• Title/Summary/Keyword: Anterior belly

Search Result 32, Processing Time 0.02 seconds

ANALYSIS OF MANDIBULAR MOVEMENT AND MASTICATORY AND STERNOCLEIDOMATOID MUSCLE ACTIVITY REFLECTED BY OCCLUSAL DISTURBANCE ON HABITUAL CHEWING SIDE (습관적 저작측에 부여한 교합장애로 인한 저작근과 흉쇄유돌근 및 하악운동변화에 관한 연구)

  • Oh, Jung-Hwan;Choi, Dase-Gyun;Choi, Boo-Byung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.718-730
    • /
    • 1995
  • This study was performed to measure the mandibular movement and the changes of masicatory and sternocleidomastoid muscle activity reflected by occlusal disturbance during habitual chewing. For this study, 18 subjects(14 males and 4 females with an average age of 24.0) were selected. The impression of each subject were taken for measuring intermolar distance on lower dentition. The activities of masticatory and sternocleidomastoid muscle and the mandibular movement were recorded and analyzed during habitual chewing by means of E.M.G.(electromyograph), E.G.N.(electrognathograph), rotate program in BioPak analyzing system(BioResearch Inc.). The results were as follows : 1. In EMG of the mandibular rest position, the mean value of muscle activites were increased by nocleidomastoid muscle and anterior belly of digastric muscle(0.05

  • PDF

THE INFLUENCE OF METABOLIC ACIDOSIS, AIRWAY RESISTANCE AND VAGOTOMY ON THE DEVELOPMENT OF MOUTH BREATHING (대사성 산증, 기도저항 변화 및 미주신경 절단이 구호흡 발생에 미치는 영향)

  • Son, Woo Sung;Yang, Won Sik
    • The korean journal of orthodontics
    • /
    • v.20 no.1
    • /
    • pp.47-59
    • /
    • 1990
  • Respiration is one of the most important functions which are carried out in stomatognathic system. When nasal orifice is obstructed or the resistance of upper airway is increased mouth breathing is initiated. Mouth breathing is regarded as an important etiologic factor of dentofacial anomalies. This experiment was performed to observe the influences of metabolic acidosis, tracheal resistance and vagotomy on mouth breathing. After rabbits were anesthetized with sodium pentobarbital, a pair of wire electrode was inserted into mylohyoid muscle, anterior belly of digastric muscle and dilator naris muscle to record EMG activity. Femoral vein and artery were cannulated for infusion of 0.3N HCl and collection of blood sample to determine the blood pH, and tracheal intubation was done to control airway resistance. Mouth breathing was induced by metabolic acidosis. Increase of the airway resistance through tracheal cannula intensified the activity of dilator naris, mylohyoid and digastric muscle. The higher the resistance, the larger the EMG amplitude. After bilateral vagotomy, respiratory volume and inspiatory time were increased and the activities of dilator naris, mylohyoid and digastric muscle were strengthened. It was concluded that the muscle activity related to mouth breathing was induced by metabolic acidosis and increase of tracheal tube resistance.

  • PDF

MEASUREMENT OF THE EXCESSIVE STIMULUS TIME AFTER THE SENSORY THRESHOLD LEVEL DURING ELECTRIC PULP TESTING (전기 치수 검사 시 역치 자극 이후 과용(過用) 자극 시간의 측정)

  • Nam, Ki-Chang;Ahn, Seon-Hui;Kim, Soo-Chan;Kim, Deok-Won;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.226-232
    • /
    • 2004
  • Use of electric pulp testing elicits painful response in vital teeth. In this study, we examined the excessive time from pain feeling to stimulation disconnection in clinical situation. D626D (Parkell Inc., USA.) scan type electric pulp tester was used in total of 23 young healthy individuals. Each of the right central incisors and first premolars were used as testing teeth. Stimulation disconnection was achieved by EMG in anterior belly of digastric muscle, finger span, and voice and the excessive stimulation time over the sensory thresh-old was recorded. As a result, we found that the short responses before the stimulation disconnection appeared following order:EMG, finger span, and voice. The EMG disconnection is suggested to be used to reduce the excessive stimulus time in electric pulp testing.

A STUDY ON TEMPOROMANDIBULAR JOINT DYSFUNCTION USING MAGNETIC RESONANCE IMAGING (자기 공명 영상을 이용한 악관절 기능 장애에 관한 연구)

  • Lee Moon Bae;Kim Jae Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.1
    • /
    • pp.29-37
    • /
    • 1992
  • The temporomandibular joint was evaluated using magnetic resonance imaging using a urface coil in 11 patients having reciprocal clicking or locking and compared with the normal joint in five subjects. Serial multisection 3㎜-thick parasagittal, paracoronal, and axial image on both closing and opening mouth were obtained with a 1.5 Tesla MR system and surface coil using CSMEMP, GRASS, MPGR, powerful extensions of fast imaging that is currently under clinical evaluation. MR images obtained were analized correlating with the theory of internal derangement. The obtained results were as follows: 1. The serial findings of structures in joint were determined on the serially sectioned images of joint with reciprocal clicking or locking by CSMEMP and MPGR on closing mouth. 2. The delta shaped white images of synovial fluid in the glenoid fossa and on the posterior surface of condyle were revealed on the parasagittal images by MPGR on opening mouth as in the normal joints. 3. The white image of joint fluid surrounding meniscus was recognized on the paracoronal image by GRASS on opening mouth as in the normal joints. 4. In joints having temporomandibular dysfunction the smooth image of displaced meniscus was recognized, but otherwise in the normal joints the image of muscle was noted on the paracoronal image sectioned at the anterior portion of condyle by GRASS. 5. The more thickened fascial plane between superior and inferior belly of lateral pterygoid muscle was not recognizable in joints having temporomandibular dysfunction than in the normal joints.

