• Title/Summary/Keyword: Anterior approach

Search Result 478, Processing Time 0.024 seconds

Subclavian Portal Approach for Isolated Subscapularis Tendon Tear - Technical Note - (견갑하 건 단독 파열에 대한 쇄골하 삽입구를 이용한 봉합술 - 술기보고 -)

  • Choi, Chang-Hyuk;Kim, Shin-Kun;Chang, Il-Woong;Kim, Se-Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.221-225
    • /
    • 2009
  • Purpose: For an isolated tear of the subscapularis tendon, the presented technique using a subclavian portal provides both a good angle for anchor placement and sufficient space for managing the upper portion of a subscapularis tendon tear. Materials and Methods: The conventional method needs 2 additional portals for traction, debriding the footprint and anchor fixation for repair. The presented technique requires only an anterior portal for suture management and a subclavian portal without cannula for suture anchoring and placement of suture hooks. Results: The two suture limbs of the anchor can be placed on the subscapularis tendon by the switching technique and these limbs are repaired sequentially. Conclusion: This technique is simple and reproducible and it can be applied to partial tears and minimally retracted subscapularis tears.

Robotic lower pelvic port placement for optimal upper paraaortic lymph node dissection

  • Paek, Jiheum;Kang, Elizabeth;Lim, Peter C.
    • Journal of Gynecologic Oncology
    • /
    • v.29 no.6
    • /
    • pp.87.1-87.4
    • /
    • 2018
  • Objective: Upper paraaortic lymph node dissection (UPALD) to the infrarenal level is one of the most challenging robotic procedures. Because robotic system has the limitation in robotic arm mobility. This surgical video introduces a novel robotic approach, lower pelvic port placement (LP3), to perform optimally and simultaneously both UPALD and pelvic procedures in gynecologic cancer patients using da Vinci Xi system. Methods: The patient presented with high-grade endometrial cancer. She underwent robotic surgical staging operation. For the setup of the LP3, a line was drown between both anterior superior iliac spines. At 3 cm below this line, another line was drown and four robotic ports were placed on this line. Results: After paraaortic lymph node dissection (PALD) was completed, the boom of robotic system was rotated $180^{\circ}$ to retarget for the pelvic lateral displacement. Robotic ports were placed and docked again. The operation was completed robotically without any complication. Conclusion: The LP3 was feasible for performing simultaneously optimal PALD as well as procedures in pelvic cavity in gynecologic cancer patients. The advantage of LP3 technique is the robotic port placement that affords for multi-quadrant surgery, abdominal and pelvic dissection. The LP3 is facilitated by utilizing advanced technology of Xi system, including the patient clearance function, the rotating boom, and 'port hopping' that allows using every ports for a camera. The LP3 will enable surgeons to extend the surgical indication of robotic surgical system in the gynecologic oncologic field.

Meshed Acellular Dermal Matrix for Two-Staged Prepectoral Breast Reconstruction: An Institutional Experience

  • Luo, Jessica;Willis, Rhett N. Jr;Ohlsen, Suzanna M.;Piccinin, Meghan;Moores, Neal;Kwok, Alvin C.;Agarwal, Jayant P.
    • Archives of Plastic Surgery
    • /
    • v.49 no.2
    • /
    • pp.166-173
    • /
    • 2022
  • The introduction of acellular dermal matrix (ADM) to breast reconstruction has allowed surgeons to reexplore the prepectoral implant placement technique in postmastectomy breast reconstruction. Our institution adopted a novel approach using meshed ADM to lessen the financial burden of increased ADM utilization with the prepectoral breast reconstruction. This is a retrospective, single-center review of two-stage prepectoral breast reconstruction using meshed human-derived ADM for anterior prosthesis coverage. Patient demographics, oncologic data, perioperative characteristics, and complications were examined and reported as means with standard deviations. Cost-saving with the meshed technique was evaluated. Forty-eight patients (72 breasts) with a mean age of 48.5 ± 15.0 years (range 26-70 years) were included in the study. The mean follow-up time was 13.2 ± 4.4 months (range 4.1-25.8 months). Nineteen breasts (24.6%) experienced complications, with seromas being the most common complication (12.5%, n = 9). Expander removal and reoperation occurred at a rate of 8.3 and 9.7%, respectively. The average time to drain removal was 18.8 ± 6.6 days (range 8-32 days). Meshed ADM provided an average cost savings of $6,601 for unilateral and $13,202 for bilateral reconstructions. Our study found that human-derived meshed ADM can be safely used in two-staged prepectoral tissue expander-based breast reconstruction and can result in significant cost savings.

