• Title/Summary/Keyword: Anoxic-anaerobic-aerobic process

Search Result 33, Processing Time 0.025 seconds

Nitrification and Denitrification of Land-based Fish Farm Wastewater using an Anaerobic-Aerobic Upflow Biological Aerated Filter (혐기-호기 상향류 필터 공정에서 양식배출수의 질산화 및 탈질 연구)

  • Park, Noh-Back;Lee, Hyun-Young;Kim, Seong-Min;Lee, Jun-Sang
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.5
    • /
    • pp.622-629
    • /
    • 2014
  • This study induced biological denitrification and nitrification via a biofiltration process with the view of removing nitrogen from land-based fish farm effluent. To achieve this, we operated an aquaculture nitrogen-removal system that includes a denitrification and nitrification reactor [working volume 40 L, flow rate 64.8 L, HRT (hydraulic retention time) 14.8 h, HRT considering recycling of NOx 7.4 h]. In the continuous process, the nitrification rate of ammonium nitrogen exceeded 90% at a steady state and the denitrification efficiency exceeded 80% with recycling to a pre-anoxic reactor. In addition, the pH in the final effluent was lower with a low influent water alkalinity averaging 100 mg/L (as $CaCO_3$). For effective denitrification reactions, carbon must be supplied via particulate organic matter (POM) hydrolysis because of the low C/N (carbon/nitrogen) ratio in the water.

Estimation of greenhouse gas (GHG) emission from wastewater treatment plants and effect of biogas reuse on GHG mitigation

  • Chang, Jin;Kyung, Daeseung;Lee, Woojin
    • Advances in environmental research
    • /
    • v.3 no.2
    • /
    • pp.173-183
    • /
    • 2014
  • A comprehensive mathematical model was developed for this study to estimate on-site and off-site GHG emissions from wastewater treatment plants (WWTPs). The model was applied to three different hybrid WWTPs (S-WWTP, J-WWTP, and T-WWTP) including anaerobic, anoxic, and aerobic process, located in Seoul City, South Korea. Overall on-site and off-site GHG emissions from S-WWTP, J-WWTP, and T-WWTP were $305,253kgCO_2e/d$, $282,682kgCO_2e/d$, and $117,942kgCO_2e/d$, respectively. WWTP treating higher amounts of wastewater produced more on-site and off-site GHG emissions. On average, the percentage contribution of on-site and off-site emissions was 3.03% and 96.97%. The highest amount of on-site GHG emissions was generated from anoxic process and the primary on-site GHG was nitrous oxide ($N_2O$). Off-site GHG emissions related to electricity consumption for unit operation was much higher than that related to production of chemicals for on-site usage. Recovery and reuse of biogas significantly reduced the total GHG emissions from WWTPs. The results obtained from this study can provide basic knowledge to understand the source and amount of GHG emissions from WWTPs and strategies to establish lower GHG emitting WWTPs.

A Study on the treatment efficiency of A2O Process coupled with Mesh Screening Reactor (Mesh Screening Reactor와 결합된 A2O 공정의 처리효율에 관한 연구)

  • Whang, Gye-Dae;Lim, Dong-Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.6
    • /
    • pp.705-714
    • /
    • 2008
  • Three Mesh Screenning Reactors (MSRs) were operated in three different modes to investigate the effect of the mesh opening size and the filtrate flux on the removal of particulate matters and the production of soluble organic matters. The mesh opening size was $82{\mu}m$ (Mode 1), $61{\mu}m$ (Mode 2) and $38{\mu}m$ (Mode 3), respectively, and each mode has three different filtrate flux; $0.47m^3/m^2/d$, $0.95m^3/m^2/d$ and $1.42m^3/m^2/d$, respectively. TSS removal efficiency of mode 1, 2, and 3 fed with 191 mgTSS/L was 27%, 36%, and 60%, respectively. The SCOD concentration of 91mg/L in influent for the mode 1, 2, and 3 increased to 117 mg/L, 127 mg/L, and 155 mg/L, respectively. For the all MSRs, there was no significant effect of filtrate flux on the removal of particulate matters and the production of soluble organic matters. However, the mesh opening size greatly affected the removal of particulate matters and the production of soluble organic matters in wastewater. Three parallel A2O processes consisting of anaerobic, anoxic and aerobic reactors maintaining mixed liquor suspended solids (MLSS) of 3,000 mg/L were operated to investigate the effectiveness of MSR on the removal efficiencies of the organic matters, nitrogen, and phosphorus; MSR influent was introduced to System 1 (183 mgTSS/L, 324 mgTCOD/L, 87 mgSCOD/L, 45.2 mgTKN/L, and 6.6 mgTP/L) and MSR efluent was introduced to System 2 and 3(72 mgTSS/L, 289 mgTCOD/L, 141 mgSCOD/L, 40.2 mgTKN/L, and 4.2 mgTP/L). HRTs of the anaerobic reactors in systems 1, 2 and 3 were 1 h, 1 h and 0.6 h, respectively and anoxic reactors were 2 h in all systems. HRTs of the aerobic reactors in systems 1, 2 and 3 were 5 h, 3 h and 3 h, respectively. TSS concentration in effluent of both system 2 and 3 is about 8 mg/L and lower than that of system 1 effluent. Despite higher TCOD loading and SCOD loading, both Systems 2 and 3 had a greater TCOD and SCOD removal efficiency at 91% and 92% than System 1 was at 88% and 82%, respectively. The nitrification efficiency for system 2 was greater than observed for System 1 (99% verses 97%). The denitrification efficiency for systems 1, 2 and 3 was 78%, 88% and 87%, respectively. System 2 and 3 showed about 12% higher TN removal efficiency than system 1 (85% verses 73%). The effluent TP concentration for system 2 was less than observed for system 1 and 3.

