• 제목/요약/키워드: Apical preparation size

검색결과 34건 처리시간 0.018초

감염근관에서의 apical preparation size (APICAL PREPRATION SIZE IN INFECTED ROOT CANALS)

  • 금기연
    • Restorative Dentistry and Endodontics
    • /
    • 제35권1호
    • /
    • pp.1-4
    • /
    • 2010
  • 감염근관에서의 주치근단 파일의 크기는 학자들마다 많은 논란이 되고 있지만 최근 여러 연구 결과들은 감염근관의 효과적인 세정을 위해서는 근단부 확대 크기가 증가해야 함을 보여주고 있다. 따라서 임상가는 감염근관의 치료 시 새로운 개념에 맞는 치료 전략을 가지고 근관치료에 임해야 한다.

Incidence of apical crack formation and propagation during removal of root canal filling materials with different engine driven nickel-titanium instruments

  • Ozyurek, Taha;Tek, Vildan;Yilmaz, Koray;Uslu, Gulsah
    • Restorative Dentistry and Endodontics
    • /
    • 제42권4호
    • /
    • pp.332-341
    • /
    • 2017
  • Objectives: To determine the incidence of crack formation and propagation in apical root dentin after retreatment procedures performed using ProTaper Universal Retreatment (PTR), Mtwo-R, ProTaper Next (PTN), and Twisted File Adaptive (TFA) systems. Materials and Methods: The study consisted of 120 extracted mandibular premolars. One millimeter from the apex of each tooth was ground perpendicular to the long axis of the tooth, and the apical surface was polished. Twenty teeth served as the negative control group. One hundred teeth were prepared, obturated, and then divided into 5 retreatment groups. The retreatment procedures were performed using the following files: PTR, Mtwo-R, PTN, TFA, and hand files. After filling material removal, apical enlargement was done using apical size 0.50 mm ProTaper Universal (PTU), Mtwo, PTN, TFA, and hand files. Digital images of the apical root surfaces were recorded before preparation, after preparation, after obturation, after filling removal, and after apical enlargement using a stereomicroscope. The images were then inspected for the presence of new apical cracks and crack propagation. Data were analyzed with ${\chi}^2$ tests using SPSS 21.0 software. Results: New cracks and crack propagation occurred in all the experimental groups during the retreatment process. Nickel-titanium rotary file systems caused significantly more apical crack formation and propagation than the hand files. The PTU system caused significantly more apical cracks than the other groups after the apical enlargement stage. Conclusions: This study showed that retreatment procedures and apical enlargement after the use of retreatment files can cause crack formation and propagation in apical dentin.

Cutting efficiency of apical preparation using ultrasonic tips with microprojections: confocal laser scanning microscopy study

  • Kwak, Sang-Won;Moon, Young-Mi;Yoo, Yeon-Jee;Baek, Seung-Ho;Lee, WooCheol;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.276-281
    • /
    • 2014
  • Objectives: The purpose of this study was to compare the cutting efficiency of a newly developed microprojection tip and a diamond-coated tip under two different engine powers. Materials and Methods: The apical 3 mm of each root was resected, and root-end preparation was performed with upward and downward pressure using one of the ultrasonic tips, KIS-1D (Obtura Spartan) or JT-5B (B&L Biotech Ltd.). The ultrasonic engine was set to power-1 or -4. Forty teeth were randomly divided into four groups: K1 (KIS-1D / Power-1), J1 (JT-5B / Power-1), K4 (KIS-1D / Power-4), and J4 (JT-5B / Power-4). The total time required for root-end preparation was recorded. All teeth were resected and the apical parts were evaluated for the number and length of cracks using a confocal scanning micrscope. The size of the root-end cavity and the width of the remaining dentin were recorded. The data were statistically analyzed using two-way analysis of variance and a Mann-Whitney test. Results: There was no significant difference in the time required between the instrument groups, but the power-4 groups showed reduced preparation time for both instrument groups (p < 0.05). The K4 and J4 groups with a power-4 showed a significantly higher crack formation and a longer crack irrespective of the instruments. There was no significant difference in the remaining dentin thickness or any of the parameters after preparation. Conclusions: Ultrasonic tips with microprojections would be an option to substitute for the conventional ultrasonic tips with a diamond coating with the same clinical efficiency.

