• Title/Summary/Keyword: Application Generator

Search Result 753, Processing Time 0.029 seconds

Research on the Process of Constructing Application Systems Using the E-R Model and an Automated Application Generator (E-R 모델과 자동생성기를 이용한 응용시스템의 구축 과정에 관한 연구)

  • Chung, Il-Choo
    • Journal of Information Technology Applications and Management
    • /
    • v.12 no.4
    • /
    • pp.133-155
    • /
    • 2005
  • This Paper makes an attempt to suggest a process of automatically generating application software based on the Entity-Relationship model 1. The designer develops an E-R model of an real-world system. 2. The designer inputs the entity and relationship types, and attributes shown in the E-R model, and also the basic operations of the application system to the software generator. 3. The application generator produces database schema and link information between application programs, and then automatically generates a stereo-type application system. In order for the automated application generator to build the application system in a systematic way, four basic program generation rules have been suggested. A set of computer programs have been developed in order to show the applicability of the automated software generation process suggested in this paper. By following each rule with the generator, the designer can build an application in an efficient manner compared with traditional (manual programming) approaches. It has been demonstrated from the case study that the idea of applying an automated generator in systems development based upon the E-R model is feasible.

  • PDF

Application Case of ISO 22266-1 for Establishing the Torsional Vibration Criteria of a Nuclear Turbine Generator (원전 터빈 발전기 비틀림 진동기준 국제표준규격(ISO 22266-1) 적용 사례)

  • Chung, Hyuk-Jin;Song, Woo-Sok;Lee, Hyuk-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.225-226
    • /
    • 2010
  • ISO 22266-1 issued in May 2009 provides guidelines for applying shaft torsional vibration criteria, under normal operating conditions, for the coupled shaft system and long blades of a turbine generator set. In case that a turbine generator vendor do not meet the separation margin of torsional natural frequencies in the technical specifications of the purchaser, this standard can present the reasonable and objective criteria about torsional vibration which both purchaser and supplier can agree on, while ensuring the integrity of turbine generator. This paper describes the application case of ISO 22266-1 for the establishment of torsinal vibration criteria under retrofitting the turbine generator of 'U' nuclear power plant.

  • PDF

Analysis of HGAX Cycle for Reducing the Generator Temperature and Enhancing the Hot-Water Temperature (발생기 온도저감 및 고온열수 획득을 위한 Hybrid GAX 사이클 해석)

  • 강용태;윤희정;조현철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.2
    • /
    • pp.127-133
    • /
    • 2002
  • The objectives of this paper are to develop an advanced GAX cycle named HGAX (Hybrid Generator Absorber heat exchanger) cycle, and to study the effect of key parameters on the cycle performance and the hot-water temperature from the condenser. New types of the HGAX cycle are developed by adding a compressor between the generator and the condenser- Type C (performance improvement and reduction of the generator temperature) and Type D (Hot-water temperature application). The solution temperature in the generator outlet is reduced to 168$^{\circ}C$ with the COP improvement of 19% compared to the standard GAX cycle. The hot-water temperature from the condenser is raised to 106$^{\circ}C$ for panel heating (Ondol heating) application.

Design of A Push Content Generator for Push Service in Wireless Application Protocol (WAP기반 Push 서비스를 위한 Push Content Generator 설계)

  • 이정은;박병화;신동일;신동규
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2000.10c
    • /
    • pp.132-134
    • /
    • 2000
  • 무선 인터넷의 급속한 발전과 더불어 모바일 인터넷에서 요구되는 기능이 점점 다양화되어 가고 있다. 특히 WAP)Wireless Application Protocol)상에서 지원되는 Push 서비스의 요구가 늘어나고 있다. 본 논문에서는 WAP상에서 사용하는 Push message의 보다 쉬운 구현을 위해 Push 서비스의 구조와 동작 원리를 이해하고 Push Content Generator의 설계에 대해 기술한다.

  • PDF

Automated Generation of Software Systems in Systems Construction (시스템 구축 과정에서 소프트웨어 자동생성 도구의 적용)

  • 정일주
    • Journal of Information Technology Application
    • /
    • v.3 no.4
    • /
    • pp.63-92
    • /
    • 2001
  • This paper makes an attempt to look at the process of automatically generating an application software system based on the Entity-Relationship (E-R) model. Basically, the process consists of five steps as follows: First, the designer develops an E-R model of an real-world system. Second, the software generator automatically generates a stereo-type application system. Third, the generator produces database schema and link information between application programs. Fourth, the designer designs the user interface including menu, screen design and so on. Finally, the generator completes the process integrating all the elements of an application system. Five basic program generation rules, three extended rules and a database generation rule have been suggested. By following each rule with the generator, the designer can build an application with an extremely efficient manner compared with traditional approaches. A case study has been included in order to show the applicability of the automated software generation process suggested in this paper. It has been demonstrated from the case study that the idea of applying an automated generator in systems development based upon the E-R model worked well.

