• Title/Summary/Keyword: Aorta

Search Result 1,434, Processing Time 0.025 seconds

Intracardiac Migration of a Renal Stent from the Left Renal Vein to the Right Ventricle during the Treatment of Nutcracker Syndrome - A case report - (Nutcracker Syndrome를 위해 왼콩팥정맥에 삽입한 스텐트의 우심실 이동 - 1예 보고 -)

  • Kim, JaeBum;Choi, Sae-Young;Park, Nam-Hee;Kum, Dong-Yoon;Park, Hoon;Hwang, Eun Ah
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.100-103
    • /
    • 2010
  • We report her on a rare case of a renal stent that migrated into the right ventricle in a patient with nutcracker syndrome. A 29-year-old woman was admitted to the hospital and she was suffering from flank pain. The computed tomography of the abdomen demonstrated that the left renal vein was compressed between the abdominal aorta and the superior mesenteric artery (nutcracker syndrome). A self expandable stent was placed across the left renal vein for treating her nutcracker syndrome. The next day after the procedure, the follow up chest radiograph showed that the displaced stent had migrated into the right ventricle. After percutanous endovascular stent removal had failed, the stent was ultimately removed by performing cardiac surgery. At the $6^{th}$ postoperative month, there have been no abdominal or cardiac symptoms.

Study on the Mechanism of Vascular Relaxation of Methanol Extract of Rose multiflora Radix (장미근(薔薇根) 메탄올 추출물의 혈관이완 기전에 대한 연구)

  • Kim, Dae-Joong;Jo, Nam-Geun;Lee, Jun-Kyoung;Cao, Li-Hua;Lee, Hyuck;An, Jung-Seok;Um, Jae-Yeon;Joe, Gye-One;Na, Han-Il;Kyung, Eun-Ho;Kang, Dae-Gil;Lee, Ho-Sub
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.21 no.2
    • /
    • pp.408-413
    • /
    • 2007
  • Vascular tone plays an important role in the regulation of blood pressure. In the present study, the methanol extract of Rosae multiflora Radix (MRM) induced dose-dependent relaxation of phenylephrine-precontracted aorta, which was abolished by removal of functional endothelium. Pretreatment of the endothelium-intact aortic tissues with $N^G$-nitro-L-arginine methly ester (L-NAME) or 1H-[1,2,4]-oxadiazole-[4,3-${\alpha}$]-quinoxalin-1-one (ODQ) inhibited the relaxation induced by MRM, respectively. But, the relaxation effect of MRM was not blocked by indomethacine, glibenclamide, tetraethylammonium (TEA), verapamil, diltiazem, atropine, and propranolol, respectively. Moreover, incubation of endothelium-intact aortic rings with MRM increased the production of cGMP. Taken together, the present results suggest that MRM relaxes vascular smooth muscle via endothelium-dependent nitric oxide/cGMP signaling. These results would be useful for further study to MRM on animal models with cardiovascular diseases.

Surgical Treatment of the Aortic Aneurysm (대동맥류의 외과적 치료)

  • 김학제;조원민;김태식;이송암;김욱진;손영상;최영호
    • Journal of Chest Surgery
    • /
    • v.31 no.1
    • /
    • pp.13-19
    • /
    • 1998
  • Aortic aneurysm has poor prognosis and high mortality, but the incidence of aortic aneurysm is in increasing state. From July, 1986 to July, 1996, we operated on 25 patients with aortic aneurysm and analysed the clinical results and relations between the duration from symptoms onset to operation(Sx-Op), the duration from admission to operation(Adm-Op), preoperative blood pressure, preoperative heart rate and postoperative mortality, retrospectively. The patients were classified as dissecting aneurysm(10 cases), abdominal aortic aneurysm(9 cases), Marfan's syndrome(3 cases), descending thoracic aortic aneurysm(3 cases). The operative technique were graft interposition in 17 cases, Bentall's operation in 4 cases, aneurysm bypass in 2 cases, and wrapping of aorta in 2 cases. Seven patients died of several causes, bleeding in 5 cases, acute renal failure in 1 case and respiratory failure in another one case. Before 1992, the early stage of operation, 6 mortality among 14 operated patients occurred, and after then 1 mortality among 11 operated patients occurred. Eighteen survivors were followed up from 1 to 118 months(mean 50.6 months), and total follow up was 911 patient-months. During the follow up period one patient died of melena 30 months after operation. The other patients did not complain chest pain or dyspnea. The surgical mortality was improved in the late period, and the major cause of death was intraoperative or postoperative bleeding. The Sx-Op duration, the Adm-Op duration, preoperative blood pressure and preoperative heart rate were proven to have no statistical relations with postoperative mortality.

