• Title/Summary/Keyword: Arc gap

검색결과 172건 처리시간 0.025초

아크 용접의 이면비드 예측 비교 (The Back-bead Prediction Comparison of Gas Metal Arc Welding)

  • 이정익;고병갑
    • 한국공작기계학회논문집
    • /
    • 제16권3호
    • /
    • pp.81-87
    • /
    • 2007
  • It is important to investigate the relationship between weld process parameters and weld bead geometry for adaptive arc robot welding. However, it is difficult to predict an exact back-bead owing to gap in process of butt welding. In this paper, the quantitative prediction system to specify the relationship external weld conditions and weld bead geometry was developed to get suitable back-bead in butt welding which is widely applied on industrial field. Multiple regression analysis and artificial neural network were used as the research methods. And, the results of two prediction methods were compared and analyzed.

고에너지 전자선 진자조사에 의한 선량분포 (The Dose Distribution of Arc therapy for High Energy Electron)

  • 추성실;김귀언;서창옥;박창윤
    • Radiation Oncology Journal
    • /
    • 제1권1호
    • /
    • pp.29-36
    • /
    • 1983
  • The treatment of tumors along curved surfaces with stationary electron beams using cone collimation may lead to non-uniform dose distributions due to a varying air gap between the cone surface and patient. For large tumors, more than one port may have to be used in irradiation of the chest wall, often leading to regions of high or low dose at the junction of the adjacent ports. Electron-beam arc therapy may elimination many of these fixed port problems. When treating breast tumors with electrons, the energy of the internal mammary port is usually higher than that of the chest wall port. Bolus is used to increase the skin dose or limit the range of the electrons. We invertiaged the effect of various arc beam parameters in the isodose distributions, and combined into a single arc port for adjacent fixed ports of different electron beam eneries. The higher fixed port energy would be used as the arc beam energy while the beam penetration in the lower energy region would be controlled by a proper thickness of bolus. We obtained the results of following: 1. It is more uniform dose distribution of electron to use rotation than stationary irradiation. 2. Increasing isocenter depth on arc irradiation, increased depth of maximum dose, reduction in surface dose and an increasing penetration of the linear portion of the curve. 3. The deeper penetration of the depth dose curve and higher X-ray background for the smaller field sized. 4. If the isocenter depth increase, the field effect is small. 5. The decreasing arc beam penetration with decreasing isocenter depth and the isocenter depth effect appears at a greater depth as the energy increases. 6. The addition of bolus produces a shift in the penetration that is the same for all depths leaving the shape of the curves unchanged. 7. Lead strips 5 mm thick were placed at both ends of the arc to produce a rapid dose drop-off.

  • PDF

조선용 강재의 $CO_2$레이저 GMA 하이브리드 용접에서 갭 브리징 능력 향상기술 개발 (Improvement of Gap Bridging Ability in $CO_2$ Laser-GMA Hybrid Welding)

  • 채현병;김철희;김정한;이세헌
    • Journal of Welding and Joining
    • /
    • 제24권5호
    • /
    • pp.49-56
    • /
    • 2006
  • For laser welding in shipbuilding industry, gap bridging capability is one of the most important characteristics to achieve the high productivity and good weld quality. Recently, laser-GMA hybrid welding process is regarded as a distinctive method to overcome the tight gap tolerance with improving the productivity. In this study, the influence of process parameters on the bead formation was experimentally analyzed and the relationship between the process parameters and geometric imperfections was investigated. It was revealed that undercut, excessive weld metal, excessive penetration and incompletely filled groove were the major geometric imperfections. The optimized wire feeding and arc pressure were necessary to ensure the gap bridging ability. The approach to select the process parameters was conducted for butt welding with up to 2mm joint gap, in which the sound weld beads were generated without changing the welding speed.

