• Title/Summary/Keyword: Anti-resonant Frequency

Search Result 26, Processing Time 0.026 seconds

Development of the Anti-Start Air Conditioner Compressor Resonant DC/DC Converter for Commercial Vehicle (상용차를 위한 무시동 에어컨 압축기용 공진형 DC/DC 컨버터 개발)

  • Han, Keun-Woo;Kim, Seong-Gon;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.557-563
    • /
    • 2014
  • This study deals with a resonant converter of an anti-start air conditioner compressor for commercial vehicles. The anti-start air conditioner compressor must generally have a high current, high efficiency, a low volume, and a low weight. To reduce the switching losses and voltage and current stresses of the device, the anti-start air conditioner compressor applies the full-bridge L-C resonant converter topology. Hardware parameters are designed to have a wide voltage range, and the switching frequency range of the L-C resonant converter is determined. Simulation is implemented using PSIM and an experiment is performed to verify the proposed converter.

Backlash Estimation of a Seeker Gimbal with Two-Stage Gear Reducers (2 단 기어 감속기를 갖는 탐색기 짐발의 백래시 추정)

  • Baek, Joo-Hyun;Hong, Sung-Min;Kwak, Yoon-Keun;Kim, Soo-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.10
    • /
    • pp.2130-2141
    • /
    • 2002
  • A unique technique to estimate the magnitude or contribution ratio of each stage backlash in a system with a two-stage gear reducer is proposed. The concept to estimate the magnitude or contribution ratio of each stage backlash is based on the change of frequency response characteristic, in particular, the change of anti-resonant frequency and resonant frequency, due to the change of each stage backlash magnitude, even though the total backlash magnitude of a system with a two-stage gear reducer is constant. The validity of the technique is verified in a seeker gimbal and satisfactory results are obtained. It is thought that the diagnosis and maintenance of the manufacturing machines and systems with two-stage gear reducers will become more efficient and economical by virtue of the proposed technique.

A Novel Control Scheme for T-Type Three-Level SSG Converters Using Adaptive PR Controller with a Variable Frequency Resonant PLL

  • Lin, Zhenjun;Huang, Shenghua;Wan, Shanming
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1176-1189
    • /
    • 2016
  • In this paper, a novel quasi-direct power control (Q-DPC) scheme based on a resonant frequency adaptive proportional-resonant (PR) current controller with a variable frequency resonant phase locked loop (RPLL) is proposed, which can achieve a fast power response with a unity power factor. It can also adapt to variations of the generator frequency in T-type Three-level shaft synchronous generator (SSG) converters. The PR controller under the static α-β frame is designed to track ac signals and to avert the strong cross coupling under the rotating d-q frame. The fundamental frequency can be precisely acquired by a RPLL from the generator terminal voltage which is distorted by harmonics. Thus, the resonant frequency of the PR controller can be confirmed exactly with optimized performance. Based on an instantaneous power balance, the load power feed-forward is added to the power command to improve the anti-disturbance performance of the dc-link. Simulations based on MATLAB/Simulink and experimental results obtained from a 75kW prototype validate the correctness and effectiveness of the proposed control scheme.

A Novel Anti-Islanding Method for Utility Interconnection of Distributed Power Generation Systems

  • In-Ho
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.4
    • /
    • pp.217-224
    • /
    • 2004
  • A novel anti-islanding method for the distributed power generation system (DPGS) is proposed in this paper. Three different islanding scenarios are explored and presented based on the analysis of real and reactive power mismatch. It is shown via investigation that islanding voltage is a function of real power alone, where its frequency is a function of both real and reactive power. Following this analysis, a robust anti-islanding algorithm is developed. The proposed algorithm continuously perturbs ($\pm$5%) the reactive power supplied by the DPGS while simultaneously monitoring the utility voltage and frequency. In the event of islanding, a measurable frequency deviation takes place, upon which the real power of the DPGS is further reduced to 80%. A drop in voltage positively confirms islanding and the DPGS is then safely disconnected. This method of control is shown to be robust: it is able to detect islanding under resonant loads and is also fast acting (operable in one cycle). Possible islanding conditions are simulated and verified through analysis. Experimental results on a 0.5kW fuel cell system connected to a utility grid are discussed.

Estimation of Characteristics Change on Transverse Mode PZT Vibrator Under Space Environment (우주환경하에서 횡진동 모드 PZT진동자의 특성변화 예측)

  • Lee, Sang Hoon;Moon, Guee Won;Yoo, Seong Yeon;Kim, Jung Soon;Kim, Moo Joon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.8
    • /
    • pp.514-522
    • /
    • 2012
  • The temperature dependence of the characteristics in a PZT-5 piezoelectric ceramic vibrator with the transverse mode was investigated in the range of $-100^{\circ}C$ to $90^{\circ}C$ using a thermal vacuum chamber to utilize the vibrator in aerospace industries. As the results, at room temperature, the resonant and anti-resonant frequencies had the minimum value, whereas, the dielectric constant increased linearly from about 2500 to 7500 in the given temperature range. The mechanical loss decreased linearly from 0.08 to 0.03. Through the regression analysis, the temperature dependence functions of the characteristics were derived to linear and square regression functions. Applying the functions, the input admittance characteristics of the piezoelectric vibrator were calculated, and the results showed good agreement with measured ones. It can be confirmed that this method is useful to estimate the characteristics change of the piezoelectric vibrator caused by the temperature change under the space environment.

