• 제목/요약/키워드: Antecedent Rainfall

검색결과 117건 처리시간 0.029초

유역내 네가지 강수손실 성분들의 합성 (Combining Four Elements of Precipitation Loss in a Watershed)

  • 유주환
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2012년도 학술발표회
    • /
    • pp.200-204
    • /
    • 2012
  • In engineering hydrology, an estimation of precipitation loss is one of the most important issues for successful modeling to forecast flooding or evaluate water resources for both surface and subsurface flows in a watershed. An accurate estimation of precipitation loss is required for successful implementation of rainfall-runoff models. Precipitation loss or hydrological abstraction may be defined as the portion of the precipitation that does not contribute to the direct runoff. It may consist of several loss elements or abstractions of precipitation such as infiltration, depression storage, evaporation or evapotranspiration, and interception. A composite loss rate model that combines four loss rates over time is derived as a lumped form of a continuous time function for a storm event. The composite loss rate model developed is an exponential model similar to Horton's infiltration model, but its parameters have different meanings. In this model, the initial loss rate is related to antecedent precipitation amounts prior to a storm event, and the decay factor of the loss rate is a composite decay of four losses.

  • PDF

식생밭두렁과 실트펜스를 이용한 밭 비점오염 저감효과 평가 (Evaluation for Non-Point Sources Reduction Effect by Vegetated Ridge and Silt Fence)

  • 김동현;김상민
    • 한국농공학회논문집
    • /
    • 제57권5호
    • /
    • pp.129-137
    • /
    • 2015
  • The objective of this study was to test the non-point source pollution (NPS) control by the vegetated ridge and silt fence through field monitoring. The experiment plots were established with three sizes which are 5 m width by 22 m length with 8 %, 3 % slope and 15m width by 15 m length with 6 % slope. Flumes with the floating type stage gages were installed at the outlet of each plot to monitor the runoff. For a rainfall monitoring, tipping bucket rain gage was installed within the experiment site. Water quality samples were monitored during the heavy rainfall occurred. The amount of rainfall from 4 monitored events ranged from 27.6 mm to 130 mm. The runoff reduction rate could vary depending on slope, soil, crop growth condition, rainfall amount, rainfall intensity, antecedent moisture condition, and many other factors. The runoff from vegetated ridge and silt fence treatment plots was 24.05 % and -8.28 % lower than that from control plot, respectively. The monitoring results showed that the average pollution loads reduced by vegetated ridge compared to control were BOD 36.62~53.60 %, SS 40.41~73.71 %, COD 39.34~56.41 %, DOC 49.08~53.67 %, TN 26.74~67.23 %, and TP 52.72~91.80 %; by silt fence compared to control were SS 41.73 %, COD 1.93 %, and TN 2.38 %. The paired t-test result indicated that the vegetated ridge and silt fence were statistically significant effect in SS load reduction, with a 5 % significant level. Monitored results indicated that vegetated ridge and silt fence were both effective to reduce the pollutant from the field surface runoff.

강우유출수 처리목적 인공습지의 강우시 오염물질 저감특성에 관한 연구 (Reduction Efficiency of the Stormwater Wetland from Animal Feeding-Lot)

  • 박기수;우사평;김영철
    • 한국습지학회지
    • /
    • 제15권1호
    • /
    • pp.79-90
    • /
    • 2013
  • 가축사육지역으로부터 발생되는 강우유출수 처리를 위해 건설된 인공습지에 대해 2010년 5월부터 2011년 11월까지 수행한 20회의 강우시 모니터링을 통하여 얻은 자료를 분석한 결과 강우시 저감효율은 TSS 88%, BOD 54%, $COD_{Mn}$ 35%, $COD_{Cr}$ 70%, TN 31%, TP 64%이었다. 이론적으로 강우계급의 증가(강우유출량 증가)는 습지의 수리학적 교환비율을 증가시키기 때문에 TSS 저감효율은 감소해야하는데 교환비율이 1에 접근하였을 때 대략 55%의 효율을 달성하였다. 또한 연속적인 강우활동, 개별적인 강우사상의 대소, 강도, 선행건기 일수 등 습지에서는 실험자가 제어할 수 없는 수많은 자연변수들이 복합적으로 작용하기 때문에 처리효율의 변동이 매우 컸다. 효율에 가장 큰 영향을 미친 요인으로는 수리학적 요인과 함께 조류증식이 성능 불확실성에 크게 기여하였다.

