Browse > Article

Piezoelectric immunosensor for the detection of Edwardsiellosis  

Hong, Sung-Rok (Faculty of Marine Bioscience and Technology, Department of Chemistry, Kangnung National University)
Choi, Suk-Jung (Faculty of Marine Bioscience and Technology, Department of Chemistry, Kangnung National University)
Jeong, Hyun-Do (Department of Aquatic Life Medicine, Pukyong National University)
Hong, Su-Hee (Faculty of Marine Bioscience and Technology, Department of Chemistry, Kangnung National University)
Publication Information
Journal of fish pathology / v.20, no.3, 2007 , pp. 307-313 More about this Journal
Abstract
In this study, a QCM biosensor was made to detect Edwardsiella tarda (E. tarda) using a specific antibody. A 9 MHz AT-cut piezoelectric wafer layered with two gold electrodes of 5mm diameter had a reproducibility of 0.1 Hz in frequency response and was used as the transducer of the QCM biosensor. Self assembled layer (SAM) was conformed on a quartz crystal by treating with 3-mer-captopropionic acid (MPA) and activated with N-ethyl-N'-(3-dimethyl-aminopropyl) carbodiimide (EDC) and N-hydroxysuccinimide (NHS). The resulting NHS group was further converted to hydrazide by the reaction with hydrazine. Aldehyde group was introduced into the carbohydrate moiety of anti-E. tarda antibody by the reaction with periodic acid and was used to immobilise the antibody through the reaction with hydrazide group on the electrode surface. A baseline was established in the presence of phosphate-buffered saline (PBS) and a resonant frequency (F1) was measured. Sample was added to the sensor surface and second resonant frequency (F2) was measured after unbound substances were washed out with PBS several times. Finally, the frequency shift (ΔF) representing the mass change was calculated by subtracting F2 from F1. After adding the oxidized anti-E. tarda antibody to the electrode surface containing hydrazide group, frequency shift of 288.811.4 Hz (mean S.E) was observed, thus proving that considerable amount of antibody was immobilized. In the immunoassay test, the frequency shift of 1877.75 Hz, 580.67 Hz, 221.39 Hz, 7.671.83 Hz (mean S.E) were observed at doses of 1000, 500, 100, 50 g of bacterial cells, respectively. It was also demonstrated that the prepared sensor chip was stable enough to withstand repeated surface regeneration with 0.2 M Tris-glycine and 1 % DMSO, pH 2.3 more than ten times.
Keywords
Edwardsiella tarda; QCM biosensor; Antibody;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Byers, H. K., Cipriano, R. C. Gudkovs, N., and Crane, M. St. J.: PCR-based assays for the fish pathogen aeromonas salrnonicida. II.Further evaluation and validation of three PCR primer sets with infected fish. Dis. Aquat. Org., 49: 139-144, 2002   DOI
2 Kubota, S., Kaige, N., Miyazaki, T and Miyashita, T.: Histopathological studies of edwardsiellosis of Tilapia l. Natural infection. Vull. Fac. Fsih., Mie Univ., 9: 155-65, 1982
3 Kusuda, R., Itami, T., Munekiyo, M. and Nakajima, H: Characteristics of all Edwardsiella sp. from an epizootic of cultured crimson sea breams. Bull. Jap, Soc. Scient. Fish., 43: 129-234, 1977   DOI
4 Lin, Z., Yip, C. M., Joseph, I. S. and Ward, M. D.: Operation of an Ultrasensitive 30-MHz Quartz Crystal Microbalance in Liquids, Anal. Chem. 65: 1546-1551, 1993   DOI   ScienceOn
5 Steegborn, C. and Skladal, P.: Construction and characterisation of the direct piezoelectric immunosensor for atrazine operating in solution. Biosens. Bioelectron., 12:19-27, 1997   DOI   ScienceOn
6 Wakabayashi, J. and Egusa, S.: Edwardsiella tarda (Paracolo- bacterium anguillimortiferum) associated with pond-cultured eel disease. Bull. Jap. Soc. Scient. Fish., 39:931-936, 1973   DOI
7 Minunni, M., Mascini, M., Guilbault, G. G. and Hock, B.: The Quartz Crystal Microbalance as Biosensor. A Status Report.: Anal. Letters, 28: 749-764, 1995   DOI   ScienceOn
