• Title/Summary/Keyword: Aqueous Cleaning Solution

Search Result 37, Processing Time 0.02 seconds

Effect of 20 % EDTA Aqueous Solution on Defective Tubes (Alloy600) in High Temperature Chemical Cleaning Environments (고온화학세정환경에서 20 % EDTA 용액이 결함 전열관 (Alloy600)에 미치는 영향)

  • Kwon, Hyuk-chul
    • Corrosion Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.84-91
    • /
    • 2016
  • The transport and deposition of corrosion products in pressurized water nuclear reactor (PWR) steam generators have led to corrosion (SCC, denting etc.) problems. Lancing, mechanical cleaning and chemical cleaning have been used to reduce these problems. The methods of lancing and mechanical cleaning have limitations in removing corrosion products due to the structure of steam generator tubes. But high temperature chemical cleaning (HTCC) with EDTA is the most effective method to remove corrosion products regardless of the structure. However, EDTA in chemical cleaning aqueous solution and chemical cleaning environments affects the integrity of materials used in steam generators. The nuclear power plants have to perform the pre-test (also called as qualification test (QT)) that confirms the effect on the integrity of materials after HTCC. This is one of the series studies that assess the effect, and this study determines the effects of 20 % EDTA aqueous solution on defective tubes in high temperature chemical cleaning environments. The depth and magnitude of defects in steam generator (SG) tubes were measured by eddy current test (ECT) signals. Surface analysis and magnitude of defects were performed by using SEM/EDS. Corrosion rate was assessed by weight loss of specimens. The ECT signals (potential and depth %) of defective tubes increased marginally. But the lengths of defects, oxides on the surface and weights of specimens did not change. The average corrosion rate of standard corrosion specimens was negligible. But the surfaces on specimens showed traces of etching. The depth of etching showed a range on the nanometer. After comprehensive evaluation of all the results, it is concluded that 20 % EDTA aqueous solution in high temperature chemical cleaning environments does not have a negative effect on defective tubes.

Analysis of Monitoring and Recycling Technology Technologies of Cleaning Solution and Rinse Water in the Aqeous Cleaning System (수계 세정시스템의 세정액/헹굼수의 모니터링 및 재활용 기술 분석)

  • Han, Sang-Won;Lee, Ho Yeoul;Bae, Jae-Heum;Ryu, Jong-Hoon;Park, Byeong-Deog;Jeon, Sung-Duk
    • Clean Technology
    • /
    • v.7 no.4
    • /
    • pp.225-242
    • /
    • 2001
  • Cleaning process is necessary for machining parts or manufacturing finished products in the industry. Most of domestic and foreign companies are now trying to adopt environment-friendly aqueous cleaning agents instead of CFC-113 and 1,1,1-TCE which are ozone-depleting substances. However, the aqueous cleaning system has a disadvantage due to its generation of lots of waste water since the system utilizes water in cleaning and rinsing processes. Thus, it is very important that monitoring and recycling technologies of the cleaning solution and the rinse water should be introduced in the aqueous cleaning system in order to minimize generation of waste water and to maintain its cleaning performance for a quite long time. In this paper, the cleaning agents utilized in the aqueous cleaning system and cutting oils which are main contaminants were examined and analyzed. And the monitoring and recycling technologies of the aqueous cleaning system which can be employed in the industrial fields were also reviewed and evaluated.

  • PDF

Evaluation of Cleaning Ability of Aqueous Cleaning Agents according to their Additives (수계세정제의 첨가제에 따른 세정성 평가연구)

  • Kim, Hansung;Bae, Jae Heum
    • Clean Technology
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2006
  • Aqueous cleaning agents which are considered to be environmental-friendly and promising alternative ones among various industrial cleaning agents were evaluated in this words. In order to formulate aqueous cleaning agents, primary alcohol ethoxylates with 3, 5 and 7 moles of ethylene oxides among nonionic surfactants were selected as main surfactants. And anionic surfactants and alcohols were chosen as their cosurfactants. Builders such as NaOH, KOH, $Na_2CO_3$ and $NaHCO_3$ were also evaluated as additives for improvement of cleaning efficiency of aqueous cleaning agents. The experimental results of cleaning ability tests show that introduction of anionic surfactant TLS as cosurfactant in alcohol ethoxylate-based aqueous solution gives the best cleaning efficiency for removing mixed soil of cutting oil and grease. NaOH and $Na_2CO_3$ are also shown to play an important role for improvement of cleaning efficiency in a aqueous cleaning agent.

