• 제목/요약/키워드: Apparatus Capacity

검색결과 175건 처리시간 0.023초

태양에너지 해수담수화를 위한 3중 효용 증발식 담수기 개발 (Development of 3th Effects Evaporative desalination system for Solar Desalination System)

  • 황인선;주홍진;윤응상;곽희열
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.201-201
    • /
    • 2010
  • The evaporative desalination system with solar energy would be the efficient and attractive method to get fresh water. This study was described the development of Multi Effect Distillation(MED) with solar energy desalination system. The system was designed and manufactured Multi effect distillation on the capacity of $3m^3$/day. The experimental apparatus consists mainly of ejector pump, Hot water pump, flow meter, demister, cooler, evaporator and condenser. Evaporator and condenser were made Shell&Tube Heat Exchanger type with corrugated tube. The experimental variables were chosen $75^{\circ}C$ for hot water inlet temperature, 40, 60 and $80{\ell}$/min for hot water inlet volume flow rate, 6.0 and $8.0{\ell}$/min for evaporator feed seawater flow rate, $18^{\circ}C$ for sea water inlet temperature to cover the average sea water temperature and the salinity of sea water is measured about 33,000 PPM (parts per million). for a year in Korea. This study was analyzed the results of thermal performance of Multi Effect Distillation. The results are as follows, The experimental Multi effect distillation is required about 40 kW heat source for production of $3m^3$/day fresh water. Various operating flow rate was confirm in the experiments to get the optimum design data and the results showed that the optimum total flow was $8.0{\ell}$/min. Comparison of Single Effect Distillation with Multi Effect Distillation showed MED is at least more than double of SED.

  • PDF

강화노반 쇄석재료의 전단강도특성을 고려한 영구변형예측모델 개발 (Development of Permanent Deformation Prediction Model for Trackbed Foundation Materials based on Shear Strength Parameters)

  • 임유진;황정규;조호진
    • 한국철도학회논문집
    • /
    • 제15권6호
    • /
    • pp.623-630
    • /
    • 2012
  • 궤도하부층의 지지강성을 확보하기 위하여 설치하는 강화노반은 통상 일정 입도분포의 쇄석재료로 구성된다. 이러한 강화노반은 통과톤수의 누증 즉, 과도한 열차하중이 반복적으로 가해질 경우 영구변형이 발생할 수 있으며 이러한 영구변형은 궤도틀림의 한 원인이 될 수 있다. 또한 강화노반 재료의 적정두께를 확정하기 위해서는 이러한 영구변형 특성을 파악하는 것이 중요하다. 본 연구에서는 국내 강화노반 재료로 사용될 가능성이 높은 M-40 쇄석재료를 선정하여 대형반복삼축시험을 실시하여 재료의 회복탄성 특성과 영구변형 특성을 분석하였다. 시험으로부터 임의 전단응력비 및 반복재하횟수에 따른 회복탄성계수 특성과 영구변형 발생특성을 분석하였으며 M-40 쇄석강화노반 재료의 영구변형에 영향을 미치는 인자(반복재하횟수, 구속압, 전단응력비, 탄성계수 등)를 함께 고려할 수 있는 영구변형 예측모델을 제시하였다.

인장시험(引張試驗)에 의한 보강토(補强土)의 거동결정(擧動決定) (Soil-Reinforcement Interaction Determined by Extension Test)

  • 김운영
    • 대한토목학회논문집
    • /
    • 제8권1호
    • /
    • pp.33-40
    • /
    • 1988
  • 흙과 보강재 사이의 거동을 측정하는 수단으로서 hollow cylinder type의 샘플 내에 보강재를 인장방향으로 삽입하여 주위압력을 일정하게 유지한 가운데 축력(軸力)을 감소시키는 소위 삼축인장시험을 실시하였다. 인장특성(引張特性)(extensibility)이 상이(相異)한 3종류의 보강재를 사용한 결과 파괴변형율(failure strain), 최대강도후의 응력강소(loss of post-peak strength), 변형모양(deformation mode) 등이 보강재에 따라 각각 독특하였고, 파괴의 양상은 breakage 또는 pull-out 이 발생하였으며, 보강재단(補强材端)의 고정여부에 따라 보강효과가 영향을 받음이 확인되었다. 따라서 보강토해석 및 설계시 흙 및 보강재 자체의 강도(强度)와 더불어 보강재의 인장특성(引張特性)과 경계조건(境界條件)이 매우 중요한 고려요소임을 알 수 있었다.