Evaluation of Operational Options of Wastewater Treatment Using EQPS Models (EQPS 모델을 이용한 하수처리장 운전 평가)

  • Yoo, Hosik;Ahn, Seyoung
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.401-408
    • /
    • 2018
  • EQPS (Effluent Quality Prediction System, Dynamita, France) was applied to analyze the appropriateness of the design of a bioreactor in A sewage treatment plant. A sewage treatment plant was designed by setting the design concentration of the secondary clarifier effluent to total nitrogen and total phosphorus, 10 mg/L and 1.8 mg/L, respectively, in order to comply with the target water quality at the level of the hydrophilic water. The retention time of the 4-stage BNR reactor was 9.6 hours, which was 0.5 for the pre-anoxic tank, 1.0 for the anaerobic tank, 2.9 for the anoxic tank, and 5.2 hours for the aerobic tank. As a result of the modeling of the winter season, the retention time of the anaerobic tank was increased by 0.2 hours in order to satisfy the target water quality of the hydrophilic water level. The default coefficients of the one step nitrification denitrification model proposed by the software manufacturer were used to exclude distortion of the modeling results. Since the process modeling generally presents optimal conditions, the retention time of the 4-stage BNR should be increased to 9.8 hours considering the bioreactor margin. The accurate use of process modeling in the design stage of the sewage treatment plant is a way to ensure the stability of the treatment performance and efficiency after construction of the sewage treatment plant.

Characteristics of Biological Nitrogen Removal for Low C/N Ratio Municipal Wastewater Using Methanol as an External Carbon Source in $A_2O$ Fluidized Media Process (유동여재 $A_2O$공정에서 외부탄소원으로 메탄올을 이용한 낮은 C/N비 하수의 생물학적 질소제거 특성)

  • Yoon, Cho-Hee;Kim, Min-Soo;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.687-692
    • /
    • 2006
  • This experiment was performed to evaluate the characteristics of BNR system performance, behavior of pollutants as organic and nitrogen at each basin and the effects of C/N ratio on biological nitrogen removal with methanol as an external carbon source for a low C/N ratio municipal wastewater. A lab-scale $A_2O$ system by employing the aerobic basin with the fluidized polyurethane media, which was $10{\sim}20$ mm rube type like a sponge, was used. The aerobic basin was hybrid type to be suspended and fixed biomass. The obtained results from this study were as follows; When no methanol was added, suspended biomass was 3 times more than that of the fluidized media in this system(total biomass 80 g). Biomass growed by an external carbon was firstly attached on media, and then suspended. $COD_{Cr}$ concentration for the effluent was a range of 13 to 29 mg/L regardless of pouring an external carbon. For nitrogen, the effluent concentration was $20.0{\sim}35.9mg/L$(removal efficiency; 18%) in case of no addition of an external carbon, but was $2.5{\sim}9.0mg/L$(removal efficiency ; $71{\sim}83%$) with addition of methanol. For the characteristics of pollutants removal, most of $COD_{Cr}$ were removed at the anaerobic basin when no external organic carbon was added, and were removed at the anoxic basin in case of adding external organic carbon but at the aerobic basin in case of adding excess external organic carbon. On the other hand, most TIN(total inorganic nitrogen) were removed at the anaerobic basin when no external organic carbon was added, but when an external organic carbon was added, they were removed at the anaerobic basin under unstable condition and at the anoxic basin under stable condition.