8 Meyer, F. P. and Bullock, G. L.: Edwatdsiella tarda, a new pathogen of channel catfish (Ictalurus punctatus) Appl. Microbiol. 25: 155-156, 1973
9 Bunde, R. L., Jarvi, E. J. and Rosentreter, J. J.: Piezoelectric quartz crystal biosensors. Talanta, 46, pp. 1223-1236, 1998   DOI   ScienceOn
10 Kusuda, R., Toyoshima, T., Iwamura, Y. and Sako, H.: Edwardsiella tarda from an epizootic of mullets (Mugil cephalus) in Okitsu Bay. Bull. Jap. Soc. Scient. Fish., 42: 271-275, 1976   DOI
11 Amandi, A., S.F. Hiu, J. S. Rohovec, and J. L. Fryer.: Isolation and characterization of Edwardsiella tarda from fall chinook salmon (Oncorhvnchus tshawytscha). Applied Environ. Microbiol. 43: 13801384, 1982
12 Shons, A., Dorman and F. Najarian, J.: An immunospecific microbalance, J. Biomed. Mater. Res., 6: 565-570, 1972   DOI   ScienceOn
13 Horisberger, M. and Vauthey, M.: Labelling of colloidal gold with protein a quantitative study using $\beta$-lactoglobulin, Histochemistry 80(1):13-19, 1984   DOI
14 Muramatsu, H., Dicks, J. M., Tamia, E. and Karube, I.: Piezoelectric Crystal Biosensor Modified with Protein A for Determination of Immunoglobulins. Analytical Chemistry, 59: 2760-2763, 1987   DOI   ScienceOn
15 Uttenthaler, E., Kosslinger, C. and Drost, S.: Characterization of immobilization methods for African swine fever virus protein and antibodies with a piezoelectric immunosensor. Biosens. Bioelectron., 13: 1279-1286, 1998   DOI   ScienceOn
16 Absolom D., R., Zingg, W. and Neumann, A. W.: Protein adsorption to polymer particles: role of surface properties. J. Biomed. Mater. Res. 21: 161-171, 1987   DOI   ScienceOn
17 Clark, D. J., Blake-Coleman, B. C., and Calder, M. R.: Principles and potential of piezo-electric transducers and acoustical techniques. in Biosensors : fundamentals and Application(Turner, A. P. F., Karube, I. and Wilson, G.S., eds.), Oxford University press. Oxford, pp 551-571, 1987
18 Guilbault, G. G., Hock, B. and Schmid, R.: A Piezoelectric Immunobiosensor for Atrazine in Drinking Water. Biosensors Bioelectronics 7: 411-420, 1992   DOI   ScienceOn
19 Vikholm, I., Viitala, T., Albers, W.M. and Peltonen, J.: Highly efficient immobilisation of antibody fragments to functionalised lipid monolayers, Biochim. Biophys. Acta., 1421: 39-52, 1999   DOI   ScienceOn
20 Prusak-Sochaczewski E, Luong, J. H. and Guilbault, G. G.: Development of a piezoelectric immunosensor for the detection of Salmonella typhimurium. Enzyme Microb Technol., 12(3): 173-177, 1990   DOI   ScienceOn
21 Boveniser, J. S., Jacobs, M. B., Guilbault, G. G. and O'Sullivan, C. K.: The detection of Pseudomonas aeruginosa using the quartz crystal microbalance. Anal. Lett., 31: 1287-1295, 1998   DOI   ScienceOn
22 Skladal, P., Minunni, M., Mascini, M., Kolar, V., and Franek, M.: Characterization of MonoclonalAntibodies to 2.4A-Dichlorophenoxyacetic Acid Using A Piezoelectric Quartz- Crystal Microbalance in Solution. J. Immunol. Methods 176: 117-125, 1994   DOI   ScienceOn
23 Matsumura, H. and Kleijn, J. M.: Admittance measurements on protein layers adsorbed at the Pt/solution interface : effect of d.c. potential and a.c. field. Colloids and surfaces. B, Biointerfaces, 277-282, 1993
24 Attili, B. S. and Suleiman, A. A.: A piezoelectric immunosensor for the detection of cortisol. Anal. Lett. 28: 2149-2159, 1995   DOI   ScienceOn
25 Konig, B. and Gratzel, M.: Human granulocytes detected with a piezoimmunosensor, Anal. Letters. 26(11):2313, 1993   DOI
26 Konig, B. and Gratzel, M.: A novel immunosensor for herpes viruses, Anal. Chem. 66: 341, 1994   DOI   ScienceOn
27 Yu, L., Yuan, L., Feng, H. and Li, S.F.Y. : Determination of the bacterial pathogen Edwardsiella tarda in fish species by capillary electrophoresis with blue light-emitting diode-induced fluorescence. Electrophoresis, 25: 3139-3144, 2004   DOI   ScienceOn