T-50 비행시험을 통한 환경제어계통 콘덴서 빙결방지 설계 검증 (Design Verification of ECS Condenser Icing Protection System by Flight Test of T-50 Advanced Trainer)

  • 남용석;김윤희;송석봉;서동연;손원익;박성순
    • 항공우주시스템공학회지
    • /
    • 제2권3호
    • /
    • pp.40-44
    • /
    • 2008
  • T-50 ECS(environment control system) was designed to have freezing protection for the condenser. However during the ground and flight test, the freezing problem was occurred. This paper deals with the analysis of the freezing problem and introduces anti-freezing design using ADI(Active De-Icing) logic to solve the condenser freezing problem of T-50 ECS

  • PDF

도로 포장체에서 동상에 대한 지하수위 영향 평가 (Evaluation of Ground Water Level Effect on Frost Heaving in Road Pavements)

  • 권기철;이재환
    • 한국도로학회논문집
    • /
    • 제15권1호
    • /
    • pp.47-56
    • /
    • 2013
  • PURPOSES: This study is to evaluate a ground water level effect on frost heaving in road pavements. METHODS: The effects of water table on frost heaving in pavement systems were evaluated from the mechanical analysis using FROST program. The input parameters and boundary conditions were determined by considering climates, pavement sections, and material properties specially subgrade soil types in Korea. RESULTS: When the water table located above the freezing depth, amount of frost heaving caused by freezing the water in pavement itself was big enough to damage in pavement system, although pavement system consists of fully non-frost-susceptible materials with sufficient thickness of anti-freezing layer. The amount of frost heaving was decreased rapidly with increasing the distance between the water table and freezing depth. CONCLUSIONS: It was concluded that there is no engineering problems related with frost heaving in practical sense when the distance between freezing depth and water table is over 1.5m for having subgrade soils less than 50% of #200 sieve passing to meet specification on quality control in Korea.

현장파쇄 순환골재의 동상방지층 및 빈배합 콘크리트층에 대한 적용성 평가 (Assessment of Application of the Recycled Aggregate Crushed in-situ for Anti-freezing Layer and Lean Concrete Base Course)

  • 김진철;김홍삼
    • 한국건설순환자원학회논문집
    • /
    • 제1권1호
    • /
    • pp.98-107
    • /
    • 2005
  • 고속도로 건설 및 유지관리 과정에서 발생되는 폐콘크리트의 재활용을 위하여 현장파쇄에 의한 순환골재의 생산 및 도로용 재료의 시방기준 준수여부를 평가하여 최적의 파쇄방법을 선정하였으며, 최적 파쇄방법에 의해 생산된 순환골재를 이용한 시험시공을 실시하였다. 현장파쇄 순환골재의 입도시험결과 임팩트 크러셔 또는 죠, 콘크러셔 조합형이 소요입도에 적합한 순환골재를 생산할 수 있었다. 생산된 순환골재를 동상방지층에 적용할 경우 함수비 변동에 의한 건조밀도 변화가 작으므로 천연골재에 비하여 관리가 쉬운 장점이 있었으며, 빈배합콘크리트 기층의 경우 재령 7일 압축강도는 순환골재의 종류에 관계없이 10MPa를 상회하므로 현장적용에는 큰 문제가 없음을 알 수 있었다. 시험시공 적용 결과 동상방지층의 경우 순환 굵은골재, 스크리닝스 및 모래를 소요입도로 혼합하였을 때 양호한 지지력을 나타내었으며, 순환골재 빈배합 콘크리트의 강도는 천연쇄석에 비하여 71~85% 강도를 나타내었으나 배합강도 5.8MPa를 크게 상회하였으므로 현장적용에는 문제없음을 확인하였다.