HYDROLOGIC IMPACT ASSESSMENT OF LAND COVER CHANGES BY 2002 TYPHOON RUSA USING LANDSAT IMAGES AND STORM RUNOFF MODEL

  • Lee, Mi-Seon;Park, Geun-Ae;Kim, Seong-Joon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.539-542
    • /
    • 2006
  • To investigate the streamflow impact of land cover changes by a typhoon, WMS HEC-1 storm runoff model was applied by using land cover information before and after the typhoon. The model was calibrated with three storm events of 1985 to 1988 based on 1985 land cover condition for a 192.7 $km^2$ watershed in northeast coast of South Korea. After the model was tested, it was run to estimate impacts of land cover change by the typhoon RUSA occurred in 2002 (31 August - 1 September) with 897.5 mm rainfall. The land covers before and after the typhoon were prepared using Landsat 7 ETM+ of September 11 of 2000 and Landsat 5 TM of September 29 of 2002 respectively. For the 6.9 $km^2$ damaged area (3.6 % of the watershed), the peak runoff and total runoff by the changed land cover condition increased 12.5 % and 12.7 % for 50 years rainfall frequency and 1.4 % and 1.8 % for 500 years rainfall frequency respectively based on AMC (Antecedent Moisture Condition)-I condition.

  • PDF

남사천 하류지역 홍수피해 분석 (The Analysis for Flood Damage on Nam-sa Down Stream Region)

  • 김가현;이영대;서진호;민일규
    • 한국환경과학회지
    • /
    • 제10권3호
    • /
    • pp.217-223
    • /
    • 2001
  • Where no records are available at a site, a preliminary estimate may be made from relations between floods and catchment chatacteristics. A number of these chatacteristics were chosen for testing and were measured for those catchments where mean annual flood estimates were available. Although the improvement using extended data in regression of flood estimates on catchment characteristics was small, this may be due to the limitations of the regression model. When an individual short term record is to be extended, more detailed attention can be given; an example is presented of the technique which should be adopted in practice, particularly when a short term record covers a period which is known to be biassed. A method of extending the peaks over a threshold series is presented with a numerical example. The extension of records directly from rainfall by means of a conceptual model is discussed, although the application of such methods is likely to be limited by lack of recording raingauge information. Methods of combining information from various sources are discussed in terms of information from catchment characteristics supplemented by records. but are generally applicable to different sources of information. The application of this technique to estimating the probable maximum flood requires more conservative assumptions about the antecedent condition, storm profile and unit hydrograph. It is suggested that the profile and catchment wetness index at the start of the design duration should be based on the assumption that the estimated maximum rainfall occurs in all durations centered on the storm peak.

  • PDF

Hydrologic Impact Assessment of land Cover Changes by 2002 Typhoon RUSA Using Landsat Images and Storm Runoff Model

  • Lee, Mi-Seon;Park, Geun-Ae;Kim, Seong-Joon
    • 대한원격탐사학회지
    • /
    • 제22권5호
    • /
    • pp.407-413
    • /
    • 2006
  • To investigate the streamflow impact of land cover changes by a typhoon, HEC-l storm runoff model was applied by using land cover information before and after the typhoon. The model was calibrated with three storm events of 1985 to 1988 based on 1985 land cover condition for a $192.7km^{2}$ watershed in northeast coast of South Korea. After the model was tested, it was run to estimate impacts of land cover change by the typhoon RUSA occurred in 2002 (31 August-1 September) with 897.5 mm rainfall. The land covers before and after the typhoon were prepared using Landsat 7 ETM+ of September 11 of 2000 and Landsat 5 TM of September 29 of 2002 respectively. For the $6.9km^{2}$ damaged area (3.6 % of the watershed), the peak runoff and total runoff by the changed land cover condition increased 12.5 % and 12.7 % for 50 years rainfall frequency and 1.4 % and 1.8 % for 500 years rainfall frequency respectively based on AMC (Antecedent Moisture Condition)-I condition.