Piezoelectric immunosensor for the detection of Edwardsiellosis

  • Hong, Sung-Rok;Choi, Suk-Jung;Jeong, Hyun-Do;Hong, Su-Hee
    • Journal of fish pathology
    • /
    • v.20 no.3
    • /
    • pp.307-313
    • /
    • 2007
  • In this study, a QCM biosensor was made to detect Edwardsiella tarda (E. tarda) using a specific antibody. A 9 MHz AT-cut piezoelectric wafer layered with two gold electrodes of 5mm diameter had a reproducibility of 0.1 Hz in frequency response and was used as the transducer of the QCM biosensor. Self assembled layer (SAM) was conformed on a quartz crystal by treating with 3-mer-captopropionic acid (MPA) and activated with N-ethyl-N'-(3-dimethyl-aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The resulting NHS group was further converted to hydrazide by the reaction with hydrazine. Aldehyde group was introduced into the carbohydrate moiety of anti-E. tarda antibody by the reaction with periodic acid and was used to immobilise the antibody through the reaction with hydrazide group on the electrode surface. A baseline was established in the presence of phosphate-buffered saline (PBS) and a resonant frequency (F1) was measured. Sample was added to the sensor surface and second resonant frequency (F2) was measured after unbound substances were washed out with PBS several times. Finally, the frequency shift (ΔF) representing the mass change was calculated by subtracting F2 from F1. After adding the oxidized anti-E. tarda antibody to the electrode surface containing hydrazide group, frequency shift of 288.811.4 Hz (mean S.E) was observed, thus proving that considerable amount of antibody was immobilized. In the immunoassay test, the frequency shift of 1877.75 Hz, 580.67 Hz, 221.39 Hz, 7.671.83 Hz (mean S.E) were observed at doses of 1000, 500, 100, 50 g of bacterial cells, respectively. It was also demonstrated that the prepared sensor chip was stable enough to withstand repeated surface regeneration with 0.2 M Tris-glycine and 1 % DMSO, pH 2.3 more than ten times.

Development of 1-3 Piezo-Composites made by the method of "Dice & Fill" and Estimation of Their Piezoelectric Characteristics (Dice & Fill 방식을 이용한 1-3 복합재 압전진동자 개발 및 압전특성 평가)

  • 김영덕;정우철;김광일;김흥락;김동수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.869-872
    • /
    • 2000
  • The aim of present work was to fabricate the piezoelectric composite materials of low megahertz applications such as non-destructive testing of materials. Among all the various composites, those with PZT rods embedded in Spurrs epoxy with regular periodicity (1-3 connectivity) was fabricated by dice and fill method. The fabricated size of the PZT cell were 0.18X0.18, 0.28X0.28mm$^2$, respectively. And the volume ratio of the PZT cell were 52, 64%, respectively. The resonant frequency and anti-resonant frequency of the composites were 3.5 MHz and 4.3MHz, respectively. The piezoelectric coupling coefficient were about 38 and 37% and the mechanical quality factor were about 12.7 and 22. These value were very different from these of bulk PZT Plate.

  • PDF

The Evaluation of the Hysteretic Behavior of the Viscoelastic Material in the Resonant Test (공진법시험에서 나타난 점탄성재료의 히스테레시스 영향평가)

  • Choi, Hyun;Kim, Doo-Hoon;Lee, Sang-Jo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.596-601
    • /
    • 1998
  • Rubber has been widely used as a good device for reducing the vibration in various fields including the anti seismic device like LRB. The damping characteristic is needed to be mathematically modeled to predict the dynamic behavior of the isolated system. In this paper, The frequency response function was obtained experimentally by the resonant method and simulation was performed with the hysteretic model using the resonant test result. the hysteretic behavior of the rubber can be explained by the change of the static stiffness obtained in the DC by the concept of the transfer function.

  • PDF

Effect of Multi-Swirl Injector on Acoustic Damping in Model Combustion Chamber (모형 연소실에 장착된 다중 스월인젝터의 음향학적 감쇠 효과)

  • Kim, Hyun-Sung;Kim, Byung-Sun;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.198-203
    • /
    • 2007
  • The aim of this study is to suppress the high-frequency combustion instability by acoustic absorption through swirl injector with variable air core length. In the previous study, acoustic damping effects on air core (length, shape, volume) and location of the injector in a model chamber were investigated. Through previous results, our study has advanced to the effect of tuned multi-injectors. From the experimental data, it is proved that increasing of numbers of injectors mounted each anti-node point can increase acoustic damping effect. Also, when tuned injectors at 1L, 1T, 1L1T modes simultaneously are installed each anti-node point of model chamber, damping effect of tuned injectors with multi modes is well agreed with it of tuned injectors with single mode.

  • PDF