Feasible monitoring of the inhibitory effects of free NH3 on NO2- oxidation

  • Yoo, Byeong-Hak;Lee, Sang-hun
    • Geosystem Engineering
    • /
    • v.21 no.5
    • /
    • pp.243-250
    • /
    • 2018
  • This study investigated nitrite ($NO_2{^-}$) accumulation due to FA (Free Ammonia: $NH_3$) inhibition in an anaerobic-aerobic-anoxic (AOA) process reactor to mainly treat wastewater containing 302-610 mg/L of $NH_3/NH_4{^+}-N$. Based on an experimental operation focusing on the nitrification, it was observed that $NO_2{^-}$ was accumulated in the aerobic nitrification zone as pH increased, due to inhibition of $NO_2{^-}$ conversion to $NO_3{^-}$ by FA. This result implied FA inhibition to NOB ($NO_2{^-}$-Oxidizing Bacteria) for converting $NO_2{^-}$ to $NO_3{^-}$. The objective of this study is to develop a feasible monitoring procedure for early detection of the FA inhibition toward $NO_2{^-}$ accumulation and poor nitrification. Thus, in order to rapidly assess FA concentrations, an $NH_3$ probe was utilized to measure $NH_3$ concentrations together with applying a simple model prediction using the measured $NH_4{^+}$ concentrations, the Henry's law constant of $NH_3$ and measured pH. The predictive model $NH_3$ levels were verified by a good correlation (89%) with the corresponding measured data, but the model prediction underestimated FA concentrations at less than 7.4 and a little overestimated at pH above 7.5. Interestingly, accumulated $NO_2{^-}$ levels were roughly correlated with FA levels that were observed at delayed time points. This reflects the detected FA levels can be good indicators of $NO_2{^-}$ levels with some delayed time. $NO_2{^-}$ accumulation started at measured FA concentrations of higher than approximately 3 mg/L and ceased below that FA level.

Application of the Hybrid Constructed Wetland for a Reuse of the Effluent from Bio-industrial Wastewater Treatment Plant (바이오산업폐수처리수의 재이용을 위한 hybrid 인공습지 시스템의 적용가능성 연구)

  • Shin, Jae-Suk;Kim, Sung-Chul;Cho, Kwang-Ju;Choi, Choong-Ho;Choi, In-Wook;Park, Jeong-Ja;Park, Goo-Hyeon
    • Journal of Wetlands Research
    • /
    • v.11 no.1
    • /
    • pp.115-121
    • /
    • 2009
  • The hybrid constructed wetland(HCW) as tertiary treatment process of a bio industrial wastewater treatment plant was employed to estimate applications for the reuse of final effluent. Raw wastewater was sequently treated through chemical and biological treatment processes and the biologically treated water was flowed into the HCW. The HCW system was composed of two constructed wetlands connected in series; The one is the aerobic constructed wetland with natural air draft system whose driving force for air supply was the difference between the temperature of the air inside the wetland and the ambient air, and the other is the anaerobic/anoxic constructed wetland. Average influent concentrations of BOD, SS, T-N and T-P in the HCW were 53mg/L, 48mg/L, 34mg/L and 3mg/L, respectively. After being treated at HCW, final effluent concentrations of BOD, SS, T-N and T-P were 2.3mg/L, 1.2mg/L, 7.95mg/L and 0.83mg/L, respectively. Referring to a reuse standard for a sewage wastewater, final effluent could sufficiently be reuse as landscaping, washing or agriculture water. HCW system with the aerobic/anaerobic combined constructed wetland could be achieved a high removal efficiency because each constructed wetland was functionalized to be removed efficiently organics, nitrogen and phosphorus. HCW system could be estimated to be successful application as tertiary treatment process of a various industrial and municipal wastewater.

