• Title/Summary/Keyword: Antifreeze

Search Result 73, Processing Time 0.023 seconds

Growth of Ice Crystal with Concentration of Surfactant in Water Solution (계면활성제 농도가 빙결정의 입자크기에 미치는 영향)

  • ;稻葉英男
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.2
    • /
    • pp.240-247
    • /
    • 2002
  • Recently, a thermal energy storage system has been developed actively fur the purpose of saving energy and reducing the peak electrical demand. Especially, ice slurry is a promising working fluid for low temperature energy storage systems. A flow of ice crystals has a large cooling capacity as a result of the involvement of latent heat. However, there are still problems related to the recrystallization of ice crystals for realizing long term storage and long distance transportation. To find improvements fur this, a method for the creation of ice crystals resistant to recrystallization has been proposed and researched by the use of an antifreeze protein (AFP) solution etc. In the present study, it has been investigated the growth of ice crystal in several kinds of water solution added non-ionic surfactant. The results shows that size of ice crystal was smaller with increasing in added surfactant. And ice crystal was not increased with added surfactant.

An Experimental Study on the Performance of a Freeze-Protected Direct Solar Water Heating System (비동파 직접식 온수 급탕 시스템의 열성능에 관한 연구)

  • Chun, W.G.;Kim, H.T.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.33-38
    • /
    • 1998
  • This paper reports the experimental results concerning the thermal performance of a freeze-protected direct solar water heating system. The direct system tested has been manufactured to prevent any breakage during harsh wintry conditions by specially designed riser and downcomer headers capable of relieving extra pressure due to freezing of water. The direct system tested has shown 10% improvement in its efficiency over that of a indirect type system using antifreeze as the heat transfer medium. It is felt that any direct system of its kind could galvanize the whole solar industry if further improvements are made to ensure its durability.

  • PDF

Effect of Coolant on PEMFC Performance in Low Humidification Condition (저가습 조건에서 냉각 유체의 고분자전해질 연료전지에 대한 영향)

  • Lee, Hung-Joo;Song, Hyun-Do;Kwon, Jun-Taek;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.25-30
    • /
    • 2007
  • Proton exchange membrane fuel cell(PEMFC) performance could be affected by various factors such as cell temperature, total pressure, partial pressure of reactants and relative humidity. Hydrogen ion is combined with water to form hydronium ion [$H_3O^+$] and pass through membrane resulting electricity generation. Cooling system is needed to remove heat and other uses on large scale fuel cell. In case that collant conductivity is increased, fuel cell performance could be decreased because produced electricity could be leaked through coolant. In this study, triple distilled water(TDW) and antifreeze solution containing ethylene glycol was used to observe resistance change. Resistance of TDW was taken 28 days to reach preset value, and effect on fuel cell operation was not observed. Resistance of antifreeze solution was not reached to preset value up to 48 days, but performance failure occurred presumably caused by bipolar plate junction resulting stoppage resistance experiment. Generally PEMFC humidification is performed near-saturated operating conditions at various temperatures and pressures, but non-humidifying condition could be applied in small scale fuel cell to improve efficiency and reduce system cost. However, it was difficult to operate large scale fuel cell without humidifying, especially higher than $50{\sim}60^{\circ}C$. In case of small flux such as 0.78 L/min, temperature difference between inlet and outlet was occurred larger than other cases resulting performance decrease. Non-humidifying performance experiments were done at various cell temperature. When both of anode and cathode humidification were removed, cell performance was strongly depended on cell operating temperature.

Production of Levulinic Acid from Gelidium amansii Using Two Step Acid Hydrolysis (우뭇가사리로부터 레불린산 생산공정을 위한 2단 산 가수분해)

