• 제목/요약/키워드: Anti-vortex

검색결과 42건 처리시간 0.022초

Experimental Study on the Film Cooling Effectiveness on a Flat Plate with Anti-Vortex Holes

  • Park, Soon Sang;Park, Jung Shin;Kwak, Jae Su
    • International Journal of Aerospace System Engineering
    • /
    • 제1권1호
    • /
    • pp.1-9
    • /
    • 2014
  • In this paper, the effects of the anti-vortex hole angle and blowing ratio on the flat plate film cooling effectiveness were experimentally investigated. For the film cooling effectiveness measurement, pressure sensitive paint technique was applied. The experiments were conducted for cylindrical and anti-vortex film cooling holes, and three blowing ratios of 0.25, 0.5, and 1.0 were tested. Two anti-vortex hole angles of 0 and 15 degree with respect to the flow direction were considered. For the cylindrical hole case, the film cooling effectiveness decreased as the blowing ratio increased because of the coolant lift-off. For the angle anti-vortex hole cases, however, higher blowing ratio resulted in higher film cooling effectiveness due to the reduced actual blowing ratio and diminished kidney vortex. For all blowing ratio, the angled anti-vortex hole case showed the highest film cooling effectiveness.

반와류 홀의 각도가 평판의 막냉각 효율에 미치는 영향 연구 (Effect of Anti-Vortex Hole Angle on the Flat Plate Film Cooling Effectiveness)

  • 박순상;박정신;이상훈;문영기;곽재수
    • 한국유체기계학회 논문집
    • /
    • 제17권5호
    • /
    • pp.5-10
    • /
    • 2014
  • In this paper, the experimental study was carried to investigate the effect of angle of the anti-vortex holes on the film cooling effectiveness on a flat plate. The pressure sensitive paint technique was applied to measure the film cooling effectiveness. Two anti-vortex hole angles of $0^{\circ}$ and $15^{\circ}$ with respect to the primary hole were considered, and the simple cylindrical hole case was also tested. The blowing ratio based on the cylindrical hole was 0.5 and the same flow rate was kept for all anti-vortex hole cases. Results showed that the film cooling effectiveness for the anti-vortex hole cases were much higher than that of the cylindrical case. Among the anti-vortex hole cases, $15^{\circ}$ angle anti-vortex hole case showed higher film cooling effectiveness than that by the $0^{\circ}$ angle anti-vortex hole case.

반와류 홀의 형상 변화가 막냉각 효율에 미치는 영향 (Effects of Geometry of Anti-Vortex Holes on Film-Cooling Effectiveness)

  • 김준희;김선민;김광용
    • 한국유체기계학회 논문집
    • /
    • 제17권2호
    • /
    • pp.12-23
    • /
    • 2014
  • A parametric study on anti-vortex holes for turbine blade cooling was investigated numerically. Three-dimensional Reynolds-averaged Navier-Stokes equations and shear stress transport turbulence model were used for analysis of anti-vortex film cooling. Validation of numerical results was carried out comparing with experimental data. The cooling performance of anti-vortex holes was assessed by two geometric variables, the ratio of diameters of holes and the lateral distances between the primary hole and anti-vortex hole at blowing ratios of 0.5 and 1.0. The results showed that the spatially-averaged film-cooling effectiveness increases as the ratio of the diameters increases and the distance between the primary hole and anti-vortex hole decreases.

수리구조 개선을 통한 다중 펌프 흡수정에서 발생하는 보텍스 방지 대책 수립에 관한 연구 (Modifications to Hydraulic Structures for Anti-submerged Vortex in a Multi Pump Intake using CFD simulation Technique)

  • 박노석;김성수;정우창;김종오
    • 상하수도학회지
    • /
    • 제25권1호
    • /
    • pp.31-39
    • /
    • 2011
  • In order to suggest the methodology for achieving anti-vortex device within multi pump intake well, CFD(Computational Fluid Dynamics) simulation were conducted for two alternative suggestions. Multi-intake sump model with anti-vortex device basins were designed and the characteristics of submerged vortex were investigated in the flow field by numerical simulation. From the results of simulations, to install the horizontal plate and vertical cross plates within basins were effective for preventing air-induction vortex.

다중 흡수정을 갖는 펌프장 모델의 유동균일성 해석 (Numerical Analysis on the Flow Uniformity in a Pump Sump Model with Multi Pump Intake)

  • 최종웅;최영도;임우섭;이영호
    • 한국유체기계학회 논문집
    • /
    • 제12권4호
    • /
    • pp.14-22
    • /
    • 2009
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite basin with no close walls or floors and with no stray currents. Therefore, flow into the pump intake is with no vortices or swirling. However, pump station designers relying on these curves to define the operating conditions for the pump selected sometimes meet the reductions of capacity and efficiency, as well as the increase of vibration and additional noise, which were caused by air-entered flow in the pump station. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump of pump station model. Multi-intake sump model with anti-submerged vortex device basin is designed and the characteristics of submerged vortex is investigated in the flow field by numerical simulation. In this study, a commercial CFD code is used to predict the vortex generation in the pump station accurately. The analysed results by CFD show that the vortex structure and effect of anti-submerged vortex device are different at each pump intake channel.

산화제 탱크의 와류방지장치 유동해석 (Numerical Flow Analysis for Anti-Vortex Device (AVD) in Oxidizer Tank)

  • 장제선;한상엽;길경섭;조인현
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.168-175
    • /
    • 2010
  • 우주발사체용 액체추진제 공급시스템에서 산화제가 엔진으로 공급될 때 다양한 환경 또는 외력에 의해서 탱크 내부의 출구영역에서 와류가 발생한다. 이러한 swirl을 방지하기 위한 탱크 내부에 AVD(Anti-Device Vortex)라는 와류방지 장치를 설치한다. 유동해석을 통해 LOX(액체산소) 공급에 효율적인 와류방지장치의 성능을 확인하였다. AVD 개수와 길이에 따라 공급시간에 대한 질유량과 산화제 자유표면에서 swirl의 크기 등을 분석해서 최적의 크기와 개수를 도출하고 설계에 반영하고자 한다.