실시간 유출예측을 위한 선행강우지수별 TF모형의 유도 (Derivation of Transfer Function Models in each Antecedent Precipitation Index for Real-time Streamflow Forecasting)

  • 남성우;박상우
    • 대한토목학회논문집
    • /
    • 제12권1호
    • /
    • pp.115-122
    • /
    • 1992
  • 실시간 유출예측에서 주로 쓰이는 추계학적 강우-유출 과정모형은 모형구조가 간단하고 상태 공간 모형으로 수식화하기에 용이한 TF모형이다. 이 모형을 이용하여 실시간 유출예측을 효율적으로 수행하기 위해서는 정확한 모형구조의 결정이 선행되어야 하며, 특히 예측초기의 오차를 줄일 수 있는 방법이 요구된다. 본 연구에서는 이를 위하여 유역의 초기습윤상태를 나타낼 수 있는 5일 선행강우지수를 threshold개념으로 도입하고, 각각의 TF모형을 Box-Jenkins 방법으로 등정하여 비교 검토하여 보았다.

  • PDF

도시지역 토지이용에 따른 비점원 오염물질 유출특성 (Stormwater Runoff Characteristics of Non-point Source Pollutants according to Landuse of Urban Area)

  • 정동환;신동석;류덕희;정동일
    • 환경영향평가
    • /
    • 제16권6호
    • /
    • pp.525-532
    • /
    • 2007
  • In order to establish and implement the total maximum daily load (TMDL) management plan in Korea, it is necessary to set the source units and calculate discharge loads for non-point source pollutants such as BOD, COD, SS, TN and TP. This study analysed the corelation between stormwater runoff characteristics and event mean concentrations (EMCs) of non-point source pollutants. As the result of the corelation analysis, we knew that all the antecedent dry days (ADD) and the rainfall correlated lowly with non-point source pollutants in the urban areas such as resident area, industrial area, business area, road area and parking area. Therefore, it is necessary to get all samples from stormwater starting point to stormwater ending point and standardize the sampling method of stormwater in order to obtain more accurate EMCs for landuse.

CN값 산정을 위한 적정 선행강우일수의 결정 (Determination of Suitable Antecedent Rainfall Days for Curve Number Estimation)