  • PDF

Application of Wavelet Transform for Fault Discriminant of Generator (발전기의 고장 판별을 위한 웨이브릿 변환의 적용)

  • Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.1
    • /
    • pp.35-40
    • /
    • 2015
  • Generators are the most complex and expensive single element in a power system. The generator protection relays should to minimize damage during fault states and must be designed for maximum reliability. A conventional CDR(Current Differential Relaying) technique based on DFT(Discrete Fourier Transform) filter have the disadvantages that the time information can lead to loss in the process of converting the signal from the time domain to the frequency domain. A WT(Wavelet transform) and WT analysis is known that it is possible with the local analysis of the fault and transient signal. In this paper, to overcome the defects in the DFT process, an application of WT for fault detection of generator is presented. This paper describes an selection of mother Wavelet to detect faults of generator. Using collected data from the fault simulation with ATPdraw, we analyzed the several mother Wavelet through the course of MLD(multi-level decomposition) using MATLAB software. Finally, it can be seen that the proposed technique using detail coefficient of Daubechies level 2 which can be fault discriminant of generator.

Behaviour Analysis of Self Excited Induction Generator Feeding Linear and No Linear Loads

  • Moulahoum, Samir;Kabache, Nadir
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1371-1379
    • /
    • 2013
  • Application of induction machines in wind turbine driven generators is a good alternative due to their good characteristics such as efficiency, reliability and low cost. Nevertheless, when isolated operation is required, the application of external capacitive bank, connected to the stator windings, to provide self-excitation results in a rather complex analysis. This paper presents an analysis of self-excited induction generator connected to a load either directly or by an intermediate of a power converter. At first a dynamic model of the induction generator accounting for magnetic saturation is developed. Then a number of balanced and unbalanced capacitors, passive and active loads are verified. Experimental results obtained from laboratory tests are compared to those simulated; the two are shown to be in good agreement.

Application of Vortex Generators on Smart Un-manned Aerial Vehicle(SUAV) (스마트 무인기에 부착한 Vortex Generator 효과)

  • Chung, Jin-Deog;Choi, Sung-Wook;Cho, Tae-Whan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.8
    • /
    • pp.688-693
    • /
    • 2007
  • To improve aerodynamic efficiency of the Smart Un-manned Aerial Vehicle(SUAV), vortex generator was applied along the wing upper surface during SUAV tests. Vortex generator, initially used in TR-S2 configuration to enhance lift characteristic, increased lift coefficient. Meanwhile vortex generator produced excessive drag and eventually reduced lift-to-drag ratio. To examine the effect of vortex generator's height, three different heights of vortex generator were used for various SUAV configuration. Vortex generator of 3mm height used in TR-S4 configuration produced 3.1% increase in maximum lift coefficient and 1.5% reduction in lift-to-drag ratio.

Application Analysis for Loss of Excitation Relay of Generator Protection (발전기 보호용 계자상실 계전기의 적용 분석)

  • Oh, Yong-Taek;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.322-326
    • /
    • 2014
  • Recently, the LOE(loss of excitation) incidents are occurred in domestic synchronous generator frequently, the synchronous generator protection system has been much attention for the LOE protection of the incidents that threats synchronous generators and power systems. This paper was showed the characteristics and practices of distance relay that widely used LOE protection relaying in generator. Firstly, the operating characteristics and the impedance locus for LOE of the generator protection were introduced. Even if the conventional simulation program is used for modeling, but it is difficult to implement a LOE modeling and simulation of synchronous generator. So, the LOE relay operation data collected from thermal power plant and nuclear power plant in real fields were analyzed. By reviewing the applications of GE Mho relays, the reliability of LOE for synchronous generator protection in domestic were improved.

An Application of Harmony Search Algorithm for Operational Cost Minimization of MicroGrid System (마이크로 그리드 운영비용 최소화를 위한 Harmony Search 알고리즘 응용)

  • Rhee, Sang-Bong;Kim, Kyu-Ho;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.7
    • /
    • pp.1287-1293
    • /
    • 2009
  • This paper presents an application of Harmony Search (HM) meta-heuristic optimization algorithm for optimal operation of microgrid system. The microgrid system considered in this paper consists of a wind turbine, a diesel generator, and a fuel cell. An one day load profile which divided 20 minute data and wind resource for wind turbine generator were used for the study. In optimization, the HS algorithm is used for solving the problem of microgrid system operation which a various generation resources are available to meet the customer load demand with minimum operating cost. The application of HS algorithm to optimal operation of microgrid proves its effectiveness to determine optimally the generating resources without any differences of load mismatch and having its nature of fast convergency time as compared to other optimization method.