• Title/Summary/Keyword: Anterior implant

Search Result 438, Processing Time 0.023 seconds

The Measurement of Vertical Length from the Root Tip of Maxillary Anterior Teeth to Nasal Floor, When Maxillary Anterior Implants Placed (상악전치부 임플란트 식립 시 상악전치부 치근첨에서 비강저까지 치조골의 수직적 길이 측정)

  • Jang, Hae-Man;Kim, Jin-Wook;Kwon, Tae-Geon;Jang, Hyun-Joong;Kim, Chin-Soo;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.5
    • /
    • pp.326-331
    • /
    • 2012
  • Purpose: Length measurement from maxillary anterior teeth root tip to nasal floor is incorrect in panoramic radiography. Comparison of cone beam computed tomography (CBCT) and panoramic radiography should be helpful in determining the vertical length. Methods: Sixty nine patients were taken CBCT and panoramic radiography of the maxillary anterior. First measurement is length of parallel lines from the central incisor and lateral incisor root tip to nasal floor on CBCT. Second measurement is length of perpendicular lines from the central incisor and lateral incisor root tip to nasal floor on CBCT. Third measurement is length from the central incisor and lateral incisor root tip to nasal floor on panoramic radiographys. Results: In the first measurement of the maxillary central incisors, an average of $11.36{\pm}2.49$ mm in males and $10.49{\pm}2.17$ mm in females. In the second measurement of the maxillary central incisors, $10.41{\pm}2.42$ mm in males and $9.18{\pm}2.08$ mm in females. In the third measurement of the maxillary central incisors, $10.71{\pm}2.20$ mm in males and $9.27{\pm}2.10$ mm in females. In the first measurement of the maxillary lateral incisors, an average of $13.40{\pm}2.04$ mm in males and $11.96{\pm}2.20$ mm in females. In the second measurement of the maxillary lateral incisors, $11.25{\pm}1.82$ mm in males and $10.06{\pm}1.68$ mm in females. In the third measurement of the maxillary lateral incisors, $11.47{\pm}2.01$ mm in males and $10.13{\pm}1.70$ mm in females. Conclusion: The vertical length from root tip to nasal floor was longer in male than female (P>0.05). First measurement was longer than third measurement (P<0.05). This is the actual placement of the implant site measured on the vertical length than the length of the panorama means that there are a few more free. The first measurement was longer than 114% over the third measurement.

A comparative study of bite force associated with remaining bone level in anterior and premolar teeth at periodontal maintenance phase (유지관리기 치주환자의 전치 및 소구치에서 잔존 치조골량에 따른 교합력의 비교 연구)

  • Song, Gyu-Won;Yim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.643-653
    • /
    • 2002
  • Periodontal supporting tissue goes through destruction by chronic inflammatory periodontal disease as two aspect. One is qualitive aspect such as alteration of periodontium, the other is quantitative aspect such as alveolar bone loss. According to many authors, PDL is responsible for biting force, and there are two mean. for measuring PDL's function - mobility test and biting force test. This study was conducted to compare the biting force with remaining bone level, that is, quantitative aspect of periodontium, in anterior and premolar teeth at periodontal maintenance phase. 17 patients on periodontal maintenance phase during 6 months at minimum were selected for this study. For the same condition, 4 anterior, canine, premolar teeth were tested by MPM-3000 bite-force register at the same time(a.m.l0-12), the same position, the same posture, by the same examiner. Patients of TMI), ill-fitting pros thesis, general disease, malocclusion and the teeth of TFO, absence of opposing teeth, malposition were excluded. Remaining bone level was measured on the panorama X-ray film through 5 level from 1mm below CEJ to root apex. Teeth were examined twice, and bigger one was selected. If the values showed large difference. examinatin was re-done and the mean was selected. The results were as follows ; 1. In the 4 anterior group, as the remaining bone is decreased, the average of maximal biting force is decreased. Especially, at 3/5 bone level, maximal biting force is decreased significantly(p<0.01). 2. In the canine group, as the remaining bone is decreased, the average of maximal biting force is decreased. Especially, at 2/5 bone level, maximal biting force is decreased significantly(p<0.01). 3. In the premolar group, as the remaining bone is decreased, the average of maximal biting force is decreased. Especially, at 3/5 bone level, maximal biting force is decreased significantly(p<0.05). From the results of this study, clinicians could utilize these efficiently when they have to determine the proper restorative materials, time for tooth extraction, treatment plan, prognosis.

