• Title/Summary/Keyword: Anterior cervical interbody fusion

Search Result 35, Processing Time 0.02 seconds

Analysis of Noninstrumented Anterior Cervical Discectomy and Interbody Fusion in Degenerative Cervical Disease (퇴행성 경추질환에서 전방경유 추간판 절제술 및 골유합술의 결과분석)

  • Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.180-185
    • /
    • 2001
  • Objectives : We retrospectively studied the efficacy of anterior cervical discectomy and interbody fusion without plate fixation in degenerative cervical disease. Methods : Thirty two consecutive patients with degenerative cervical disease treated by decompression and interbody fusion(Smith-Robinson technique) without anterior cervical plating were studied for postoperative complication rate as well as the clinical and radiologic outcomes and were compared the result of ours with other reported series where the anterior cervical plating was used. Results : All cases were reviewed after average period of 13 months for the purpose of this study. There were 4 postoperative complications related to grafting. A solid fusion was obtained in all cases with single-level fusion(n=21) and 81.8 % of the cases with a two-level fusion(n=11). The overall fusion rate was 93.8 % and fusion rate per level fused was 95.3%. The clinical outcome of the patients was comparable with that in the literature, with one patient having a poor result. Comparing the result of this study with others of the anterior cervical plating, clinical outcome and fusion rate were not superior in plate fixation group in single-level fusion, but increased fusion rate and decreased graft-related complication rate were noted in multilevel fusion with plate fixation. However, the clinical outcome was not superior to noninstrumented fusion group of this study. Conclusion : These results demonstrate that anterior cervical discectomy and interbody fusion(Smith-Robinson technique) without instrumentation is safe and reliable method of single-level fusion in degenerative cervical disease. Plate fixation system doesn't seem necessary in single level fusion in degenerative cervical disease.

  • PDF

Long-term Effects on the Cervical Spine after Anterior Locking Plate Fixation (경추 전방 잠금식 금속판이 장기적으로 경추에 미치는 영향)

  • Kim, Keun Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.493-500
    • /
    • 2001
  • Objective : Anterior cervical locking plates are the devices for achieving anterior cervical spinal fusion. This study was conducted to evaluate the locking plate system regarding its long-term advantages and disadvantages in the view of interbody fusion rate, hardware-related failures, vertebral change close to the fusion segment and postoperative complications. Method : Eight-six patients, operated from Jan., 1996 to Jun. 1998, were followed-up for more than two years. All of the cases were fused with iliac bone graft and ORION locking plate(Sofamor Danek USA, Inc., Memphis, TN) fixation. The patients were discharged or transferred to rehabilitation department 2-7 days after operation. A comprehensive evaluation of the interbody fusion state, instrument failure, vertebral change and postoperative complications were made by direct interview and cervical flexion-extension lateral plain films. Results : There were 55 male and 31 female with a mean age of 45 years(18-75 years). The mean follow-up period was 29 months(24-43 months). Various disorders that were operated were 40 cervical discs, 6 cervical stenosis including OPLL, 2 infections, and 38 traumas. Fusion level was single in 59 cases, two levels of each disc space in 15 cases, and two levels after one corpectomy in 12 cases. There was no instrument failure. Pseudoarthrosis was observed in two cases(2%) without radiological instability. The other patients(98%) showed complete cervical fusion with stable instrument. Mild settling of interbody graft with upward migration of screws was found in 12 cases(14%). Anterior bony growth at the upper segment was found in 5 cases(6%). Postoperative foreign body sensation or dysphagia was observed in 12 cases(4%), and disappeared within one month in 7 cases and within six months in 4 cases. One patient complained for more than six months and required reoperation to remove paraesophageal granulation tissue. Conclusion : The results show that Orion cervical locking plate has some disadvantages of upward migration of screws, anterior bony growth at the upper segment, or possibility of esophageal compression even though it has advantages of high interbody fusion rate or low instrument failure. Author believe that anterior cervical locking plate in the future should be thinner, and should have short end from the screw hole, and movable screw with adequate stability.