  • PDF

포름산-아세트산염계 방동제를 사용한 콘크리트의 특성 (Properties of Cold Weather Concrete Using Anti-freeze Agent Based Formate-acetate)

  • 조현태;김호수;전준영;류득현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.617-620
    • /
    • 2008
  • 최근 대규모 건축물의 등장으로 말미암아 연중 시공이 이루어지고 있으며, 한중 콘크리트 시공시동결에 의한 콘크리트 품질저하의 문제점이 부각되어지고 있는 실정이다. 따라서 본 연구에서는 한중콘크리트의 품질 확보 방안중의 하나로서 포름산-아세테이트산염을 주성분으로 한 무염화형 방동제를 적용한 콘크리트의 품질 및 특성에 대하여 성능 검토를 실시하였다. 포름산-아세테이트산염계 방동제의 적용시험을 수행한 결과, 영하권 외기 양생 조건에서 경화콘크리트 특성은 방동제를 첨가하지 않는 시료에 비하여 모든 재령에서 우수한 강도 발현 특성을 나타내고 있었으며, 장기재령에서도 강도 저하 현상이 발생하지 않았다. 또한 굳지않은 콘크리트의 유동특성 및 경화 콘크리트의 특성을 고려한 결과 결합재의 3.0%내외의 방동제 적용량이 가장 우수한 결과를 나타내었다.

  • PDF

실내동결시스템을 이용한 노상토의 동상 특성 (The Frost Heaving Characteristics of Subgrade Soils Using Laboratory Freezing System)

  • 신은철;류병현;박정준
    • 한국도로학회논문집
    • /
    • 제12권2호
    • /
    • pp.71-79
    • /
    • 2010
  • 겨울에는 시베리아기단의 영향으로 한랭 건조한 대륙성 고기압의 영향을 받아 춥고 건조하여 1월 평균기온이 $-6{\sim}-7^{\circ}C$의 영하의 온도로 낮아져 지반동결시 수분이동으로 동상현상이 발생하여 도로의 불균형 동결팽창을 초래하며, 결국 포장체를 파손시킨다. 동상발생시 토립자는 모관력에 의해 지하수를 흡수하여 아이스렌즈를 형성하며, 이 모관 흡수력은 토립자의 크기에 영향을 받는다. 도로는 다양한 재료와 단면으로 구성된 구조물이기 때문에 환경성과 재료 물성뿐만 아니라 포장체 각 층의 구조적 적정성 또는 지지력을 파악하는 것이 무엇보다 중요하다. 현재 기존 동상방지층 설계법에 따르면, 동상방지층은 포장체의 구조적 적정성과는 무관하게 온도 조건에 따른 동결깊이에 따라 일률적으로 결정되고 있다. 이러한 동결깊이를 포장구조설계에 적용함으로써 포장의 과다설계 우려가 있다. 따라서 본 논문에서는 도로 동상방지층의 효용성 검증 및 설치기준 확립을 위해 실내동결시스템을 활용하여 도로 노상토의 동상 특성에 대한 민감성을 판별, 도로건설 현장 노상토에 대한 역학적 특성과 실내 동결 시험을 수행하였으며, 외부 동결온도의 지속 조건에 대한 시료의 온도변화, 동상팽창압, 동상팽창량, 부동수분 등의 결과값을 통하여 동결 과정에 따른 지반공학적 특성을 평가하였다.

전기적 열선의 발화 및 화재 위험성에 관한 연구 (A Study on Ignition and Fire Risks of Electric Heat Wire)

  • 민세홍;송병준
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.113-121
    • /
    • 2015
  • This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the 'heat wire') and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.

PHP를 이용한 도로융설 시스템에 관한 기초연구 (A Basic Study of the Snow Melting System for the Anti-Freezing Road using the Pulsating Heat Pipe)

  • 김종수;하수정;손길재
    • 동력기계공학회지
    • /
    • 제14권3호
    • /
    • pp.19-24
    • /
    • 2010
  • The purpose of this study is to develop a snow melting system using the pulsating heat pipe(PHP). The experimental apparatus is consisted of a PHP, a concrete structure, a constant water thermostatic bath and a flowmeter. The experiment was performed at the outdoor air temperature of $-8^{\circ}C$ and inlet temperature of hot water of $75^{\circ}C$. PHP is the closed and non-loop type heat exchanger which is charging R-410A as an operating fluid. As experimental results, the temperature profile of vertical and horizontal orientation of concrete structure was measured with operating time. The heat flux of the snow melting was required more than 300 $W/m^2$. We confirmed that the snow melting system using the PHP was useful for anti-freezing road.