Modified tunneling technique for root coverage of anterior mandible using minimal soft tissue harvesting and volume-stable collagen matrix: a retrospective study

  • Lee, Yoonsub;Lee, Dajung;Kim, Sungtae;Ku, Young;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.6
    • /
    • pp.398-408
    • /
    • 2021
  • Purpose: In this study, we aimed to evaluate the clinical validity of the modified tunneling technique using minimal soft tissue harvesting and volume-stable collagen matrix in the anterior mandible. Methods: In total, 27 anterior mandibular teeth and palatal donor sites in 17 patients with ≥1 mm of gingival recession (GR) were analyzed before and after root coverage. For the recipient sites, vertical vestibular incisions were made in the interdental area and a subperiosteal tunnel was created with an elevator. After both sides of the marginal gingiva were tied to one another, a prepared connective tissue graft and volume-stable collagen matrix were inserted through the vestibular vertical incision and were fixed with resorbable suture material. The root coverage results of the recipient site were measured at baseline (T0), 3 weeks (T3), 12 weeks (T12), and the latest visit (Tl). For palatal donor sites, a free gingival graft from a pre-decided area avoiding the main trunk of the greater palatine artery was harvested using a prefabricated surgical template at a depth of 2 mm after de-epithelization using a rotating bur. In each patient, the clinical and volumetric changes at the donor sites between T0 and T3 were measured. Results: During an average follow-up of 14.5 months, teeth with denuded root lengths of 1-3 mm (n=12), 3-6 mm (n=11), and >6 mm (n=2) achieved root coverage of 97.01%±7.65%, 86.70%±5.66%, and 82.53%±1.39%, respectively. Miller classification I (n=12), II (n=10), and III (n=3) teeth showed mean coverage rates of 97.01%±7.65%, 86.91%±5.90%, and 83.19%±1.62%, respectively. At the donor sites, an average defect depth of 1.41 mm (70.5%) recovered in 3 weeks, and the wounds were epithelized completely in all cases. Conclusions: The modified tunneling technique in this study is a promising treatment modality for overcoming GR in the anterior mandible.

Can the Zero-Profile Implant Be Used for Anterior Cervical Discectomy and Fusion in Traumatic Subaxial Disc Injury? A Preliminary, Retrospective Study

  • Kim, Tae Hun;Kim, Dae Hyun;Kim, Ki Hong;Kwak, Young Seok;Kwak, Sang Gyu;Choi, Man Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.5
    • /
    • pp.574-581
    • /
    • 2018
  • Objective : The zero-profile implant (Zero-P) is accepted for use in anterior cervical fusion for the treatment of degenerative cervical disease. However, evidence pertaining to its efficiency and safety in traumatic cervical injury is largely insufficient. This study aimed to compare the overall outcomes of patients who underwent Zero-P for traumatic cervical disc injury. Methods : Data from a total of 53 consecutive patients who underwent surgery for traumatic or degenerative cervical disc disease using the Zero-P were reviewed. Seventeen patients (group A) had traumatic cervical disc injury and the remaining 36 (group B) had degenerative cervical disc herniation. The fusion and subsidence rates and Cobb angle were measured retrospectively from plain radiographs. The patients' clinical outcomes were evaluated using the Japanese Orthopedic Association (JOA) score and Odom's criteria. Results : The C2-7 Cobb and operative segmental angles increased by $3.45{\pm}7.61$ and $2.94{\pm}4.59$ in group A; and $2.46{\pm}7.31$ and $2.88{\pm}5.49$ in group B over 12 postoperative months, respectively. The subsidence and fusion rate was 35.0% and 95.0% in group A; and 36.6% and 95.1% in group B, respectively. None of the parameters differed significantly between groups. The clinical outcomes were similar in both groups in terms of increasing the JOA score and producing a grade higher than "good" using Odom's criteria. Conclusion : The application of Zero-P in patients with traumatic cervical disc injury was found to be acceptable when compared with the clinical and radiological outcomes of degenerative cervical spondylosis.