  • PDF

Clamp and Sew Technique without Distal Perfusion for the Management of Traumatic Descending Thoracic Aortic Rupture (외상성 흉부 하행 대동맥 파열에서 원위부 관류 없이 시행한 겸자 봉합술)

  • Seok, Yang-Ki;Lee, Jong-Tae;Kim, Gun-Jik;Park, Il;Cho, Joon-Yong
    • Journal of Chest Surgery
    • /
    • v.40 no.8
    • /
    • pp.558-563
    • /
    • 2007
  • Background: Traumatic aortic rupture is a highly fatal condition in which a patient's outcome is strongly affected by other associated injuries. Selection of the appropriate surgical timing and the management plan is important. Material and Method: The medical records of the 15 traumatic descending thoracic aortic rupture patients who underwent the clamp & sew technique were retrospectively reviewed and checked for the presence of associated injuries and the postoperative course. Result: The hospital mortality was 6.07% (one patient). This patient died intra-operatively and the cause of the death was delayed hemoperitoneum. The mean operative time and aortic clamp time were $231{\pm}53.1$ and $13.1{\pm}5.3$ minutes, respectively. One patient complained the bowel obstructive symptoms at postoperative 10 days. We found the mechanical bowel obstruction on computed tomography of the abdomen, and segmental bowel resection was done. Conclusion: Although several surgical strategies may be appropriate for managing traumatic aortic rupture, the clamp & sew technique is a safe and effective method for the treatment of traumatic aortic injury.

Development of Artificial Vessels with Autologous Bone Marrow Cells and Polymers (자기 골수세포와 고분자 폴리머를 이용한 인공 혈관의 개발)

  • Choi, Jin-Wook;Lim, Sang-Hyun;Hong, You-Sun;Kim, Byung-Soo
    • Journal of Chest Surgery
    • /
    • v.41 no.2
    • /
    • pp.160-169
    • /
    • 2008
  • Bakcground: To treat anastomosis site stenosis and occlusion of the artificial vessels used in vascular surgery, tissue-engineered artificial vessels using autologous cells have been constructed. We developed artificial vessels using a polymer scaffold and autologous bone marrow cells and performed an in vivo evaluation. Material and Method: We manufactured a vascular scaffold using biodegradable PLCL (poly lactide-co-${\varepsilon}$-caprolactone) and PGA (poly glycolic acid) fibers. Then we seeded autologous bone marrow cells onto the scaffold. After implantation of the artificial vessel into the abdominal aorta, we performed an angiography 3 weeks after surgery. After the dogs were euthanized we retrieved the artificial vessels and performed histological analysis. Result: Among the six dogs, 2 dogs died of massive bleeding due to a crack in the vascular scaffold 10 days after the operation. The remaining four dogs lived for 3 weeks after the operation. In these dogs. the angiography revealed no stenosis or occlusion at 3 weeks after the operation. Gross examination revealed small thrombi on the inner surface of the vessels and the histological analysis showed three layers of vessel structure similar to the native vessel. Immunohistochemical analysis demonstrated regeneration of the endothelial and smooth muscle cell layers. Conclusion: A tissue engineered vascular graft was manufactured using a polymer scaffold and autologous bone marrow cells that had a structure similar to that of the native artery. Further research is needed to determine how to accommodate the aortic pressure.

