• Title/Summary/Keyword: Antenna site

Search Result 106, Processing Time 0.023 seconds

The Study on Empirical Propagation Path Loss in the Airport Cargo Terminal Environment (공항 화물터미널 환경에서 실험적인 패스 로스에 관한 연구)

  • Kim, Kyung-Tae;Park, Hyo-Dal
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.12
    • /
    • pp.1140-1147
    • /
    • 2013
  • In this paper, The path loss model of Air Traffic Control(ATC) telecommunication radio channel has been studied at the Incheon International Airport(IIA) Cargo Terminal. We measured one frequency among VHF channel bands. The transmitting site was located at different locations with different heights. The transmitting site radiated the Continuous Wave(CW). The propagation measurement was taken using the moving vehicle equipped with receiver and antenna. The transmitting power, frequency and antenna height are the same as the current operating condition. The path loss exponent and intercept parameters were extracted by the basic path loss model and hata model. The path loss exponent at IIA Cargo terminal area were 3.67 and 3.39 respectively in first and second transmitting sites. The deviation of prediction error is 14.42 and 10.38. The new path loss equation at the IIA Cargo terminal area was also developed using the derived path loss parameters. The new path loss was compared with other models. This result will be helpful for the ATC site selection and service quality evaluation.

Correction of Coordinate Discontinuities Caused by GPS Antenna Replacements

  • Kim, Dusik;Park, Kwan-Dong;Won, Jihye
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.4 no.3
    • /
    • pp.131-140
    • /
    • 2015
  • Antennas at permanent GPS stations operated by the former Ministry of Government Administration and Home Affairs (MOGAHA) in Korea were replaced in years 2008 and 2009, and these changes caused abrupt discontinuities in precise coordinate time series. In this study, an algorithm that eliminates those breaks was developed based on 15-year-long coordinate time series for the purpose of creating clean and continuous coordinate time series. The newly developed algorithm to correct for sudden jumps and dips in the GPS time series due to the antenna change was designed to consider all the linear and annual signals observed before and after the event. The accuracy of the new algorithm was confirmed to be at the Root Mean Square Error (RMSE) level of 2.3-2.6 mm. The new algorithm was also found to be capable of reflect site-specific characteristics at each station.

Frequency response of Sensors for GIS insulation-diagnosis (GIS 절연진달을 위한 센서 구조별 주파수 특성)

  • Choi, Eun-Hyeok;Kim, Jung-Bae;Kim, Gi-Chai;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.413-416
    • /
    • 2007
  • If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulities to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important. The strip-senser measured impedance bandwidth of the proposed antenna is from 0.5[GHz] to 2.5[GHz] with the stop band from 0.5[GHz] to 1.7[GHz] for VSWR<2. The antenna is will play an important role for the senser for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

  • PDF

Adaptive Filtering Processing for Target Signature Enhancement in Monostatic Borehole Radar Data

  • Hyun, Seung-Yeup;Kim, Se-Yun
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.2
    • /
    • pp.79-81
    • /
    • 2014
  • In B-scan data measured by a pulse-type monostatic borehole radar, target signatures are seriously obscured by two clutters that differ in orientation and intensity. The primary clutter appears as a nearly constant time delay, which is caused by internal ringing between antenna and transceiver in the radar system. The secondary clutter occurs as an oblique time delay due to the guided borehole wave along the logging cable of the radar antenna. This issue led us to perform adaptive filtering processing for orientation-based clutter removal. This letter describes adaptive filtering processing consisting of a combination of edge detection, data rotation, and eigenimage filtering. We show that the hyperbolic signatures of a dormant air-filled tunnel target can be more distinctly enhanced by applying the proposed approach to the B-scan data, which are measured in a well-suited test site for underground tunnel detection.

Improvement of duty rate of Meteor Burst communication with Buried Antenna (매설형 안테나를 이용한 유성 버스트 통신의 도통율 개선)

  • 김병철;이영철;김기채
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.254-260
    • /
    • 1999
  • Meteor Burst Communication can provide effective and economical means of communication where long distance VHF NLOS data transmission is needed; often ranges more than 1000 km. It has been, however, so far considered unsuitable for short distance application because of phenomenal decrease in burst durations, which leads to decreation of total duty rate of the system. This paper extensively analyzes characteristics of shot distance MB(Meteor Burst) path and shows the low duty rate may be improved by increasing burst rate through adapting antenna beam width to cover entire hot-spot region in the space and, by compensating effective burst length through cutting down man-made noises introduced by antenna. Based on the analysis, we are developed a small-opening-cavity antenna, especially designed for short distance MB path. In operation, the antenna is to be buried under ground surface so as to improve directivity and reduces noise introduction. The antenna exhibits power gain of 3 dB with 90 degree beam width and thus enables to illuminate entire hot-spot regions with the elevation angle of 8-90 degree which is the case of transmission less than 100 km. Directivity horizontal to earth surface is suppressed to minimum which enables to cut man-made noises from near-by sources down to more than 3 dB from the level reported with conventional 4 element Yagi. A series of experiments performed on 100 km MB paths have conformed that, with the antenna installed at receiving site, the burst rate and duration time have been noticed to increase by 10 and 20 percent respectively from the values obtained by conventional 4-element Yagi antenna under same testing condition.

