sampling rates of both cameras were 200 Hz. and 1000 Hz. respectively and data were filtered using a fourth order Butterworth low pass filtering with a cutoff-frequency of 30Hz. The parameters were calculated with Matlab6.5 and analyzed with SPSS11.0. After Pearson's correlations between 8 parameters were analyzed, 5 parameters from 13parameters that affected records were analyzed with multiple regression analysis (Enter order: x1, x2, x3, x4, x5). The results were as follows: 1. Comparing between parameters according to scores, the patterns of horizontal and vertical angular velocity(av.) of scapular relative angle was different between 8 score and 9 or 10 scores. 2. The correlations of parameters that affected records were a horizontal av.(x1, p=.032<.05) and a vertical av.(x3, p=.033<.05) of scapular from release to delivery in KB back-tension (anchoring-delivery). 3. The decision coefficients(R2) of above two parameters and three parameters selected by experts that may affect record, that is, an absolute trunk angle(x4) from in KKC back-tension (anchoring-release) and a horizontal relative scapular angle(x2) and an absolute trunk angle(x5) from release to delivery in KB back-tension were 7.7%(x1), 0.1%(x2), 8.5%(x3), 0.7%(x4) and 0.9%(x5) in sequence. 4. The multiple regression equation was a y= -1.16E-2 x1 + 0.109 x2 + 3.437E-2 x3 + 6.139E-2 x4 + 0.117 x5 + 3.420 In conclusion, a total contribution was low, that is, R2(17.9%) suggested that on the one hand, Lim's motion may not depend on a certain factor because his postural factors affected shooting motion are some stable on the other hand, unknown factors may exist(e.g. psychological, physiological factors etc.). Further study of EMG patterns of muscles and anatomic consideration related to shoulder girdle and scapular bones may help to identify mechanism of Back-Tension.

Pneumatic Separation on Separating Unit of a Combine Harvester (콤바인 선별실(選別室)의 기류선별(氣流選別)에 관한 연구(硏究))

  • Chung, C.J.;Nam, S.I.;Joo, B.C.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.3
    • /
    • pp.32-43
    • /
    • 1988
  • This study was attempted to investigate the pneumatic separation on separating unit of a combine harvester. The aerodynamic characteristics of threshed materials were analyzed by experiments. The air velocity distribution within the separation chamber was measured for various speeds of the winnower and suction fans to find out the operational and design conditions of the separating unit which would serve for reducing the grain loss from chaff outlet. The results of study arc summarized as follows: 1. Based on the separation curve of threshed materials analyzed, it was shown that three different kind. of materials-kernels, straw chaff, and leaf chaff were as a whole able to be separated pneumatically, regardless of varieties. However, a small amount of the separation grain loss may be expected to occur if the complete separation between kernels and straw chaff would be undertaken because some portion of their separation curve were overlapping. 2. The analysis of air velocity distribution showed that the separation chamber may be divided into two regions, the discharging and separating. The air velocity of the discharging region was 5-15 m/s and that of the separating region 2-5 m/s. 3. The air movement of the separation chamber may be a turbulence flow, being its speed became greater as it moves from the left to the right section of the separation chamber. The equi-speed line. of air flow had a steep gradient in between the discharging and the separation regions. The air velocity in the discharging region was much higher than the terminal velocity of kernels, because of which those kernels appearing in the region could be possibly exhausted as the grain loss from the chaff outlet. 4. The motion trajectory of threshed material in the separating region was dominantly affected by the winnower fan, on the other hand, its motion in the discharging region was affected by suction fan. 5. The grain loss from the chaff outlet was affected greatly by the winnower fan and the trace of kernel movement. It was observed that the optimum working speed to give minimum grain loss from chaff outlet for the combine tested should be maintained at 950~1,150 rpm for the winnower fan and 1,850 rpm for the suction fan. 6. It was shown that a large portion of grain loss from chaff outlet may occur when the kernels may bump against a portion of separation chamber wall and those kernels thus scattered into the discharging region were sucked by the suction fan. It was accordingly recommended that a new design of the wall of separation chamber so as to bump down kernels may be necessary to reduce grain loss from the chaff outlet.

  • PDF

Treatment Results of Capitellum Fractures (상완골 소두 골절의 치료결과)

  • Park, Jin-Soo;Chung, Yung-Khee;You, Jung-Han;Noh, Gyu-Cheol;Chung, Kook-Jin;Jung, Sung-Ook
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.2
    • /
    • pp.116-121
    • /
    • 2005
  • Purpose: Isolated capitellar fractures are rare, intra-articular fractures requiring an aggressive management regimen. Review the outcome after open reduction and internal fixation of the capitellar fractures. Materials and Methods: From 1998 to 2004, 4 patients with displaced fractures of the humeral capitellum were treated by open reduction and internal fixation of the capitellar fragments with cannulated screws. By use of the criteria of Bryan and Morrey et al, there were 3 type I fractures, 1 type III fracture. A lateral approach was used. The elbows were immobilized postoperatively for 4 to 28 days We evaluated the range of motion, stability, and pain using the criteria of Mayo score. Results: The follow-up period ranged from 12 to 36 months (mean, 15months). Three patients had a stable, pain-free elbow with good range of motion at follow-up. One patient with a neglected capitellar fracture have felxtion cpontracture of 40 degrees with 100 degrees of further felxion(total arc: 60) due to poor compliance to the postoperative rehabilitation. All fractures healed, and there was no evidence of avascular necrosis or degenerative change. Conclusion: Capitellar fractures, rare in case, gave a good result after open reduction and simple internal fixation with cannulated screws without any problem.

  • PDF