  • PDF

Anterior Cervical Instrumentation Using Intradiscal Cage with Integrated Plate

  • Ahn, Kyoung-Rok;Ryu, Kyeong-Sik;Chang, In-Bok;Cho, Byung-Moon;Park, Se-Hyuck;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.4
    • /
    • pp.260-264
    • /
    • 2006
  • Objective : The retrospective study is undertaken to report clinical results of anterior cervical interbody fusion with an intradiscal cage with an integrated plate [PCB cervical plating system]. Methods : 38 patients underwent anterior cervical interbody fusion with PCB cervical plating system and followed $6{\sim}24\;months$. The authors investigated overall surgical results; clinical outcome, fusion rate, change of interspace height & lordotic angle, and complications. Results : No complication was observed during the operation. Clinical improvement was identified in 34 cases [89.5%]. Bone fusion observed in 44 out of 49 sites [90.7%]. After operation, the interspace height increased from $5.4{\pm}1.3mm$ to $7.8{\pm}1.5mm$ and maintained $7.4{\pm}1.1mm$ and, interspace angle went up from $4.2{\pm}0.7^{\circ}$ to $4.8{\pm}1.1^{\circ}$ and maintained $4.6{\pm}$0.9^{\circ}. The loosening of screw was observed in 6 cases, one of which had reoperation because of the expulsion of the device accompanied. Conclusion : PCB cervical plating system could restore interbody height and lordosis in anterior cervical interbody fusion. But, if the insertion of the spacer is not precise, the frequencies of hardware failure are relatively high. It is considered necessary for the operator to be careful in the procedure.

Subsidence Ratio after Anterior Cervical Interbody Fusion Using an Intraoperative Custom-made Cervical Cage

  • Kim, Dok-Ryong;Moon, Byung-Gwan;Kim, Jae-Hoon;Kang, Hee-In;Lee, Seung-Jin;Kim, Joo-Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.5
    • /
    • pp.301-305
    • /
    • 2007
  • Objective : The postoperative subsidence of anterior cervical interbody fusion for cervical degenerative diseases gives rise to segmental kyphotic collapse, screw loosening, and chronic neck pain. So, intraoperative custom-made polymethylmethacrylate [PMMA] C-cage has been developed to prevent subsidence following anterior cervical fusion. Methods : A total of patients who underwent anterior cervical interbody fusion with a intraoperative custom - made cervical cage filled with local bone and demineralized bone matrix [group A] were analyzed prospectively from June 2004 to June 2005. These were compared with 40 patients who were treated with iliac bone graft [group B]. We evaluated subsidence ratio, change of segmental angle, distraction length and segmental angle. Statistical analysis was performed using independent sample t-test and Pearson correlation coefficient. Results : Group A had a statistically significant decrease in subsidence ratio [$0.64{\pm}0.43%$, p=0.00]. distraction length [$2.42{\pm}1.25\;mm$, p=0.02], and follow angle change [$1.78{\pm}1.69^{\circ}$, p=0.01] as compared with Group B. However, there was no statistically significant difference in postoperative segmental angle change [p=0.66]. On the analysis of the correlation coefficient, the parameters showed no interrelationships in the group A. On the other hand, subsidence ratio was affected by distraction length in the group B [Pearson correlation=0.448]. Conclusion : This operative technique would be contributed for the reduction of a postoperative subsidence after the anterior cervical interbody fusion procedure for cervical disc disease with moderate to severe osteoporotic condition and segmental loss of lordosis.

Clinical Analysis of Postoperative Prognostic Factors of Cervical Anterior Decompression and Interbody Fusion for Ossification of Posterior Longitudinal Ligament (경추 후종인대 골화증의 전방경유 감압술 및 골 융합술후 예후인자에 대한 임상분석)