PTFE 노즐로부터 발생하는 용삭가스를 고려한 스위칭 아크 해석 (Numerical Analysis of Switching Arcs with the Ablation of PTFE Nozzles)

  • 이원호;김홍규;이종철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1536-1537
    • /
    • 2011
  • The high-voltage circuit breaker plays an important role in the electrical system because there has been a need for suitable switching devices capable of initiating and interrupting the flow of the electric fault current. It continues as the contacts recede from each other and as the newly created gap is bridged by a plasma. The arc plasma happens inside the insulation nozzle of SF6 self-blast interrupter which is newly developed as the next-generation switching principle. The ablation of PTFE nozzle is caused by this high temperature medium, the PTFE vapor from the nozzle surfaces flows toward the outlets and the pressure chamber. The vapor makes the pressure of the chamber increased by heat and mass transfer from the arcing zone. Because the rate of ablation depends on the magnitude of applied current, it decreases when the current goes to zero. The compressed gas inside the chamber flows reversely toward the arc plasma during this moment. According to this principle, the arc can be cooled down and the fault current can be interrupted successfully. In this study, we calculate arc plasmas and thermal-flow characteristics caused by fault current interruption inside a SF6 self-blast interrupter, and to investigate the effect of PTFE ablation on the whole arcing history.

  • PDF

Arc-Discharge로 합성한 SWNT의 전계방출 특성 (Field emission properties of SWNTs (single-walled nanotubes) synthesized by arc-discharge method)

  • 이현재;이양두;문승일;황호수;한종훈;유재은;남산;주병권
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 디스플레이 광소자분야
    • /
    • pp.185-188
    • /
    • 2004
  • A diode structure of field emission lamps based upon carbon-nanotube is studied. The single-walled carbon nanotubes(SWNTs) were produced by arc discharge method. We made the 1-inch diode type flat lamp using CNTs. We applied anode voltage gradually to refine the field emission behavior of emitter in dynamic vacuum system to study the emission current. the brightness and efficiency, etc. The field emission properties was estimated by varying gaps between the cathode and anode, contents of the glass frit. The good luminous efficiency is showed in the gap $900{\mu}m$, $1200{\mu}m$ and contents of the proper glass frit. For the upper conditions, the luminous efficiencies were respectively 23.30, 11.12 1m/W.

  • PDF

고장력강 용접부에 있어서 한계 COD값과 V charpy충격치와의 상관성에 관한 연구 (A study on the correlation between V charpy absorbed energy and critical COD value in the welded parts of high tensil strength steel under various welding methods)

  • 김영식;김충해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.57-67
    • /
    • 1988
  • Although handicapped by the inability to bridge the size gap between small laboratory sample and large engineering component, the V charpy test sample method does possess certain advantages, such as each of preparation, simplicity of test method, speed, low cost in test machinery, and low cost per test. On the other hand, the COD test method does posses advantages, which reduce the size gap between the laboratory sample and actual engineering component. Consequently, the correlation between V charpy absorbed energy and the critical COD value is required for estimating critical COD value from the simple V charpy test results. In this paper, the high tensile strength steel AH36 plate specimens having a single edge cracked notch were investigated to find out the correlation between V charpy absorbed energy and critical COD value in the welded parts under such various welding methods as shielded metal arc welding, the submerged arc welding and the electro gas welding by means of V charpy impact test and static 3-point bending test. Main results obtained are as follow ; 1. The relationships between V charpy absorbed energy Wc' and critical COD value ($\delta_c$)show; $\delta_c$=0.0065 Wc'+0.1906. 2. Ductile- brittle transition behaviours can be estimated by means of fracture appearance and general yielding behaviours. 3. The V charpy absorbed energy of SMAW is higher than that of SAW, EGW and similar relationships are obtained in the COD tests.

  • PDF

HID 램프용 점화기와 램프간 거리에 따른 점등 특성 분석 (Ignition Characteristics Analysis According to the Cable length Between the Ignition and Lamp)

  • 박종연;김기남
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.24-30
    • /
    • 2009
  • 본 논문에서는 HID 램프의 점등을 위한 3종의 점화기 비교 및 구동원리를 나타내었다. 또한 점화기와 램프사이의 케이블 길이에 따른 특성을 이론적 검증과 실험을 통하여 분석하였다. 점등전압은 점화기 구조와 케이블 길이 및 특성에 따라 달라지기 때문에 현장에서 많은 문제점을 안고 있다. 따라서 본 논문에서는 LC공진 타입의 점화기, Arc gap을 이용한 점화기, 주파수 가변을 동한 점화기를 대상으로 케이블 25[m] 거리에서 측정 및 분석하였다. 각각의 점화기 비교 및 케이블 특성을 분석하여 현장에서의 문제점을 해결할 방안을 제시하였다.