Does minimally invasive canal preparation provide higher fracture resistance of endodontically treated teeth? A systematic review of in vitro studies

  • Sila Nur Usta;Emmanuel Joao Nogueira Leal Silva;Seda Falakaloglu;Mustafa Gundogar
    • Restorative Dentistry and Endodontics
    • /
    • 제48권4호
    • /
    • pp.34.1-34.12
    • /
    • 2023
  • This systematic review aimed to investigate whether minimally invasive root canal preparation ensures higher fracture resistance compared to conventional root canal preparation in endodontically treated teeth (ETT). A comprehensive search strategy was conducted on the "PubMed, Web of Science, and Scopus" databases, alongside reference and hand searches, with language restrictions applied. Two independent reviews selected pertinent laboratory studies that explored the effect of minimally invasive root canal preparation on fracture resistance, in comparison to larger preparation counterparts. The quality of the studies was assessed, and the risk of bias was categorized as low, moderate, or high. The electronic search yielded a total of 1,767 articles. After applying eligibility criteria, 8 studies were included. Given the low methodological quality of these studies and the large variability of fracture resistance values, the impact of reduced apical size and/or taper on the fracture resistance of the ETT can be considered uncertain. This systematic review could not reveal sufficient evidence regarding the effect of minimally invasive preparation on increasing fracture resistance of ETT, primarily due to the inherent limitations of the studies and the moderate risk of bias.

Effect of repetitive pecking at working length for glide path preparation using G-file

  • Ha, Jung-Hong;Jeon, Hyo-Jin;Abed, Rashid El;Chang, Seok-Woo;Kim, Sung-Kyo;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제40권2호
    • /
    • pp.123-127
    • /
    • 2015
  • Objectives: Glide path preparation is recommended to reduce torsional failure of nickel-titanium (NiTi) rotary instruments and to prevent root canal transportation. This study evaluated whether the repetitive insertions of G-files to the working length maintain the apical size as well as provide sufficient lumen as a glide path for subsequent instrumentation. Materials and Methods: The G-file system (Micro-Mega) composed of G1 and G2 files for glide path preparation was used with the J-shaped, simulated resin canals. After inserting a G1 file twice, a G2 file was inserted to the working length 1, 4, 7, or 10 times for four each experimental group, respectively (n = 10). Then the canals were cleaned by copious irrigation, and lubricated with a separating gel medium. Canal replicas were made using silicone impression material, and the diameter of the replicas was measured at working length (D0) and 1 mm level (D1) under a scanning electron microscope. Data was analysed by one-way ANOVA and post-hoc tests (p = 0.05). Results: The diameter at D0 level did not show any significant difference between the 1, 2, 4, and 10 times of repetitive pecking insertions of G2 files at working length. However, 10 times of pecking motion with G2 file resulted in significantly larger canal diameter at D1 (p < 0.05). Conclusions: Under the limitations of this study, the repetitive insertion of a G2 file up to 10 times at working length created an adequate lumen for subsequent apical shaping with other rotary files bigger than International Organization for Standardization (ISO) size 20, without apical transportation at D0 level.

수동과 엔진구동형 기구를 이용한 난원형 근관의 형성에 관한 주사전자현미경적 관찰 (A SEM OBSERVATION ON THE EFFICIENCY PREPARATION OF OVAL CANALS USING HAND AND ENGINE-DRIVEN INSTRUMENTS)

  • 송욱;허복;이희주
    • Restorative Dentistry and Endodontics
    • /
    • 제29권2호
    • /
    • pp.141-146
    • /
    • 2004
  • The purpose of this study was to evaluate the efficiency of the preparation of oval canals using hand and engine-driven instruments with SEM observation. Thirty single-rooted teeth with oval canal were used in this study. The teeth were divided into 3 groups. In group A the teeth were instrumented up to a size 35 K-file using RC-prep and irrigated with 5% NaOCl between each file size. In group B. the teeth were instrumented with Profile according to the manufacture's instructions using RC-Prep and irrigated with 5% NaOCl between each file size. In group C. the teeth were instrumented with GT file according to the manufacture's instructions using RC-prep and irrigated with 5% NaOCl between each file size. Then. in all teeth. a final flush of 5ml of distilled water delivered for 30s. Canals were dried with sterile standardized paper points. After preparing the canals, the teeth were sectioned along their mesial and diatal surfaces by using low-speed diamond disc. chisel and mallet. Each root section was then dehydrated in graded concentration of alcohol (70, 80, 90, 100%). mounted on an aluminum stub. sputter-coated with gold-palladium and observed with scanning electron microscope (HITACHI S-4200) in middle and apical area. The results of this study were as follows: 1. In the middle area. group B and group C showed less smear layer than group A and it was statistically significant (p < 0.05). 2. In the middle area. group B showed greater smear layer than group C. but it was not statistically significant (p > 0.05). 3. In the apical area, group C showed less smear layer than group A. and it was statistically significant (p < 0.05). 4. In the apical area. group A showed greater smear layer than group B. but it was not statistically significant (p > 0.05). 5. In the apical area. group B showed greater smear layer than group C. but it was not statistically significant (p > 0.05). 6. In all groups. the middle area was less smear layer than the apical area. and it was statistically significant (p < 0.05).

