• Title/Summary/Keyword: Apartment fire

Search Result 198, Processing Time 0.026 seconds

Development and Review of Virtual Reality Fire-Training Program (공동주택 화재를 대상으로 한 가상현실(VR) 프로그램 개발 및 호응도 조사)

  • Kim, Yong-Cheol;Jeong, Mu-Heon;Lyu, Chung;Kim, Sun-Gyu
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.159-164
    • /
    • 2019
  • This study aims to minimize casualties in the event of an apartment fire by developing a virtual reality (VR) fire-training program (using the latest IT techniques) and verifying its validity as a learning tool. For this purpose, environmental parameters, such as the unit floor's size and the composition of the family, were established. Then, possible fire scenarios that could occur in the apartment building were developed and implemented in a VR setting. Finally, a survey was conducted to review the responses to the program. The results of the survey demonstrated that the responses were positive, confirming the effectiveness of the program.

Experimental study on the sound attenuation of the fire alarm sounder system in apartment buildings (공동주택 화재경보 발생음 특성에 관한 실험연구)

  • Lee, Min-Joo;Kang, Hee-Hyuk;Kwon, Bong-Suk;Kim, Myung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1162-1168
    • /
    • 2007
  • In many fire emergencies, the audible fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the fire alarm worked. This is the study to show the sound attenuation of the fire alarm sounder system in apartment buildings. We measured and analyzed the sound attenuation level in 17 units, and the results were compared with the minimum sound level at sleeping area by NFPA(National Fire Protection Association) 72. When only the fire alarm worked in stair hall, the sound levels in bedroom were in the range of $30.6{\sim}42.8dB(A)$ and the differences between sound level and ambient sound level in bedrooms were in the range of $7.1{\sim}13.8dB(A)$. And when the emergency broadcasting device in the livingroom and the fire alarm worked simultaneously, the sound levels in bedrooms were in the range of $54.2{\sim}63.0dBA$. Finally, it was showed that the fire alarm sounder system didn't give a sufficient sound level in bedroom to awake out of sleep.

  • PDF

A Study on the Characterization of Fire Plume Ejected from an Opening according to the Opening Form and the Balcony of Apartment in Korea (국내 공동주택의 개구부형태 및 발코니 유·무에 따른 분출화염 성상에 관한 연구)

  • Lee, Kyu-Min;Koo, Tae-Yoon;Hwang, Eu-Cheong;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.37-38
    • /
    • 2017
  • This study identified the effects of flame on the upper by fire plume ejected. we implemented model experiment according to investigation of housing area effect, window aspect ratio and balcony availability. we confirmed that opening ratio was increased according to housing area larger. the square window confirmed that is progressing fire plume ejected of free space. According to the value of an opening aspect ratio 'n' getting higher, the horizontal widow is getting that increased the risk as the fire spread an external to the top of opening. it is determined to the fundamental solution about fire safety in the extended balcony of apartment.

  • PDF

A MULTI-STORY FIRE IN HIGH-RISE APARTMENT BUILDING DEVELOPED THROUGH BALCONIES - INVESTIGATION AND EXPERIMENTS -

  • Hasemi, Yuji;Hayashi, Yoshihiko;Hokugo, Akihiko;Yoshida, Masashi
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.361-368
    • /
    • 1997
  • Summary of experiments for the investigation of a fire which caused an upward fire spread for over 12 floors through balconies in a high-rise apartment complex is reported. The experiments include indoor tests to obtain fire properties of vertical PMMA fences and outdoor ones with a full scale model of the balcony. The test results suggest significance of the increase of total flame height by the merging of flames and a cooperative effect of the burning of the PMMA fence and combustibles on the balconies for the generation of a tall flame enough to cause ignition on the upper floors.

  • PDF

Full Scale Experiment of Fire Phenomena in case of Reinforced Concrete Structured Apartment Building -Regarding the enclosure fire growth and the structural fire vulnerability findings- (철근콘크리트 구조 공동주택 실물화재 실험 연구 -화재성상 파악 및 취약부위 도출을 중심으로-)

  • 윤명오
    • Fire Science and Engineering
    • /
    • v.10 no.3
    • /
    • pp.41-50
    • /
    • 1996
  • In many of the developed countries, there have been continuous offers to observe and understand the fire phenomenon for the establishment of fire safety and the development of fire protection technology. In the past, full scale fire experiments have been conducted for the development of the construction technology and the design methods in order to secure the safety of the buildings and the people as well. This study aims at the statistics concerning the structural vulnerablity parts based on the full scale fire experiment in one of the apartment buildings that represents the average households in Korea, thereby acquring the experimental technology, and the basic data needed for the prediction of enclosure fire phenomenon which is critical for the establishment of evalution methods through simulation, and has also presents secured problems concerning the balcony structure and the window types that requires imediate improvement.

  • PDF

A Full-scale Fire Test of an Apartment House (공동주택 실물화재 실험)

  • Kim, Myung-Bae;Han, Yong-Shik;Choi, Byung-Il;Do, Kyu-Hyung;Lee, Yu-Whan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.415-422
    • /
    • 2009
  • 국내 저층 공동주택 화재시의 화재 전파 경로와 상층으로의 화재 전파를 살펴보기 위하여 4층 공동 주택을 대상으로 실물화재 실험을 수행하였다. 화재는 3층 주택에서 발화하는 것으로 하였고, 초기 화원은 주방에서 과열된 식용유에 발화되어 발생하는 것으로 하였다. 주택 내부 가연물은 일반 가정의 필수 가연물을 모두 포함 하였다. 내부 화재 성상을 확인하기 위하여 가시화, 주요부의 온도측정, 산소농도 측정을 수행하였다. 실험 결과 초기 화원의 발화 시간, 화재 층 내부 각 구획으로의 전파시간, 전역화재 발생시간을 파악하였으며, 상층으로의 연소확대 경로를 파악하였다.

  • PDF

A Study on the Reverberation Time Characteristics of Inside Space of Apartment Buildings (공동주택 내부 공간의 잔향시간 특성 조사 연구)

  • Jeong, Jeong Ho;Lee, Byung Kwon;Jeon, Jin Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.4
    • /
    • pp.291-298
    • /
    • 2015
  • In this study, the reverberation time of apartment living room was measured and distribution of the reverberation time was analyzed. In addition, sound field characteristics of mock-up test room similar with living room and timber structured bedroom was investigated with addition of furniture and sound absorption material. Average reverberation time of unfurnished apartment unit was 1.11 s, and reverberation time in 630 Hz~2000 Hz bands were longer than 1.2 s. It was found that from the field measurement results, reverberation time characteristic of furnished apartment living room was uniform in most of frequency bands. Averaged reverberation time of furnished living room was 0.48 s and the reverberation time of bedroom was 0.44 s. Standardized sound pressure level correction values were calculated from the average reverberation time of furnished and unfurnished apartment units. The correction value of unfurnished living room was −3.4 dB and that of furnished living room was 0.2 dB. Measured reverberation time of furnished and unfurnished apartment units indicated that reference reverberation time; 0.5 s, in KS and ISO standards is reasonable also in Korean residential environment.

An Study on the Sound Attenuation and the Improvement in Hearing Condition of Fire Alarm Device in Apartment Buildings (공동주택 화재 경보음 전달특성과 개선방안 고찰)

  • Lee, Min-Joo;Yoon, Myong-O;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.6 s.111
    • /
    • pp.593-601
    • /
    • 2006
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10 dBA. To give the minimum sound level 60 dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.