Comparison of treatments for maxillary full denture and mandibular implant-supported fixed prosthesis in completely edentulous patients: A case report (완전 무치악 환자에서 상악 총의치와 하악 임플란트 지지 고정성 보철 치료를 위한 치료법 비교: 증례 보고)

  • Jin-Won Han;Se-Wook Pyo;Jae-Seung Chang;Sunjai Kim
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.73-81
    • /
    • 2023
  • There are various approaches to treatment for patients with fully edentulous jaw. In maxilla, it is easy to obtain sufficient stability, support, and retention with the traditional full denture method. In mandible, however, there are difficulties caused by anatomical limitations. In this case, treatment with implants can be considered. If it is difficult to place implants in posterior area, a fixed complete denture can be considered, using 4 - 5 implants anterior to mental foramen. This approach has changed in many ways, such as surgical methods and materials used, over the years. This case report compares two approaches and their changes over time, especially in the cases of mandibular fixed prostheses using implants, paired with maxillary complete denture.

Automatically Diagnosing Skull Fractures Using an Object Detection Method and Deep Learning Algorithm in Plain Radiography Images

  • Tae Seok, Jeong;Gi Taek, Yee; Kwang Gi, Kim;Young Jae, Kim;Sang Gu, Lee;Woo Kyung, Kim
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.1
    • /
    • pp.53-62
    • /
    • 2023
  • Objective : Deep learning is a machine learning approach based on artificial neural network training, and object detection algorithm using deep learning is used as the most powerful tool in image analysis. We analyzed and evaluated the diagnostic performance of a deep learning algorithm to identify skull fractures in plain radiographic images and investigated its clinical applicability. Methods : A total of 2026 plain radiographic images of the skull (fracture, 991; normal, 1035) were obtained from 741 patients. The RetinaNet architecture was used as a deep learning model. Precision, recall, and average precision were measured to evaluate the deep learning algorithm's diagnostic performance. Results : In ResNet-152, the average precision for intersection over union (IOU) 0.1, 0.3, and 0.5, were 0.7240, 0.6698, and 0.3687, respectively. When the intersection over union (IOU) and confidence threshold were 0.1, the precision was 0.7292, and the recall was 0.7650. When the IOU threshold was 0.1, and the confidence threshold was 0.6, the true and false rates were 82.9% and 17.1%, respectively. There were significant differences in the true/false and false-positive/false-negative ratios between the anterior-posterior, towne, and both lateral views (p=0.032 and p=0.003). Objects detected in false positives had vascular grooves and suture lines. In false negatives, the detection performance of the diastatic fractures, fractures crossing the suture line, and fractures around the vascular grooves and orbit was poor. Conclusion : The object detection algorithm applied with deep learning is expected to be a valuable tool in diagnosing skull fractures.

An Unconventional Approach Considering Flexor Spasticity and Flexion Synergies of the Upper Extremity Following a Stroke: A Randomized Double-blind Pilot Study

