• Title/Summary/Keyword: Anti-Windup

Search Result 103, Processing Time 0.026 seconds

Design of the Anti-windup and Bumpless Transfer Controller with Application to Nonlinear Boiler Systems (누적방지 무충돌 전환 제어기의 설계와 비선형 보일러 시스템 적용)

  • Lee, Young-Sam;Lee, Myung-Eui;Kwon, Oh-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.4
    • /
    • pp.247-253
    • /
    • 2000
  • In this paper, we deal with the full range control problem of nonlinear boiler systems subject to complex actuator constraints. Firstly, $H\infty$ loop shaping design procedure[10] is used for the controller design. Secondly, modified high-gain feedback[11] for the loop shaping controller is adopted for the anti-windup function and the bumpless transfer technique between controllers is proposed for the full range control of nonlinear systems. Finally, the performance of the proposed controller is demonstrated through the simulation studies.

  • PDF

Novel Anti-windup Strategy for Complex Vector Synchronous Frame PI Current Controller (복소수 벡터로 설계된 동기 좌표계 비례 적분(PI) 전류 제어기의 안티 와인드업 (anti-windup))

  • Yoo Hyunjae;Jeong Yu-seok;Sul Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.10-13
    • /
    • 2004
  • 본 논문에서는 복소수 벡터 기법으로 설계된 동기 좌표계 비례 적분(PI) 전류 제어기의 새로운 안티 와인드업(anti-windup) 기법을 제안한다. 복소수 벡터로 설계된 동기 좌표계 비례 적분 전류 제어기는 시스템 파라메터(parameter) 변동에 더 강인하다고 알려져 있다. 그러나 이 제어기의 안티 와인드업에 대한 연구는 아직 잘 이루어지지 않았다. 제어기는 그 구조에 따라 알맞은 안티 와인드업이 필요하게 되고, 적절치 못한 안티 와인드업 기법은 제어 시스템의 동특성을 저하시킬 수 있다. 그래서 복소수 벡터로 설계된 동기 좌표계 비례 적분 전류 제어기에 알맞은 안티 와인드업 기법을 제안하였고, 제안된 알고리즘(algorithm)의 유효성은 실험을 통하여 검증하였다.

  • PDF

Dynamical anti-reset windup method for saturating control systems with multiple controllers and multiloop configuration and its application to motor control systems (다중 제어기 및 다중 루우프로 구성된 포화제어시스템의 동적 리셋 와인드엎 방지 방법과 모터제어에의 응용)

  • Park, Jong-Gu;Park, Chong-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.2
    • /
    • pp.141-150
    • /
    • 1998
  • This paper presents a dynamical anti-reset windup (ARW) compensation method for saturating control systems with multiple controllers and/or multiloop configuration. By regarding the difference of controller states in the absence and presence of saturating actuators as an objective function, the dynamical compensator which minimizes the objective function is derived in an integrated fashion. The proposed dynamical compensator is a closed form of plant and controller parameters. The resulting dynamics of compensated controller reflects the linear closed-loop system. The proposed method guarantees total stability of the resulting system. The effectiveness of the proposed method is illustrated by applying it to a servo motor control system. The paper is an extension of the results in Park and Choi[1].

  • PDF

A Position Control of EHA Systems using Adaptive PID Sliding Mode Control Scheme (적응PID 슬라이딩 모드 제어기법을 적용한 EHA 시스템의 위치제어)

  • Lee, Ji-Min;Park, Sung-Hwan;Park, Min-Gyu;Kim, Jong-Shik
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.120-130
    • /
    • 2013
  • An adaptive PID sliding mode controller is proposed for the position control of electro-hydrostatic actuator(EHA) systems with system uncertainties and saturation in the motor. An EHA prototype is developed and system modeling and parameter identification are executed. Then, adaptive PID sliding mode controller and optimal anti-windup PID controller are designed and the performance and robustness of the two control systems are compared by experiment. It was found that the adaptive PID sliding mode control system has better performance and is more robust to system uncertainties than the optimal anti-windup PID control system.