Anaortic Off-pump Coronary Artery Bypass Grafting in Patients with Takayasu's Arteritis

  • Na, Kwon Joong;Lee, Kyung-Hak;Oh, Se Jin;Hwang, Ho Young;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.274-278
    • /
    • 2013
  • Background: Coronary involvement in Takayasu's arteritis is a rare but fatal disease. The aim of this study was to evaluate the early and mid-term results of Takayasu's arteritis patients who underwent coronary artery bypass grafting (CABG). Materials and Methods: Of 2,280 patients who underwent isolated CABG from January 1998 to June 2012, Takayasu's arteritis was identified in 5 patients. There were 3 female patients, and the mean age was $58{\pm}9$ years. Takayasu's arteritis was diagnosed during preoperative evaluation for coronary artery disease in 4 patients, and the initial manifestation was angina pectoris in 4 patients. All of the patients underwent anaortic off-pump CABG (OPCAB) using the in situ left or right internal thoracic arteries (ITA); 3 patients had severe stenosis of the proximal left subclavian artery and the in situ right ITA was used instead. Medical treatment for inflammatory arteritis during the perioperative and follow-up period was performed if indicated. Early, 1-year, and 5-year angiographic results and clinical outcomes were analyzed. Results: There was no surgical mortality, and all of the patients were discharged without complications on postoperative $8{\pm}2$ days. Early postoperative (postoperative $2{\pm}1$ days) angiography demonstrated a graft patency of 100% (12 of 12 distal anastomoses). One-year ($13{\pm}3$ months) angiography was performed in 4 patients, and all of the grafts were patent (100%, 9 of 9 distal anastomoses). Conclusion: By performing anaortic OPCAB in patients with Takayasu's arteritis, we were able to avoid complications associated with manipulating an atherosclerotic and severely calcified ascending aorta. The early and mid-term graft patency of OPCAB in Takayasu's arteritis was maintained when concomitant with medical treatment.

Modeling of Hemodynamics in Stenosed Artery (협착 동맥혈관의 혈류유동 모델링)

  • Kim, Seong-Jong;Park, Young-Ran;Kim, Shagn-Jin;Kang, Hyung-Sub;Kim, Jin-Shang;Oh, Sung-Hoon;Kang, Sung-Jun;Kim, Gi-Beum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.5
    • /
    • pp.2285-2290
    • /
    • 2012
  • This study is about atherosclerosis which occupies the highest rate in many diseases people have and we have studied about atherosclerosis for abdominal aorta. Atherosclerosis is the phenomenon which blood vessel gets narrower, harder and thicker due to the stenosis of colesterol in blood vessel. If it becomes worse, arteries will be hard and blood can't flow smoothly, and even it can reach to death. In this study, the geometric models of the considered stenotic blood flow are two different types of constriction of cross-sectional area of blood vessel; 20 and 45% of constriction in each elastic wall and rigid wall. We have modeled by using finite element method to observe the changes of velocity and pressure. In case of the diameter of blood vessel decreased 45% in elastic wall model, the values of velocity and pressure were higher than the case of 20% and in case of the diameter of blood vessel decreased 45% in rigid wall model, the values of velocity and pressure were higher than the case of 20%. In cases of elastic wall models of the diameters of blood vessels decreased each of 20% and 45%, recirculation zones appeared. This results show understanding of hemodynamic properties depending on stenosed blood vessels.

A study of image evaluation and exposure dose with the application of Tube Voltage and ASIR of Low dose CT Using Chest Phantom (흉부 Phantom을 이용한 Low Dose CT의 관전압과 ASIR(Adaptive Statistical Iterative Reconstruction)적용에 따른 영상평가 및 피폭선량에 관한 연구)

  • Hwang, Hyeseong;Kim, Nuri;Jeong, Yoonji;Goo, Eunhoe;Kim, Kijeong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.9-14
    • /
    • 2014
  • Purpose: The purpose of this study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying Filtered Back Projection(FBP), the existing test method, and Adaptive Statistical Iterative Reconstruction(ASIR) with different values of tube voltage during the Low Dose Computed Tomography(LDCT). Materials and Methods: With the image reconstruction method as basis, Chest Phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of Tube Voltage (100kVp, 120kVp). For image evaluation, Back ground noise, Signal to Noise ratio(SNR) and Contrast to Noise ratio(CNR) were measured, and, for dose evaluation, CTDIvol and DLP were measured respectively. The statistical analysis was tested with SPSS(ver. 22.0), followed by ANOVA Test conducted after normality test and homogeneity test. (p<0.05). Results: In terms of image evaluation, there was no outstanding difference in Ascending Aorta(AA) SNR and Infraspinatus Muscle(IM) SNR with the different values of ASIR application(p<0.05), but a significant difference with the different amount of tube voltage(p>0.05). Also, there wasn't noticeable change in CNR with ASIR and different amount of Tube Voltage (p<0.05). However, in terms of dose evaluation, CTDIvol and DLP showed contrasting results(p<0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120kVp were 2.6mGy with No-ASIR and 2.17mGy with 20%-ASIR respectively, decreased by 0.43mGy, and the values with 100kVp were 1.61mGy with No-ASIR and 1.34mGy with 20%-ASIR, decreased by 0.27mGy. In terms of DLP, the measured values with 120kVp were $103.21mGy{\cdot}cm$ with No-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$(about 16.7%), and the values with 100kVp were $63.84mGy{\cdot}cm$ with No-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$(about 16.7%). Conclusion: At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise. For the future, through the result of the experiment, it is considered that the method above would be recommended for follow-up patients or those who get health checkup as long as there is no interference on the process of diagnosis due to the characteristics of Low Dose examination.

