• 제목/요약/키워드: Anti-freezing

검색결과 117건 처리시간 0.032초

재조합 대장균을 이용한 GFP-AFP Chimera 단백질 과량발현 및 특성 파악연구 (Overexpression of GFP-AFP Chimera Protein using Recombinant Escherichia coli and Analysis of Anti-freezing Characteristics)

  • 고지선;홍순호
    • KSBB Journal
    • /
    • 제28권5호
    • /
    • pp.310-314
    • /
    • 2013
  • Antifreeze peptide from Myoxocephalus octodecemspinosus was overexpressed and purified in Escherichia coli. Green fluorescence protein-AFP chimera was constructed by integrating gfp and afp genes. Produced GFP-AFP chimera protein was purified using polyhistidine tag which was inserted at C-terminus. By addition of GFP-AFP chimera protein, freezing point of elution buffer was decreased from $-13^{\circ}C$ to $-20^{\circ}C$. This result suggested that GFP-AFP chimera can be considered as a potential candidate of novel inhibitor for gas hydrates.

주물고사 첨가 아스팔트 콘크리트의 특성에 관한 연구 (Characteristics of Asphalt Concrete using Waste Foundry Sand)

  • 김광우;고동혁;최동춘;김성운;김중열
    • 한국도로학회논문집
    • /
    • 제3권4호
    • /
    • pp.105-116
    • /
    • 2001
  • 본 연구는 주물고사를 이용한 아스팔트 콘크리트와 주물고사의 물리적 화학적 특성을 비교 분석하는 것이다. 주물고사의 아스팔트 콘크리트 적용성을 평가하기 위하여 XRF, SEM, 제타전위를 측정하여 주물고사의 물리 화학적 특성을 알아보았다. 주물고사 아스팔트 콘크리트의 박리저항성을 향상시키기 위하여 박리방지제(소석회(Hydrated lime), 액상박리방지제)를 사용하였다. 그리고 주물고사 아스팔트 콘크리트 혼합물의 인장특성과 내구성 향상을 위하여 LDPE를 사용하였다. 또한 주물고사 아스팔트 콘크리트의 공용성을 알아보기 위하여 간접인장강도, 수분취약성시험, 동결 융해시험, 반복주행시험을 수행하였다. 시험결과 주물고사 아스팔트 콘크리트의 역학적 특성이 일반 아스팔트 콘크리트에 비해 같거나 향상되는 것으로 나타났다. 따라서 주물고사를 아스팔트 콘크리트에 재활용할 수 있다는 결론을 얻었다.

  • PDF

열선의 직선시공과 감기시공의 동파방지 효과 비교를 위한 3차원 비정상 수치해석 (Comparison of the Effects of Straight and Twisted Heat Trace Installations Based on Three-dimensional Unsteady Heat Transfer)

  • 최명영;전병진;최형권
    • 한국화재소방학회논문지
    • /
    • 제30권1호
    • /
    • pp.49-56
    • /
    • 2016
  • 본 논문에서는 동절기 소방배관의 동파방지를 위한 열선의 직선 시공과 감기 시공의 효과를 수치해석을 통하여 분석하였다. 두 시공법들의 효과 분석을 위하여 3차원 에너지방정식과 비정상 비압축성 Navier-Stokes 방적식의 비정상 해를 구하였다. 수치해석에서 물의 자연대류와 소방 배관의 열전도 방정식이 상호작용을 하므로 복합열전달 해석을 상용코드 ANSYS-FLUENT에서 제공하는 압력-속도 연성기법들 중의 하나인 SIMPLE 알고리즘을 이용하여 수행하였다. 수치해석을 통하여 시간에 따른 배관 내의 유동장 및 온도분포와 배관 내 물의 최대 및 최소온도 변화를 고찰하였다. 수치해석 결과 배관 단위 길이 당 투입열량이 동일한 경우에 감기 시공과 직선 시공의 동파방지 효과는 거의 동일함을 확인하였다. 따라서, 열선 손상과 단락 등을 고려하면 직선 시공이 더 나은 시공법이라 판단된다.

Wearable Sensor based Gait Pattern Analysis for detection of ON/OFF State in Parkinson's Disease

  • Aich, Satyabrata;Park, Jinse;Joo, Moon-il;Sim, Jong Seong;Kim, Hee-Cheol
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2019년도 춘계학술대회
    • /
    • pp.283-284
    • /
    • 2019
  • In the last decades patient's suffering with Parkinson's disease is increasing at a rapid rate and as per prediction it will grow more rapidly as old age population is increasing at a rapid rate through out the world. As the performance of wearable sensor based approach reached to a new height as well as powerful machine learning technique provides more accurate result these combination has been widely used for assessment of various neurological diseases. ON state is the state where the effect of medicine is present and OFF state the effect of medicine is reduced or not present at all. Classification of ON/OFF state for the Parkinson's disease is important because the patients could injure them self due to freezing of gait and gait related problems in the OFF state. in this paper wearable sensor based approach has been used to collect the data in ON and OFF state and machine learning techniques are used to automate the classification based on the gait pattern. Supervised machine learning techniques able to provide 97.6% accuracy while classifying the ON/OFF state.