  • PDF

A STUDY ON THE EFFECT OF ELECTRO-ACUPUNCTURE ON ORAL PAIN (전기침이 구강동통에 미치는 영향에 관한 연구)

  • Choi, Yong-Sung;Lee, Chang-Seop;Song, Hyeong-Geun;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.3
    • /
    • pp.717-728
    • /
    • 1996
  • The effects of electro-acupuncture on the pain threshold and the amplitude of dEMG(di-gastric EMG) evoked by the noxious electric stimulation on teeth and gingiva in dogs were studied. Experiments were carried out with 10 dogs weighing 5-8kg. Each animal was anestheticed with Entobar given intraperitoneally in an initial dose of 30mg/kg. Maintenance dose of 5mg/kg/hr was given through a cannula, in the femoral vein, as required to keep up light anesthesia. Bipolar stimulating wire electrodes, 0.1mm in diameter, insulated except for tips, were inserted into the upper canine and palatal gingiva. Rectangular aluminium plate electrodes (15$\times$5mm) were placed on acupuncture points, called Yin-Hsiang, located at both sides of the upper jaw. Rectangular biphasic current pulses of 2Hz, with a $250{\mu}sec$ duration, were delivered for 15 minutes. The dEMG activities were recorded from the anterior belly of the digastric muscle(one of the jaw opening muscles) using bipolar wire electrodes. The magnitude of the jaw opening reflex at different intensties of electro-acupuncture(1volt 4volt and 10volt) was estimated by averaging the 30 superimposed dEMGs recorded on an oscilloscope and audiomonitor. Data were analysed statistically with ANOV A and paired t-test. The obtained results were as follows: 1. Pain thresholds were increased 7.7 %, 15.4 %, 17.3 % in the teeth and 11.1 %, 19.0 %, 25.4 % in the gingiva as the intensities of electro-acupuncture increased incrementally. 2. Amplitudes of dEMG were decreaed 8.3%, 22.4%, 27.4% in the teeth and 9.8%, 36.5%, 42.2 % in the gingiva as the intensities of electro-acupuncture increased incrementally. 3. Inhibition of pain responses by the electroacupuncture was more effective in the gingiva than in the teeth.

  • PDF

THE INHIBITORY EFFECT OF LOW FREQUENCY ELECTRICAL STIMULATION ON THE DENTAL AND GINGIVAL PAIN OF DOG (저빈도 전기자극이 개의 치아 및 치은에 대한 동통억제효과)

  • Kweon, Hoon;Song, Hyung-Geun;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.525-536
    • /
    • 1996
  • The purpose of this study was to investigate the effect of electrical anesthesia induced by non-acupuncture point stimulation on inhibition of amplitude of digastric EMG evoked by noxious electrical stimuli in teeth and gingiva. Experiments were performed with dogs anesthetized with intraperitoneal pentobarbital sodium in an initial dose of 30mg/kg. Maintenance doses of 4.0ml/hour were given through a cannula in the femoral vein using a constant infusion pump. Anterior belly of digastric muscle was exposed and a pair of 0.1mm wire electrodes were inserted for E.M.G. recording. Bipolar electrodes were inserted into the labial and lingual surface of upper canine and the labial area of upper gingiva. Noxious stimuli were delivered to the tooth and gingiva through those electrodes by electric stimulator. Non-acupuncture point stimulation of 2Hz was delivered bilaterally to the femoral area. Amplitudes of digastric E.M.G. were measured from the oscilloscope and the monitor connected to amplifier at different intensities of electronic anesthesia of 1 volt, 4 volt and 10 volt. The inhibited rate of the amplitudes of digastric E.M.G. were analysed statistically with paired t-test. The following results were obtained : 1. Non-acupuncture point stimulation with intensities of 1 volt, 4 volt and 10 volt showed the inhibitory effect on pain of 15%, 25% and 16% in teeth and 15%, 18% and 12% in gingiva respectively 2. In tooth, statistical significance was observed between control and each group. In gingiva, there was statistical significance between control and group 1, 2 except group 3 From these results, low frequency electrical stimulation of non-acupuncture point resulted in reducing of dental and gingival pain, it could be used as adjunct to other pain control methods.