  • PDF

합류맨홀에서의 유사퇴적 저감을 위한 실험적 연구 (An Experimental Study for Reduction of Sedimentation Deposit in Combining Junction Manholes)

  • 김정수;김경범;윤세의
    • 한국수자원학회논문집
    • /
    • 제45권8호
    • /
    • pp.767-782
    • /
    • 2012
  • 일반적으로 관거 및 맨홀 등의 도시 배수 시스템에서의 유사 및 유송잡물의 퇴적은 유수 흐름의 저항, 합류식 하수도의 조기 운영 및 도시 침수 및 주수로에서의 필연적인 오염 발생 등의 하수도 시설에 심각한 영향을 미친다. 그러므로 배수관과 연결된 합류맨홀에서 유사의 거동 특성 및 퇴적 양상을 분석할 필요가 있다. 본 연구에서는 문헌조사 및 현장조사를 실시하여 실험장치를 제작하고 실험조건을 선정하였다. 선정된 실험조건인 맨홀 형상 조건(사각형, 원형), 유사 유입 조건, 유입 유사량 및 유사 유입 관거를 변화시키면서 실시하였다. 맨홀 내부에 경사형 benching을 설치한 개선형 합류맨홀은 맨홀의 형상에 관계없이 합류맨홀 내 유사퇴적을 저감시키는 데에 상당한 효과를 나타내고 있으므로 도시 배수 시스템에서 개선형 합류맨홀은 관거 시설의 배수능력을 증대시킬 것으로 판단된다.

역률개선 콘덴서를 이용한 유도전동기 기동특성 분석 (Induction Motor Starting Characterization with Power Factor Correction Capacitors)

  • 손석금
    • 한국정보전자통신기술학회논문지
    • /
    • 제10권3호
    • /
    • pp.206-212
    • /
    • 2017
  • 본 논문은 대용량 유도전동기의 기동특성을 분석하였다. 유도전동기 토크는 전류와 자속의 곱으로서 이 자속을 발생시키기 위해서는 여자전류에 해당되는 무효전력이 필요하다. 유도전동기에 필요한 무효전력을 공급하는 방법으로 역률 보상장치를 사용하여 전원측을 대신하여 공급하는 방법을 많이 사용하는데, 역률 보상장치를 사용할 경우 피상전력을 줄일 수 있어 역률을 향상시킬 수 있다. 역률을 개선하기 위한 보상장치를 설치하는 방법으로 부하마다 설치하는 경우와 전체를 일괄 보상하는 방법으로 고압 대용량의 부하로서 일정한 운전패턴을 가지고 있는 경우에는 주로 개별보상이 주로 사용된다. 일반적으로 대용량 유도전동기는 기동 보호장치를 이용하지만 이 논문은 전전압 기동시의 특성을 분석하는 가상의 상황을 가정하여 기동특성에 대한 이론과 실제의 운전특성을 측정 분석하고 역률개선 콘덴서를 이용하여 기동특성을 개선해 보았다.

Neuroprotective Effects of AMP-Activated Protein Kinase on Scopolamine Induced Memory Impairment

  • Kim, Soo-Jeong;Lee, Jun-Ho;Chung, Hwan-Suck;Song, Joo-Hyun;Ha, Joohun;Bae, Hyunsu
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제17권4호
    • /
    • pp.331-338
    • /
    • 2013
  • AMP-activated protein kinase (AMPK), an important regulator of energy metabolism, is activated in response to cellular stress when intracellular levels of AMP increase. We investigated the neuroprotective effects of AMPK against scopolamine-induced memory impairment in vivo and glutamate-induced cytotoxicity in vitro. An adenovirus expressing AMPK wild type alpha subunit (WT) or a dominant negative form (DN) was injected into the hippocampus of rats using a stereotaxic apparatus. The AMPK WT-injected rats showed significant reversal of the scopolamine induced cognitive deficit as evaluated by escape latency in the Morris water maze. In addition, they showed enhanced acetylcholinesterase (AChE)-reactive neurons in the hippocampus, implying increased cholinergic activity in response to AMPK. We also studied the cellular mechanism by which AMPK protects against glutamate-induced cell death in primary cultured rat hippocampal neurons. We further demonstrated that AMPK WT-infected cells increased cell viability and reduced Annexin V positive hippocampal neurons. Western blot analysis indicated that AMPK WT-infected cells reduced the expression of Bax and had no effects on Bcl-2, which resulted in a decreased Bax/Bcl-2 ratio. These data suggest that AMPK is a useful cognitive impairment treatment target, and that its beneficial effects are mediated via the protective capacity of hippocampal neurons.