  • PDF

국내 LTPP 온도 자료를 이용한 동결지수와 동결깊이 검증 연구 (Verification of Freezing Index and Frost Penetration Depth with Temperature Data of Korea LTPP)

  • 김부일;전성일;이문섭;임광수
    • 한국도로학회논문집
    • /
    • 제11권4호
    • /
    • pp.143-152
    • /
    • 2009
  • 본 연구의 목적은 현재 국내에서 적용되고 있는 동결지수와 동결깊이 산정의 타당성을 검증하는 것이다. 이에 국내에서 운영되고 있는 LTPP-SPS(Long Term Pavement Performance- Specific Pavement Study)구간의 대기온도와 포장체 깊이별 온도 데이터를 이용하여 동결지수와 동결깊이를 산정하였으며, 기존 계산식을 이용하여 산출된 동결깊이와 비교 분석하였다. 또한 이 구간들의 인근 측후소 데이터를 이용하여 연도별 동결지수 추이를 분석하였다. 본 연구 결과, 지구온난화에 의해 1987년 이후에는 동결지수가 급격히 감소하였으며, 현재 도로설계 시 적용되고 있는 동결지수가 과하게 적용되고 있음을 알 수 있었다. 이에 동결지수 산정 시 현행 30년 데이터를 토대로 산정하기보다 기후가 변화된 시점부터 현재까지의 추이를 분석하는 것이 바람직 할 것으로 사료된다. 또한 LTPP-SPS 구간에서 측정된 포장체 깊이별 온도데이터를 분석한 결과, 동상방지층이 설계되어 있는 3개구간에서 대체적으로 보조기층까지만 동결이 발생하는 것으로 나타나, 동상방지층이 제 역할을 수행하지 못하는 것으로 나타났다. 실제 측정된 동결깊이와 계산식을 통해 산정된 동결깊이를 비교한 결과, 노상동결관입허용법을 이용한 설계방법이 실제 측정된 동결깊이와 가장 유사한 경향을 나타내었다.

  • PDF

생쥐 난자의 효율적인 냉동보존 방법 확립을 위한 연구 (Development of Effective Cryopreservation Method for Mouse Oocytes)

  • 최수진;김수경;김지선;조재원;전진현;변혜경
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제31권1호
    • /
    • pp.75-81
    • /
    • 2004
  • Objective: The purpose of this study was to evaluate the efficacy and effect of various cryopreservation method on the survival and the cytoskeletal stability of metaphase II mouse oocyte. Methods: Mouse ovulated oocytes were collected and cryopreserved by a modified slow-freezing method with 1.5 M 1, 2-propanediol (PrOH)+0.1 M sucrose or by vitrification using cryo loop and EM grid with 40% ethylene glycol+0.6 M sucrose. Four hours after thawing, intact oocytes were fixed and stained with fluorescein isothiocyanate (FITC)-conjugated monoclonal anti-$\beta$-tubulin antibody to visualize spindle and propidium iodide (PI) to visualize chromosome. Spindle morphology was classified as follows: normal (barrel-shaped), slightly and absolute abnormal (multipolar or absent). Results: Survival rate of the frozen-thawed oocytes in vitrification group was significantly higher than that of slow-freezing group (62.7% vs. 24.4%, p<0.01). Vitrification with cryo loop showed significantly higher survival rate than that with EM grid (67.7% vs. 53.5%, p<0.05). On the other hand, proportion of normal spindle and chromosome configurations of the frozen-thawed oocytes between two vitrification group was not significantly different. Conclusion: For mouse ovulated oocytes, vitrification with cryo loop may be a preferable procedure compared to slow-freezing method. Further study should be needed to investigate developmental competency of frozen-thawed mouse oocytes.