  • PDF

Treatability Evaluation of $A_{2}O$ System by Principal Component Analysis (주성분분석에 의한 $A_{2}O$공법의 처리성 평가)

  • 김복현;이재형;이수환;윤조희
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.2
    • /
    • pp.67-74
    • /
    • 1992
  • The lab-scale biological A$_{2}$O system was applied from treating piggery wastewater highly polluted organic material which nitrogen and phosphorous are much contained relatively in conversion with other wastewater. The objective of this study was to investigate the effect of variance parameters on the treatability of this system according to operation conditions. An obtained experimental data were analysed by using principal component analysis (PCA) method. The results are summarized as follows: 1. From Varimax rotated factor loading in raw wastewater, variance of factor 1 was 36.8% and cumulative percentage of variance from factor 1 to factor 4 was 81.5% and of these was related to BOD, TKN and BOD loading. 2. In anaerobic process, variance of factor 1 was 33.5% and cumulative percentage of variance from factor I to factor 4 was 81.8% and of these was related to PO$_{4}$-P, BOD, DO and Temperature. 3. In anoxic process, variance of factor 1 was 30.1% and cumulative percentage of variance from factor i to factor 4 was 84.3% and of these was related to pH, DO, TKN and temperature. 4. In aerobic process, variance of factor 1 was 43.8% and cumulative percentage of variance from factor 1 to factor 4 was 81.5% and of these was highly related to DO, PO$_{4}$-P and BOD. 5. It was better to be operated below 0.30 kg/kg$\cdot$day F/M ratio to keep over 90% of BOD and SS, 80% of TKN, and 60% of PO$_{4}$-P in treatment efficiencies. 6. Treatment efficiencies was over 93% of BOD and SS, 81% of TKN and 60% of PO$_{4}$-P at over 20$^{\circ}$C, respectively.

  • PDF

Effect of Air-flow on Enhanced Nutrient Removal and Simultaneous Nitrification/Denitrification in DMR Biofilm Process (DMR 생물막 공정에서 포기량에 따른 질산화 동시 탈질화 및 영양염류 제거특성)

  • Kim, Il-Kyu;Lee, Sang-Min;Lim, Kyeong-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.10
    • /
    • pp.992-998
    • /
    • 2008
  • Recently, a new concept for nitrogen removal that is simultaneous nitrification and denitrification(SND) has been studied for wastewater treatment process. The DMR(Daiho Microbic Revolution) process that used in this study consists of two suspended anoxic, anaerobic reactors and an aerobic biofilm reactor. The function of aerobic environment and the intensity of air flow rate(2.0, 1.0, 0.5, 0.4, 0.2 L/min) were studied in the biofilm reactor; also SND and nutrient removal efficiencies were investigated. Experimental results indicated that the change in air flow did not affect COD$_{Cr}$ removal significantly. Thus sustained at 93%. The lower the air flow rate, the higher T-N removal efficiency was attained(i.e.80% at 0.2 L/min). SND efficiency was 62, 65, 72 and 78% corresponding to each air flow rate. T-P removal was sensitive to aeration intensity and removal enhanced from 75% to 96% when the air flow rate was changed from 2.0 to 0.5 L/m; however second release occured in the clarifier at 0.2 L/min. Phosphorus content of activated sludge was 5.0%, as P releases and acetate uptake a ratio of 0.75 mg P/ mg HAc.

A Study on the Optical Internal Recycle Rate and MLSS Concentration of Membrane Coupled $A_2O$ Process for Wastewater Treatment (하수처리를 위한 막결합형 $A_2O$공정에서 최적 내부 순환율 및 MLSS 농도에 관한 연구)

  • Kim Kwan-Yeop;Kim Jin-Mo;Kim Hyung-Soo;Lee Sang-Bek;Park Eugene;Bae Sung-Soo
    • Membrane Journal
    • /
    • v.15 no.2
    • /
    • pp.114-120
    • /
    • 2005
  • The purpose of this study is to obtain practical information about membrane coupled $ A_2O$ system for muncipal wastewater treatment. A flat-plate microfiltration (MF) module with a pore size $0.25\;{\mu}m$ was submerged into the aeration basin and treated water was filtrated through the membrane by continuous suction with low pressure. The system was operated with synthetic wastewater to find operational parameters of internal recycle ratio and maximum MLSS showing best water quality and long-term stability. The internal recycle was defined as type 1 for aerobic to anoxic tank and type 2 for anoxic to anaerobic tank, respectively When the flux was maintained at $0.015\;m^3/m^2/hr$ (15 LMH) with 2Q type 1 internal recycle ratio, the optimal operational setting were 10 internal recycle ratio for type 2 and maximum MLSS of 11,000 mg/L among tested conditions. At this condition, removal efficiencies of BOD, CODcr, T-N and T-P showed $97.3\%,\;94.2\%,\;64.0\%,\;63.0\%$, respectively.