기포제를 사용한 경량 콘크리트의 역학적 특성 및 동결융해 평가에 관한 실험적 연구 (An Experimental Study on Freezing-Thawing and Mechanical Properties of Lightweight Foamed Concrete Using Micro Foaming Agent)

  • 민태범;우영제;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.69-72
    • /
    • 2009
  • This research is focused on the applying of the foaming agent which can make the independent pore in the concrete structure in order to make a lightweight concrete structure. This lightweight foamed concrete can satisfy both the required strength and the mechanical properties as structural members. In addition, anti freezing-thawing properties also required. As a result of the unit volume-weight measurement, when the foaming agent mixed at 0.5% to 1%, the lightweight foamed concrete can be applied for the structural member. Also the density and compressive strength measurement results reveals that it will be suitable as structural member with 21MPa strength, when the density is betweenity8 to 1.9 and foaming agent quantities are 0.5% to 1%. Finally the result of freezing-thawing experiment, the effect freezing-thawing damage reduced according to adding foaming agent because those foaming agent make micro-pores in the structure which are not seen in the ordinary concrete structure.

  • PDF

도로 노면 일조량에 따른 결빙 위험도 평가 방법에 관한 연구 (Study about the Evaluation of Freezing Risk Based Road Surface of Solar Radiation)

  • 이동현;정원석;김홍진;김지원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권5호
    • /
    • pp.130-135
    • /
    • 2013
  • 결빙 방지 분사 시스템은 강설이 예상되거나 진행 중인 상황에서 신속하게 대응 가능하며, 동절기 결빙으로 인해 발생하는 교통사고와 교통 지정체를 감소시킬 수 있는 장점을 가지고 있다. 하지만 현재 국내에는 결빙 방지 분사 시스템의 설치 기준은 마련되어 있지 않다. 본 연구에서는 선형, 기상조건, 일조조건 등을 다양한 도로 조건을 정량화하여 어떤 구간에 우선적으로 결빙 방지 분사 시스템을 적용하여야 하는지 판단할 수 있는 기준을 제시한다. 이를 위해 국내 지역별 기상 조사, 지형지물에 의해 음지 발생 여부 분석, 선형과 미끄럼 저항성을 고려한 차량 시뮬레이션 등을 수행하고 이론적 검토를 통해 설치 기준 방법을 정립하였고, 또한 이를 반영하여 시스템의 설치를 판단할 수 있는 소프트웨어 (프로토타입)를 개발하였다.

충격공진시험을 이용한 동결.융해에 따른 노상토의 탄성계수 평가 (Evaluation of Freeze-Thaw Effect on the Modulus of Subgrade Soils from Impact Resonance Test)

  • 이재환;권기철
    • 한국도로학회논문집
    • /
    • 제12권3호
    • /
    • pp.71-77
    • /
    • 2010
  • 노상토의 동상 가능성이 없는 경우 동상방지층을 생략한다. 이러한 조건에서 노상토의 동결 융해가 발생하면, 동상이 없는 상태에서 탄성계수 변화를 수반하고, 포장설계에서 이를 합당하게 고려해야 한다. 동결 융해 과정의 연속적인 탄성계수 변화를 효과적으로 규명하고자 비파괴시험인 충격공진시험(IR, Impact Resonance)을 도입하였다. 동결 융해 과정에서 수분의 공급이 차단된 폐쇄형 동결조건에서 노상토의 탄성계수는 동결 융해 반복횟수에 무관하게 일정한 값으로 나타났다. 또한 시험에 적용한 모든 함수비 및 다짐도 조건에서 동결전의 탄성계수와 동결 융해 후의 탄성계수는 변화가 거의 없이 일정한 값으로 나타났다. 즉 폐쇄형 동결 융해 조건에서는 노상토의 융해 강성도 감소(thaw-weakening)가 발생하지 않았다. 동결시 탄성계수는 다짐도 및 함수비에 따라서 변화하였으나, 포장설계 관점에서는 무시 가능한 수준으로 나타났다.