• 제목/요약/키워드: Anti-islanding detection

검색결과 49건 처리시간 0.023초

역상분 전류 주입을 적용한 3상 인버터 기반 BESS의 단독 운전 검출 방법 (Anti-islanding Detection Method for BESS Based on 3 Phase Inverter Using Negative-Sequence Current Injection)

  • 신은석;김현준;한병문
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1315-1322
    • /
    • 2015
  • This paper proposes an active islanding detection method for the BESS (Battery Energy Storage System) with 3-phase inverter which is connected to the AC grid. The proposed method adopts the DDSRF (Decoupled Double Synchronous Reference Frame) PLL (Phase Locked-Loop) so that the independent control of positive-sequence and negative-sequence current is successfully carried out using the detected phase angle information. The islanding state can be detected by sensing the variation of negative-sequence voltage at the PCC (Point of Common Connection) due to the injection of 2-3% negative-sequence current from the BESS. The proposed method provides a secure and rapid detection under the variation of negative-sequence voltage due to the sag and swell. The feasibility of proposed method was verified by computer simulations with PSCAD/EMTDC and experimental analyses with 5kW hardware prototype for the benchmark circuit of islanding detection suggested by IEEE 1547 and UL1741. The proposed method would be applicable for the secure detection of islanding state in the grid-tied Microgrid.

Digital PLL을 이용한 Active Frequency Drift Positive Feedback에 관한 연구 (Active Frequency Drift Positive Feedback Method for Anti-islanding applied Digital Phase-Locked-Loop)

  • 이기옥;최주엽;최익;정영석;유권종;송승호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.250-254
    • /
    • 2007
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive powers of the load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

  • PDF

디지털 위상검출기법을 적용한 능동적 주파수 변화 정궤환기법 (Active Frequency Drift Positive Feedback Method for Anti-islanding using Digital Phase-Locked-Loop)

  • 이기옥;정영석;최주엽;최익;송승호;고문주
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.37-44
    • /
    • 2007
  • As photovoltaic(PV) power generation system becomes more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive power of the load and PV system are closely matched, islanding detection by Passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

단독운전검출을 위한 능동적 주파수 변화 정궤환기법 (Active Frequency Drift Positive Feedback Method for Anti-islanding)

  • 소정훈;정영석;유권종;유병규;이기옥;최주엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1684-1686
    • /
    • 2005
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive power of load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop(DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment in IEEE Std 929-2000 islanding test.

  • PDF

계통 연계형 태양광 발전 시스템의 부하 무효전력 보상이 적용된 단독운전 인지법 (The Anti-Islanding Method with Compensation of Load Reactive Power for Grid-connected Photovoltaic Generation System)

  • 정진범;신동현;김희준
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.58-64
    • /
    • 2008
  • In this paper, we present an active anti-islanding method with a load monitoring system using reactive power control. The proposed method, which is based on reactive power control, has fewer harmonics components than those in conventional methods, and it can minimize the reactive power component of the grid because it compensates the reactive power component with the load monitoring. The proposed quick islanding detection method was confirmed from the experimental results with an inverter for a 3kW photovoltaic system.

슬립모드 방식을 이용한 단독운전 검출기법의 모델링과 평가 (Modeling and Evaluation of Slip-Mode Frequency Shift Method for Anti-islanding Method)

  • 유병규;정영석;소정훈;유권종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.520-522
    • /
    • 2005
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized reclosure. In order to prevent this phenomenon, various anti-islanding methods have been studied. Even though the slip mode frequency shift (SMS) method has been regarded as a highly effective anti-islanding method, the analytical design method of that was not cleared. This paper proposes a modeling of the SMS method using non-detection zone (NDZ) and evaluation of the method according to the test conditions of IEEE Std. 929-2000. The SMS method is derived analytically through the modeling and verified visually by simulation and experiment.