  • Kim, Jun Seok
    • Korean Chemical Engineering Research
    • /
    • v.51 no.4
    • /
    • pp.438-442
    • /
    • 2013
  • The study of bioproduct production from inexpensive biomass such as marine biomass has recently attracted considerable attention. Because, marine biomass which compared to land biomass, it can be grown rapidly and is easily cultivated without the need for expensive equipment. In addition, the carbohydrate contents are similar or higher than land biomass such as woody biomass and can be easily converted to chemicals through proper chemical processes. In the production of various biochemicals from marine biomass, levulinic acid is a highly versatile chemical with numerous industrial uses and has the potential to become a commodity chemical. It can be used as a raw material for resins, plasticizers, textiles, animal feed, coatings and antifreeze. In this study, experiments were carried out to determine the optimum conditions of temperature, acid concentration and reaction time for production of levulinic acid from marine biomass, Gelidium amansii, using two-step treatment. In the first hydrolysis step, solid-state cellulose which was used to produce ethanol by fermentation and liquid-state galactose which used to produce bioproduct such as levulinic aicd were obtained through acid soaking. In the second hydrolysis step, the liquid-state galactose was converted into levulinic acid via a high-temperature reaction in a batch reactor. As a result, the overall production yield of Gelidium amansii to levulinic acid in the two-step acid hydrolysis was approximately 20.6% on the initial biomass basis.

Treatment of Ethylene Glycol Poisoning Patient Presented with Mental Change (의식저하로 내원한 에틸렌 글리콜 중독 환자 1례)

  • Min Jin Hong;Lee Jang Young;Min Moon Gi;Chung Sung Pil;Kim Seung Whan;Yoo In Sool
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.2 no.2
    • /
    • pp.129-132
    • /
    • 2004
  • Ethylene glycol poisoning can cause profound morbidity and is almost universally fatal if untreated. Central nervous system depression, pulmonary edema, and acute oligulic renal failure with crystalluria are among the most commonly encountered complication of ingestion. Ingestion of ethylene glycol may be an important contributor in patients with metabolic acidosis and subsequent renal failure. The diagnosis of ethylene glycol poisoning is based on nonspecific clinical symptoms and signs and indirect and direct laboratory measurement of ethylene glycol. As a result, diagnosis and treatment sometimes can be delayed. We describe 52-year-old man who visited to emergency department with mental change of unknown origin. The patient has high anion gap metabolic acidosis and renal failure due to ingestion of antifreeze that contained ethylene glycol. We used hemodialysis for elimination technique. The patient was discharged with minimal complication.

  • PDF

The Performance Simulation of All-Glass Vacuum Tubes with Coaxial Fluid Conduit (등축 유로를 가진 이중진공관형 태양열 집열기의 열성능에 관한 시뮬레이션 연구)

  • Lee, Sang-Jin;Hyun, Myung-Taek;Park, Youn-Cheol;Chun, Won-Gee;Lee, Jung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.3
    • /
    • pp.27-38
    • /
    • 2004
  • A numerical investigation has been carried out for a solar system, which consists of all glass solar vacuum tubes Water is heated as it flows through the coaxial fluid conduit inserted in each tube. The space between the exterior of the fluid conduit and the glass tube is filled with antifreeze solution. This is to facilitate heat transfer from the solar heated absorber surface to water and to prevent the functional problems due to freezing in frigid weather conditions. A one-dimensional steady state model is fully described which will be used to develop three-dimensional model using STAR-CD. These models could be used efficiently in designing all-glass solar collector tubes with different geometrical parameters other than those considered in the present analysis. Results show good agreement when compared with other experimental data demonstrating the reliability of the present model.

A Numerical Study on the Thermal Characteristics of Double Skin Vacuum Tubes with Coaxial Fluid Conduit (등축 유로 장착 이중 태양열 진공관의 열적 특성에 관한 수치해석적 연구)

  • Hyun, Jun-Ho;Park, Youn-Cheol;Chun, Won-Gee;Lee, Sang-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.567-570
    • /
    • 2006
  • A numerical study has been carried out for a solar water heater which consists of double skin solar vacuum tubes. Water is heated as it flows through the coaxial fluid conduit inserted in each tube. The space between the exterior of the fluid conduit and the glass tube is tilled with antifreeze solution. This is to facilitate heat transfer from the solar heated absorber surface to water and to prevent the functional problems due to freezing in frigid weather conditions. A one-dimensional steady state model is fully described which will be used to develop three-dimensional model using STAR-CD. These models could be used efficiently in designing double skin solar collector tubes with different geometrical parameters other than those considered in the present analysis. Results show a good agreement when compared with other experimental data demonstrating the reliability of the one-dimensional model employed.