냉매 과냉각을 이용한 열펌프 시스템의 성능 특성 (The Performance Characteristics of Heat Pump Using the Refrigerant Subcooling)

  • 노건상;손창효
    • 한국수소및신에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.413-421
    • /
    • 2007
  • In this paper, the performance characteristics of heat pump system using a new refrigerant subcooling system designed for the study, are introduced. The new heat pump system have the ice storage tank at the outlet of condenser. The experimental apparatus is a well-instrumented water/water heat pump which consisted of working fluid loop, coolant loop, and ice storage tank. The experiment parameters of subcooling ranged as the evaporating temperature from $-5^{\circ}C$ to $8^{\circ}C$, the condensing temperature from $30^{\circ}C$ to $35^{\circ}C$. The test of the ice storage was carried out at evaporating temperature of $-10^{\circ}C$ and the ice storage mode is Ice-On-Coil type. The working fluid was R-22 and the storage materials were city-water. The test results obtained were as follows; The refrigerant mass flow rate and compressor shaft power were unchanged by the degrees of subcooling, that is, they were independent of degrees of subcooling. The cooling capacity of the new heat pump system increase as the evaporating temperature and subcooling degrees increase and is higher by $25{\sim}30%$, compared to the normal heat pump system. The COP of the new heat pump system increases as the degrees of subcooling and evaporating temperature increase and is higher by 28% than that of the normal heat pump system.

히이트파이프 다발을 이용한 냉축열시스템에서의 대류열전달에 관한 연구 (A Study on the Convective Heat Transfer in a Regenerative Ice Energy System by a Bundle of the Heat-pipes.)

  • 권형정;김경석;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제14권4호
    • /
    • pp.57-66
    • /
    • 1990
  • In the design of an electric power plant, the capacity to meet the peak load demand is one of the important factors to be considered. This peak load usually occurs when the most of the cooling air conditioning systems are being operated during daytime in summer season, which inevitably entails the construction of an additional electric power plant. This study is aimed to carry out a basic experiment for the development of a cooling air conditioning system using the ice energy by the surplus electric power during the night-time. The experimental apparatus consists of four major parts; (1) the heating section consisting of the air duct and I.D. fan, (2) the cold section with the ice chamber, (3) the bundle of heat pipes made in a form of the staggered arrangement with ${C_y}/{d_o}$=2.0 and ${C_x}/{d_o}$=1.73, (4) the refrigerator system to cool down the ice chamber. This study involves an intensive experiment concerning the convective heat transfer of the air flow surrounding the bundle of heat pipes. This major experimental parameters are the amount of working fluid, the velocity of air and the working temperature. The major findings of the present study are as follows; (1) The optimum amount of the working fluid necessary for the horizontal heat pipes is much more than that for the vertical type. (2) The convective heat transfer coefficients of the air are coincided with the empirical equations of Grimson and ${\breve{Z}ukauskas}$. (3) The equation of the mean heat transfer coefficient obtained in the present study is ${N_um}=0.32 {Re_max^{0.63}}$.

  • PDF

화재피해 감소 위한 자동소화장치 적용범위 개선 (Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage)

  • 백창선;박인선
    • 한국안전학회지
    • /
    • 제33권1호
    • /
    • pp.62-65
    • /
    • 2018
  • The rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the "Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems" cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than $300m^2$, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.

Characteristics of Corrosion Fatigue of High Strength Steel for Marine Weld Structure

  • Choi, Seong-Dae;Kubo, Takeo;Misawa, Hiroshi;Lee, Jong-Hyung;Song, Dug-Jung
    • 한국기계가공학회지
    • /
    • 제2권4호
    • /
    • pp.53-60
    • /
    • 2003
  • Large sized marine structures are used under corrosion environment of seawater and applied by severe service loading such as an ocean current, a billow and a tempest. Marine structures are usually constructed by lots of thick wall steel pipes joining welded joints. The thickness of such as steel pipes is usually more than 40mm. The such as steels are called "Thermo-Mechanical Control Process steel (TMCP steel)" strengthened by a heat treatment in process of steel manufactures. The failure, especially crack initiation, of marine structures was starting at weld joints under service condition. Then they should be designed by basis of the fatigue strength under seawater corrosion environment of weld joints. To clarity the fatigue crack initiation behavior is important more than to clarify the crack propagation behavior on the strength design of marine structures, because it is very difficult to find out the crack initiation and propagation phenomena and then even if it will be able to find out, it is considered that the refit of the damaged parts of welded joints have a technical difficulty under the sea. Therefore, it is most important to clarify the corrosion fatigue crack initiation behavior under the seawater condition. But, there is one big difficulty to make a test for thick plate specimen, for example thicker than 40mm. Because, it is need large capacity loading apparatus to test such as thick plate specimen. In this research, the new configuration specimen for fatigue crack initiation tests was proposed. Using this new specimen, it is easy to carry out the fatigue clack initiation tests with relatively low cyclic loading and to observe a fatigue crack initiation behavior.

  • PDF