  • Rha, Young Hyoun;Lee, Keun Hee;Shin, Jun Bum;Park, Kang Hui;Kim, Byung Sun;Ha, Jae Chan
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.147-155
    • /
    • 2022
  • Background: Although various conventional approaches have been employed to reduce spasticity in neurological rehabilitation, only a few studies have shown scientific evidence for its effectiveness. Thus, we introduced a different concept (Ueda method) of rehabilitation therapy that can complement the limitations of conventional therapy. Objects: This study aimed to investigate the immediate effects of the application of the Ueda method on patients with spasticity after stroke via an electrophysiological study. Methods: We conducted a randomized double-blind pilot study in two rehabilitation hospitals involving 30 stroke patients who were randomly allocated to the Ueda (n = 15) and convention (n = 15) groups. Electromyographic data of six examined muscles in both upper extremities of all patients were recorded. The A-ApA index and activation ratios of upper extremity muscles were evaluated and compared between the groups to confirm post-intervention changes in upper-extremity flexor spasticity and flexion synergies. Repeated-measures analysis of variance was conducted to confirm the therapeutic effect (2 × 2) as a function of group (Ueda vs. convention) and time (pre-/post-intervention) on all outcome measures (p < 0.05). Results: In the Ueda group, the mean A-ApA index values differed significantly before and after the intervention (p = 0.041), indicating a weak evidence level; however, the effect size was medium (d = -0.503). The interaction effects of the A-ApA index between the Ueda and convention groups and between pre-intervention and post-intervention stages were significant (p = 0.012). The effect size was large (np2 = 0.220). In the Ueda group, the activation ratios of the anterior deltoid fiber significantly decreased after the intervention in all reaching tasks. Conclusion: The Ueda method reduces upper-extremity flexor spasticity and changes its synergy in stroke patients and should be considered a rehabilitation therapy for spastic stroke patients.

Voxel-wise Mapping of Functional Magnetic Resonance Imaging in Impression Formation

  • Jeesung Ahn;Yoonjin Nah;Inwhan Ko;Sanghoon Han
    • Science of Emotion and Sensibility
    • /
    • v.25 no.4
    • /
    • pp.77-94
    • /
    • 2022
  • Social interactions often involve encountering inconsistent information about social others. We conducted a functional magnetic resonance imaging (fMRI) study to comprehensively investigate voxel-wise temporal dynamics showing how impressions are anchored and/or adjusted in response to inconsistent social information. The participants performed a social impression task inside an fMRI scanner in which they were shown a male face, together with a series of four adjectives that described the depicted person's personality traits, successively presented beneath the image of the face. Participants were asked to rate their impressions of the person at the end of each trial on a scale of 1 to 8 (where 1 is most negative and 8 is most positive). We established two hypothetical models that represented two temporal patterns of voxel activity: Model 1 featured decreasing patterns of activity towards the end of each trial, anchoring impressions to initially presented information, and Model 2 showed increasing patterns of activity toward the end of each trial, where impressions were being adjusted using new and inconsistent information. Our data-driven model fitting analyses showed that the temporal activity patterns of voxels within the ventral anterior cingulate cortex, medial orbitofrontal cortex, posterior cingulate cortex, amygdala, and fusiform gyrus fit Model 1 (i.e., they were more involved in anchoring first impressions) better than they did Model 2 (i.e., showing impression adjustment). Conversely, voxel-wise neural activity within dorsal ACC and lateral OFC fit Model 2 better than it did Model 1, as it was more likely to be involved in processing new, inconsistent information and adjusting impressions in response. Our novel approach to model fitting analysis replicated previous impression-related neuroscientific findings, furthering the understanding of neural and temporal dynamics of impression processing, particularly with reference to functionally segmenting each region of interest based on relative involvement in impression anchoring as opposed to adjustment.

Case Report on the Five-year Survival of a Patient with Rectal Cancer Treated with Integrative Medicine After Resection and Chemoradiation Therapy (수술 및 항암 방사선 표준 치료 이후의 한양방 통합치료를 통해 5년 무병생존에 도달한 3기 직장암 환자 1례에 대한 보고)