  • PDF

슬립모드 주파수변이 방식의 단독운전 검출법의 분석과 모델링 (Analysis and Modeling of Slip Mode Frequency Shift Method for Anti-islanding)

  • 유병규;정영석;소정훈;유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1699-1701
    • /
    • 2005
  • Islanding phenomenon is undesirable because it lead to a safety hazard to utility service personnel and may cause damage to power generation and rower supply facilities as a result of unsynchronized reclosure. In order to prevent this phenomenon, various anti-islanding methods have been studied. Even though the slip mode frequency shift(SMS) method has been regarded as a highly effective anti-islanding method, the analytical design method of that was not cleared. This paper proposes a modeling of the SMS method using non-detection tone(NDZ) and evaluation of the method according to the test conditions of IEEE Std. 929-2000. The SMS method is derived analytically through modeling and verified visually by simulation and experiment.

  • PDF

Slip-Mode Frequency Shift 단독운전 검출 기법의 정상상태 전력 품질 개선 (Design of Modified Slip-Mode Frequency Shift Islanding Detection Method for Power Quality Improvement)

  • 김동욱;김성민
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.539-547
    • /
    • 2018
  • 계통 연계형 인버터는 단독운전 조건에서 반드시 전력 공급을 차단해야 한다. 이러한 이유로 분산 발전 시스템은 단독운전을 검출 기능을 반드시 가지고 있어야 한다. 분산 발전용 인버터에 적용되는 일반적인 방법 중에는 Slip-Mode frequency Shift (SMS) 단독운전 검출 기법이 있다. SMS 기법은 계통 전압의 주파수에 따라 무효 전력을 공급하여 단독운전 조건에서 계통 주파수를 허용 범위 밖으로 이동시키는 방법이다. SMS 기법은 안정적으로 단독운전을 검출할 수 있으며, 계통 전류에 고주파를 인가하지 않는다는 장점이 있으나, 무효 전류를 인가하기 때문에 계통 역률이 나빠져서 전력 품질의 저하를 가져온다. 본 논문에서는 계통 전원이 연결되어 있는 정상 조건에서 전력 품질 저하가 없는 수정된 SMS 기법을 제안한다. 600W 단상 인버터 실험을 통해 제안된 방법의 유효성을 검증한다.

배전계통연계 분산전원의 위상변화에 따른 고립운전 파라미터 특성 (A Study on Islandig Characteristics using Phase Angle Adjustment of Distributed Generation)

  • 방지윤;김학만;이복구;심재선;신명재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.525-526
    • /
    • 2006
  • Recently, much research has been done and many improvements have been developed for islanding protection of distributed generation(DG). Anti-islanding protection for DG must be act very quickly to prevent equipment damage at the time of disconnection and for the safety of maintenance and repair personnel. DG-based detection methods have included both passive and active types, and now research has shifted towards new anti-islanding detection methods that make up for the defects of the previous types. Because differences occur between the utility grid and the DG when connecting and disconnecting depending on the phase difference, voltage, current, relative capacity of electric power, and system operation characteristics, voltage phase angle is an important consideration. In this paper, we simulated islanded operation characteristics comparing phase difference of DG and the connected utility grid, and analyzed various parameters (real power, reactive power, RMS voltage, RMS current, power factor angle, and frequency) by varying the DG's voltage phase angle. Using this information, we propose a suitable DG voltage phase angle for enhanced passive islanding detection techniques.

  • PDF

전향보상 전압의 위상 변화를 통한 단독운전 검출 방법의 계통 정상 상태의 성능 평가 (Performance Evaluation of Islanding Detection Method by Phase Shifted Feed-Forward Voltage in Steady-State Grid Condition)

  • 김동욱;김성민
    • 전력전자학회논문지
    • /
    • 제23권6호
    • /
    • pp.373-380
    • /
    • 2018
  • This study proposes a new islanding detection method that uses the phase shift of feed-forward voltage and evaluates the performance of an existing method and the proposed method when the grid frequency changes within the allowable range under steady-state conditions. The investigated existing method, which is slip mode frequency shift (SMS), uses current phase shift to detect islanding. The SMS method supplies reactive current to the grid under this condition, but the proposed method does not generate additional reactive power because it does not depend on the current control loop. The performance in steady-state grid condition is evaluated through simulations and experiments.