워터젯 플라즈마 스크러버 사불화탄소 분해 특성 (Decomposition Characteristics of Tetrafluoromethane Using a Waterjet Plasma Scrubber)

  • 임문섭;전영남
    • 한국기후변화학회지
    • /
    • 제8권1호
    • /
    • pp.63-71
    • /
    • 2017
  • It is recognized that tetrafluoromethane ($CF_4$) has a great influence on global warming. The $CF_4$ is known to have a large impact on climate change due to its large global warming index. In this study, a waterjet plasma scrubber (WPS) was designed and manufactured for the $CF_4$ decomposition. The WPS is a novel technology which is combined a gliding arc plasma and water injection at the center of the plasma discharge. This can give an innovative way for $CF_4$ decomposition by achieving larger plasma columnand generating OH radicals. A performance analysis was achieved for the design factors such as waterjet flow rate, total gas flow rate, consumption electric power, and electrode gap. The highest $CF_4$ decomposition and energy efficiencies were 64.8% and 6.43 g/kWh, respectively; Optimal operating conditions were 20 mL/min of waterjet flow rate, 200 L/min total gas flow rate, 5.3 kW consumption electric power, and 4.4 mm electrode gap. As for the 2 stage reactor of the WPS, the $CF_4$ decomposition efficiency improved as the 85.3% while the energy efficiency decreased as the 5.57 g/kWh.

교량용 후판 다층용접시 잔류응력과 변형에 미치는 루트간격의 영향 (Effects of Root Gap on Residual Stresses and Deformation in the Multi-Pass Weld of Thick Plates for Steel Bridge)

  • 장경복;김하근;강성수
    • Journal of Welding and Joining
    • /
    • 제17권1호
    • /
    • pp.88-96
    • /
    • 1999
  • The effects of root gap on welding residual stress and deformation are dealt with the multi-pass weldment with three kinds(0, 6, 30mm) of root gap by F.E.M common code, and then compared with experiment data. In this analysis, an 100% ramp heat input model was used to avoid numerical convergence problem due to an instantaneous increase in temperature near the fusion zone, and the effect of a moving arc in a two dimensional plane was also included. During the analysis, a small time increment was applied in a period with instantaneous temperature fluctuation while a large time increment was used in the rest period. The residual stress is distributed as symmetric types and maximum value is also equivalent when the weldment with 0mm and 6mm root gap is welded. In the case of 30mm root gap welding, the distribution of the residual stress extends over a wide range as asymmetric types due to the built-up weld, and most of the residual stress is biased in the side of a built-up weld part. In case of 0mm gap welding and 6mm gap welding, a little angular distortion occurs, but the level of deformation is small. When the weldment with 30mm root gap is welded, the angular deformation of the asymmetric types, however, occurs larger than the other specimens. The experimental and the analytic results show good coincidence and indicate that the welding residual stress and deformation distribution of 30 mm root gap specimen may be asymmetric and the amplitude is larger than those of root gap specimen under standard.

  • PDF

3차원 유한요소법에 의한 진공 인터럽터의 전계해석 (An Electric Field analysis of a Vacuum Interrupter by 3 Dimensional Finite Element Method)

  • 최승길;심재학;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.913-915
    • /
    • 1998
  • This paper describes the application of two and three dimensional electric field analysis for vacuum interrupter with spiral contacts. The electric potentials of floating arc shield and electric fields in a vacuum interrupter are analysed at various gap distances from 1mm to 12mm. The electric potentials of floating shield is increased with the gap distance, which is because the relative position of shield is closer to the fixed contact so that the capacitance distribution inside interrupter is varied. The calculated results show that the maximum value of electric field in a vacuum interrupter with floating shield is nearly same to that without shield at short gap distance below 5mm, however at longer gaps more intensive electric field is achieved in interrupter with shield comparing with the model without shield, which is due to the influence of charged floating shield.

  • PDF