  • Beom-Jin Jeong;Jisoo Kim;Yu-jin Jung;Kyung-Dug Park;Yoona Oh;Sunhwi Bang
    • The Journal of Internal Korean Medicine
    • /
    • v.44 no.3
    • /
    • pp.578-584
    • /
    • 2023
  • Objectives: This is a five-year survival and complete response (CR) report on rectal cancer treated with western medicine and Korean traditional medicine. Method: A 25-year-old woman diagnosed with rectal cancer visited ⃝⃝ Korean traditional medicine hospital after neoadjuvant concurrent chemoradiation therapy, chemotherapy, and low anterior resection with regional lymph node dissection. She was treated with Korean traditional medicine, including acupuncture, abdominal moxibustion, wild ginseng pharmacopuncture, and herbal medicine, which was based on integrated medicine therapy (IMT), from January 2018 to February 2022. The tumor size was measured by scanning with computed tomography (CT), magnetic resonance imaging, and positron-emission tomography/CT. Adverse events were evaluated using laboratory conclusion and National Cancer Institute Common Terminology Criteria for Adverse Events version 5.0. Result: During four years of treatment, IMT maintained safety. The patient finally reached five-year survival without any recurrence or complication (CR) on March 11, 2022. Conclusion: We suggest that an integrative approach including Korean traditional medicine can be a meaningful treatment option for rectal cancer. Further studies should be performed to establish the proper treatment protocol of integrative medicine for rectal cancer.

Implant placement with inferior alveolar nerve repositioning in the posterior mandible

  • Doogyum Kim;Taeil Lim;Hyun-Woo Lee;Baek-Soo Lee;Byung-Joon Choi;Joo Young Ohe;Junho Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.49 no.6
    • /
    • pp.347-353
    • /
    • 2023
  • This case report presents inferior alveolar nerve (IAN) repositioning as a viable approach for implant placement in the mandibular molar region, where challenges of severe alveolar bone width and height deficiencies can exist. Two patients requiring implant placement in the right mandibular molar region underwent nerve transposition and lateralization. In both cases, inadequate alveolar bone height above the IAN precluded the use of short implants. The first patient exhibited an overall low alveolar ridge from the anterior to posterior regions, with a complex relationship with adjacent implant bone level and the mental nerve, complicating vertical augmentation. In the second case, although vertical bone resorption was not severe, the high positioning of the IAN within the alveolar bone due to orthognathic surgery raised concerns regarding adequate height of the implant prosthesis. Therefore, instead of onlay bone grafting, nerve transposition and lateralization were employed for implant placement. In both cases, the follow-up results demonstrated successful osseointegration of all implants and complete recovery of postoperative numbness in the lower lip and mentum area. IAN repositioning is a valuable surgical technique that allows implant placement in severely compromised posterior mandibular regions, promoting patient comfort and successful implant placement without permanent IAN damage.

Leksell Frame-Based Stereotactic Biopsy for Infratentorial Tumor : Practical Tips and Considerations

  • Tae-Kyu Lee;Sa-Hoe Lim;Jangshik Jeong;Su Jee Park;Yeong Jin Kim;Kyung-Sub Moon;In-Young Kim;Shin Jung;Tae-Young Jung
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.2
    • /
    • pp.249-256
    • /
    • 2024
  • The Leksell frame-based transcerebellar approach was proposed with the arc support frame attached upside down to the Z coordinate. This study presented practical tips and considerations for obtaining adequate tissue samples for deep-seated cerebellar lesions or lower brainstem lesions specifically those accessible via the cerebellar peduncle. For practical insights, the Leksell coordinate frame G was fixed to prevent the anterior screw implantation within the temporalis muscle, to avoid interference with the magnetic resonance (MR)-adapter, and taking into account the magnetic field of MR in close proximity to the tentorium. After mounting of indicator box, the MR imaging evaluation should cover both the indicator box and the infratentorial region that deviated from it. The coordinates [X, Y, Za, Arc0, Ringa0] obtained from Leksell SurgiPlan® software (Elekta, Stockholm, Sweden) with arc 00 located on the patient's right side were converted to [X, Y, Zb=360-Za, Arc0, Ringb0=Ringa0-1800]. The operation was performed in the prone position under general anesthesia in four patients with deep cerebellar (n=3) and brainstem (n=1) tumors. The biopsy results showed two cases of diffuse large B-cell lymphoma, one metastatic braintumor and one glioblastoma. One patient required frame repositioning as a complication. Drawing upon the methodology outlined in existing literature, we anticipate that imparting supplementary expertise could render the stereotactic biopsy of infratentorial tumors more consistent and manageable for the practitioner, thereby facilitating adequate tissue samples and minimizing patient complications.