• Title/Summary/Keyword: Antifreezing solution

Search Result 5, Processing Time 0.025 seconds

Frost Prevention of Fin-Tube Heat Exchanger by Spreading Antifreezing Solution (부동액 도포에 의한 핀-튜브 열교환기 착상방지)

  • Oh, Sang-Youp;Chang, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.6
    • /
    • pp.477-485
    • /
    • 2006
  • A study on frost prevention of fin-tube heat exchanger is experimently performed by spreading antifreezing solution on heat exchanger surface. It is desirable that the antifreezing solution spreads completely on the surface forming thin liquid film to prevent frost nucleation and crystal growth and to reduce the thermal resistance across the liquid film. A small amount of antifreezing solution falls in drops on heat exchanger surface using two types of supplying devices, and a porous layer coating technique is adopted to enhance the wettedness of antifreezing solution on the surface. It is observed that the antifreezing solution liquid film prevents fin-tube heat exchanger from frosting, and heat transfer performance does not degrade through the frosting tests. The concentration of supplied antifreezing solution can be determined by heat transfer analysis of the first row of heat exchanger to avoid antifreezing solution freezing due to dilution by moisture absorption.

An Experimental Study on the Frost Prevention using Micro Liquid Film of an Antifreezing Solution (마이크로 부동액막을 이용한 착상방지에 관한 실험적 연구)

  • Chang Young- Soo;Yun Won -Nam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.459-467
    • /
    • 2005
  • The effect of anti freezing solution liquid film on the frost prevention is experimentally investigated. It is desirable that the antifreezing solution spreads widely on the heat exchanger surface forming thin liquid film to prevent frost nucleation and reduce the thermal resistance across the film. A porous layer coating technique is adopted to improve the wettedness of the anti freezing solution on a parallel plate heat exchanger. The antifreezing solution spreads widely on the heat exchanger surface with 100 $\mu$m thickness by the capillary force resulting from the porous structure. It is observed that the antifreezing solution liquid film prevents a parallel plate heat exchanger from frosting. The reductions of heat and mass transfer rate caused by thin liquid film are only $1\~2\%$ compared with those for non-liquid film surface.

Experimental Study of Freezing Characteristics and Antifreezing Method of Liquid Additive for Early Strength (액상형 조강제의 동결특성 및 동결방지 방안에 관한 실험적 고찰)

  • Lee, Mun-Hwan;Ryu, Deug-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.647-653
    • /
    • 2007
  • In ready mixed concrete factory, in case of using the high molecular additive in winter especially the liquid additive for the early strength, it is required to check the stability. In this research, the freezing and gelling characteristics of the liquid additive for the early strength is reviewed, the material and mechanical solution are proposed to that the practical quality control method will be suggested. As the result, the Freezing temperature of the liquid additive for the early strength is $-11.8^{\circ}C$, and it is the lower than the temperature at which the strength is shown. By making with sodium silicate of $37{\pm}0.5%$ designed by $SiO_2\;and\;Na_2O$ in 0.31 of mol ratio, it minimizes the gelling at the lower temperature. On the other hand, facilities for storing and supplying the material should be set at $40^{\circ}C$ so the temperature distribution is well spreaded for practical operation.

A Study on the Development of a High Resolution Snow Gauge (정밀 강설량계 개발을 위한 연구)

  • Lee, Bu-Yong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.8 no.4
    • /
    • pp.270-274
    • /
    • 2006
  • This study proposes a new method for automatic recording of snowfall by a mass unit which is required in weather forecast and hydrology research. In this method the weight of a buoyancy bar submerged in a liquid is measured by a strain-gauge loadcell. Field test results of the strain-gauge loadcell showed good stability as well as high accuracy. Indoor tests of the instrument using a large tank of 120 cm diameter and 25 cm height connected to a small tank measured the liquid level with a good stability, showing a measurement error of less than 0.1 mm in a 100 mm range. This method of water depth measurement is very useful in measuring snowfall because it has no limitation on the funnel size of the instrument. In addition, an antifreezing solution instead of water used in the tank makes a heating system for melting snow unnecessary.