  • PDF

Pharmacological Characterization of KR-31125, a Novel Nonpeptide AT1 Receptor Antagonist (안지오텐신 수용체 길항제 KR-31125의 특성에 관한 연구)

  • Lee, Sung-Hou
    • Journal of Life Science
    • /
    • v.20 no.6
    • /
    • pp.831-837
    • /
    • 2010
  • KR-31125 (2-butyl-5-dimethoxymethyl-6-phenyl-7-methyl-3-[[2'-(1H-tetrazol-5-yl)biphenyl-4-yl]methyl]-3H-imidazo[4,5-b]pyridine) is a potent inhibitor of angiotensin II type 1 ($AT_1$) receptors in human recombinant $AT_1$ receptors and rabbit aorta. These in vitro studies revealed that KR-31125 inhibited specific [$^{125}I$] [$Sar^1$, $Ile^8$]-angiotensin II binding to human recombinant $AT_1$ receptors in a concentration dependent manner with an $IC_{50}$ value of $19.72{\pm}2.65$ nM. However, no interaction with $AT_2$ receptors was detected as displayed by the competition binding of [$^{125}I$] CGP 42112A to human recombinant $AT_2$ receptor. The binding action was also confirmed as a competitive mode that was identical to the previously studied compound, losartan. In addition, KR-31125 caused a nonparallel shift to the right in the concentration response curves to angiotensin II with a 30-80% decrease in the maximum contractile responses ($pK_B$: 7.63). Compared to the previous studies with losartan that showed a parallel right shift in the maximum contractile responses to AII ($pA_2$: 7.59), KR-31125 presented a different mode of action with a similar potency to losartan. These results demonstrate that KR-31125 is a highly potent and $AT_1$ selective angiotensin II receptor antagonist that can be applied to the fields of new diagnostic and research tools with upcoming in vivo study results.

The Clinical Results of Open Heart Surgery with Coronary Artery Bypass Grafting (관상동맥 우회로 조성수술을 병행한 개심수술의 임상성적)

  • 유경종;강면식
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.171-176
    • /
    • 1996
  • From March, 1983 to June, 1994, twenty-two patients underwent coronary artery and combined operations. The ages of the patients ranged from 42 years to 72 years (mean 60.4$\pm$8.2 years). There were 17 male and 5 female patients. The left ventricular (LV) ejection fraction ranged from 25% to 65% (mean 46.9$\pm$14.2%). Nine patients had mechanical complication of myocardial infarction (MI), of which 5 were LV aneurysm, 3 ventricular septal defect and 1 mitral regurgitation. Nine patients had rheumatic valvular heart disease of whom 7 with aortic valve disease and 2 with mitral valve disease. Two other patients had left atrial thrombi, only one with atrial septal defect a d another with aneurysm of ascending aorta. An average of 2.1$\pm$1.0 bypasses was done, ranging from one to four. There were 3 postoperative complications; 2 perioperative MI and 1 leg wound infection. Among complicated patients, mortality was 1 patient (4.5%) due to low cardiac output syndrome after perioperative MI. With 3 to 136 months follow-up (mean 41.1$\pm$40.2 months), late mortality was 1 patient due to cerebral vascular accident. Among long-term survivors, all patients are in New York Heart Association functional class I or II. Although the number of patients was small, our surgical results were favorable. Therefore we think that coronary revascularization combined with heart operation does not increase the operative risk when associated coronary artery disease is present, and it reduces the occurrence of late death.

  • PDF