  • PDF

Development of an Auto Stimulus Breaker During the Electric Pulp Testing using Human Responses (전기 치수 검사 시 인체 반응을 이용한 자극 제어기의 개발)

  • 남기창;안선희;이승종;김덕원
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.6
    • /
    • pp.43-49
    • /
    • 2004
  • Electric pulp test is a method to examine the vitality of dental pulp using physical and chemical stimulation. During the pulp test, the current stimulates intradental nerve, and it makes patients painful. In this paper, we measured each activating response EMG in anterior belly of digastric muscle, voice, and finger movement during the pulp test by increasing stimulus intensity gradually. We also measured excessive stimulus time from the activating responses (EMG, voice, and finger movement) to the end of the stimulation. We measured and analyzed excessive stimulus time for each stimulus detecting method. As a result, we developed automatic stimulus breaker using the human responses to stimulus during electric pulp test. We reduced the excessive stimulus time by disconnecting the pulp tester stimulus output rapidly in 10 ms after activating human response.

EFFECT OF LOSS OF INCISAL FUNCTION ON THE GROWTH ACTIVITIES AND ULTRASTRUCTURE OF THE CONDYLAR CARTILAGE IN THE RAT (백서에 있어서 incision 중지가 하악두 연골의 성장 및 미세구조에 미치는 영향)

  • Bae, Yong-Chul;Park, Mae-Ja;Joo, Kang;Kyung, Hee-Moon;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.24 no.3 s.46
    • /
    • pp.569-586
    • /
    • 1994
  • The purpose of this study is to investigate the effect of loss of incisal function on the thickness, growth activities, ultrastructure of the condylar cartilage and on the muscle fibers of masseter superlicialis, anterior belly of digastric muscle in the growing rats. 37 day-old-rats of which incisors had been trimmed every day received soft diet from weaning and were studied by the autoradiography, electron microscopy and muscle histochemistry. The results obtained were as follows : The thickness of the fibrous, proliferative layer in superior, posterosuperior portion of the condylar cartilage was significantly(p<0.01) reduced in experimental groups and the decrease rate of fibrous layer thickness was greater in posterosuperior portion than in superior portion of cartilage and was greater than in proliferative layer. In normal group, more cells of posterosuperior portion moved more rapidly towards the medullary cavity. In experimental group, the labelling index of posterosuperior portion was decreased in proliferative layer at 2 hours, in transitional layer at 1, 2 days, in hypertrophic layer at 4 days after injection relative to posterosuperior portion of control group. But labelling index of superior portion was not different from that of control group at all time course after injection. From the muscle histochemistry, the diameter of type IIB fibers in masseter superficialis muscle, type IIA, type IIB fibers in anterior belly of digastric muscle decreased significantly(p<0.01) relative to controls in experimental group. From electron microscopic study, in the fibrous layer of the posterosuperior portion of condylar cartilage in normal group, many fibroblast like cells near the joint cavity showed extensive remodelling activities in ultrastructure. There was no morphological changes between experimental and control group in all cartilage cell layers of superior portion but cells near the joint cavity in fibrous layer of posterosuperior portion of experimental group showed morphologically inactive state relative to control group.

  • PDF

CHANGES OF JAW-OPENING REFLEX DEGREE ACCORDING TO ELECTROACUPUNCTURE DURATION ON ZUSANLI (족삼리의 전기침 자극에 대한 개구반사 크기의 변화)

  • Seo, Young-Ah;Song, Hyung-Geun;Na, Chang-Su;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.4
    • /
    • pp.788-796
    • /
    • 1998
  • The purpose of this study was to investigate the effect of various electroacupuncture duration induced by acupuncture point-Zusanli ($S_{36}$) electrical stimulation on inhibition of amplitude of digastric electromyogram (dEMG) evoked by noxious electrical stimuli around the mental foramen. intraperitoneal sodium pentobarbital in an initial dose of 50mg/kg and maintenance doses of 4.5mg/kg/h were given through a cannula in the femoral vein using a constant infusion pump. A pair of stimulating electrodes were inserted for noxious stimuli around the mental foramen. An irritant electronic stimuli pulse (0.2 Hz, 0.1 ms duration) was produced with an intensity of about $1.5{\times}2$ times threshold for evoking the dEMG. The anterior belly of the digastric muscle was exposed and a pair of 0.1mm wire electrodes were inserted for dEMG recording. Acupuncture point stimulation on Zusanli (2 Hz, 250 ${\mu}s$, biphasic pulse, 2 V) was delivered by Dental Electronic Anesthesia (3M, U.S.A). For periods of electronic stimulation of 10, 20, and 30min, the amplitudes of dEMG were measured on the oscilloscope and on the monitor connected to the amplifier. The following results were obtained: The dEMG was decreased to 73.4% of that in the control set after 10 min electroacupunture stimulation (Group I); The dEMG was decreased to 77.1% (10min), 54.0.% (20min) of that in the control set after 20minutes of electroacupunture stimulation (Group II). The dEMG was decreased to 73.3% (10min), 61.9% (20min), 76.2% (30min) of that in the control set after 30 min of electroacupunture stimulation (Group III). From these results, it may be that in the electroacupuncture stimulation on the Zusnali resulted in a reduction of amplitude of dEMG and that the most effective electroacupuncture stimulation period was 20min.

  • PDF

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • Physical Therapy Korea
    • /
    • v.18 no.4
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.