수 종의 Ni-Ti 회전 기구들을 이용한 치근단 폐쇄 향상을 위한 근관 확대 평가 (Evaluation of canal preparation for apical sealing with various Ni-Ti rotary instruments)

  • 신유석;신수정;송민주;김의성
    • Restorative Dentistry and Endodontics
    • /
    • 제36권4호
    • /
    • pp.300-305
    • /
    • 2011
  • 연구목적: 본 연구의 목적은 원형의 치근단 삭제를 제공하는 능력에 관한 수 종의 Ni-Ti 회전 기구들을 평가하는 것이다. 연구 재료 및 방법: 실험은 50개의 단근치를 선택하여 백악상아질 경계에서 절단하였고, 근관의 치관부 1/3은 Gates Glidden bur (#2, #3, #4)를 이용하여 확대하였다. 시편들은 각 군당 10개씩 5개의 실험군들로 나누었다. 1군은 GT file, Profile .04, Quantec #9, #10을 사용했고, 2군은 1군과 유사하나 Quantec 파일 대신 Lightspeed를 사용했고, 3군은 Orifice shaper, Profile .06 종류들, Lightspeed를 사용했고, 4군은 3군과 유사하나 Lightspeed 대신 Quantec #9, #10를 사용했고, 5군은 근관 확대를 위해 GT file, Profile .04를 사용했다. 모든 치아 시편들은 치근첨으로부터 1 mm, 3 mm, 5 mm에서 절단하여 현미경하에서 관찰했다. 결과: 본 연구의 결과 실험군 2, 3군(Lightspeed file군)이 실험군 1, 4군(Quantec), 실험군 5군(GT file, profile .04종류들)에 비하여 치근단 1 mm에서 더 원형에 가까운 치근단 삭제를 보였다(p < 0.05). 치근단 3, 5 mm들에서는 각 군들 사이에서 통계학적 유의차가 없었다. 치근단 5 mm 시편들에서는 대부분의 시편들이 완전한 원형을 나타내었으며 불규칙한 모양은 관찰되지 않았다. 결론: 치근단 1 mm 시편에서 Lightspeed를 사용한 경우에서 다른 Quantec, GT와 Profile .04 종류들을 사용한 것보다 더 원형의 삭제를 얻었고, 근관장에서 최초의 Lightspeed에 맞는 크기보다 ISO 크기보다 3단계 크기 확대로는 모든 치근단 1 mm에서 원형의 삭제를 얻었을 수 없었고 단지 35%에서만 원형의 삭제를 얻을 수 있었다는 것이다. 따라서 ISO 크기보다 3단계 크기 확대가 원형 삭제를 얻기에는 불충분하며 좀 더 큰 크기로 확대하는 것이 필요함을 알 수 있으나 치아에 따라 치근단 부위 치질의 양이 다를 수 있으므로 일률적으로 적용하기에는 무리가 있을 수 있다.

근단부 성형 크기에 따른 다양한 전동 니켈티타늄 파일의 중심 변위율 및 만곡도 감소 비교 (Comparison of the centering ratio and canal curvature reduction according to the apical preparation size using various NiTi rotary instruments)

  • 곽상원;박정길;허복;김현철
    • 대한치과의사협회지
    • /
    • 제47권7호
    • /
    • pp.435-443
    • /
    • 2009
  • The purpose of this study was to compare the centering ratio and reduction of canal curvature according to the preparation sizes of #30, #40 and #50 using three rotary NiTi instruments which have different shaft tapers. Seventy-two simulated root canals in clear resin blocks (Endo Training Bloc; Dentsply Maillefer, Ballaigues, Switzerland) were divided as following 3 groups according to the file system; the 24 canal blocks prepared with each of ProTaper Universal system (Group P), LightSpeed eXtra system (Group L), and K3 (Group K). The pre- and post-instrumented root canals were scanned and superimposed to evaluate and calculate the centering ratio and reduction of canal curvature. Mean scores of each group were statistically analyzed using one-way ANOV A and Duncan's multiple range test for post-hoc comparison. The results were as followings: 1. Group L showed better centering ratio, followed by K and P. And all experimental groups generally showed increasing tendency of centering ratio as the apical size was increasing from #30 to #50, except at 1 mm level of group P where showed reducing tendency of centering ratio. The smaller the ratio, the better the instrument remained centered in the canal. 2. Group P showed more decrease of canal curvature at all apical shaping size (p < 0.05). Under the conditions of this study, the shaft design could affect the quality of canal shaping and the smooth taperless flexible (LightSpeed) shaft design was capable of preparing canals with good morphological characteristics in curved canals.

