• Title/Summary/Keyword: Anterior implant

Search Result 438, Processing Time 0.025 seconds

Medpor Craniotomy Gap Wedge Designed to Fill Small Bone Defects along Cranial Bone Flap

  • Goh, Duck-Ho;Kim, Gyoung-Ju;Park, Jae-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.3
    • /
    • pp.195-198
    • /
    • 2009
  • Objective : Medpor porous polyethylene was used to reconstruct small bone defects (gaps and burr holes) along a craniotomy bone flap. The feasibility and cosmetic results were evaluated. Methods : Medpor Craniotomy Gap Wedges, V and T, were designed. The V implant is a 10 cm-long wedge strip, the cross section of which is an isosceles triangle with a 4 mm-long base, making it suitable for gaps less than 4 mm after trimming. Meanwhile, the Medpor T wedge includes a 10 mm-wide thin plate on the top surface of the Medpor V Wedge, making it suitable for gaps wider than 4 mm and burr holes. Sixty-eight pterional craniotomies and 39 superciliary approaches were performed using the implants, and the operative results were evaluated with respect to the cosmetic results and pain or tenderness related to the cranial flap. Results : The small bone defects were eliminated with less than 10 minutes additional operative time. In a physical examination, there were no considerable cosmetic problems regarding to the cranial bone defects, such as a linear depression or dimple in the forehead, anterior temporal hollow, preauricular depression, and parietal burr hole defect. Plus, no patient suffered from any infectious complications. Conclusion : The Medpor Craniotomy Gap Wedge is technically easy to work with for reconstructing small bone defects, such as the bone gaps and burr holes created by a craniotomy, and produces excellent cosmetic results.

Management of open bite that developed during treatment for internal derangement and osteoarthritis of the temporomandibular joint

  • Arai, Chihiro;Choi, Jae Won;Nakaoka, Kazutoshi;Hamada, Yoshiki;Nakamura, Yoshiki
    • The korean journal of orthodontics
    • /
    • v.45 no.3
    • /
    • pp.136-145
    • /
    • 2015
  • This case report describes the orthodontic treatment performed for open bite caused by internal derangement (ID) and osteoarthritis (OA) of the temporomandibular joint (TMJ). A Japanese woman, aged 31 years and 11 months, referred to our department by an oral surgeon had an open bite with clockwise rotation of the mandible and degeneration of the condyle. The overbite was corrected through intrusion of the maxillary and mandibular molars using mini-screw implants to induce counterclockwise rotation of the mandible. Then, the mandibular second premolars were extracted and comprehensive orthodontic treatment was performed to establish a Class I molar relationship with distalization of the maxillary arch and to eliminate anterior crowding. Following treatment, her facial profile improved and a functional and stable occlusion was achieved without recurrence of the TMJ symptoms. These results suggest that orthodontic intrusion of the molars is one of the safer and less stressful alternatives for the management of open bite due to degeneration of the condyles caused by ID and OA of TMJ.

Periodontal attachment loss of extracted teeth for periodontal reasons (발거치에 나타난 부착상실의 양상에 대한 연구)

  • Kim, Jung-Hyun;Kim, Sung-Jo;Choi, Jeom-Il;Lee, Ju-Youn
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.61-68
    • /
    • 2006
  • The factors influencing long-term prognosis of teeth must be carefully considered. Among these, attachment level is strongly associated with tooth loss. The purpose of the present study was to estimate pattern of attachment loss based on attachment area in extracted teeth. 197 satisfied the criteria for assessment after staining. The protocol described by Waerhaug(l975) was performed. An indir ect method, based on digital image abstracted from digital camera and digital imaging software program, was used to calculate the root surface area and the attachment loss area. The data were analysed using SPSS. Except maxillary central incisior and mandibular canine, no statistical significant differences between each root surfaces were observed in anterior teeth. In posterior teeth, statistical significant differences in palatal surface of maxillary molar and mandibular molar compared with others were observed. Statistical significant difference in buccal surface compared with others was lowly observed in single and multi rooted. This study did not reveal progressive loss pattern of attachment area in each root surface but clarified root surface that has relative high loss rate of attachment area at extraction. Thus understanding this pattern of attachment loss is helpful for dentist to treat the periodontitis.