  • PDF

A study of ubiquitous-RTLS system for worker safety (작업자 안전관리를 위한 유비쿼터스-실시간 위치추적시스템 연구)

  • Kim, Young-Baig
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.1C
    • /
    • pp.1-7
    • /
    • 2012
  • At the industrial work site, the manufacturing process is being automated to improve work efficiency. However, it is often difficult to automate the entire manufacturing process, and there are spaces in which workers there are constantly exposed to danger. To protect such workers from the danger, this paper studied a worker safety management system for the industrial work site which uses a location recognition system and which is based on the Ubiquitous-Wireless Sensor Network (U-WSN). Using wireless signals, the distance between two devices can be measured and the location of a worker can be calculated using triangularization in 3-D. But at the industrial work sites where there are a lot of steel and structures, errors occur due to signal reflection and multi-path, etc., which makes it difficult to get the accurate location. To address this problem the following was done: first, a circular polarization patch antenna appropriate to the work site was used to reduce the degree of error that may occur from the antenna emission pattern and the particular Line of Sight (LOS); second, a 3-D localization technique and a filtering algorithm were used to improve the accuracy of location determination. The developed system was tested by using it on a wharf crane to validate its accuracy and effectiveness. The proposed location recognition system is expected to contribute greatly in ensuring the safety of workers at industrial work sites.

A Study on the Performance Verification Method of an ALSE(Absorber-Lined Shielded Enclosure) by the CISPR25 (CISPR25의 ALSE(Absorber-Lined Shielded Enclosure) 성능 검증 방법에 관한 연구)

  • Shin, Jaekon;Jung, Kibum;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.8
    • /
    • pp.791-797
    • /
    • 2013
  • This paper proposes a new way to verify the performance of an absorber lined shielded enclosure(ALSE) in accordance with CISPR25, EMC standards dedicated to testing automotive components. CISPR16 requires the use of NSA and VSWR methods to test the performance of a chamber. As for CISPR25, however, there hasn't been standardized ways to verify the performance of ALSE. This paper purports to present an improved method for the verification based on a long-wire antenna method under discussion at CISPR25 JFT. Existing discussions on a long-wire antenna method proposes that an antenna should reach 500 millimeters in length, while this paper adopts the antenna length of 1,700 millimeters. This paper also assesses the effects of matching conditions and studies problems related to methods which have been already proposed and key parameters in order to improve verification methods.

Home-range Analysis of Pipistrelle Bat (Pipistrellus abramus) in Non-Reproductive Season by Using Radio-tracking (원격무선추적을 이용한 집박쥐의 비번식기 행동권 분석)

  • Chung, Chul-Un;Han, Sang-Hoon;Lee, Chong-Il
    • Korean Journal of Environment and Ecology
    • /
    • v.24 no.4
    • /
    • pp.487-492
    • /
    • 2010
  • This study was conducted to analyze the home range size of Pipistrellus abramus in non-reproductive season. The survey was conducted in the day-roosting site of Pipistrellus abramus located in Gyeongju City(North Gyeongsang Province). We radio-tracked six Pipistrellus abramus(male 3, female 3) and LTM single stage radio transmitter(0.38g), R2000 ATS receiver, three element yagi antenna, roof mounted antenna and ArcGIS 3.3(ESRI, Animal Movement Extension 2.0) were used to locate bats and home range analyze. The home range sizes of the 6 radio-tracked Pipistrellus abramus ranged from 8.97 to 19.07ha(Maen $14.46{\pm}3.44ha$). Mean home range size of female($16.83{\pm}1.96ha$) was larger than that of male($12.08{\pm}2.96ha$) but there were no significant differences in home range sizes between male and female(t=2.32, p>0.05). Also, mean maximum distances from the roost was $468.73{\pm}94.38m$ but there were no significant differences between sexes(female, $422.73{\pm}10.38m$; male, $514.74{\pm}125.74m$; t=-1.26, p>0.05).

Advances in Imaging of Subsurface Archaeology using GPR

  • Goodman Dean;Nishimur Yasushi;Schneider Kent;Piro Salvadore;Hongo Hiromichi;Higashi Noriaki
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.8-21
    • /
    • 2004
  • Examples of GPR survey results at a variety of archaeological sites are presented. Several new analyses which include static corrections for the tilt of the GPR antenna are shown for imaging of burial mounds with significant topography. Example archaeological site plans developed from GPR remote sensing of Roman and Japanese sites are given. The first completely automated GPR survey, using only Global Positioning Satellite navigation to create 3D data volumes, is employed for a site in Louisiana to detect lost graves of the Choctaw Indian Tribe.

  • PDF

A Study on Siting Criteria for GBAS Ground System (GBAS 지상시스템 설치후보지 선정 기준에 관한 연구)

  • Jeong, Myeong-Sook;Ko, Youri;Choi, Chul Hee;Ko, Wan-Jin;Bae, Joongwon;Jun, Hyang-Sig;Kim, Dong-Min
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.20 no.3
    • /
    • pp.8-15
    • /
    • 2012
  • Since the site chosen for GBAS ground system will have a direct effect on the performance of the GBAS, the GBAS ground system siting is mightily important in the GBAS installation process. Therefore, in this paper, the major equipment of the GBAS ground system is introduced and a formal process is described for the identification and evaluation of candidate GBAS sites. Also, this paper described detail siting requirements for the GBAS ground system such as reference receiver, VDB antenna and shelter respectively.