Morphometric analysis of maxillary alveolar regions for immediate implantation

  • Park, Man-Soo;Park, Young-Bum;Choi, Hyunmin;Moon, Hong-Seok;Chung, Moon-Kyu;Cha, In-Ho;Kim, Hee-Jin;Han, Dong-Hoo
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.494-501
    • /
    • 2013
  • PURPOSE. The purpose of this study was to provide an actual guideline in determining the shape, diameter, and position of the implant in immediate implantation by the measurement of the thickness of facial and palatal plate, the thickness of cortical bone on the facial and palatal plate, the diameter of the root, and the distance between the roots in the cadavers. MATERIALS AND METHODS. The horizontal sections of 20 maxillae were measured and analyzed to obtain the average values. Resin blocks were produced and cut serially at 1 mm intervals from the cervical line to the root apex. Images of each section were obtained and the following measurements were performed: The thickness of the facial and palatal residual bone at each root surface, the thickness of the facial and palatal cortical bone at the interdental region, the diameter of all roots of each section on the faciopalatal and mesiodistal diameter, and the interroot distance. Three specimens with measurements close to the average values were chosen and 3-dimensional images were reconstructed. RESULTS. The thickness of the facial and palatal cortical bone at the interdental region in the maxilla, the buccal cortical bone was thicker in the posterior region compared to the anterior region. The interroot distance of the alveolar bone thickness between the roots increased from anterior to posterior region and from coronal to apical in the maxilla. CONCLUSION. In this study, the limited results of the morphometric analysis of the alveolar ridge using the sections of maxilla in the cadavers may offer the useful information when planning and selecting optimal implant for immediate implantation in the maxilla.

Reestablishing the occlusal plane in full mouth rehabilitation patient, using Shilla system (전악수복환자에서 Shilla system을 이용한 교합평면 재구성 증례)

  • Yang, Min-Soo;Vang, Mong-Sook;Park, Sang-Won;Lim, Hyun-Phil;Yun, Kwi-Dug;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.33-38
    • /
    • 2013
  • Occlusal plane is a sagittal expression of dental arch form, and it composes the shape of occlusion, which is one of the most important elements of Maxillo-oral system. In this case, vertical, horizontal coordinates of bionic-median-sagittal plane was produced in articulator, and to achieve relation of left and right position of upper, lower teeth and deficits in alveola, Shilla system was used to reconstruct occlusal plane. In this case, a 41 year-old male patient visited for fracture of 10 unit metal-ceramic fixed partial denture of upper anterior teeth and for overall treatment. Clinical, radiographical, model examination was held, full mouth rehabilitation was achieved by placing dental implant. Maxillo-oral relation was recorded using Gothic arch Tracer complex and were mounted. And for the next step, we estimated original occlusal plane using Shilla system. After analysis we produced diagnosis wax pattern. On the basis of this, radiography stent was manufactured and dental implant was placed, and temporary prosthesis was made by using diagnosis wax pattern. Cross mounting and anterior guiding table were performed in order to reproduce temporary restoration morphology and bite pattern, followed by final restoration made of all ceramic crown with zirconia coping. As stated above, appropriately esthetic and functional results can be seen in using Shilla system in diagnosis and treatment procedure of full mouth rehabilitation patient.

Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position

  • Song, Jae-Won;Lim, Joong-Ki;Lee, Kee-Joon;Sung, Sang-Jin;Chun, Youn-Sic;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.46 no.4
    • /
    • pp.242-252
    • /
    • 2016
  • Objective: Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. Methods: Two extraction models were constructed to analyze the three-dimentional finite element: a first premolar extraction model (Model 1, M1) and a residual 1-mm space post-extraction model (Model 2, M2). The OMI position was set at a height of 8 mm from the arch wire between the second maxillary premolar and the first molar (low OMI traction) or at a 12-mm height in the mesial second maxillary premolar (high OMI traction). Retraction force vectors of 200 g from the ARH (-1, +1, +3, and +6 mm) at low or high OMI traction were resolved into X-, Y-, and Z-axis components. Results: In M1 (low and high OMI traction) and M2 (low OMI traction), the maxillary incisor tip was extruded, but the apex was intruded, and the occlusal plane was rotated clockwise. Significant intrusion and counter-clockwise rotation in the occlusal plane were observed under high OMI traction and -1 mm ARH in M2. Conclusions: This study observed orthodontic tooth movement according to the OMI position and ARH height, and M2 under high OMI traction with short ARH showed retraction with maxillary incisor intrusion.