Steady-State Integral Proportional Integral Controller for PI Motor Speed Controllers

  • Hoo, Choon Lih;Haris, Sallehuddin Mohamed;Chung, Edwin Chin Yau;Mohamed, Nik Abdullah Nik
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.177-189
    • /
    • 2015
  • The output of the controller is said to exceed the input limits of the plant being controlled when a control system operates in a non-linear region. This process is called the windup phenomenon. The windup phenomenon is not preferable in the control system because it leads to performance degradation, such as overshoot and system instability. Many anti-windup strategies involve switching, where the integral component differently operates between the linear and the non-linear states. The range of state for the non-overshoot performance is better illustrated by the boundary integral error plane than the proportional-integral (PI) plane in windup inspection. This study proposes a PI controller with a separate closed-loop integral controller and reference value set with respect to the input command and external torque. The PI controller is compared with existing conventional proportional integral, conditional integration, tracking back calculation, and integral state prediction schemes by using ScicosLab simulations. The controller is also experimentally verified on a direct current motor under no-load and loading conditions. The proposed controller shows a promising potential with its ability to eliminate overshoot with short settling time using the decoupling mode in both conditions.

Design of Control Algorithm for Mass Driving Anti-Rolling System Considering Control Input Constraint (제어 입력포화를 고려한 횡동요 저감장치용 제어알고리듬 설계)

  • Moon, Seok-Jun;Lim, Chae-Wook;Lee, Hae-Jong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.6 s.144
    • /
    • pp.566-574
    • /
    • 2005
  • Reduction of a ship's rolling is the most important performance requirement for improving the safety of the crew on board and preventing damage to cargos as well as improving the comfort of the ride. A mass driving anti-rolling system (MO-ARS) might be one candidate of several systems against the ship's rolling. As the movable range of the mass on the ship is finite, the control system must include restriction on the mass position to protect the device and the ship. This restriction usually causes windup phenomenon and control performance is deteriorated seriously. Two control algorithms, anti-windup control and saturated sliding mode control, are studied in this paper. Control performance and robustness problem are checked out by numerical simulations.

Extension of the dynamic anti-reset windup method (다이나믹 리셋 와인드엎 방지방법의 확장)

  • 박종구;최종호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.73-76
    • /
    • 1996
  • This paper presents a dynamical anti-reset windup (ARW) compensation method for saturating control systems with multiple controllers and/or multiloop configuration. By regarding the difference of the controller states in the absence and presence of saturating actuators as an objective function, the dynamical compensator which minimize the objective function are derived in an integrated fashion. The proposed dynamical compensator is a closed form of the plant and controller parameters. The proposed method guarantees total stability of resulting system. An illustrative example is given to show the effectiveness of the proposed method.

  • PDF

Speed Control of Induction Motor Using Anti-windup Integral-Proportional Controller (반포화 적분-비례제어기를 이용한 유도전동기의 속도제어)

  • 정재호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.215-218
    • /
    • 2000
  • The windup phenomenon appears and degrades control performance when a controller with integrating action is used and the plant input is limited. An anti-windup integral -proportional(IP) controller is proposed for the variable-speed motor drives and it is experimentally applied to the speed control of a vector-controlled induction motor driven by a pulse width modulated (PWM) voltage source inverter(VSI). Although the operating conditions like motor load and speed command is changed under the limited plant input it is experimentally verified that the speed response has much improved performance such as no overshoot and fast settling time and the maximum plant input is also effectively utilized.

  • PDF

Steam Temperature Control of Attemperator in Thermal Power Plant (화력발전소에서 과열저감기의 증기온도제어)

  • Shin, Hwi-Beom
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.40-48
    • /
    • 2011
  • An attemperator is a part of the 4-stage superheater in the boiler system of the thermal power plant. The attemperator receives the over-heated steam and makes the steam with proper temperature by adjusting the control valve of the cold steam. In this paper, the attemperator is modeled considering physical point of view and the linearized model is derived for the control purpose. To overcome the integral windup phenomenon due to the opening limitation of the control valve, an anti-windup PI controller is proposed to the attemperator and compared with the PI controller operated in the thermal power plant in view of control performance.

Anti-windup IP Controller for Motor Drives (전동기 구동을 위한 반포화 적분-비례 제어기 설계)

  • 박종규;손병성;유치밍;이순영;신휘범
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.80-83
    • /
    • 1999
  • The windup phenomenon appears and results in performance degradation such as large overshoot, slow settling time when the integral-proportional (IP) controller output is saturated. An anti-windup IP controller is proposed to improve the control performance for the motor drives. The proposed algorithm is applied to the current control of a vector-controlled induction motor driven by a pulse width modulated(PWM) voltage-source inverter. The integral state is separately controlled corresponding to whether the IP controller output is saturated or not. The experimental results show that the current response has much improved performance such as little overshoot and fast settling time.

  • PDF