Conservative orthodontic treatment for severe pathologic migration following total glossectomy: A case report

  • Giap, Hai-Van;Jeon, Ji Yoon;Kim, Kee Deog;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.52 no.4
    • /
    • pp.298-307
    • /
    • 2022
  • Glossectomy combined with radiotherapy causes different levels of tongue function disorders and leads to severe malocclusion, with poor periodontal status in cancer survivors. Although affected patients require regular access to orthodontic care, special considerations are crucial for treatment planning. This case report describes the satisfactory orthodontic management for the correction of severe dental crowding in a 43-year-old female 6 years after treatment for tongue cancer with total glossectomy combined with radiotherapy, to envision the possibility of orthodontic care for oral cancer survivors. Extraction was performed to correct dental crowding and establish proper occlusion following alignment, after considering the possibility of osteoradionecrosis. Orthodontic mini-implants were used to provide skeletal anchorage required for closure of the extraction space and intrusion of the anterior teeth. The dental crowding was corrected, and Class I occlusal relationship was established after 36 months of treatment. The treatment outcome was sustained after 15 months of retention, and long-term follow-up was recommended.

Epistaxis in dental and maxillofacial practice: a comprehensive review

  • Psillas, George;Dimas, Grigorios Georgios;Papaioannou, Despoina;Savopoulos, Christos;Constantinidis, Jiannis
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.1
    • /
    • pp.13-20
    • /
    • 2022
  • The lifetime incidence of epistaxis in dental and maxillofacial practice has been reported to be as high as 60% and can be caused by dental implant placement, Le Fort I osteotomy, intranasal supernumerary tooth, odontogenic tumors, blood disorders and maxillofacial trauma. Most epistaxis cases are minor and easily managed with direct compression on the nares for 10 minutes. For more significant or recurrent epistaxis, other techniques might include electrocautery, anterior or posterior nasal packing, or Foley catheter balloon. For patients with refractory epistaxis, cauterization of the sphenopalatine artery under endonasal endoscopy or embolization of the internal maxillary artery should be performed. Epistaxis control is required in patients diagnosed with inherited or acquired bleeding disorders or with drug-induced coagulopathies during dental procedures. In these cases, hemostatic system adjustment and hemostasis achieved by local and adjunctive methods are required. Dentists and maxillofacial surgeons must be aware that the nasal cavity is a potential source of perioperative hemorrhage. Depending on the invasiveness of the dental intervention, preoperative involvement of the hematologist and cardiologist is usually necessary to reverse anticoagulation or to cease anticoagulant therapy.

Revisiting the measurement of keratinized gingiva: a cross-sectional study comparing an intraoral scanner with clinical parameters

  • Ahmet Mert Nalbantoglu;Deniz Yanik
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.362-375
    • /
    • 2023
  • Purpose: The aim of this study was to investigate the relationships between gingival thickness (GT) and keratinized gingiva width (KGW), papilla height (PH), and crown ratio (CR) by employing transgingival probing and an intraoral scanner (IOS). Methods: This cross-sectional study examined 360 maxillary anterior teeth from 60 patients. GT was assessed using transgingival probing with an endodontic spreader. KGW, CR, and PH were measured using an IOS. One-way analysis of variance, the Student's t-test, and Spearman correlation coefficients were employed for statistical analysis. Results: Higher GT was significantly associated with thinner KGW in the central region (P=0.019). There was no statistically significant difference in GT between teeth (P=0.06). PH was lower in lateral teeth than in canines (P=0.047), with a PH of 2.99 mm in lateral teeth. The KGW was narrower in canines than in central teeth (P=0.007). A moderate correlation was observed between KGW and PH in the central region (P=0.01), while a weak negative correlation was found between KGW and CR (P=0.043). Conclusions: A moderate negative correlation was found between GT and KGW, as well as between PH and KGW in central teeth. In contrast, a weak negative correlation existed between CR and KGW. The PH (2.99 mm) was lower in lateral teeth than in canines. The traditional paradigm, which suggests a positive correlation between KGW and GT, was reevaluated by measuring KGW using an IOS.