냉매를 작동유체로 사용하는 태양열 난방시스템에 관한 연구 (A study on the solar assisted heating system with refrigerant as working fluid)

  • 김지영;고광수;박윤철
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.37-44
    • /
    • 2005
  • An experimental study was conducted to analyze performance of a heating system with variation of control logic of the system. The system uses a solar as heat source and composed with heat pump that uses R-22 as working fluid. The difference between the developed system and the commercially available heating system is working fluid. The solar assisted heating system which was widely distributed in the market uses water as a working fluid. It could be freezing in case of the temperature drops down under freezing point. The anti-freezing fluids such as methyl-alcohol or ethylene-glycol are mixed with the water to protect the freezing phenomena. However, the system developed in this study uses a refrigerant as a working fluid. It makes the system to run under zero degree temperature conditions. Another difference of the developed system compare with commercial available one is auxiliary heating method. The developed system has removed an auxiliary electric heater that has been used in conventional solar assisted heating system. Instead of the auxiliary electric heater, an air source heat exchanger which generally used as an evaporator of a heat pump was adapted as a backup heating device of the developed system. As results, an efficiency of the developed system is higher than a solar assisted heat pump with auxiliary electric heater. The merit of the developed system is on the performance increment when the system operates at a lower solar energy climate conditions. In case of the developed system operates at a normal condition, COP of the solar collector driven heat pump is higher than the air source heat exchanger driven heat pump's.

콘크리트용 혼화제의 동결온도 및 동결된 혼화제의 사용에 따른 콘크리트의 품질변화 (The Freezing Temperature of Chemical Admixtures for Concrete and the Quality Vareation of Concrete Using the Frozen Admixtures)

  • 한천구;한경익;이건철
    • 콘크리트학회지
    • /
    • 제10권4호
    • /
    • pp.205-212
    • /
    • 1998
  • 레미콘을 제조하는 배쳐플랜트에는 혼화제를 저장하는 저장탱크가 설치되어 있는데, 특히 기온이 $0^{\circ}C$이하로 저하하는 겨울철에는 혼화제 저장탱크내의 혼화제가 동결할 수 있어 설비보존 목적상 동결온도의 검토가 요구되고 또한 동결된 혼화제를 이용할 경우 레미콘의 품질 변화가 초래될 수 있는지 검토가 요구되지만 국내의 경우 연구보고나 규정은 마련되어 있지 않은 실정이다. 그러므로 본 연구에서는 본 연구에서는 국내에 유통되고 있는 콘크리트용 각종 화학혼화제를 무작위로 시료채취하여 동결온도를 측정하므로써 동절기 외기에 노출된 혼화제 투입설비에 대한 적정 보온대책의 제안 및 레미콘에서 반드시 사용되어지는 AE제 및 AE감수제 등의 혼화제를 대상으로 동결전과 동결융해를 반복한 혼화제를 사용한 콘크리트의 품질변화에대하여 실험연구를 실시하였다. 연구결과 방동제, AE감수제 촉진형 등 내한성 혼화제를 제외한 대부분의 혼화제는 제주도 및 일부 남부 지방을 제외한 한국의 겨울철 외기온 조건하에서는 혼화제의 동결위험성이 있으므로 보온조치가 필요할 것으로 판단되며, 동결된 혼화제를 사용할 경우의 콘크리트 품질변화는 교반을 충분히 하여 이용한다면 슬럼프, 공기량, 강도 등에서 크게 문제시 되지 않는 것으로 분석되었다.

도로포장체의 동결에 영향을 미치는 통계적 요인 (The statistical factors affecting the freezing of the road pavement)

  • 김현지;이제영;김병두;조규태
    • Journal of the Korean Data and Information Science Society
    • /
    • 제27권1호
    • /
    • pp.67-74
    • /
    • 2016
  • 우리나라의 기후적 특성으로 토지가 동절기에는 동결작용을 받고 해빙기에는 융해작용을 받는다. 이러한 동결융해작용의 피해를 최소화하기 위하여 도로 포장 분야에서는 도로 포장 두께에 관한 많은 연구들이 진행 중에 있다. 본 연구는 도로포장 현장계측 온도데이터를 이용하여, 도로 포장 두께를 위해 사용되는 변수들의 적절성을 확인하기 위해 엔트로피 지수를 이용한 의사결정나무 분석을 시행한다. 각 층 온도를 이용하여 생성한 최저동결층 (순서형 변수)을 목표변수로 분석하며, 분석에 사용된 독립변수는 동결지수에 따라 $350{\sim}450^{\circ}C{\cdot}$일, $450{\sim}550^{\circ}C{\cdot}$일, $550{\sim}650^{\circ}C{\cdot}$일로 구분된 지역 변수, 절토부, 절성경계부, 2m 이하 성토부 구간으로 이루어진 단면 변수 그리고 동상방지층 설치 유무이다. 또한, 월과 대기온도도 독립변수에 포함시킨다. 그 결과, 월, 동상방지층 유무, 대기온도, 지역 순으로 최저동결층에 영향을 주는 것으로 나타났다.