  • PDF

Device Development of Mixture Concentration of Ethylene Glycol Antifreeze Coolant for Vehicles (자동차 에틸렌글리콜 부동액의 혼합 농도 측정 장치 개발)

  • Lee, Dae-Woong;Lee, Eun-Woung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.331-336
    • /
    • 2016
  • This study presents a coolant density calculation device and its corresponding method by using a mass flowmeter and the LabVIEW program. The method can be easily measured with a mixture of coolant and by calculating the percentage of ethylene-glycol without additional investment. The cooling water is very important in a vehicle to protect the engine, and the cooling performance is affected by the mixture concentration and coolant density. The coolant density calculation device measures the mixed concentration in the anti-freeze cooling mixture made from distilled water and ethylene-glycol in real time with the mass flowmeter that is commonly attached to the radiator or heater core. The calculation program for the mixture concentration percentage was developed using the LabVIEW software. The correlation between experimental results and the calculation was conducted for a range of temperature from 40 to $90^{\circ}C$ and by varying the mixture ratio of distilled water and ethylene-glycol. As a result, the anti-freeze coolant concentration in the volume percentage is able to monitor the coolant density in a timely basis by implementing a mixture concentration calculation program without the need for additional equipment investment. The results of the calculation for the mixture concentration level show a maximum 2.7% deviation compared to the experimental results.

Regulation of Unfolded Protein Response by Ethylene Glycol in Rat (Rat에서 ethylene glycol에 unfolded protein response의 조절)

  • Lee, Eun Ryeong;Kwon, Kisang
    • Journal of Life Science
    • /
    • v.23 no.9
    • /
    • pp.1104-1108
    • /
    • 2013
  • Ethylene glycol (EG) is the most commonly used for automotive antifreeze, and it's easily misuseful for human. EG poisoning occurs in suicide attempts and infrequently, either intentionally through misuse or accidentally because of sweet taste. Though EG itself is mild toxic to the human body, it becomes higher toxic organic acids by in vivo broken down that are responsible for extensive cellular damage in various tissues caused principally by the metabolites. It is already well known that various cellular stresses induce gene expression of endoplasmic reticulum (ER) chaperones and ER stress sensors. This study demonstrated that regulation of gene expression of ER chaperones and ER stress sensors was induced by EG in rat tissues, and in tissues histological changes are also detected by both staining H&E and immunofluorescent.

A Modified Cryopreservation Method of Psychrophilic Chlorophyta Pyramimonas sp. from Antarctica

  • Hong, Sung-Soo;Lee, Soo-Young;Kim, Young-Nam;Kang, Sung-Ho;Kim, Hak-Jun
    • Ocean and Polar Research
    • /
    • v.33 no.3
    • /
    • pp.303-308
    • /
    • 2011
  • Polar psychrophiles which thrive under extreme conditions such as cold temperature, high salinity, and high dose ultraviolet light, emerge as novel targets for biotechnology. To prevent genetic drift and the possibility of contamination by subculturing, cryopreservation was employed for two psychrophilic microalgae, Porosira sp. (KOPRI AnM0008) and Pyramimonas sp. (KOPRI AnM0046), which have anti-freeze activities. Five cryoprotectants (dimethyl sulphoxide, ethylene glycol, glycerol, methanol and propylene glycol) showed toxicity at 20-30% (v/v). The optimal cryoprotectant concentration and equilibration time were less than 20% and 10 min, respectively. Cryopreservation was carried out in the presence of cryoprotectants either by direct freezing in liquid nitrogen ($LN_2$) or controlled freezing using a controlled rate freezer followed by storage in the $LN_2$ tank. As a result, Pyramimonas sp. (KOPRI AnM0046), a psychrophilic chlorophyta was revived. Cryopreserved Porosira sp. was not revived from either freezing protocols probably due to the silicic cell wall and its relatively large cell size. In the case of Pyramimonas sp. (KOPRI AnM0046), the controlled freezing method showed higher revival yield than the direct freezing method.