The skeletal cortical anchorage using titanium microscrew implants (Titanium microscrew implant를 이용한 skeletal cortical anchorage)

  • Park, Hyo-Sang
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.699-706
    • /
    • 1999
  • Anchorage plays an important role in orthodontic treatment. Endosseous implants may be considered adequate firm anchorage. However, clinicians have hesitated to use endosseous implants as orthodontic anchorage because of limited implantation space, high cost, and long waiting period before osseointegration occurs. Recently, some clinicians have tried to use titanium miniscrews and microscrews in treatment due to their many advantages such as ease of insertion and removal, low cost, immediate loading, and the ability to place microscrews in any area of alveolar bone. The author treated a case with skeletal cortical anchorage using titanium microscrew implants. During six months of orthodontic force application from skeletal cortical anchorage, the author could get 4 mm bodily retraction and intrusion of upper anterior teeth. The most outstanding result was a 1.5 mm posterior refraction of the upper posterior teeth. The titanium microscrew implants had remained firm and stable throughout treatment. These results indicate that skeletal cortical anchorage might be a very good option.

  • PDF

Biomechanical Testing of Anterior Cervical Spine Implants: Evaluation of Changes in Strength Characteristics and Metal Fatigue Resulting from Minimal Bending and Cyclic Loading

  • Kim, Sung-Bum;Bak, Koang-Hum;Cheong, Jin-Hwan;Kim, Jae-Min;Kim, Choong-Hyun;Oh, Seong-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.3
    • /
    • pp.217-222
    • /
    • 2005
  • Objective: To achieve optimal fit of implant, it is necessary to bend the implant during spine surgery. Bending procedure may decrease stiffness of plate especially made of titanium and stainless steel. Typically titanium suffers adverse effects including early crack propagation when it is bent. We investigate whether 6 degree bending of titanium plates would decrease the stiffness after full cyclic loading by comparing with non-bending titanium plates group. Methods: Authors experimented 40 titanium alloy plates of 57mm in length, manufactured by 5 different companies. Total 40 plates were divided into two groups (20 bent plates for experimental group and 20 non-bent plates for control group). Twenty plates of experimental group were bent to 6 degree with 3-point bending technique and verified with image analyzer. Using the electron microscope, we sought for a initial crack before and after 3-point bending. Mechanical testing by means of 6000 cyclic axial-compression loading of 35N in compression with moment arm of 35mm-1.1 Nm was conducted on each plate and followed by the electron microscopic examination to detect crack or fissure on plates. Results: The stiffness was decreased after 6000 cyclic loading, but there was no statistically significant difference in stiffness between experimental and control group. There was no evidence of change in grain structure on the electron microscopic magnification. Conclusion: The titanium cervical plates can be bent to 6 degree without any crack or weakness of plate. We also assume that minimal bending may increase the resistance to fatigue fracture in cervical flexion-extension movement.

A COMPARISON OF ACCURACY BETWEEN FIXTURE IMPRESSION AND ABUTMENT IMPRESSION FOR DENTAL IMPLANTS (치과 임플랜트용 고정체 인상법과 지대원주 인상법간의 정확성 비교)

  • Choi, Hyun-Sik;Yim, Soon-Ho;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.662-673
    • /
    • 1997
  • The purpose of this study was to compare the accuracy between future impression and abutment impression using strain gauges. The master model used in this study was a partially edentulous mandibular metal cast with two fixture analogs on both sides. On the left, two future analogs were parallel, whereas right side, posterior future analog exhibiting a 15-degree lingual inclination. From master cast, 10 impressions were made for each of the three impression methods. The master frameworks was fabricated on the master model, and two-element strain gauge was attached to a master framework. The master framework was seated on each cast, and gold screws were tightened to 10 Ncm using a torque controller AI-1600 strain measurement system was used for strain measuring. Impression methods studied were : Group 1:abutment impression Group 2:fixture impression Group 3:combined impression (anterior:fixture impression, posterior:abutment impression) The results were as followed. 1. The strain values on X-axis and Y-axis according to the three impression methods showed no significant difference. 2. The strain values on parallel and angulated groups according to the three impression methods showed no significant difference. 3. The parallel group exhibited significantly higher accuracy in adaptation than angulated group for all experimental groups (p<0.05). In conclusion, it is considered that accuracy of implant prostheses is more affected by implant angulation than impression methods.

  • PDF