대형석탄화력발전용 보일러 관군의 Anti-Noise Baffle 설치에 따른 음향공진 (Acoustic resonance by Inserting Anti-noise Baffle in the Tube Bank of Boiler of a Large Fossil Power Plant)

  • 방경보;김철홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.178-183
    • /
    • 2004
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a large fossil power plant. The phenomena of acoustic resonance may arise when the vortex shedding frequency coincides with the acoustic natural frequency. In this system dominant frequency of vibration and noise was 37.5Hz. The $3^{rd}$ acoustic natural frequency calculated was 37.2 Hz. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}20%$, acoustic resonance could occur. If system is the state of acoustic resonance, vibration and noise become large. In order to prevent acoustic resonance, anti-noise baffle should be installed in the tube bank. In the case of installing baffle, we should consider the number of baffle and the effect of acoustic mode due to baffle extension length. To do this, we did acoustic mode analysis. After installing anti-noise baffle, acoustic resonance was disappeared and vibration magnitude and noise level was reduced dramatically.

  • PDF

CFD에 의한 와류방지장치(AVD)가 설치된 흡수정내 펌프의 성능평가에 관한 연구 (Study on Performance Analysis of Pump within Sump Model with AVD installation by CFD)

  • 최종웅;박노석;김성수;박상수;이영호
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.463-469
    • /
    • 2012
  • The efficiency of the flow mixed pump installed within the bell-mouth in the sump is reduced by the flow characteristics of around intakes. Strong submerged vorticies can be successfully suppressed by installing an AVD(anti-submerged vortex device) on the bottom of pump intake channel just below the bell-mouth. Sump model with AVD device basin is designed and the characteristics of submerged vortex is investigated in the flow field by numerical simulation. In this study, a commercial CFD code is used to predict the efficiency of the pump with the AVD installation in the pump station accurately.

AN INVESTIGATION OF SURFACE VORTICES BEHAVIOR IN PUMP SUMP

  • Kang, Won-Tae;Shin, Byeong-Rog
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.592-595
    • /
    • 2011
  • A numerical investigation on a suction vortices, free vortices and subsurface vortices behavior in the model sump system with multi-intakes is performed A test model sump and piping system were designed based on Froude similitude for the prototype of the recommended structure layout by HI-9.B Standard for Pump Intake Design of the Hydraulic Institute. A numerical analysis of three dimensional multiphase flows through the model sump is performed by using the finite volume method of the CFX code with multi-block structured grid systems. A ${\kappa}-{\omega]$ ShearStressTransportturbulencemodelandthe Rayleigh-Plesset cavitation model are used for solving turbulence cavitating flow. From the numerical analysis, several types of vortices are reproduced and their formation, growing shedding and detailed vortex structures are investigated. To reduce abnormal vortices, an anti-vortex device is considered and its effect is investigated and discussed.

  • PDF

수리실험을 이용한 발전소의 순환수 취수부 흡입수조의 와류저감에 관한 연구 (On Vortex Reduction Characteristics of Pump Sump Circulating Water Intake Basin of Power Plant Using Hydraulic Experiment)

  • 엄중현;이두한;김형수
    • 대한토목학회논문집
    • /
    • 제42권6호
    • /
    • pp.815-824
    • /
    • 2022
  • 발전소의 주요시설 중 발전 시스템 냉각용으로 사용되는 순환수는 순환수 취수부(Circulation Water Intake Basin)를 통해 공급된다. 순환수 취수부 중 흡입수조(Pump Sump)에서 발생하는 다양한 형태의 와류는 순환수펌프(Circulation Water Pump) 및 관로에 악영향을 미친다. 특히, 공기의 흡입을 동반한 자유표면 와류는 진동, 소음, 공동현상 등을 발생시켜 순환수펌프의 성능 저하, 관로의 손상을 일으키며 발전이 중단되는 주요 원인이 된다. 따라서 수리모형 실험을 통해 순환수 취수부에 대한 수리특성을 반드시 확인하고, 와류 발생 시 와류를 제어할 수 있는 적절한 와류제어장치(Anti Vortex Device)를 적용하여 원활한 발전소 운영이 가능하도록 해야 한다. 자유표면 와류 저감을 위해 와류제어장치 중커튼월(Curtain Wall)을 사용하는 것이 일반적이며, 자세한 내용은 American National Standard for Pump Intake Design에서 기술하고 있다. 본 연구에서는 리비아 Tripoli West 4×350 MW 발전소의 순환수 취수부를 대상으로 하였으며, 실제 운영조건을 적용하고, 수리모형 실험을 통해 순환수 취수부 중 흡입수조에서 발생하는 와류제어장치의 와류저감 효과를 분석하였다. 또한, 수중와류 제어를 위해 플로어 스플리터(floor splitter)는 기본적으로 적용하였고, 자유표면에서 발생하는 와류제어를 위해 새로운 형태인 컬럼 커튼월(Column Curtain Wall)을 추가적으로 적용하여 효과를 확인하였다. 본 연구에서는 일반적으로 적용되었던 커튼월에 새로 개발한 컬럼 커튼월을 추가적으로 적용하여 수리특성을 분석한 결과, 균일한 흐름이 형성되면서 와류가 제어되는 것을 확인하였다. 또한, 순환수펌프 관로 내에서 발생하는 와류각도는 ANSI/HI 9.8의 설계기준인 5° 이하로 나타나 흐름의 안정성을 확인하였다.