  • Sim, Sang Joon;Cho, Jun Ho;Yoo, Soo Il;Kwon, Young Dae;Lee, Yong Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.3
    • /
    • pp.360-364
    • /
    • 2000
  • Objective : To investigate the prognostic factors associated with outcome in patients with ossification of posterior longitudinal ligament. Method : During the past 4 years, we have operated on 35 patients with cervical OPLL. Anterior cervical decompression(total or subtotal corpectomy, discectomy, and removal of the OPLL) and interbody fusion with iliac bone were performed in all patients. Results : Eight cases(22.9%) were continuous type, 11(31.4%) segmental, 13(37.1%) Mixed, and 3(8.6%) localized type. Thirty-two patients(91.4%) showed an excellent or good results. Conclusion : These results indicate that surgical treatment should be considerated in case of clinical grading higher than II and the surgical outcome is worse when duration of preoperative symptom is longer and when percentage of spinal narrowing is higher. Anterior cervical decompression and interbody fusion seems to be a better method in patients with lesions limited to one or two level. Age at surgery did not significantly affect the outcom.

  • PDF

Oral Extrusion of Screw after Anterior Cervical Interbody Fusion

  • Lee, Jin-Soo;Kang, Dong-Ho;Hwang, Soo-Hyun;Han, Jong-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.4
    • /
    • pp.259-261
    • /
    • 2008
  • We present a case of delayed oral extrusion of a screw after anterior cervical interbody fusion in a 68-year-old man with osteoporosis. Fifteen months earlier, he had undergone C5 corpectomy and anterior cervical interbody fusion at C4-6 for multiple spinal stenoses. The patient was nearly asymptomatic, except for a foreign body sensation in his throat. We conclude that the use of a mesh graft or other instrument in elderly patients and those with osteoporosis or problematic bone quality should be considered carefully and that if surgery were to be performed, periodic postoperative follow-up evaluations are mandatory.

Clinical Experience of Anterior Cervical Interbody Fusion with the PCB System (전방 경추 유합술에서의 PCB System의 임상적 경험)

  • Kim, Sung Han;Kim, Ho Jin;Kang, Jae Kyu;Doh, Jong Oung;Lee, Chun Dae
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1170-1176
    • /
    • 2001
  • Objective : The purpose of the study was to evaluate the clinical and radiological results after discectomy and Lubboc bone graft in the surgical management of the cervical diseases with a new titanium interbody implant and integrated screw fixation(PCB) by anterior approach. Methods : The authors retrospectively analyzed 28 cases of anterior cervical fusion with PCB system and Lubboc bone(xeno graft) from september 1998 to december 2000. Twenty-eight patients with cervical diseases underwent decompression cervical lesion and followed from 5 to 27 months with a mean follow-up of 14 months. There patients were evaluated with clinically and radiologically at immediate postoperative period and at 3, 6, 9, and 12 months. Result : The authors investigated the pre- and postoperative intervertebral disc space, clinical outcomes, radiography fusion rate, and Cobb angle in the fixed segments by anterior approach. The lordotic angles and height of disc space were increased after the operation. The clinical outcome of patients follow-up was good or excellent result based on Odom's criteria with improvement of clinical symptom in about 92.9% of the cervical diseases. Two patients showed loosening of the lower and upper cervical screw of PCB instruments, and two patients showed swallowing difficulty and wound infection Conclusion : The PCB system is a new implant for anterior cervical interbody fusion in the degenerative cervical disease and disc herniations. It provides immediate stability and segment distraction. The results of this study indicate that the PCB system is safe, easy handling of hardware, less complications, high fusion rate, and has provide the keeping the intervertebral disc space height and lordotic angles.

  • PDF

PCB Instrumentation with Lubboe Bone in Anterior Cervical Interbody Fusion (PCB 기구와 이종골을 이용한 경추체간 전방 유합술)