  • PDF

A Study on Laboratory Treatment of Metalworking Wastewater Using Ultrafiltration Membrane System and Its Field Application (한외여과막시스템을 이용한 금속가공폐수의 실험실적 처리 및 현장 적용 연구)

  • Bae, Jae Heum;Hwang, In-Gook;Jeon, Sung Duk
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.487-494
    • /
    • 2005
  • Nowadays a large amount of wastewater containing metal working fluids and cleaning agents is generated during the cleaning process of parts working in various industries of automobile, machine and metal, and electronics etc. In this study, aqueous or semi-aqueous cleaning wastewater contaminated with soluble or nonsoluble oils was treated using ultrafiltration system. And the membrane permeability flux and performance of oil-water separation (or COD removal efficiency) of the ultrafiltration system employing PAN as its membrane material were measured at various operating conditions with change of membrane pore sizes and soil concentrations of wastewater and examined their suitability for wastewater treatment contaminated with soluble or insoluble oil. As a result, in case of wastewater contaminated with soluble oil and aqueous or semi-aqueous cleaning agent, the membrane permeability increased rapidly even though COD removal efficiency was almost constant as 90 or 95% as the membrane pore size increased from 10 kDa to 100 kDa. However, in case of the wastewater contaminated with nonsoluble oil and aqueous or semi-aqueous cleaning agent, as the membrane pore size increased from 10 kDa to 100 kDa and the soil concentration of wastewater increased, the membrane permeability was reduced rapidly while COD removal efficiency was almost constant. These phenomena explain that since the membrane material is hydrophilic PAN material, it blocks nonsoluble oil and reduces membrane permeability. Thus, it can be concluded that the aqueous or semi-aqueous cleaning solution contaminated with soluble oil can be treated by ultrafiltration system with the membrane of PAN material and its pore size of 100 kDa. Based on these basic experimental results, a pilot plant facility of ultrafiltration system with PAN material and 100 kDa pore size was designed, installed and operated in order to treat and recycle alkaline cleaning solution contaminated with deep drawing oil. As a result of its field application, the ultrafiltration system was able to separate aqueous cleaning solution and soluble oil effectively, and recycle them. Further more, it can increase life span of aqueous cleaning solution 12 times compared with the previous process.

The Simultaneous absorption of SOX-NOX using aqueous ammonia solution (암모니아수용액을 이용한 SOX-NOX 동시 흡수에 관한 연구)

  • Kim, Jae-Gang;Lee, Ju-Yeol;Park, Byung-Hyun;Choi, Jin-Sik
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.372-376
    • /
    • 2015
  • The experiment was performed using the cleaning precipitator To investigate the absorption efficiency of the $SO_X/NO_X$ of the aqueous ammonia solution. Concentration of the cleaning liquid is 0.1, 0.5, and 1.0% with increasing absorption efficiency has improved. However, the reaction shown only a difference in time. Absorption efficiency has improved in accordance with the gas residence time. When the direction of the same gas and the cleaning liquid is determined that there is the effect of increasing the residence time. The relative impact of $SO_X$ and $NO_X$ is this likely to react slower than $SO_X/NO_X$. The yield is determined to require adjustment of the cleaning dust collector according to the concentration of the next gas.

Characteristics of Semi-Aqueous Cleaning Solution with Carboxylic Acid for the Removal of Copper Oxides Residues (산화구리 잔유물 제거를 위한 카르복시산 함유 반수계 용액의 세정특성)

  • Ko, Cheonkwang;Lee, Won Gyu
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.548-554
    • /
    • 2016
  • In this study, semi-aqueous solutions containing carboxylic acids such as oxalic acid (OA), lactic acid (LA) and citric acid (CA) were formulated for the removal of copper etching residues produced at the interconnection process, and their characteristics were analyzed. Carboxylic acids in the solutions were apt to form various copper complexes according to the value of pH. Semi-aqueous solution containing 10 wt% CA showed the lowest etching rate of copper in the range from pH2 to pH7 and the highest selectivity in the range of pH 2 to pH 4. However, the cleaning solution containing 10 wt% LA revealed the superior selectivity at the range from pH 5 to pH 7. Appropriate selection of carboxylic acid should be required to improve the performance of cleaning solution. In the case of CA, the etching selectivity of copper oxide complex to copper was increased with the concentration of CA in the solution, when the solutions contain over 5 wt% CA, the copper interconnection layer has a metallic copper surface more than 88% in the area. The result shows that CA contained semi-aqueous solution has a relatively good cleaning ability.

Cleaning Behavior of Aqueous Solution Containing Amine or Carboxylic Acid in Cu-interconnection Process (아민과 카르복실산이 함유된 수계용액의 구리 배선 공정의 세정특성)

  • Ko, Cheonkwang;Lee, Won Gyu
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.632-638
    • /
    • 2021
  • With the copper interconnection in the semiconductor process, complex residues including copper oxide, fluoride, and polymeric fluorocarbon are formed by plasma etching. In this study, a cleaning solution was prepared with a component having an amine group (-NH2) and a carboxyl group (-COOH), and the characteristics of removing post-etch residues in the copper wiring process were analyzed. In the cleaning solution containing an amine group, the length of the component substituted with nitrogen and the length of the carbon chain influenced the cleaning effect, and the etching rate of copper oxide increased as the pH of the cleaning solution increased. The activity of the amine group is in the basic region, and the activity of the carboxyl group is in the acidic region, and the cleaning process proceeds through complex formation with copper or copper oxide in each region.