  • PDF

Apical root canal cleaning after preparation with endodontic instruments: a randomized trial in vivo analysis

  • Fornari, Volmir Joao;Hartmann, Mateus Silveira Martins;Vanni, Jose Roberto;Rodriguez, Rubens;Langaro, Marina Canali;Pelepenko, Lauter Eston;Zaia, Alexandre Augusto
    • Restorative Dentistry and Endodontics
    • /
    • 제45권3호
    • /
    • pp.38.1-38.10
    • /
    • 2020
  • Objectives: This study aimed to evaluate vital pulp tissue removal from different endodontic instrumentation systems from root canal apical third in vivo. Materials and Methods: Thirty mandibular molars were selected and randomly divided into 2 test groups and one control group. Inclusion criteria were a positive response to cold sensibility test, curvature angle between 10 and 20 degrees, and curvature radius lower than 10 mm. Root canals prepared with Hero 642 system (size 45/0.02) (n = 10) and Reciproc R40 (size 40/0.06) (n = 10) and control (n = 10) without instrumentation. Canals were irrigated only with saline solution during root canal preparation. The apical third was evaluated considering the touched/untouched perimeter and area to evaluate the efficacy of root canal wall debridement. Statistical analysis used t-test for comparisons. Results: Untouched root canal at cross-section perimeter, the Hero 642 system showed 41.44% ± 5.62% and Reciproc R40 58.67% ± 12.39% without contact with instruments. Regarding the untouched area, Hero 642 system showed 22.78% ± 6.42% and Reciproc R40 34.35% ± 8.52%. Neither instrument achieved complete cross-sectional root canal debridement. Hero 642 system rotary taper 0.02 instruments achieved significant greater wall contact perimeter and area compared to reciprocate the Reciproc R40 taper 0.06 instrument. Conclusions: Hero 642 achieved higher wall contact perimeter and area but, regardless of instrument size and taper, vital pulp during in vivo instrumentation is not entirely removed.

전동 file을 장착한 Tri Auto ZX®의 치근단공 인지 정확도 평가 (ACCURACY OF TRI AUTO ZX® IN LOCATING APICAL FORAMEN WITH ROTARY FILE)

  • 박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제24권4호
    • /
    • pp.578-584
    • /
    • 1999
  • The purpose of this experiment was to determine: (1) the safe automatic apical reverse setting that prevents overinstrumentation of the root canal, using Tri Auto ZX$^{(R)}$ and (2) the effect of various irrigant on such instrumentation. The instrumentation was carried out with the automatic apical reverse setting of 0.5, 1.0, 1.5, and 2.0. The root canal irrigants used in usual manner were normal saline(0.9%), NaOCl(2.5%), and RC Prep$^{(R)}$. For each reverse setting and each irrigant, ten teeth were used with the total of 120 teeth. The distance between the file tip and the apical constriction was determined by stereomicroscope using the point that the file began to rotate in reverse direction. When the reverse setting mode was set to 0.5, 18 of 30 were overinstrumented. If these were discriminated by irrigant, 10 of 6 with 0.9% saline, 10 of 6 with NaOCl, and 10 of 6 with RC Prep$^{(R)}$ has the file tip located 0.57${\pm}$0.30mm, 0.73${\pm}$0.39mm, and 0.26${\pm}$0.25mm beyond the apical constriction respectively. In 1.0 setting 15 of 29 were over the apical constriction, and the distribution was 6 in saline, 5 in NaOCl, and 4 in RC Prep$^{(R)}$. The mean distance over the apical constriction was 0.28${\pm}$0.13mm with saline, 0.75${\pm}$0.61mm with NaOCl, and 0.25${\pm}$0.17mm with RC Prep$^{(R)}$. When the autoatic reverse mode was set to 1.5, and 2.0, 5, and 1 teeth were found to be overinstrumented in respective settings. But there were large variations in overinstrumented distances when an attempt was made to compare the effect of irrigants on this overinstrumentations and they were meaningless for the small sample size. When all of the autoreverse setting were combined to compare the number of overinstrumented teeth with each irrigant, there were no significant differences (14 for normal saline, 12 for NaOCl, 13 for RC Prep$^{(R)}$). When 0.5 or 1.0 automatic apical reverse setting mode was used the Tri Auto ZX$^{(R)}$ in clinical application, the possibility of overinstrumentation beyond the apical constriction exists in 55.9% of cases. Therefore 1.5 or 2.0 setting is safer for the preparation inside the canal but this type setting needs additional apical hand preparation of the root canal because the accuracy is lower than 0.5 or 1.0 setting.

  • PDF