  • Park, Jeong Hyun;Oh, Seong Hoon;Yi, Hyeong Joong;Kim, Ju Heon;Kim, Young Soo;Ko, Yong;Kim, Kwang Myung;Oh, Suck Jun
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.11
    • /
    • pp.1284-1290
    • /
    • 2001
  • Objective : PCB cervical instrument is a newly introduced fusion device which comprises cervical plate, cage (spacer) and screw system. It is developed to enhance fusion rate and stability, as well as to reduce complications related to hardware failure. We investigated the efficacy of clinical and radiological results of PCB instrument and Lubboc bone. Methods : From August, 1998 to October, 1999, authors performed 54 cases of anterior cervical interbody fusion with PCB instrument and Lubboc bone. Retrospective analysis was undertaken based on clinical and radiological findings. Clinical improvement was evaluated according to Odom's criteria. Cervical plain films and tomography were taken every 2 months to evaluate the degree of interbody fusion and disc height changes. Results : Bone fusion was observed in 36 cases(90%) over 6 months after operation, and during which time there was no significant interval change. There were 3 cases of hardware dislodgement. Disc height was increased significantly and preserved in all cases. Clinical outcome over good degree was seen more than 94% of patients. Conclusion : Longer follow-up period and comparative studies to similar instrument appear to be necessary, but this instrumentation system has shown high fusion rate and fewer adverse effects in our series. We believe this system might be indicated for the treatment of cervical trauma and degenerative disease in selective cases.

  • PDF

Clinical and Radiologic Assessment for Anterior Cervical Interbody Fusion with Synthetic Cages

  • Shin, Seung-Ho;Lee, Woo-Jong;Eun, Jong-Pil;Choi, Ha-Young;Lee, Jung-Chung
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.2
    • /
    • pp.105-110
    • /
    • 2007
  • Objective : This purpose of this study was to determine the clinical efficiency and applicability, and to analyze the radiologic findings of the anterior cervical approach using two synthetic cages for interbody fusion. Methods : A total of 41 patients with cervical diseases underwent anterior discectomy and interbody fusion with the PEEK $Solis^{TM}$ cage in 21 patients and the carbon composite $Osta-Pek^{TM}$ cage in 20 patients. Outcome assessment was done using Odom's criteria. Radiological assessment was performed with respect to subsidence, bony fusion and lordosis. The mean follow-up period was 13 months. Results : There were 34 [92.9%] successful cases. The average height of the disc space 12 months after surgery compared the height just after surgery was decreased over 3mm in 4 cases, indicating severe subsidence. The use of these synthetic cages have provided the increase in postoperative cervical lordosis. Conclusion : There were no significant differences between the $Solis^{TM}$ and $Osta-Pek^{TM}$ cages on clinical and radiologic outcomes. Both $Solis^{TM}$ and $Osta-Pek^{TM}$ cages showed low subsidences and complications associated with hardware with good clinical outcomes, high fusion rates, restored disc heights, and restored cervical lordosis.

Clinical and Radiological Outcomes of Anterior Cervical Interbody Fusion Using Hydroxyapatite Spacer

  • Kim, Sung-Chul;Kang, Sung-Won;Kim, Se-Hyuk;Cho, Ki-Hong;Kim, Sang-Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.300-304
    • /
    • 2009
  • Objective : This is retrospective study of clinical and radiological outcomes of anterior cervical fusion using Bongros-$HA^{TM}$ (BioAlpha, Seongnam, Korea) which is a type of synthetic hydroxyapatite (HA) spacer to evaluate the efficacy in its clinical application and usefulness as a reliable alternative to autograft bone. Methods : Twenty-nine patients were enrolled in this study and 40 segments were involved. All patients were performed anterior cervical interbody fusion using HA spacer and plating system. Indications for surgery were radiculopathy caused by soft-disc herniation or spondylosis in 18 patients, spondylotic myelopathy in 1 patient, and spinal trauma in 10 patients. Cervical spine radiographs were obtained on postoperative 1day, 1week, and then at 1, 2, 6, and 12 months in all patients to evaluate intervertebral disc height, and the degrees of lordosis. Cervical computed tomography was done at postoperative 12 month in all patients to confirm the fusion status. The mean period of clinical follow-up was 17 months. Results : Complete interbody fusion was achieved in 100% of patients. Preoperative kyphotic deformities were corrected in all cases after surgery. Intervertebral disc height was well maintained during follow up period. There were no cases of graft extrusion, graft deterioration and graft fracture. Conclusion : HA spacer is very efficient in achieving cervical fusion, maintaining intervertebral disc height, and restoring lordosis. When combined with the placement of a cervical plate, immediate stability can be achieved and graft related complication can be prevented.