Stress distribution following face mask application using different finite element models according to Hounsfield unit values in CT images (CT상의 HU 수치에 따른 상악골 전방견인 효과의 유한요소 분석)

  • Chung, Dong-Hwa
    • The korean journal of orthodontics
    • /
    • v.36 no.6
    • /
    • pp.412-421
    • /
    • 2006
  • Objective: The result of finite element analysis depends on material properties, structural expression, density of element, and boundar or loading conditions. To represent proper elastic behavior, a finite element model was made using Hounsfield unit (HU) values in CT images. Methods: A 13 year 6 month old male was used as the subject. A 3 dimensional visualizing program, Mimics, was used to build a 3D object from the DICOM file which was acquired from the CT images. Model 1 was established by giving 24 material properties according to HU. Model 2 was constructed by the conventional method which provides 2 material properties. Protraction force of 500g was applied at a 45 degree downward angle from Frankfort horizontal (FH) plane. Results: Model 1 showed a more flexible response on the first premolar region which had more forward and downward movement of the maxillary anterior segment. Maxilla was bent on the sagittal plane and frontal plane. Model 2 revealed less movement in all directions. It moved downward on the anterior part and upward on the posterior part, which is clockwise rotation of the maxilla. Conclusion: These results signify that different outcomes of finite element analysis can occur according to the given material properties and it is recommended to use HU values for more accurate results.

Axial wall thickness of zirconia abutment in anterior region (전치부 지르코니아 지대주의 축벽 두께)

  • Moon, Seung-Jin;Heo, Yu-Ri;Lee, Gyeong-Je;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.345-351
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the proper axial thickness of zirconia abutment applied to implant in the anterior region. Materials and methods: Zirconia abutments were prepared at different axial wall thickness by processing pre-sintered zirconia blocks via CAD/CAM to obtain equal specimens. The abutments were each produced with a thickness of 0.5 mm (Group 1), 0.8 mm (Group 2), 1.2 mm (Group 3), or 1.5 mm (Group 4). The implant used in this study was a external connection type one (US, Osstem, Pussan, Korea) product and the zirconia abutment was prepared via replication of a cemented abutment. The crowns were prepared via CAM/CAM with a thickness of 1.5 mm and were cemented to the abutments using $RelyX^{TM}$ UniCem cement. A universal testing machine was used to apply load at 30 degrees and measure fracture strength of the zirconia abutment. Results: Fracture strength of the abutments for Group 1, Group 2, Group 3, and Group 4 were $236.00{\pm}67.55N$, $599.00{\pm}15.80N$, $588.20{\pm}33.18N$, and $97.83{\pm}98.13N$, respectively. Group 1 showed a significantly lower value, as compared to the other groups (independent Mann-Whitney U-test. P<.05). No significant differences were detected among Group 2, Group 3, and Group 4 (independent Mann-Whitney U-test. P>.05). Conclusion: Zirconia abutment requires optimal thickness for fracture resistance. Within the limitation of this study, > 0.8 mm thickness is recommended for zirconia abutment in anterior implants.