  • 이명우;최승안;김형수;심명필
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.553-557
    • /
    • 2005
  • 유역의 강우-유출 분석에서 유효우량의 산정은 매우 중요하다고 할 수 있다. 이러한 유효우량의 산정에서 대상호우에 대한 유출량 자료가 있는 경우는 침투지수법(infiltration index method)중 하나인 $\Phi$-지표법이나 W-지표법을 사용하여 그 양을 산정할 수 있다. 그러나 대상호우에 대한 유출량 자료가 없는 경우는 침투지수법을 이용하여 유효우량을 산정 할 수 없으며, 이러한 경우 유역의 토양 특성과 식생피복 상태에 대한 자료만으로 총우량으로부터 유효우량을 산정할 수 있는 NRCS(Natural Resources Conservation Service)의 유효우량 산정방법이 널리 사용되고 있다. NRCS유효우량 산정 방법은 선행토양함수조건(antecedent moisture condition, AMC)을 이 용하여 유출곡선지수(runoff curve number, CN)를 결정하는데, 이때 AMC의 산정을 위해 선행5일강우량(total 5-day antecedent rainfall)을 그 기준으로 하고 있으나, 이는 미국의 유역을 대상으로 하여 얻어진 결과이므로 이를 국내 유역에 검증 없이 적용하는 데에는 문제가 있을 것으로 예상되었다. 따라서 본 연구에서는 HEC-HMS모형을 이용하여 선행강우일수을 변화시켜 가면서 실제 유역의 강우-유출에 적용하여 본 뒤 강우-유출을 가장 잘 모의하는 선행강우일수을 결정하였다. 이를 위해, IHP 대상유역인 보청천의 탄부소유역에 대하여 AMC의 산정을 위한 선행강우량을 1일부터 7일까지 변화시키며 적용한 결과 탄부소유역에서는 선행2일강우량이 가장 적합한 결과를 주는 것으로 나타났다. 국내 유역에서 NRCS유효유량 산정방법을 통한 강우-유출모의시 보다 정확한 값을 산정하기 위해서는 대상유역에 적합한 선행 강우일수의 결정이 중요하리라 판단된다.인 분석을 수행하고, 배수갑문 개방에 의한 수질개선효과를 최대화하기 위한 환경관리 방안 제시에 중점을 두어 수행하였다.ncy), 환경성(environmental feasibility) 등을 정성적으로(qualitatively) 파악하여 실현가능한 대안을 선정하였다. 이렇게 선정된 대안들은 중유역별로 검토하여 효과가 있을 것으로 판단되는 대안들을 제시하는 예비타당성(Prefeasibility) 계획을 수립하였다. 이렇게 제시된 계획은 향후 과학적인 분석(세부평가방법)을 통해 대안을 평가하고 구체적인 타당성(feasibility) 계획을 수립하는데 토대가 될 것이다.{0.11R(mm)}(r^2=0.69)$로 나타났다. 이는 토양의 투수특성에 따라 강우량 증가에 비례하여 점증하는 침투수와 구분되는 현상이었다. 경사와 토양이 같은 조건에서 나지의 경우 역시 $Ro_{B10}(mm)=20.3e^{0.08R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히 교사들이 중요하게 인식하는 해방적 행동에 대한 목표를 강조하여 적용할 필요가 있음을 시사하고

  • PDF

산사태 모니터링 오탐지율 개선을 위한 토양수분자료 활용에 관한 연구 (A study of applying soil moisture for improving false alarm rates in monitoring landslides)

  • 오승철;정재환;최민하;윤홍식
    • 한국수자원학회논문집
    • /
    • 제54권12호
    • /
    • pp.1205-1214
    • /
    • 2021
  • 강수는 공극수압의 상승에 관여해 토양 강도 및 응력의 변동을 발생시켜 산사태의 주요 원인 인자 중 하나로 지목된다. 따라서 강수는 산사태 발생 임계값 산정에 빈번히 사용되나, 지반 안정성을 직접적으로 산정하고 예측하기에는 무리가 있어 오탐지 사건에 대한 분석에는 한계가 있다. 한편 토양수분은 공극수압의 변동에 보다 직접적인 연관성을 지니므로, 다수의 연구에서 지반 안정성의 정량적인 평가에 활용된 바 있다. 이에 본 연구에서는 산사태 발생에 대한 임계값 산정에 있어 토양수분 인자 활용의 적정성을 평가하고자 하였다. 먼저 두 수문 인자의 거동 분석을 통해 강수에 대한 토양 포화도의 반응성을 파악하고, 선행 강수지수(Antecedent Precipitation Index)를 활용해 산사태 발생 임계값을 산정하였다. 이후 토양 포화도를 활용하여 산사태 발생 임계값을 산정했으며, 분할표를 활용해 두 임계값을 정성적으로 평가하였다. 그 결과, 일 강수량(Pdaily)을 단일 인자로 사용해 결정된 산사태 발생 임계값 대비 괴산읍에서는 각각 75% (API), 42% (SM)의 향상을 보였고 창수면에서는 각각 33% (API), 44% (SM)의 향상을 보였다. 따라서 토양수분과 선행 강수지수 모두 임계성공지수(Critical Success Index)를 효과적으로 향상시켰으며 오탐지율을 감소시켰다. 추후 토양 포화도를 통해 산사태 발생에 요구되는 강우 강도를 산정하는 연구와 토양 포화도 수준에 따른 강우 저항성을 산정하는 연구 등 토양수분 자료를 다각적으로 접목한 연구가 수행된다면 산사태 예측 정확성을 향상시키는 데 기여할 수 있을 것으로 보인다.