A Study on Formulation of Surfactant-free Aqueous Cleaning agents and Evaluation of Their Physical Properties and Cleaning Ability (계면활성제 무첨가 세정제의 배합 및 물성/세정성 평가 연구)

  • Lee, Jae Ryoung;Yoon, Hee Keun;Lee, Min Jae;Bae, Jae Heum;Bae, Soo Jeong;Lee, Ho Yeoul;Kim, Jong Hee
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.219-225
    • /
    • 2013
  • Environment-friendly and surfactant-free aqueous cleaning agents have been developed in order to solve various problems generated by surfactants in the aqueous cleaning agents. Aqueous surfactant-free cleaning agents, S-1 and S-2 have been formulated with water-soluble solvents such as propylene glycol and propylene glycol ether on their main components and with some additives. These solvents were chosen because of their good solubility in water and excellent solubility of fluxes which are major contaminants of printed circuit board in the electronic industry. Physical properties of the formulated and the imported cleaning agents were measured to predict their cleaning performance, and their cleaning abilities of flux and solder contaminants were evaluated under the various ultrasonic frequencies by a gravimetric method. The measurement results show that the physical properties of cleaning agent V are generally similar with those of formulated cleaning agents S-1 and S-2. Both the cleaning agent V and the formulated cleaning agents S-1 and S-2 showed similar trends that their pH decrease in the beginning and then increases later on with the increase of their dilution in water. It is considered that the wetting indices of the cleaning agents calculated with experimental values do not not have any influence on their cleaning ability. In ultrasonic cleaning tests under three ultrasonic frequencies of 28, 45, and 100 kHz, their best performances of cleaning solder and flux were obtained at 45 kHz and 28 kHz, respectively, and the cleaning performance of the formulated cleaning agents S-1 and S-2 was better than that of the cleaning agent V. However, in the case of the recommended diluted concentration of 25 wt% cleaning solution, the cleaning performance of the cleaner V for solder and flux was better in the initial stage of cleaning compared to the formulated cleaners. And it may be concluded that the formulated cleaning agents S-1 and S-2 can be applied to cleaning of solder and flux in the industry, based on the experimental results in this study.

Durable Water and Oil Repellent Finish of Wool Fabric(II) (양모직물의 내구성 발수 및 발유가공(II))

  • 나도춘;정순량;박병기;정경락
    • Textile Coloration and Finishing
    • /
    • v.10 no.4
    • /
    • pp.1-6
    • /
    • 1998
  • It is important in the durable water and oil repellent finishing for wool fabric what kinds of water-repellent agents will be used. Water repellent agents and its concentration were aleady chosen in the previous paper, one of the crosslinking agents which has less damages(harsh handle or yellowing) to the treated fabrics was a low molecular weight urethane-based resins(eg. Elastron BN-11). In repellent finishing, fabrics were padded in a bath which contained aqueous solution of water-repellent agents, and crosslinking agents, and wetting agents, followed by drying and curing. The most suitable treating condition for excellent repellency and durability to dry-cleaning was as follows : Fabrics are padded at liquor pick-up ratio of 50%, with aqueous solution which contained $30g/\ell$ of water-repellent agents, and $1g/\ell$ of crosslinking agents, and 40g/s of wetting agents. And the padded fabrics were dried at $110^\circ{C}$ for 1 minute, and cured at $160^\circ{C}$ for 1 minute. For the fabrics, water and oil repellencies and durability to repeated dry-cleanings were observed. For enhancing the durability to dry-cleaning, the role of crosslinking agents was important for they bonds water-repellent agents and fibers to 3-dimensional net structure. Therefore, the most suitable drying and curing conditions should be selected according to the kinds of crosslinking agents.

  • PDF

Disinfection of Water by Ultrasonic Irradiation (초음파 검사에 의한 수중의 살균처리)

  • 손종렬;유병성
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.1
    • /
    • pp.54-61
    • /
    • 1999
  • The industrial techniques of ultrasound have been used in the various fields, such as cleaning, medical surgery, emulsification, cell disruption etc. Especially the application of cell disruption was interested in the field of disinfection process in water by ultrasonic irradiation. It has been recognized that the ultrasounds are irradiated in aqueous solution, cavitation bubbles are generated and shock waves of high temperature and pressure are emitted as the bubbles are developed and finally broken, which function as a energy source to promote reaction efficiencies of various kinds of chemical reactions such as disinfection reaction in water. Therefore, this study was performed to apply the ultrasound for the disinfection method of infected drinking raw water and to discuss the limiting factors such as pH, sample volume and reaction temperature influenced on the removal efficiency of E. coli from experimental analysis of the results obtained in bench-scale plant. For the experiments to measure the influence of reaction parameters in the ultrasonic disinfection process, escalated reactivity of aqueous solutions was excellent when pH in aqueous solution was low, and sample volume was small. On the contrary, the reactivity of disinfection became elevated when reaction temperature was high. It was found that the rate constant of disinfection reaction was applied by Chick's law, reaction kinetics of Chick's law was irreversible and pseudo-first order at all the tested conditions.As a conclusion it appeared that the technology using ultrasonic irradiation can be applied to the treatment of disinfection in infected water which are difficult to be treated by conventional methods.

  • PDF