Stress distribution in bone surrounding maxillary molar implants under different crown-to-fixture ratio: A 3D FEM analysis (치관/고정체 비에 따른 상악 구치부 임플란트 주변골의 응력 분포에 대한 3차원 유한요소법적 분석)

  • Park, Jong-Chan;Shin, Sang-Wan;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.479-489
    • /
    • 2008
  • Statement of the problem: Under anatomical limitations on maxillary posterior region, a poor crown-to root ratio acting on dental implants can result in undesirable stress in surrounding bone, which in turn can cause bone defects and eventual failure of implants. Purpose: The purpose is to compare stress distribution due to different crown-root ratio and effect of splinting between natural teeth and implants in maxillary molar area under different loads. Material and methods: Analysis of stress arising supporting bone of the natural teeth and the implant was made with 3-dimensional finite element method. The model simulated naturel teeth was made with 2nd premolar and 1st molar in the maxillary molar region (Model T). The model simulated implants placed on same positions with two parallel implants of Straumann Dental Implant cemented abutment (Model I). Each model was designed in different crown-root ratio (0.7:1, 1:1, 1.25:1) and set cement type gold crown to make it non-splinted or splinted. After that, 300 N force was loaded to each model in five ways (Load 1: middle of occlusal table, Load 2: middle of buccal cusp, Load 3: middle of lingual cusp, Load 4: horizontal load to buccal cusp of anterior abutment only, Load 5: horizontal load to middle of buccal cusp of each abutment), and stress distribution was analyzed. Results and conclusion: On all occasions, stress was concentrated at the cervical region of the implant. Under load 1, 2 and 3, stress was not increased even when crown-root ratio increases, but under load 4 and 5, when crown-root ratio increases, stress also increased. There was difference in stress values between natural teeth and implants when crown-root ratio gradually increases; In case of natural teeth, splinting decreased stress under vertical and horizontal loads. In case of implants, splinting decreased stress under vertical loads 1,2 and 3, but increased maximal stress under loads 2 and 3. Under horizontal loads, splinting decreased stress, however the effect of splinting decreased under load 5 than load 4. Furthermore, the stress was increased, when crown-root ratio is 1.25:1. Clinical implications: This limited finite element study suggests that the stress on supporting bone may be increased under non-axial loads and poor crown-root ratio. Under poor crown-root ratio, excessive stress was generated at the cervical region of the implant, and decreased splinting effect for stress distribution, which can be related to clinical failure.

COMPARATIVE STUDIES OF RETENTIVE FORCES IN MAXILLARY OVERDENTURE BAR ATTACHMENTS (상악 임플랜트 Overdenture에서 Bar Attachment 설계에 따른 유지력 변화에 관한 연구)

  • Son Cha-Young;Jeong Chang-Mo;Jeon Young-Chan;Lim Jang-Seop;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.650-661
    • /
    • 2005
  • Statement of problem: It could be hypothesised that attachments, which provide more retention against vortical and horizontal dislodgement, will be associated with more favorable parameters of oral function. Purpose: This study was to provide data of initial retentive force and retention loss of different bar attachment systems recommended for use with maxillary implant overdentures. Material and method: 4 implants were placed in the anterior region of edentulous maxilla, five different systems of bar attachment were fabricated as follows: cantilevered Hader bar using clips (Type 1), Hader bar using clips without cantilever (Type 2), Hader bar using clip and ERA attachment orange male (Type 3), Hader bar using clip and ERA attachment white male (Type 4), and Bar using magnets (Type 5). Each samples were placed in the universal testing machine for determination of retentive forces(at initial and after every 200 cycles up to 1,000 cycles). Results and Conclusion 1. Attachment type 1 showed the biggest initial retentive force followed by type 3, type 2, type 4, and lastly type 5(P<0.001). 2. After 1,000 cycles of repeated removals of attachments, significant loss of retentive forces was taken place except for attachment type 5. 3. After 1,000 cycles of repeated removals, the loss of retentive force between type 1 and type 2, which used Hader bar and clip attachments. was greater in type 1 that had wider clip formation. And between type 3 and type 4, which used ERA attachments, the loss of retentive force was greater in type 4 that had white male attached (P<0.001). 4. After 1.000 cycles of repeated removals, attachment type 3 showed the biggest retentive force followed by type 2, type 4, type 1 and lastly type. 5. There was no significant difference between attachment type 3 and 4, and type 4 and 1(P<0.001).